Ag-LaFeO3 nanoparticles using molecular imprinting technique for selective detection of xylene

Highlights: • Ag-LaFeO{sub 3} based gas sensor using molecular imprinting technique has been successfully applied to the detection of xylene. • Ultrahigh response (resistance ratio = 36.2) to 5 ppm xylene is achieved. • The optimal operating temperature (99 °C) is extremely low. - Abstract: Xylene is a hazardous volatile organic compound, however, the selective detection of ppm-level xylene using oxide semiconductor gas sensor remains a challenging issue. In this study, Ag-LaFeO{sub 3} was modified with molecular imprinting technique, in which methacrylic acid and hydroxyethyl methylacrylate are used as functional monomers, respectively. Based on XRD, EDS, XPS, SEM, TEM, BET nitrogen adsorption observations, the structure and morphology of the samples are characterized. The as-prepared molecularly imprinted nanoparticles with methacrylic acid as functional monomer exhibit high selectivity and response to xylene gas, and the response is dependent on the type and content of the functional monomer. To 5 ppm xylene, the optimal response is 36.2 at the operating temperature of 99 °C. In addition, low cross-responses to the other test gases were observed. The remarkable enhancement in the gas-sensing properties of the samples is attributed to their high specific surface area and molecular imprinting structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

1700 deg C optical temperature sensor

A new gas temperature sensor was developed that shows promise of sufficient ruggedness to be useful as a gas turbine temperature sensor. The sensor is in the form of a single-crystal aluminum oxide ceramic, ground to a cone shape and given an emissive coating. A lens and an optical fiber conduct the thermally emitted light to a remote and near-infrared photodetector assembly. Being optically coupled and passive, the sensor is highly immune to all types of electrical interference. Candidate sensors were analyzed for optical sensor performance, heat transfer characteristics, stress from gas loading. This led to the selection of the conical shape as the most promising for the gas turbine environment. One uncoated and two coated sensing elements were prepared for testing. Testing was conducted to an indicated 1750 C in a propane-air flame. Comparison with the referee optical pyrometer shows an accuracy of + or - 25 C at 1700 C for this initial development. One hundred cycles from room temperature to 1700 C left the sapphire cone intact, but some loss of the platinum, 6% rhodium coating was observed. Several areas for improving the overall performance and durability are identified.

Mossey, P. W.↗

MoO3 Cathodes for High-Temperature Lithium Thin-Film Cells

MoO3 has shown promise as a cathode material that can extend the upper limit of operating temperature of rechargeable lithium thin-film electrochemical cells. Cells of this type are undergoing development for use as energy sources in cellular telephones, wireless medical sensors, and other, similarly sized portable electronic products. The LiCoO2 and LiMn2O4 cathodes heretofore used in these cells exhibit outstanding cycle lives (of the order of hundreds of thousands of cycles) at room temperature, but operation at higher temperatures reduces their cycle lives substantially: for example, at a temperature of 150 C, cells containing LiCoO2 cathodes lose half their capacities in 100 charge/discharge cycles. The superiority of MoO3 as a cathode material was demonstrated in experiments on lithium thin-film cells fabricated on glass slides. Each cell included a layer of Ti (for adhesion to the glass slide), a patterned layer of Pt that served as a cathode current collector, a cathode layer of MoO3, a solid electrolyte layer of Li3.3 PO3.8 N0.22 ("LiPON"), and an anode layer of Li. All the layers were deposited by magnetron sputtering except for the Li layer, which was deposited by thermal evaporation. These cells, along with similar ones containing LiCoO2 cathodes, were subjected to several tests, including measurements of specific capacity in charge/discharge cycling at a temperature of 150 C. The results of these measurements, plotted in the figure, showed that whereas specific capacity of the cells containing LiCoO2 cathodes faded to about half its initial value after only 100 cycles, the specific capacity of the cells containing the MoO3 cathodes faded only slightly during the first few hundred cycles and thereafter not only recovered to its initial value but continued to increase up to at least 5,500 cycles.

West, William↗

Multifunctional skin-like electronics for quantitative, clinical monitoring of cutaneous wound healing

Non-invasive, biomedical devices have the potential to provide important, quantitative data for the assessment of skin diseases and wound healing. Traditional methods either rely on qualitative visual and tactile judgments of a professional and/or data obtained using instrumentation with forms that do not readily allow intimate integration with sensitive skin near a wound site. In this paper, an electronic sensor platform that can softly and reversibly laminate perilesionally at wounds to provide highly accurate, quantitative data of relevance to the management of surgical wound healing is reported. Clinical studies on patients using thermal sensors and actuators in fractal layouts provide precise time-dependent mapping of temperature and thermal conductivity of the skin near the wounds. Analytical and simulation results establish the fundamentals of the sensing modalities, the mechanics of the system, and strategies for optimized design. The use of this type of “epidermal” electronics system in a realistic clinical setting with human subjects establishes a set of practical procedures in disinfection, reuse, and protocols for quantitative measurement. Finally, the results have the potential to address important unmet needs in chronic wound management.

60 APPLIED LIFE SCIENCES↗

Design of the MsAa-4 Moessbauer Spectrometer

An entirely new Moessbauer spectrometer MsAa-4 is currently being under design and construction. New features as compared to the basic features of the previous generation MsAa-3 spectrometer could be summarized as follows. Completely digital processing of the {gamma}-ray detector signal beyond the Gaussian shape filter/amplifier is to be implemented. The spectrometer is going to be able to accommodate external multiple detector heads. Up to 128 {gamma}-ray spectra in 16384 channels of 32-bit each and up to 512 Moessbauer spectra in 4096 channels of 32-bit each could be collected simultaneously, provided the proper external multiple detector head is used. The count-rate per single detector is limited to about 10{sup 5} counts per second in total. Improved precision of the reference function from 12-bit to 16-bit is to be provided. The reference function is stored in 8192 channels per a complete cycle. Addition of the random noise to the reference corner prism of the Michelson-Morley calibration interferometer is to be introduced to avoid spurious fringes due to the phase lock-up. An integrated universal temperature controller being able to use a variety of the temperature sensors is to be interconnected properly with the spectrometer. The spectrometer is now a stand-alone network device as it is equipped with the Ethernet connection to the outside world. Fast and high precision digital oscilloscope is to be incorporated to the spectrometer as the intrinsic unit. This oscilloscope could monitor signals at various crucial points of the internal spectrometer electronics. Modular design and use of the strict standards allows easy reconfiguration for other applications than Moessbauer spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-optic thermometer using Fourier transform spectroscopy

An integrated-optic Mach-Zender interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This configuration provides a high degree of immunity to the effects of changes in the source spectrum, and it readily permits the interrogation of a number of different sensors using a single spectrometer. In addition, this system has a potentially low cost because it uses optical communications hardware that may in the future be manufactured in large quantities.

Beheim, Glenn↗

Simple Creep Test For Ceramic Fibers

Simple bend-stress-relaxation test yields information on creep-related properties of polycrystalline ceramic fibers. Determination of these properties important part of efforts to develop ceramic composite materials that retain mechanical strength and resistance to creep at high temperatures. Present test measures effects of time, temperature, and applied strain on creep-related relaxation of bend stress in ceramic fiber of almost any diameter in almost any environment, without need for contact sensors. Degree of relaxation of bend stress determined from radii of curvature.

Dicarlo, James A.↗

Fiber Optic Sensors for Smart Materials and Structures

In this paper we describe recently developed fiber sensors which are capable of monitoring the health of smart-structures. The unobstrusive geometry of these sensors make them an excellent choice for embedding the sensor in composite materials to measure internal states of strain in structures and materials. Some of these sensors have gage lengths that can be tailored from tens of microns to many meters. We will describe various demodulation schemes (Pseudo-Heterodyne, Synthetic-Heterodyne, Homodyne, Differential-Cross Multiplier, and Single Channel Phase-Tracker) to obtain high bandwidth measurements, enabling measurement of static to high frequency impact generated strains with a dynamic response exceeding tens of thousands of microstrains. In addition, we will show that we can tailor the fiber sensor to either measure only strain and reject temperature response or measure only the temperature, or measure both temperature and strain simultaneously. We will also demonstrate the ability to measure multiple strain components inside a host simultaneously using a single fiber sensor embedded in the host using a certain sensor type and transverse strain immunity using another sensor type. Additionally we will show the ability to measure temperature up to 100 C using fiber optic sensors.

Singh, H.↗

Nanotechnology Concepts at MSFC: Engineering Directorate

Nanotechnology is the art and science of building materials and devices at the ultimate level of finesse: atom by atom. Our nation's space program has needs for miniaturization of components, minimization of weight and maximization of performance, and nanotechnology will help us get there. MSFC - Engineering Directorate (ED) is committed to developing nanotechnology that will enable MSFC missions in space transportation, space science and space optics manufacturing. MSFC-ED has a dedicated group of technologists who are currently developing high pay-off nanotechnology concepts. This poster presentation will outline some of the concepts being developed at this time including, nanophase structural materials, carbon nanotube reinforced metal and polymer matrix composites, nanotube temperature sensors and aerogels. The poster will outline these concepts and discuss associated technical challenges in turning these concepts into real components and systems.

Bhat, Biliyar↗

Role of Process Control in Improving Space Vehicle Safety A Space Shuttle External Tank Example

Developing a safe and reliable space vehicle requires good design and good manufacturing, or in other words "design it right and build it right". A great design can be hard to build or manufacture mainly due to difficulties related to quality. Specifically, process control can be a challenge. As a result, the system suffers from low quality which leads to low reliability and high system risk. The Space Shuttle has experienced some of those cases, but has overcome these difficulties through extensive redesign efforts and process enhancements. One example is the design of the hot gas temperature sensor on the Space Shuttle Main Engine (SSME), which resulted in failure of the sensor in flight and led to a redesign of the sensor. The most recent example is the Space Shuttle External Tank (ET) Thermal Protection System (TPS) reliability issues that contributed to the Columbia accident. As a result, extensive redesign and process enhancement activities have been performed over the last two years to minimize the sensitivities and difficulties of the manual TPS application process.

Safie, Fayssal M.↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

A Compact Electron-Proton Spectrometer for Moon / Mars Surface Space Weather Monitoring and Crew Protection (CEPS)

Small mass/low-power sensors are needed for autonomous Moon/Mars surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. Typical space weather sensors are at least an order of magnitude higher in mass than is expected from Timepix-based devices and are deployed on robotic assets away from human crews. High fidelity measurements at the crew location and subsequent ability are needed to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.​ The aim of this project is the development of compact, low power space weather sensors for crew protection based on the combination of AES flight heritage Timepix hardware with novel CdTe (Cadmium Telluride) sensors. CdTe technology has only recently matured to a point where it can be reliably used with Timepix detectors. These detectors will be able to measure electron spectra in an energy range relevant to the RELEASE model, which is used operationally by NASA to provide crew early warning of Solar Energetic Particle Events as well as protons in the energy ranges relevant to human health allowing for event ‘nowcasting’ and total event crew dose prediction. Compared to existing solutions these detectors will be compact enough to travel with crew, providing a significant advantage to space environment situation awareness. Project results indicate that CdTe-based Timepix sensors respond well to energetic electrons, and particle tracks are sufficiently distinct to be able to measure in a mixed radiation field. Thermal testing results point to a needed design modification to mitigate high temperatures the detector will see in space. Radiation susceptibility testing was conducted to assess the radiation hardness of the CdTe-Timepix assembly. Overall, the assembly continued to operate up to 100 kRad of gamma-ray exposure. The system calibration did show drift over time but recovered once exposure was complete.

Dan James Fry↗

Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets

A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.

Niedra, Janis M.↗

Design and development of a probe-based multiplexed multi-species absorption spectroscopy sensor for characterizing transient gas-parameter distributions in the intake systems of I.C. engines

We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2 O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuring gas temperature, pressure, and H 2 O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.

33 ADVANCED PROPULSION SYSTEMS↗

Structural, optical and gas sensing properties of vertically well-aligned ZnO nanowires grown on graphene/Si substrate by thermal evaporation method

Highlights: • Vertically well-aligned ZnO NW arrays with high aspect ratio and extremely large-surface-volume ratio were synthesized on graphene/Si substrate without the aid of metal catalyst by a simple thermal evaporation. • The gas sensor based on the vertical ZnO NW arrays-graphene structure exhibited high sensitivity and rapid response/recovery characteristics to NO{sub 2} gas at 200oC, and could be used to detect NO{sub 2} gas at very low levels (2, 6, 10 ppm). • The excellent sensing performance is mainly because of the large specific surface area and the presence of oxygen-vacancies at the surface of ZnO NWs, together with the creation of p-n heterojunctions between n-type ZnO NW and p-type graphene. • The common defects and optical properties of the ZnO NW arrays-graphene structure were studied in detail. • The possible growth mechanism of vertically well-aligned ZnO NWs on graphene and the gas-sensing mechanism of sensors were proposed. - Abstract: We report catalyst-free vertical growth of high-density ZnO nanowire (NW) arrays on Si substrate with a graphene buffer layer by thermal evaporation method. Structural, surface morphology, chemical composition and optical properties of ZnO NWs were studied by Field emission scanning electron microscopy (FE-SEM), High-resolution transmission electron microscopy (HR-TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), photoluminescence (PL) and Raman spectroscopy. The results indicate that the grown ZnO NWs are single-crystalline and exhibit the hexagonal wurtzite crystal structure with a preferred orientation along the [0001] direction; all of the ZnO NWs vertically grow on the graphene/Si substrate. The majority of the as-grown NWs have diameters in the range of 250–300 nm and length up to several tens of micrometers, whereas a small portion of NWs have a diameter of approximately of 9–12 nm. Room temperature PL spectrum of the ZnO NWs exhibits a sharp and strong ultraviolet emission at 380 nm and a weak visible emission at around 516 nm. The role of graphene buffer layer in the vertical-aligned ZnO NW arrays growth and its improved optical properties is demonstrated. Importantly, the gas sensor based on these ZnO NWs exhibits high sensitivity and rapid response/recovery characteristics to NO{sub 2} gas at 200 °C, and can detect NO{sub 2} concentration as low as 2, 6 and 10 ppm. The excellent sensing performance is mainly due to the combination of the large specific surface area and the presence of oxygen-vacancies at the surface of ZnO NWs, together with the creation of p-n heterojunctions between n-type ZnO NW and p-type graphene. Such a ZnO NW/graphene structure is very promising for various applications, such as photonic, optoelectronic and sensor devices. In addition, the possible growth mechanism and the NO{sub 2} sensing gas mechanism of the ZnO NWs-graphene structure have been discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers

Compact, highly efficient, 3.0 to 3.4 m light emitters are in demand for spectroscopic analysis and identification of chemical substances (including methane and formaldehyde), infrared countermeasures technologies, and development of advanced infrared scene projectors. The need for these light emitters can be currently addressed either by bulky solid-state light emitters with limited power conversion efficiency, or cooled Interband Cascade (IC) semiconductor lasers. Researchers here have developed a breakthrough approach to fabrication of diode mid-IR lasers that have several advantages over IC lasers used for the Mars 2009 mission. This breakthrough is due to a novel design utilizing the strain-engineered quantum-well (QW) active region and quinternary barriers, and due to optimization of device material composition and growth conditions (growth temperatures and rates). However, in their present form, these GaSb-based laser diodes cannot be directly used as a part of sensor systems. The device spectrum is too broad to perform spectroscopic analysis of gas species, and operating currents and voltages are too high. In the current work, the emitters were fabricated as narrow-ridge waveguide index-guided lasers rather than broad stripe-gain guided multimode Fabry-Perot (FP) lasers as was done previously. These narrow-ridge waveguide mid-IR lasers exhibit much lower power consumptions, and can operate in a single spatial mode that is necessary for demonstration of single-mode distributed feedback (DBF) devices for spectroscopic applications. These lasers will enable a new generation of compact, tunable diode laser spectrometers with lower power consumption, reduced complexity, and significantly reduced development costs. These lasers can be used for the detection of HCN, C2H2, methane, and ethane.

Frez, Clifford F.↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Synthesis and Characterization of a New Ferroelectric with Low Lead Content, a High Curie Temperature, and a High Piezoelectric Response

Abstract A new solid solution (1− x )Bi(Fe 2/8 Ti 3/8 Mg 3/8 )O 3 –( x )PbTiO 3 (BFTM‐PT) is synthesized and the electromechanical properties are measured. This system is defined as a low‐lead material with ferroelectric/piezoelectric behavior and a morphotropic phase boundary (MPB) that leads to enhanced properties. The MPB is located between x = 0.30 and 0.35 and coincides with a structural phase transition and a sharp increase in the piezoelectric response. The system demonstrates ferroelectric hysteresis where x = 0.325 displays the best properties with a maximum polarization of 39 µC cm −2 and a remnant polarization of 26 µC cm −2 . The range of compositions has high Curie temperature ( T c ), ranging from 625–650 °C. Materials with a T c above 400 °C typically have a low d 33 of <50 pC N −1 at room temperature. However, BFTM‐PT has a higher d 33 that most other compositions with a T c in this range, with the highest being 145 pC N −1 for x = 0.375. The d 33 drops off above 100 °C, but doping studies can be done in the future to stabilize the piezoelectric response at higher temperatures. These outstanding properties open the possibility of new transducer applications, in particular ones requiring high temperature and high power.