Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Characterization of geometrical factors for quantitative angle-resolved photoelectron spectroscopy

For conventional angle-resolved x-ray photoelectron spectroscopy (ARXPS), the area under the core-level peaks depends mainly on the in-depth distribution of chemical species at the top surface of a specimen. But the x-ray photoelectron spectroscopy (XPS) intensity is also affected by tool-related geometrical factors such as the shape of the x-ray beam, the spectrometer analysis volume, and the manipulator rotation axis. Data analysis is therefore typically based on normalization with respect to the signal from the substrate. Here, we present an original method to perform quantitative ARXPS without normalization, involving evaluation of these geometrical factors. The method is illustrated for a multiprobe XPS system using a methodology based on a specific software (XPSGeometry{sup Registered-Sign }), but is a general process that can be adapted to all types of XPS equipment, even those not specifically designed for ARXPS. In that case, this method enables bringing the sample as close as possible to the manipulator axis of rotation in order to perform automatic acquisitions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak

A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of a multilevel THz Fresnel lens by femtosecond laser ablation

The possibility of fabricating a silicon diffractive fourlevel THz Fresnel lens by laser ablation is studied. For a microrelief to be formed on the sample surface, use is made of a femtosecond Yb : YAG laser with a high pulse repetition rate (f = 200 kHz). Characteristics of the diffractive optical element are investigated in the beam of a 141-mm free-electron laser. The measured diffraction efficiency of the lens is in good agreement with the theoretical estimate. (laser technologies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Removal of Fat Components in High TDS Leather Wastewater by Saline-Tolerant Lipase-Assisted Nanoporous-Activated Carbon

The present investigation was carried out for the degradation of fatty components in high TDS containing wastewater (soak liquor) discharged from leather industry, and the degradation was achieved by saline-tolerant lipase-immobilized functionalized nanoporous-activated carbon (STLNPAC). The lipase was extracted from the halophilic organism, Bacillus cereus. The optimum conditions for lipase production such as time, 60 h; temperature, 50 °C; pH, 10; and substrate concentration, 2.5% (w/v) were determined through response surface methodology (RSM). The functionalization of NPAC was done by ethylenediamine/glutaraldehyde covalent interaction technique followed by the immobilization of saline-tolerant lipase onto FNPAC. The functional properties of STLNPAC were analyzed through instrumentation techniques such as TGA-DSC, FT-IR, XRD, and SEM images. The lipid content of soak liquor was removed by > 99% at HRT of 60 min using STLNPAC-packed bed reactor. The efficiency was evaluated by using UV-visible and FT-IR spectroscopic analyses. The degradation of lipids was best obeyed by pseudo first-order rate kinetics, and the rate constant was found to be 1.6 × 10{sup −3} min{sup −1}. The biodegradability index of soak liquor was increased from 0.322 to 0.426, highly favorable for the complete removal of organic components in subsequent operations.

60 APPLIED LIFE SCIENCES↗

Temperature Dependence of Ar{sub n}{sup +} Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature

In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the intensity variations of the backscattered Ar{sub n}{sup +} clusters as a function of temperature for several amorphous polymer surfaces (polyolefins, polystyrene, and polymethyl methacrylate). For all these investigated polymers, our results show a transition of the ratio Ar{sub 2}{sup +}/(Ar{sub 2}{sup +} + Ar{sub 3}{sup +}) when the temperature is scanned from –120 °C to +125 °C (the exact limits depend on the studied polymer). This transition generally spans over a few tens of degrees and the temperature of the inflection point of each curve is always lower than the bulk glass transition temperature (T{sub g}) reported for the considered polymer. Due to the surface sensitivity of the cluster backscattering process (several nanometers), the presented analysis could provide a new method to specifically evaluate a surface transition temperature of polymers, with the same lateral resolution as the gas cluster beam. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar irradiance computations compared with observations at the Baseline Surface Radiation Network Payerne site

Radiative transfer model calculations of solar fluxes during cloud free periods often show considerable discrepancies with surface radiation observations. Many efforts have been undertaken to explain the differences between modeled and observed shortwave downward radiation (SDR). In this study, MODTRAN4v3r1TM (designed later simply as MODTRANTM) was used for model simulations and compared with high quality radiation observations of the Baseline Surface Radiation Network (BSRN) site at Payerne, Switzerland. Results are presented for cloud free shortwave downward radiation calculations. The median differences of modeled minus observed global SDR are small (< 1%) and within the instrumental error. The differences of modeled and observed direct and diffuse SDR show larger discrepancies of -1.8% and 5.2% respectively. The diffuse SDR is generally overestimated by the model and more important, the model to observation linear regression slope and zero-intercept differs significantly from their ideal values of 1 and 0. Possible reasons for the discrepancies are presented and discussed and some modifications are investigated for decreasing such differences between modeled and observed diffuse SDR. However, we could not resolve all the discrepancies. The best agreement is obtained when comparing model simulations whose 550nm aerosol optical depth input is inferred from observations using nine spectral channels, and using BSRN observations performed with a new and more precise shading disk and sun tracker system. In this case, the median bias between model simulations and observed diffuse SDR is -0.4 Wm-2 (< 1%).

54 ENVIRONMENTAL SCIENCES↗

Axial Plane Optical Microscopy

We present axial plane optical microscopy (APOM) that can, in contrast to conventional microscopy, directly image a sample’s cross-section parallel to the optical axis of an objective lens without scanning. APOM combined with conventional microscopy simultaneously provides two orthogonal images of a 3D sample. More importantly, APOM uses only a single lens near the sample to achieve selective-plane illumination microscopy, as we demonstrated by three-dimensional (3D) imaging of fluorescent pollens and brain slices. This technique allows fast, high-contrast, and convenient 3D imaging of structures that are hundreds of microns beneath the surfaces of large biological tissues.

47 OTHER INSTRUMENTATION↗

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Role of secondary emission on discharge dynamics in an atmospheric pressure dielectric barrier discharge

The discharge dynamics in an atmospheric pressure dielectric barrier discharge (DBD) is studied in a DBD reactor consisting of a pair of stainless steel parallel plate electrodes. The DBD discharge has been generated by a 50 Hz ac high voltage power source. The high-speed intensified charge coupled device camera is used to capture the images of filaments occurring in the discharge gap. It is observed that frequent synchronous breakdown of micro discharges occurs across the discharge gap in the case of negative current pulse. The experimental results reveal that secondary emissions from the dielectric surface play a key role in the synchronous breakdown of plasma filaments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IX. LiCoO 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiCoO 2 powder obtained from BTR New Energy Materials, Inc. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Co 2p, O 1s, C 1s, Co 3s, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor tin contamination. Making use of the O 1s, Co 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiCo 0.9 O 1.7 .

25 ENERGY STORAGE↗

Optical modeling of random anti-reflective meta-surfaces for laser systems applications

In this work, optical performance of anti-reflective random meta-surfaces are studied numerically for coherent beam propagation systems, such as lasers. A methodology for the modeling of such optics performance is developed and applied to study the reflectivity and laser beam quality degradation. These quantitative metrics and design considerations highlight that reducing the size of the meta-surface period much below the light wavelength is not necessarily required.

47 OTHER INSTRUMENTATION↗

Polarization Imaging for International Safeguards (FY2019)

A polarization imaging camera, Salsa (Bossa Nova Technologies) was evaluated for use in nuclear safeguards inspection with a focus on swipe sampling. The camera and supporting electronics and software determine the full Stokes parameters for the entire image field. The camera can be used for real-time video or still images. Stokes parameters S0, S1, S2, and S3 can be recorded for each pixel and exported for post processing. This study compared color photography to polarization imaging for powders on many surfaces under ambient lighting. False color images can be created from the Stokes parameters directly from the vendor software to highlight the various polarization states. In most cases, linear polarization showed the greatest effects. The polarization images are easy to collect and very sensitive to surfaces and textures. Fine powders are highlighted in the images, and particle size and refractive index effects were noticed. The images are not affected by ambient lighting (angle, or intensity). Lens choice is key and may require expert knowledge. Very small deposits of 1 µm particles were difficult to image using the standard video lens. General dirt on smooth surfaces and handprints are easily documented as well as powders on textured painted surfaces. Scratches on metal surfaces can be readily separated from other image features. The camera may be useful for tamper indication as surface damage is easy to discern and ambient lighting is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Innovative Low/High Temperature Repetitive Pressure-Pulse Apparatus for Cavitation Damage Research

Material damage due to cavitation can significantly affect the system performance. Thus, it is of great interest to characterize cavitation damage and to improve materials’ resistance to cavitation damage. In this project, a new methodology has been developed to simulate cavitation environment. A pulsed laser is utilized to induce optical breakdown in the cavitation media. Laser plasma expansion is always accompanied by the emission of shock wave and the generation of the bubbles. In general, plasma expands adiabatically at a supersonic velocity, creating high-pressure shock wave in front of it. As the laser plasma cools the shock front rapidly detaches from the plasma because its velocity is much greater than the particle velocity behind it. The pressure waves induced by the optical breakdown fluctuate/propagate within the media, which enables the cavitation to occur and to further develop cavitation damage at the solid boundary. Several prototypes Repetitive Pulsed-Pressure Apparatus (RPPA) were developed. The verification experiments on stainless steel and aluminum samples are carried out both in tap water and distilled water. The key parameters of the cavitation environment, such as pressure and temperature, were calibrated and benchmarked during the experiments. Characteristic cavitation damages such as pitting and indentation are observed on sample surfaces using scanning electron microscopy. The synergistic effect of combining cavitation and the pulse-heating/media-cooling induced thermal cycling fatigue to the target surface damage was also demonstrated in the report.

36 MATERIALS SCIENCE↗

Aircraft measurements of BrO, IO, glyoxal, NO 2 , H 2 O, O 2 –O 2 and aerosol extinction profiles in the tropics: comparison with aircraft-/ship-based in situ and lidar measurements

Here, tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO), iodine monoxide (IO) and small oxygenated hydrocarbons like glyoxal (CHOCHO) in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO 2 ), water vapor (H 2 O) and O 2 –O 2 collision complexes (O 4 ) were measured by the University of Colorado Airborne Multi-AXis Differential Optical Absorption Spectroscopy (CU AMAX-DOAS) instrument, aerosol extinction by high spectral resolution lidar (HSRL), in situ aerosol size distributions by an ultra high sensitivity aerosol spectrometer (UHSAS) and in situ H 2 O by vertical-cavity surface-emitting laser (VCSEL) hygrometer. Data are presented from two research flights (RF12, RF17) aboard the National Science Foundation/National Center for Atmospheric Research Gulfstream V aircraft over the tropical Eastern Pacific Ocean (tEPO) as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO) project (January/February 2012). We assess the accuracy of O 4 slant column density (SCD) measurements in the presence and absence of aerosols. Our O 4 -inferred aerosol extinction profiles at 477 nm agree within 6% with HSRL in the boundary layer and closely resemble the renormalized profile shape of Mie calculations constrained by UHSAS at low (sub-Rayleigh) aerosol extinction in the free troposphere. CU AMAX-DOAS provides a flexible choice of geometry, which we exploit to minimize the SCD in the reference spectrum (SCD REF , maximize signal-to-noise ratio) and to test the robustness of BrO, IO and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01) and provides independent validation data from ship-based in situ cavity-enhanced DOAS and MAX-DOAS. Inside the marine boundary layer (MBL) no BrO was detected (smaller than 0.5 pptv), and 0.2–0.55 pptv IO and 32–36 pptv glyoxal were observed. The near-surface concentrations agree within 30% (IO) and 10% (glyoxal) between ship and aircraft. The BrO concentration strongly increased with altitude to 3.0 pptv at 14.5 km (RF12, 9.1 to 8.6° N; 101.2 to 97.4° W). At 14.5 km, 5–10 pptv NO 2 agree with model predictions and demonstrate good control over separating tropospheric from stratospheric absorbers (NO 2 and BrO). Our profile retrievals have 12–20 degrees of freedom (DoF) and up to 500 m vertical resolution. The tropospheric BrO vertical column density (VCD) was 1.5 × 10 13 molec cm –2 (RF12) and at least 0.5 × 10 13 molec cm –2 (RF17, 0–10 km, lower limit). Tropospheric IO VCDs correspond to 2.1 × 10 12 molec cm –2 (RF12) and 2.5 × 10 12 molec cm –2 (RF17) and glyoxal VCDs of 2.6 × 10 14 molec cm –2 (RF12) and 2.7 × 10 14 molec cm –2 (RF17). Surprisingly, essentially all BrO as well as the dominant IO and glyoxal VCD fraction was located above 2 km (IO: 58 ± 5%, 0.1–0.2 pptv; glyoxal: 52 ± 5%, 3–20 pptv). To our knowledge there are no previous vertically resolved measurements of BrO and glyoxal from aircraft in the tropical free troposphere. The atmospheric implications are briefly discussed. Future studies are necessary to better understand the sources and impacts of free tropospheric halogens and oxygenated hydrocarbons on tropospheric ozone, aerosols, mercury oxidation and the oxidation capacity of the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compiled TBS data from Oliktok Point from ICARUS, AVPOP, and POPEYE

The dataset encompasses QA/QC TBS data, including TBS altitude, atmospheric pressure, dew point, POPs number concentrations and mean aerosol size, relative humidity, temperature, equivalent potential temperature, equivalent temperature, and date and time. These data are provided per day for at least one TBS flight. Supporting data from the AMF3 aligned with the timestamps of the TBS data include cloud base distance from TBS, if the time corresponds to cloud base transit of the TBS, surface-based pressure, surface-based precipitation rate, surface-based UHSAS data, ceilometer cloud base height, KAZR cloud top height, and MWR liquid water content. Both POPS and UHSAS aerosol number concentrations are provided as: (1) absolute (i.e. concentrations for each instrument's total size range) and (2) the overlapping size range (i.e. the same size bins for both instruments).

54 ENVIRONMENTAL SCIENCES↗

TRAC Time Tags of individual particle samples collected for microscopy analysis at RMBL [AMF2] from June 2023 to August 2023

The dataset presents the time tags of individual particle samples collected on microscopy substrates during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in Gothic, CO. A Time Resolved Aerosol Collector was deployed at the Rocky Mountain Biological Laboratory, 200 m north of AMF2 to collect ambient particles. The instrument inlet was placed 5 m above ground level. Particles are deposited on 400 mesh copper carbon-B film TEM grids (Ted Pella 01814-F). Samples are sealed and currently stored at Purdue University. A subset of the samples can be shared. Please contact dataset authors for more information. The dataset reports the sample start times in UTC and MST along with the sample ID, used to guide its location and retrieval from the storage plate. TRAC sampling started on June 17, 2023, and ended on July 31, 2023.

54 ENVIRONMENTAL SCIENCES↗