Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Radiative transfer with partial frequency redistribution in inhomogeneous atmospheres - Application to the Jovian aurora

A direct finite difference numerical solution for the equation of radiative transfer by the Feautrier method is developed for use in planetary atmospheres. The procedure described here uses a plane-parallel atmosphere, and can treat partial frequency redistribution, inhomogeneity, external or internal sources, and various boundary conditions. Isotropic scattering is assumed, but in the case of no frequency redistribution, Rayleigh scattering can also be handled. A program utilizing this method is tested in a variety of situations against more powerful and elaborate methods. The case of the Lyman alpha aurora on Jupiter is then considered, where the effects of partial frequency redistribution are shown to be of great importance. New results for the detailed line profiles for Lyman alpha in the Jovian aurora are presented. The method is quite versatile, and should be especially useful in studying a wide range of problems related to auroral or dayglow emissions in planetary atmospheres.

Gladstone, G. R.↗

On compactness of admissible parameter sets: Convergence and stability in inverse problems for distributed parameter systems

A series of numerical examples is reported and several algorithms compared for estimation of coefficients in differential equation models. Unconstrained, constrained and Tikhonov regularization methods are tested for their behavior with regard to both convergence (of approximation methods for the states and parameters) and stability (continuity of the estimates with respect to perturbations in the data or observed states).

Banks, H. T.↗

A Size Effect on the Fatigue Crack Growth Rate Threshold of Alloy 718

Fatigue crack growth rate (FCGR) tests were conducted on Alloy 718 in the solution annealed and aged condition at room temperature. In each test, the FCGR threshold was measured using the decreasing (Delta)K method. Initial testing was at two facilities, one of which used C(T) specimens with W = 127 mm. Previous data at the other facility had been obtained with specimens with W = 50.8 mm. A comparison of test results at R = 0.1 showed that the threshold for the 127 mm specimen was considerably higher than that of the 50.8 mm specimen. A check showed that this difference was not due to a heat-to-heat or lab-to-lab variation. Additional tests were conducted on specimens with W = 25.4 mm and at other R values. Data for the various specimens is presented along with parameters usually used to describe threshold behavior.

Garr, K. R.↗

Ribosomal RNA: a key to phylogeny

As molecular phylogeny increasingly shapes our understanding of organismal relationships, no molecule has been applied to more questions than have ribosomal RNAs. We review this role of the rRNAs and some of the insights that have been gained from them. We also offer some of the practical considerations in extracting the phylogenetic information from the sequences. Finally, we stress the importance of comparing results from multiple molecules, both as a method for testing the overall reliability of the organismal phylogeny and as a method for more broadly exploring the history of the genome.

NASA Program Exobiology↗

Multi Agent Reward Analysis for Learning in Noisy Domains

In many multi agent learning problems, it is difficult to determine, a priori, the agent reward structure that will lead to good performance. This problem is particularly pronounced in continuous, noisy domains ill-suited to simple table backup schemes commonly used in TD(lambda)/Q-learning. In this paper, we present a new reward evaluation method that allows the tradeoff between coordination among the agents and the difficulty of the learning problem each agent faces to be visualized. This method is independent of the learning algorithm and is only a function of the problem domain and the agents reward structure. We then use this reward efficiency visualization method to determine an effective reward without performing extensive simulations. We test this method in both a static and a dynamic multi-rover learning domain where the agents have continuous state spaces and where their actions are noisy (e.g., the agents movement decisions are not always carried out properly). Our results show that in the more difficult dynamic domain, the reward efficiency visualization method provides a two order of magnitude speedup in selecting a good reward. Most importantly it allows one to quickly create and verify rewards tailored to the observational limitations of the domain.

Tumer, Kagan↗

PIV Measurements of a Low-noise Top-mounted Propulsion Installation for a Supersonic Airliner

A model-scale exhaust system was tested to validate low-noise propulsion concepts and noise prediction methods. The tests involved far-field acoustics, phased array, and particle image velocimetry (PIV). This paper covers the particle image velocimetry portion. Data was acquired at NASA Glenn's Aero-Acoustic Propulsion Lab for a series of nozzles with different chevron designs, both uninstalled and installed on a representative aircraft planform. The impact of the various chevron treatments on the turbulent velocity field was documented, along with the impact of the pylon and planform. When correlated with far-field acoustic measurements and phased array measurements, reported in companion papers, the explanation of acoustic benefits from top-mounted propulsion is clear as is the path toward optimization of the concept.

Propulsion Airframe Integration↗

CPAS Airdrop Test Joint Recertification by Analysis

Airdrop testing of parachutes is a complicated endeavor that requires the custom design and certification of many critical components. The most direct path to certifying a component is to perform full scale testing with margin over the maximum loads expected to be seen in operation. However, other constraints often preclude the opportunity to perform full scale testing. In this paper, we present a case study where a problem arises in a joint that had been certified with a full scale test. There was no time or budget available to repeat the full scale testing after a redesign of the joint. Instead, we present a method of testing each failure mode at the component level to support a certification by analysis approach. The analysis itself was not complicated, but tradeoffs had to be made between different failure modes to arrive at the optimal design. The same approach was also applied back to the original joint to confirm that the failure mode that was not seen in full scale testing would have been caught by the proposed analysis. In the end, the new design was certified by analysis and worked without issue for the final six airdrop tests that used this joint.

McCann, Charles J.↗

Fuel Burn Estimation Using Real Track Data

A procedure for estimating fuel burned based on actual flight track data, and drag and fuel-flow models is described. The procedure consists of estimating aircraft and wind states, lift, drag and thrust. Fuel-flow for jet aircraft is determined in terms of thrust, true airspeed and altitude as prescribed by the Base of Aircraft Data fuel-flow model. This paper provides a theoretical foundation for computing fuel-flow with most of the information derived from actual flight data. The procedure does not require an explicit model of thrust and calibrated airspeed/Mach profile which are typically needed for trajectory synthesis. To validate the fuel computation method, flight test data provided by the Federal Aviation Administration were processed. Results from this method show that fuel consumed can be estimated within 1% of the actual fuel consumed in the flight test. Next, fuel consumption was estimated with simplified lift and thrust models. Results show negligible difference with respect to the full model without simplifications. An iterative takeoff weight estimation procedure is described for estimating fuel consumption, when takeoff weight is unavailable, and for establishing fuel consumption uncertainty bounds. Finally, the suitability of using radar-based position information for fuel estimation is examined. It is shown that fuel usage could be estimated within 5.4% of the actual value using positions reported in the Airline Situation Display to Industry data with simplified models and iterative takeoff weight computation.

Chatterji, Gano B.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Wind tunnel wall interference in closed, ventilated and adaptive test sections

A wall interference correction method for closed rectangular test sections was developed which uses measured wall pressures. Measurements with circular discs for blockage and a rectangular wing as a lift generator in a square closed test section validate this method. These measurements are intended to be a basis of comparison for measurements in the same tunnel using ventilated (in these case, slotted) walls. Using the vortex lattice method and homogeneous boundary conditions, calculations were performed which show sufficiently high pressure levels at the walls for correction purposes in test sections with porous walls. In Gottingen, an adaptive test section (which is a deformable rubber tube of 800 mm diameter) was built and a computer program was developed which is able to find the necessary wall adaptation for interference-free measurements in a single step. To check the program prior to the first run, the vortex lattice method was used to calculate wall pressure distributions in the nonadapted test section as input data for the one-step method. Comparison of the pressure distribution in the adapted test section with free-flight data shows nearly perfect agreement. An extension of the computer program can be made to evaluate the remaining interference corrections.

Holst, H.↗

Solder Joint Health Monitoring Testbed System

The density and pin count for Field Programmable Gate Arrays (FPGAs) has been increasing, and has exceeded current methods of solder joint inspection, making early detection of failures more problematic. These failures are a concern for both flight safety and maintenance in commercial aviation. Ridgetop Group, Inc. has developed a method for detecting solder joint failures in real time. The NASA Dryden Flight Research Center is developing a set of boards to test this method in ground environmental and accelerated testing as well as flight test on a Dryden F-15 or F-18 research aircraft. In addition to detecting intermittent and total solder joint failures, environmental data on the boards, such as temperature and vibration, will be collected and time-correlated to aircraft state data. This paper details the technical approach involved in the detection process, and describes the design process and products to date for Dryden s FPGA failure detection boards.

Delaney, Michael M.↗

Examination of a Rotorcraft Noise Prediction Method and Comparison to Flight Test Data

With a view that rotorcraft noise should be included in the preliminary design process, a relatively fast noise prediction method is examined in this paper. A comprehensive rotorcraft analysis is combined with a noise prediction method to compute several noise metrics of interest. These predictions are compared to flight test data. Results show that inclusion of only the main rotor noise will produce results that severely underpredict integrated metrics of interest. Inclusion of the tail rotor frequency content is essential for accurately predicting these integrated noise metrics.

Boyd, D. Douglas, Jr.↗

Aeroheating model advancements featuring electroless metallic plating

Discussed are advancements in wind tunnel model construction methods and hypersonic test data demonstrating the methods. The general objective was to develop model fabrication methods for improved heat transfer measuring capability at less model cost. A plated slab model approach was evaluated with cast models containing constantan wires that formed single-wire-to-plate surface thermocouple junctions with a seamless skin of electroless nickel alloy. The surface of a space shuttle orbiter model was selectively plated with scaled tiles to simulate, with high fidelity, the probable misalignments of the heatshield tiles on a flight vehicle. Initial, Mach 8 heating results indicated a minor effect of tile misalignment roughness on boundary layer transition, implying a possible relaxation of heatshield manufacturing tolerances. Some loss of the plated tiles was experienced when the model was tested at high heating rates.

Stalmach, C. J., Jr.↗

Fire containment tests of aircraft interior panels

The paper describes an experimental program carried out to evaluate a possible method for testing the fire-containment qualities of aircraft interior panels. The experimental apparatus consisted of a burner that simulates various fire loads under different ventilation conditions in an enclosure of approximately the same size as an aircraft lavatory module. Two fire-containment tests are discussed in which two adjoining walls of the enclosure were made from state-of-the-art composite panels; rats were exposed to the combustion products in order to evaluate the toxic threat posed by those products. The results show that the burner can be employed to represent various fire-load conditions and that the methodology developed for fire containment can be useful in evaluating the fire resistance of composite panels before conducting large-scale tests. It is concluded that elements of the fire-containment criteria include the temperature rise on the backface of the panels as a function of time, the flame burn-through by either decomposition or severe distortion of the material, and the toxicity of the combustion gases evolved.

Kourtides, D. A.↗

Ultrasonics. Volume 3 - Applications

Selection of test equipment, techniques, and methods for ultrasonic testing - programmed instruction textbook on nondestructive testing

Source record↗

An Experimental Evaluation of Advanced Rotorcraft Airfoils in the NASA Ames Eleven-foot Transonic Wind Tunnel

Five full scale rotorcraft airfoils were tested in the NASA Ames Eleven-Foot Transonic Wind Tunnel for full scale Reynolds numbers at Mach numbers from 0.3 to 1.07. The models, which spanned the tunnel from floor to ceiling, included two modern baseline airfoils, the SC1095 and SC1094 R8, which have been previously tested in other facilities. Three advanced transonic airfoils, designated the SSC-A09, SSC-A07, and SSC-B08, were tested to confirm predicted performance and provide confirmation of advanced airfoil design methods. The test showed that the eleven-foot tunnel is suited to two-dimensional airfoil testing. Maximum lift coefficients, drag coefficients, pitching moments, and pressure coefficient distributions are presented. The airfoil analysis codes agreed well with the data, with the Grumman GRUMFOIL code giving the best overall performance correlation.

Flemming, Robert J.↗

Analysis of large system black box verification test data

Issues regarding black box, large systems verification are explored. It begins by collecting data from several testing teams. An integrated database containing test, fault, repair, and source file information is generated. Intuitive effectiveness measures are generated using conventional black box testing results analysis methods. Conventional analysts methods indicate that the testing was effective in the sense that as more tests were run, more faults were found. Average behavior and individual data points are analyzed. The data is categorized and average behavior shows a very wide variation in number of tests run and in pass rates (pass rates ranged from 71 percent to 98 percent). The 'white box' data contained in the integrated database is studied in detail. Conservative measures of effectiveness are discussed. Testing efficiency (ratio of repairs to number of tests) is measured at 3 percent, fault record effectiveness (ratio of repairs to fault records) is measured at 55 percent, and test script redundancy (ratio of number of failed tests to minimum number of tests needed to find the faults) ranges from 4.2 to 15.8. Error prone source files and subsystems are identified. A correlational mapping of test functional area to product subsystem is completed. A new adaptive testing process based on real-time generation of the integrated database is proposed.

Clapp, Kenneth C.↗