Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Temperature dependence of the electronic structure of semiconductors and insulators

The renormalization of electronic eigenenergies due to electron-phonon coupling (temperature dependence and zero-point motion effect) is sizable in many materials with light atoms. This effect, often neglected in ab initio calculations, can be computed using the perturbation-based Allen-Heine-Cardona theory in the adiabatic or non-adiabatic harmonic approximation. After a short description of the recent progresses in this field and a brief overview of the theory, we focus on the issue of phonon wavevector sampling convergence, until now poorly understood. Indeed, the renormalization is obtained numerically through a slowly converging q-point integration. For non-zero Born effective charges, we show that a divergence appears in the electron-phonon matrix elements at q → Γ, leading to a divergence of the adiabatic renormalization at band extrema. This problem is exacerbated by the slow convergence of Born effective charges with electronic wavevector sampling, which leaves residual Born effective charges in ab initio calculations on materials that are physically devoid of such charges. Here, we propose a solution that improves this convergence. However, for materials where Born effective charges are physically non-zero, the divergence of the renormalization indicates a breakdown of the adiabatic harmonic approximation, which we assess here by switching to the non-adiabatic harmonic approximation. Also, we study the convergence behavior of the renormalization and develop reliable extrapolation schemes to obtain the converged results. Finally, the adiabatic and non-adiabatic theories, with corrections for the slow Born effective charge convergence problem (and the associated divergence) are applied to the study of five semiconductors and insulators: α-AlN, β-AlN, BN, diamond, and silicon. For these five materials, we present the zero-point renormalization, temperature dependence, phonon-induced lifetime broadening, and the renormalized electronic band structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data associated with Quaternary Research manuscript Latest Pleistocene glacial chronology and paleoclimate reconstruction for the East River watershed, Colorado, USA

The data here are associated with Quaternary Research manuscript Latest Pleistocene glacial chronology and paleoclimate reconstruction for the East River watershed, Colorado, USA and include data associated with cosmogenic exposure and depth profile dating as well as glacier-climate numerical modeling. Reconstructing Pleistocene glaciation timing and extent is vital for understanding paleoclimate. While late Pleistocene glaciation has been studied extensively in western North American mountain ranges, the glacial history of the western Elk Range in Colorado remains understudied, particularly in the East River watershed, a site of intense scientific focus. Here we use cosmogenic nuclide exposure and depth–profile dating methods to determine the timing of glaciation in the East River watershed. We use glacier modeling to reconstruct paleoglacier extents and quantify past climate conditions. Our findings indicate that the East River glacier retreated from its maximum position approximately 17–18 ka, moving to recessional positions between 13–15 ka, before experiencing more substantial retreat to high-elevation cirques around 12.9 ka. Glacier modeling suggests that the maximum ice extents at 17–18 ka could have been sustained by temperature depressions of approximately −6.5°C compared to modern conditions, assuming consistent precipitation. Additionally, the ice position at 13–15 ka could have been supported by temperature depressions of around −4.0°C. These results offer insights into the deglaciation timeline in the East River watershed and broader western Elk Range as well as paleoclimate conditions during the late Pleistocene, which may aid future research on critical zone evolution in the East River watershed.The data files include: 1. Table 1 In situ-produced 10Be sample data (.pdf, .csv, .xlsx)2. Table 2 In situ-produced 10Be exposure age results (.pdf, .csv, .xlsx)3. S1_A CRONUS calculator input assuming no erosion (.csv)4. S1_B CRONUS calculator input assuming erosion (.csv)5. S1_C CRONUS calculator results and comparison (.csv)6. S2_A In situ-produced 10Be sample data for depth profile (.csv)7. S2_B In situ-produced 10Be depth profile model input (.csv)8. S2_C In situ-produced 10Be depth profile model results (.csv)9. S3 Monthly cloudiness, rH, and windspeed data used in glacier climate model (.csv)10. S4 Glacier climate model results (.csv)

54 ENVIRONMENTAL SCIENCES↗

Inhomogeneity in electronic phase and flat band in magnetic kagome metal Co 3 Sn 2 S 2

Co 3 Sn 2 S 2 has been reported to be a Weyl semimetal with c-axis ferromagnetism below a Curie temperature of 177 K. Despite the large interest in Co 3 Sn 2 S 2 , the magnetic structure is still unclear. Recent studies have challenged the magnetic phase diagram of Co 3 Sn 2 S 2 by reporting unusual magnetic phases including the presence of exchange bias. Here we show, using X-ray Magnetic Circular Dichroism, a shift in the magnetization hysteresis loop, reminiscent of exchange bias and establish that the magnetic moment in Co arises from the spin, with negligible orbital moment. At 6 K, using spatially-resolved angle-resolved photoemission spectroscopy, we detect a butterfly-shaped electronic band structure at small regions of the sample distinct from the known ferromagnetic band structure. Our density functional theory calculations suggest that the butterfly bands correspond to an antiferromagnetic phase. Separately, we detect a sharp flat band at the Fermi level at some regions in the sample, which we attribute to a surface state. These different electronic states found in a stoichiometric intermetallic invite further efforts to explore the origin and nature of the electronic inhomogeneity associated to magnetism on the mesoscale.

Electronic properties and materials↗

Breakdown of the drift-diffusion model for transverse spin transport in a disordered Pt film

Spin-accumulation and spin-current profiles are calculated for a disordered Pt film subjected to an in-plane electric current within the nonequilibrium Green's function approach. In the bulklike region of the sample, this approach captures the intrinsic spin Hall effect found in other calculations. Near the surfaces, the results reveal qualitative differences with the results of the widely used spin-diffusion model, even when the boundary conditions are modified to try to account for them. One difference is that the effective spin-diffusion length for transverse spin transport is significantly different from its longitudinal counterpart and is instead similar to the mean-free path. Furthermore, this feature may be generic for spin currents generated via the intrinsic spin Hall mechanism because of the differences in transport mechanisms compared to longitudinal spin transport. Orbital accumulation in the Pt film is only significant in the immediate vicinity of the surfaces and has a small component penetrating into the bulk only in the presence of spin-orbit coupling, as a secondary effect induced by the spin accumulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the resonant photoemission of radiation damaged Pu

Here, the resonant photoelectron spectroscopy (ResPes) of new and aged δ-Pu(Ga) is reassessed by using the small oxygen contaminant peaks as an independent and quantitative check upon conventional cross-photon-energy normalization. Good agreement is found between the measured oxygen intensities and the atomic cross section calculations. Consistent with earlier analyses, the radiation induced damage in the aged samples is found to compress and sharpen the 5f peaks. This is associated with increased localization of the 5f bands, corresponding to the 5f density of states calculations that show a narrowing of 5f bandwidth with cluster size diminishment.

36 MATERIALS SCIENCE↗

Fabrication and processing of next-generation oxygen carrier materials for chemical looping combustion

Among numerous methods of controlling the global warming effect, Chemical Looping Combustion is known to be the most viable option currently. A key factor to a successful chemical looping process is the presence of highly effective oxygen carriers that enable fuel combustion by going through oxidation and reduction in the presence of air and fuel respectively. In this study, CaMnO 3-δ was used as the base material and doped on the A-site (Sr or La) and B-site (Fe, Ti, Zn and Al) by 10 mol % of dopants. Solid state reaction followed by mechanical extrusion (optimized paste formula) was used as the preparation method A series of novel doped perovskite-type oxygen carrier particles (Ca x La (Or Sa) 1-x Mn 1-y ByO 3-δ (B-site = Fe, Ti, Al, or Zr)) were synthesized by the proposed extrusion formula. The produced samples were characterized with XRD, SEM, BET and TGA techniques. According to the results obtained from TGA analysis, the oxygen capacity of the samples ranged between 1.2 for CLMZ and 1.75 for CSMF. Reactivity and oxygen uncoupling behaviors of the prepared samples were also evaluated using a fluidized bed chemical looping reactor using methane as the fuel at four different temperatures (800, 850, 900, 950 °C). All of the oxygen carriers showed oxygen uncoupling behavior and they were able to capture and release oxygen. Mass-based conversion of the perovskites was calculated and temperature increase proved to increase the mass-based conversion rate in all of the samples under study. Gas yield was calculated at 950 °C as well, and results showed that CLMZ, CM and CSMF showed 100% gas yields and CLMF and CSMZ showed approximately 85% yield in fluidized bed reactor, which is a high and acceptable quantity. Based on extended reactor tests the modified calcium manganese perovskite structures (CSMF) can be a good candidate for future pilot tests.

30 DIRECT ENERGY CONVERSION↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Raman thermometry: Effective temperature of the nonuniform temperature field induced by a Gaussian laser

Raman spectroscopy is a widely applied analytical technique with numerous applications that is based on inelastic scattering of monochromatic light, which is typically provided by a laser. Irradiation of a sample by a laser beam is always accompanied by an increase in the sample temperature, which may be unwanted or may be beneficial for studying temperature-related effects and determining thermal parameters. This work reports analyses of the temperature field induced by a Gaussian laser to calculate the Raman scattered intensity related to each temperature value of the nonuniform field present on the sample. The effective temperature of the probed field, calculated as an average weighted by the laser intensity, is demonstrated to be about 70% of the maximum temperature irrespective of the absorption coefficient or the laser focus. Finally, using crystalline silicon as a model material, it is shown that this effective value closely approximates the temperature value identified from the thermally related peak shift.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Historic climate, cosmogenic 10Be, denudation-rate, and geospatial datasets from the Pikes Peak region, Colorado, USA

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of elevation-dependent denudation rates on Pikes Peak in the Front Range of the Rocky Mountains, Colorado, USA. The package includes GIS layers used to produce the study-area map, including sample locations, sample watershed boundaries, the Pikes Peak batholith, Pleistocene glacier extent, weather station locations, and elevation and hillshade rasters, together with comma-separated value (CSV) tables and matching CSV data dictionaries. These mapped layers provide the geographic framework for interpreting denudation patterns across the Pikes Peak region and for relating sample locations to watershed geometry, bedrock setting, glacial history, and nearby climate stations. The first group of tables reports climate and geospatial context for the study area. These files include station-based temperature and precipitation data used to characterize elevational gradients in mean annual climate and monthly climate seasonality, sample locations, denudation-rate and topographic metrics, fixed frost-cracking model parameters, frost-cracking intensity and precipitation-frequency metrics, and stream-power inversion results. Together, these data provide the basis for evaluating how denudation varies with elevation, climate, and landscape form across sampled catchments on Pikes Peak. The second group of tables reports cosmogenic nuclide and erosion-model results used in the denudation analysis. Included files contain accelerator mass spectrometry (AMS) measurements for in situ-produced cosmogenic beryllium-10 (10Be), including sample identifiers, measured 10Be:9Be ratios, analytical uncertainties, carrier mass, quartz mass, blank corrections, blank-group statistics, and calculated 10Be concentrations and uncertainties. Additional tables summarize stream-power-law inversion results for sampled catchments, including optimized model parameters, predicted erosion rates, residual metrics, channel-pixel counts, and convergence status, as well as regression equations and summary statistics used to evaluate relationships among elevation, climate, frost cracking, precipitation forcing, and denudation rate. The package contains GIS files, comma-separated value files (.csv), Microsoft Excel files (.xlsx), CSV data dictionaries, a file-level metadata table, and a readme text file.

10Be cosmogenic nuclides↗

Implementation of structural response sensitivity calculations in a large-scale finite-element analysis system

The methodology used to implement structural sensitivity calculations into a major, general-purpose finite-element analysis system (SPAR) is described. This implementation includes a generalized method for specifying element cross-sectional dimensions as design variables that can be used in analytically calculating derivatives of output quantities from static stress, vibration, and buckling analyses for both membrane and bending elements. Limited sample results for static displacements and stresses are presented to indicate the advantages of analytically calculating response derivatives compared to finite difference methods. Continuing developments to implement these procedures into an enhanced version of SPAR are also discussed.

Giles, G. L.↗

Sample band spreading phenomena in ground and space-based electrophoretic separators

Sample stream spreading in the transverse direction (direction perpendicular to the chamber center plane) is calculated for two ground-based and one space-based continuous flow electrophoresis chambers. The magnitude of transverse sample stream spreading is shown to be a function of the difference in electrical conductivity between the sample and curtain buffer. Sample/buffer conductivity mismatch distorts the normally uniform electrical field in the vicinity of the sample to produce transverse field components which, in turn, deflect sample material toward the chamber walls. These results indicate that nongravity effects are important and must be resolved in order for space-based continuous flow electrophoresis to achieve its maximum potential.

Rhodes, Percy H.↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

French, R. A.↗

Novel Hybrid Monte Carlo/Deterministic Technique for Shutdown Dose Rate Analyses of Fusion Energy Systems

The rigorous 2-step (R2S) method uses three-dimensional Monte Carlo transport simulations to calculate the shutdown dose rate (SDDR) in fusion reactors. Accurate full-scale R2S calculations are impractical in fusion reactors because they require calculating space- and energy-dependent neutron fluxes everywhere inside the reactor. The use of global Monte Carlo variance reduction techniques was suggested for accelerating the neutron transport calculation of the R2S method. The prohibitive computational costs of these approaches, which increase with the problem size and amount of shielding materials, inhibit their use in the accurate full-scale neutronics analyses of fusion reactors. This paper describes a novel hybrid Monte Carlo/deterministic technique that uses the Consistent Adjoint Driven Importance Sampling (CADIS) methodology but focuses on multi-step shielding calculations. The Multi-Step CADIS (MS-CADIS) method speeds up the Monte Carlo neutron calculation of the R2S method using an importance function that represents the importance of the neutrons to the final SDDR. Using a simplified example, preliminarily results showed that the use of MS-CADIS enhanced the efficiency of the neutron Monte Carlo simulation of an SDDR calculation by a factor of 550 compared to standard global variance reduction techniques, and that the increase over analog Monte Carlo is higher than 10,000.

hybrid Monte Carlo/deterministic↗

The diagnostic capability of x-ray scattering parameters for the characterization of breast cancer

Purpose: The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I{sub 2}/I{sub 1}%) at 1.6 nm{sup -1} to that at 1.1 nm{sup -1} (corresponding to scattering from soft and adipose tissues, respectively). Methods: A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves. Results: At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94%[for I{sub 2}/I{sub 1}% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance. Conclusions: The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples.

60 APPLIED LIFE SCIENCES↗

KSSOLV 2.0: An efficient MATLAB toolbox for solving the Kohn-Sham equations with plane-wave basis set

KSSOLV (Kohn-Sham Solver) is a MATLAB toolbox for performing Kohn-Sham density functional theory (DFT) calculations with a plane-wave basis set. KSSOLV 2.0 preserves the design features of the original KSSOLV software to allow users and developers to easily set up a problem and perform ground-state calculations as well as to prototype and test new algorithms. Furthermore, it includes new functionalities such as new iterative diagonalization algorithms, k-point sampling for electron band structures, geometry optimization and advanced algorithms for performing DFT calculations with local, semi-local, and hybrid exchange-correlation functionals. It can be used to study the electronic structures of both molecules and solids. So, we describe these new capabilities in this work through a few use cases. We also demonstrate the numerical accuracy and computational efficiency of KSSOLV on a variety of examples.

97 MATHEMATICS AND COMPUTING↗