Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

AMIE Delivers Innovation

ORNL and many industry partners developed the Additive Manufacturing Integrated Energy (AMIE) demonstration to address electricity supply and reliability challenges via an integrated approach to power generation, storage, and use. AMIE demonstrates rapid innovation through additive manufacturing (3D printing) to connect a natural gas-powered hybrid electric vehicle to a high-performance building that produces, consumes, and stores renewable energy. To offset power supply disruptions, the vehicle’s engine can provide complementary power to the building. Fitted with an advanced power control system and then scaled up, this concept can support electricity needs worldwide.

25 ENERGY STORAGE↗

Hybrid Solar GHP Simulator

This project provides an easy-to-use, menu-driven, software tool for designing hybrid solar-geothermal heat pump systems (GHP) for both heating- and cooling-dominated buildings. No such design tool currently exists. In heating-dominated buildings, the design approach takes advantage of glazed solar collectors to effectively balance the annual thermal loads on the ground with renewable solar energy. In cooling-dominated climates, the design approach takes advantage of relatively low-cost, unglazed solar collectors as the heat rejecting component. The primary benefit of hybrid GHPs is the reduced initial cost of the ground heat exchanger (GHX). Furthermore, solar thermal collectors can be used to balance the ground loads over the annual cycle, thus making the GHX fully sustainable; in heating-dominated buildings, the hybrid energy source (i.e., solar) is renewable, in contrast to a typical fossil fuel boiler or electric resistance as the hybrid component; in cooling-dominated buildings, use of unglazed solar collectors as a heat rejecter allows for passive heat rejection, in contrast to a cooling tower that consumes a significant amount of energy to operate, and hybrid GHPs can expand the market by allowing reduced GHX footprint in both heating- and cooling-dominated climates. The design tool allows for the straight-forward design of innovative GHP systems that currently pose a significant design challenge. The project lays the foundations for proper and reliable design of hybrid GHP systems, overcoming a series of difficult and cumbersome steps without the use of a system simulation approach, and without an automated optimization scheme. As new technologies and design concepts emerge, sophisticated design tools and methodologies must accompany them and be made usable for practitioners. Lack of reliable design tools results in reluctance of practitioners to implement more complex systems. A menu-driven software tool for the design of hybrid solar GHP systems is provided that is based on mathematically robust, validated models. An automated optimization tool is used to balance ground loads and incorporated into the simulation engine. With knowledge of the building loads, thermal properties of the ground, the borehole heat exchanger configuration, the heat pump peak hourly and seasonal COP for heating and cooling, the critical heat pump design entering fluid temperature, and the thermal performance of a solar collector, the total GHX length can be calculated along with the area of a supplemental solar collector array and the corresponding reduced GHX length. An economic analysis module allows for the calculation of the lowest capital cost combination of solar collector area and GHX length.

Yavuzturk, Cy↗

Numerical Study and Validation of Melting and Solidification in PCM Embedded Heat Exchangers with Straight Tube

Latent heat thermal energy storage (LHTES) systems have shown great potential to enable reliable use of renewable energy and load shifting. LHTES offer high storage density and release energy at near constant temperature because of its use of phase change materials (PCMs). The cylindrical PCM heat exchangers (PCMHX) are one of the most used technologies due to their simplicity. Numerical models for such PCMHX enable engineers to estimate their performance for different design parameters and operating conditions without having to test them all. However, modeling the phase change phenomena can be challenging. To better understand the difficulties involving accurate modeling of PCMHX, a cylindrical latent storage unit filled with PCM and water as in-tube heat transfer fluid (HTF) is numerically investigated. This paper presents a study based on a 2D-axisymmetric model of a straight tube embedded in PCM in a cylindrical container. CFD is used to study the charging (melting) and discharging (solidification) phenomena. The models are validated against experimental and numerical data from the literature. The predicted local PCM temperature profile over time agrees within 2K compared to the experimental values. The paper also presents a simple method to estimate the melting and solidification phase change temperature range from limited data provided by PCM manufacturers.

PCM, melting, solidification, CFD, heat exchanger↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting hidden transient events in noisy nonlinear time-series

The information impulse function (IIF), running Variance, and local Hölder Exponent are three conceptually different time-series evaluation techniques. These techniques examine time-series for local changes in information content, statistical variation, and point-wise smoothness, respectively. Using simulated data emulating a randomly excited nonlinear dynamical system, this study interrogates the utility of each method to correctly differentiate a transient event from the background while simultaneously locating it in time. Computational experiments are designed and conducted to evaluate the efficacy of each technique by varying pulse size, time location, and noise level in time-series. Our findings reveal that, in most cases, the first instance of a transient event is more easily observed with the information-based approach of IIF than with the Variance and local Hölder Exponent methods. While our study highlights the unique strengths of each technique, the results suggest that very robust and reliable event detection for nonlinear systems producing noisy time-series data can be obtained by incorporating the IIF into the analysis.

42 ENGINEERING↗

Hydrogen Education for a Decarbonized Global Economy (H 2 EDGE) (Final Technical Report)

The energy sector is undergoing rapid growth and transformation, creating urgent demand for a skilled workforce to support emerging technologies and resilient systems. Hydrogen is an emerging solution for “hard to abate” sectors, including heavy industry and transportation that also provides optionality for the electric system and enables long‑duration energy storage. As hydrogen scales from traditional industrial uses to new applications, success depends on knowledgeable engineers, technicians, planners, and operators safely deploying hydrogen technologies across the full value chain: production, delivery, storage, and end use. The H 2 EDGE initiative, funded by the U.S. Department of Energy’s Hydrogen and Fuel Cell Technologies Office from 2020 to 2025, was launched to prepare people for careers hydrogen and related technologies. Through its interactive approach, H 2 EDGE equipped stakeholders with knowledge and tools to build a reliable and sustainable energy future together. H 2 EDGE built a national network of academic and industry partners to deliver modular training, share open-access curricula, and engage diverse talent pipelines. The program leveraged EPRI’s extensive industry membership and expanded on the train-the-trainer model of the GridEd program to connect educators, employers, and community organizations across all regions of the U.S. New methods were introduced to more systematically map hydrogen competencies and assess curricula using traditional and AI-assisted approaches. Outcomes included delivery of professional short courses, developing university curriculum, sponsoring faculty and student projects, and engaging stakeholders through workshops, site tours, and webinars.

08 HYDROGEN↗

Bayesian analysis for estimating statistical parameter distributions of elasto-viscoplastic material models

High temperature design methods rely on constitutive models for inelastic deformation and failure typically calibrated against the mean of experimental data without considering the associated scatter. Variability may arise from the experimental data acquisition process, from heat-to-heat material property variations, or both and need to be accurately captured to predict parameter bounds leading to efficient component design. Applying the Bayesian Markov Chain Monte Carlo (MCMC) method to produce statistical models capturing the underlying uncertainty in the experimental data is an area of ongoing research interest. This work varies aspects of the Bayesian MCMC method and explores their effect on the posterior parameter distributions for a uniaxial elasto-viscoplastic damage model using synthetically generated reference data. From our analysis with the uniaxial inelastic model we determine that an informed prior distribution including different types of test conditions results in more accurate posterior parameter distributions. The parameter posterior distributions, however, do not improve when increasing the number of similar experimental data. Additionally, changing the amount of scatter in the data affects the quality of the posterior distributions, especially for the less sensitive model parameters. Moreover, we perform a sensitivity study of the model parameters against the likelihood function prior to the Bayesian analysis. The results of the sensitivity analysis help to determine the reliability of the posterior distributions and reduce the dimensionality of the problem by fixing the insensitive parameters. The comprehensive study described in this work demonstrates how to efficiently apply the Bayesian MCMC methodology to capture parameter uncertainties in high temperature inelastic material models. Quantifying these uncertainties in inelastic models will improve high temperature engineering design practices and lead to safer, more effective component designs.

42 ENGINEERING↗

Using simulators to assess knowledge and behavior of “novice” operators of critical infrastructure under cyberattack events

—The transition from the traditional power grid to the smart grid improves reliability, performance, and management, while simultaneously increasing its susceptibility to cyberattacks. One of the biggest weaknesses in grid security is the human agent responsible for its maintenance and operations. As such, it is crucial to embed hands-on understanding of grid operations and security, especially for students in the Electrical and Computer Engineering (ECE) fields. This paper presents a case study where ECE students from Temple University used an interactive microgrid simulator, "Grid Game", a program developed by Idaho National Laboratory. This case study offers insights into the ECE students’ understanding of key engineering principles (microgrid stability, generation control system, generator inertia, energy storage, and grid security) gained by using the simulator program. Furthermore, the human behavior (strategies to prepare for and respond to cyberattacks, and cooperation and conflict in decision-making) of defenders/ECE students as they experience cyberattacks are also discussed. The paper then offers some limitations and possible suggestions for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a reduced tri-propylene glycol monomethyl ether– n -hexadecane–poly-aromatic hydrocarbon mechanism and its application for soot prediction

A reduced chemical kinetic mechanism for Tri-Propylene Glycol Monomethyl Ether (TPGME) has been developed and applied to computational fluid dynamics (CFD) calculations for predicting combustion and soot formation processes. The reduced TPGME mechanism was combined with a reduced n-hexadecane mechanism and a Poly-Aromatic Hydrocarbon (PAH) mechanism to investigate the effect of fuel oxygenation on combustion and soot emissions. The final version of the TPGME-n-hexadecane-PAH mechanism consists of 144 species and 730 reactions and was validated with experiments in shock tubes as well as in a constant volume spray combustion vessel (CVCV) from the Engine Combustion Network (ECN). The effects of ambient temperature, varying oxygen content in the tested fuels on ignition delay, spray liftoff length and soot formation under diesel-like conditions were analyzed and addressed using multidimensional reacting flow simulations and the reduced mechanism. Here, the results show that the present reduced mechanism gives reliable predictions of the combustion characteristics and soot formation processes. In the CVCV simulations, two important trends were identified. First, increasing the initial temperature in the CVCV shortens the ignition delay and lift-off length, reduces the fuel-air mixing, thereby increasing the soot levels. Secondly, fuel oxygenation introduces more oxygen into the central region of a fuel jet and reduces residence times of fuel rich area in active soot forming regions, thereby reducing soot levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TECHNOLOGY EVALUATION FOR WATERBORNE MERCURY REMOVAL AT THE Y12 NATIONAL SECURITY COMPLEX

The Hg-contaminated processing water produced at Y-12 facility is discharged through the storm drain system, merged at Outfall 200, and then discharged to EFPC. Most of the baseflow mercury at Outfall 200 arises from a small number of short sections of storm drain. This report discusses the waterborne mercury treatment technologies to decrease mercury loading to the surface water of EFPC at Y-12 NSC. We reviewed current available waterborne Hg treatment technologies based on the specific conditions of Y-12 and identified two possible options: SnCl2 reduction coupled with air stripping (SnCl2/air stripping) and sorption. The ORNL 2008 and 2009 field studies suggested that SnCl2/air stripping has the capability to remove waterborne mercury with efficiency higher than 90% at Outfall 200. To achieve this goal, dechlorination (i.e., removing residual chlorine from water) using dechlorinating agents such as thiosulfate has to be performed before the reduction. It is unclear whether or not SnCl2/air stripping can reduce the mercury concentration from ~1000 ng/L to 51 ng/L at a full-scale operation. Therefore, a pilot test is a logical step before a full-scale design to answer questions such as Hg removal efficiency, selection of dechlorinating agents, and so on. The major advantages of the SnCl2/air stripping system are: (1) expected low cost at high flow (e.g., the flow at Outfall 200); and (2) production of minimum secondary waste. However, there are many environmental uncertainties associated with this technology by introducing tin to EFPC ecosystem, for example tin methylation causing abiotic Hg methylation, which should be addressed before a full-scale implementation. Mercury adsorption by granular activated carbon (GAC) is a proven technology for treating Hg at Y-12. The ONRL 2010 lab sorption studies suggest that thiol-based resins hold the promise to combine with GAC to form a more cost-effective treatment system. To achieve a treatment goal of 51 ng/L at Outfall 200 (flow rate: 1300 gpm), using a single GAC system will request very large reaction vessels and cost much more than a SnCl2/air stripping system (assuming it can achieve the 51 ng/L goal). However, the treatment cost depends on the treatment goal. If the treatment goal is 200 ng/L, the cost of GAC system will be significantly reduced while the cost of SnCl2/air stripping will remain the same. In addition, a GAC coupled with thiol-based resin system may further reduce the cost. Treating the Hg-contaminated water at source area with low flow rate (e.g., 40 gpm) may be another option to reduce the treatment cost. The advantages of the sorption technology are that it has proven treatment efficiency, reliability, and no environmental uncertainties. The disadvantages include that it produces large amount of secondary wastes. Based on the information evaluated in this report, we recommend that a pilot-scale test for SnCl2/air stripping process at Outfall 200 should be carried out before a full-scale implementation to address all the engineering and environmental risk questions. We also recommend continuing the sorbent lab studies at ORNL to optimize a sorption system that may be efficient and cost-effective enough for a full-scale implementation.

He, Feng↗

Achieving Unprecedented CO 2 Utilization InCO 2 Concrete™: System Design, Product Development and Process Demonstration

Anthropogenic sources of carbon dioxide are generated from a number of sources, but the key among these are ordinary Portland cement (OPC) production and combustion of fossil fuels. Cement production is the largest global CO 2 source from the mineral decomposition of carbonates. This is due to the clinkering process whereby limestone (mainly consisting of CaCO 3 ) is decomposed into CaO and CO 2 , and combined with silica rich clays at high temperatures to form clinkers (i.e. the four key minerals that comprise cement). The high temperature range of 1400 – 1550°C required for this process accounts for up to 60% of the generated CO 2 from cement production. Combination of the limestone decomposition and thermal requirements of the clinkering process causes cement production to contribute 8-9% of annual global CO 2 emissions. Combustion of fossil fuels (coal, oil and gas) was shown to contribute a much larger portion of global CO 2 emissions. As of 2018, combustion of fossil fuels accounted for 65% of global CO 2 , where 41% was derived from stationary sources for electricity and heat generation and the other 24% was related to transport. To reduce these contributions, key steps forward in CO 2 utilization technologies are required. Therefore, a CO 2 mineralization technology (CO 2 mineralization concrete) to reduce the OPC content in concrete, while utilizing flue gas emissions from fossil fuel combustion has been developed to address both areas simultaneously. This Reversa™ technology utilizes low-carbon cementation agents produced by in situ CO 2 mineralization (“mineral carbonation reactions”) to offer a promising alternative to OPC. CO 2 mineralization relies upon the reaction of dissolved CO 2 with inorganic alkaline reactants to precipitate mineral carbonates (e.g., CaCO 3 ), which bind proximate particles and achieve cementation. Herein, a concrete green body, which is composed of a mixture of binder, water, and mineral aggregates, is exposed to CO 2 borne in industrial flue gas streams. This manner of CO 2 mineralization allows the production of construction components that feature equivalent engineering attributes as their OPC-based counterparts while featuring a much smaller embodied carbon intensity (eCI). The purpose of this project is to demonstrate the feasibility of the Reversa process evolving from a TRL-3 technology at the bench-scale up to TRL-6 technology at the pilot-scale. The reliability of the Reversa technology was tested to prove the effective production of three standard industrial concrete products selected during the course of the project. The results detailed herein will demonstrate the evolution of this technology to the industrial scale. The culmination of this work resulted in 9 production runs completed at the National Carbon Capture Center (NCCC), Wilsonville, AL, using natural gas (NG) flue gas as the CO 2 source. Over the course of the production runs at NCCC, the CO 2 utilization as a function of time, 24-h CO 2 uptake, electricity usage, and 28-d net area compressive strength recorded for each run. Collection of this data will be used to determine the success of the demonstration goals: (1) achieving in excess of 0.2gCO 2 /g reactant , (2) achieving greater than 50% reduction in global warming potential compared to standard produced units, and (3) ensuring compliance of carbonated concrete with industry standard specifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Triton SODAR Data to Meteorological Tower Wind Measurement Data in Hebei Province, China

With the increased interest in remote sensing of wind information in recent years, it is important to determine the reliability and accuracy of new wind measurement technologies if they are to replace or supplement conventional tower-based measurements. In view of this, HydroChina Corporation and the United States National Renewable Energy Laboratory (NREL) conducted a comparative test near awind farm in Hebei Province, China. We present the results of an analysis characterizing the measurement performance of a state-of-the-art Sound Detection and Ranging (sodar) device when compared to a traditional tower measurement program. NREL performed the initial analysis of a three-month period and sent the results to HydroChina. When another month of data became available, HydroChina andtheir consultant Beijing Millenium Engineering Software (MLN) repeated NREL's analysis on the complete data set, also adding sensitivity analysis for temperature, humidity, and wind speed (Section 6). This report presents the results of HydroChina's final analysis of the four-month period.

17 WIND ENERGY↗

A regenerative concept for thermoelectric power generation

Here this paper presents a regenerative concept for thermoelectric (TE) based waste heat recovery systems called thermoelectric generators (TEGs). TEG is usually a modified heat exchanger with the addition of thermoelectric modules (TEMs) to recover waste heat for power generation. To utilize heat from high temperature heat sources, current researches have largely been focused on the development of high temperature TE materials. In this study, we describe a regeneration concept in which a precooler is used to lower the temperature of the hot gas and at the same time regenerate hot air from the cold air supply for Bi 2 Te 3 -based TEGs, avoiding the use of high-temperature thermoelectric materials. It is found that the regenerative TEGs can achieve a similar power output compared with TEGs using high temperature TE materials such as filled-skutterudites (combined filled skutterudites and Bi 2 Te 3 TE materials) through obtaining a higher heat scavenging rate. Thus, the regenerative TEGs also have a similar absolute efficiency, defined according to the total available enthalpy from the hot gas. This could represent a paradigm shift in the TEG research and development, that much lower-cost, reliable, and readily available TE materials and modules can be used for high temperature applications, and will ultimately enable wide spread deployment of TEGs for real world waste heat recovery applications.

42 ENGINEERING↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Safety-Related Instrumentation and Control Pilot Upgrade (Initial Scoping Phase Implementation Report)

This research report (1) describes the process followed and products developed during the SR I&C Pilot Project Initial Scoping Phase, and (2) captures lessons learned. Exelon Generation and LWRS collaborated to develop a Digital Transformation Strategy as part of a larger Advanced Concept of Operations. The proposed SR I&C Pilot Upgrade provides a foundation stone for this Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant Total Cost of Ownership (TCO). Initial Scoping Phase activities for this Pilot Project have been performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process (SDP), NISP-EN-04, Standard Digital Engineering Process (SDEP), and Electric Power Research Institute (EPRI) Report 3002011816, Digital Engineering Guide (DEG). Completing Initial Scoping Phase Engineering and Operations, Licensing, and Project Management Activities was necessary to sufficiently bound the scope, schedule, and estimated cost of the Project to enable utility management to authorize moving into the Conceptual Design Phase. A significant finding of the Business Case Analysis (BCA) methodology developed and applied as part of this effort was that the growth rate of material costs for sustaining the operation of obsolete SR I&C equipment is accelerating. This directly contributed to the Project Economic Analysis created to justify continuing the Project. Project Initial Scoping Phase lessons learned have also been captured to assist the larger industry in understanding the Digital Transformation Strategy and SR I&C Pilot Project Initial Scoping Phase efforts. This is in keeping with the public/private partnership that has been established between the Department of Energy (DOE) and Exelon for this effort with engagement from the NRC. By addressing first-of-a-kind (FOAK) risks and capturing lessons learned, the SR I&C Pilot Upgrade Project addresses technical, regulatory, and business risks to enable subsequent implementers of similar upgrade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Challenges, Industry Practice, and Research Opportunities for Protection of IBR-Rich Systems

The objective of this technical report is to outline the challenges of protection design for power systems rich in inverter-based resources (IBRs), synthesize current industrial practices, review new approaches from recent literature, and explore future opportunities in protection. IBRs are experiencing widespread adoption across both transmission and distribution systems. When present in significant quantities, IBRs challenge the performance of many traditional protection functions. To address these issues, the industry has developed sophisticated protection schemes that involve advanced relaying techniques in highly engineered pilot projects. However, these schemes are expensive and time-consuming to develop, build, and test. Researchers have proposed a number of new approaches for protection in IBR-rich distribution systems. Despite their potential, these new approaches do not address some major shortcomings of industry approaches stemming from complexity, practical requirements, and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗