Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Three-dimensional nanomagnetism

Magnetic nanostructures are being developed for use in many aspects of our daily life, spanning areas such as data storage, sensing and biomedicine. Whereas patterned nanomagnets are traditionally two-dimensional planar structures, recent work is expanding nanomagnetism into three dimensions; a move triggered by the advance of unconventional synthesis methods and the discovery of new magnetic effects. In three-dimensional nanomagnets more complex magnetic configurations become possible, many with unprecedented properties. Here we review the creation of these structures and their implications for the emergence of new physics, the development of instrumentation and computational methods, and exploitation in numerous applications.

36 MATERIALS SCIENCE↗

Contactless excitation of acoustic resonance in insulating wafers

Contactless excitation and detection of high harmonic acoustic overtones in a thin insulator single crystal are described using radio frequency spectroscopy techniques. Single crystal [001] silicon wafer samples were investigated, one side covered with a Nb thin film, the common starting point for the fabrication of quantum devices. Additionally, the coupling between electromagnetic signals and mechanical oscillation is achieved from the Lorentz force generated by an external magnetic field. This method is suitable for any sample with a metallic surface or covered with a thin metal film. High resolution measurements of the temperature dependence of the sound velocity and elastic constants of silicon are reported and compared with known results.

47 OTHER INSTRUMENTATION↗

Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T

The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which varies from 0.2 to 0.35 T in different regimes of operation. Buildup of 15 keV ion population generates a diamagnetic reduction of magnetic field in the plasma core of up to 30% in the maximum density region, as measured by the existing eight-line MSE diagnostic. Commissioning of the midplane MSE provided first direct measurements of diamagnetic modifications in the minimum magnetic field GDT section, a necessary complement to the understanding of equilibrium and self-organization of high-β plasmas in GDT. Making use of the stable short-pulse diagnostic beam and calibration of the apparent spectral width of beam emission lines allow for the measurement of the plasma magnetic field of 0.29 ± 0.007 T with the integration time of 200 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopy image segmentation tool: Robust image data analysis

We present a software package called Microscopy Image Segmentation Tool (MIST). MIST is designed for analysis of microscopy images which contain large collections of small regions of interest (ROIs). Originally developed for analysis of porous anodic alumina scanning electron images, MIST capabilities have been expanded to allow use in a large variety of problems including analysis of biological tissue, inorganic and organic film grain structure, as well as nano- and meso-scopic structures. MIST provides a robust segmentation algorithm for the ROIs, includes many useful analysis capabilities, and is highly flexible allowing incorporation of specialized user developed analysis. We describe the unique advantages MIST has over existing analysis software. In addition, we present a number of diverse applications to scanning electron microscopy, atomic force microscopy, magnetic force microscopy, scanning tunneling microscopy, and fluorescent confocal laser scanning microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt arrival of solar energetic particles from far eastern events - The role of large-scale interplanetary magnetic field structure

Intensity-time profiles of solar energetic particle enhancements generally show an asymmetry with respect to the heliolongitude of the associated solar event. Particles arrive promptly from events to the west of an observer because of good magnetic connection, whereas particle enhancements from poorly connected eastern source regions usually show much slower onsets. However, some 15 percent of eastern events do show prompt onsets. Two prompt particle enhancements associated with eastern solar events are studied using data from the Goddard Space Flight Center instruments on the ISEE 3 and IMP 8 spacecraft. In both events the prompt particle onset was observed when the spacecraft were in a postshock plasma region, apparently within a magnetic bottle. It is suggested that the magnetic bottle extended back to the sun and served as a channel for fast particle propagation to the spacecraft. Particles accelerated at an expanding coronal shock initiated by the eastern event could be injected onto field lines in the foot of the bottle.

Richardson, I. G.↗

CORONAL SEISMOLOGY USING EIT WAVES: ESTIMATION OF THE CORONAL MAGNETIC FIELD STRENGTH IN THE QUIET SUN

Coronal EIT waves have been observed for many years. The nature of EIT waves is still contentious, however, there is strong evidence that some of them might be fast magnetosonic waves, or at least have a fast magnetosonic wave component. The fast magnetosonic wave speed is formed from two components; the Alfven speed (magnetic) and the sound speed (thermal). By making measurements of the wave speed, coronal density and temperature it is possible to calculate the quiet-Sun coronal magnetic field strength through coronal seismology. In this paper, we investigate an EIT wave observed on 2009 February 13 by the SECCHI/EUVI instruments on board the STEREO satellites. The wave epicenter was observed at disk center in the STEREO B (Behind) satellite. At this time, the STEREO satellites were separated by approximately 90 deg., and as a consequence the STEREO A (Ahead) satellite observed the wave on the solar limb. These observations allowed us to make accurate speed measurements of the wave. The background coronal density was derived through Hinode/Extreme-ultraviolet Imaging Spectrometer observations of the quiet Sun and the temperature was estimated through the narrow temperature response in the EUVI bandpasses. The density, temperature, and speed measurements allowed us to estimate the quiet-Sun coronal magnetic field strength to be approximately 0.7 {+-} 0.7 G.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ baking method for degassing of a kicker magnet in accelerator beam line

In this study, the authors propose a new in situ degassing method by which only kicker magnets in the accelerator beam line are baked out without raising the temperature of the vacuum chamber to prevent unwanted thermal expansion of the chamber. By simply installing the heater and thermal radiation shield plates between the kicker magnet and the chamber wall, most of the heat flux from the heater directs toward the kicker magnet. The result of the verification test showed that each part of the kicker magnet was heated to above the target temperature with a small rise in the vacuum chamber temperature. A graphite heater was selected in this application to bake-out the kicker magnet in the beam line to ensure reliability and easy maintainability of the heater. The vacuum characteristics of graphite were suitable for heater operation in the beam line. A preliminary heat-up test conducted in the accelerator beam line also showed that each part of the kicker magnet was successfully heated and that thermal expansion of the chamber was negligibly small.

43 PARTICLE ACCELERATORS↗

Measurement of magnetic field using Rayleigh backscattering in optical fibres

In this paper, we investigate the use of optical reflectometry in optical fibres for the measurement of magnetic field. The dedicated application concerns the measurement of plasma current in the fusion reactor. The measurement is based on the rotation of the polarization state of the Rayleigh backscattered signal when an optical pulse is launched in the fibre. Particular care has been undertaken to evaluate the impact of linear birefringence on the measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The polar solar wind: An additional acceleration due to the rotation of the magnetic sun

The influence of the solar rotation of the polar solar wind acceleration was analyzed theoretically. Data from the Solar and Heliospheric Observatory (SOHO) ultraviolet instruments were used to test the theoretical predictions. These predictions are: the double electric layer at the heliocentric distance of 2.6 solar radii, and the system of field-aligned electric currents above 2.6 solar radii. The model provides a 3D analytical discontinuous stationary solution of the magnetohydrodynamic equations in the non-inertial frame of reference.

Pisanko, Y. V.↗

Microwave remote plasma enhanced-atomic layer deposition system with multicusp confinement chamber

A microwave remote Plasma Enhanced-Atomic Layer Deposition system with multicusp confinement chamber is established at the Plasma and Beam Physics research facilities, Chiang Mai, Thailand. The system produces highly-reactive plasma species in order to enhance the deposition process of thin films. The addition of the multicusp magnetic fields further improves the plasma density and uniformity in the reaction chamber. Thus, the system is more favorable to temperature-sensitive substrates when heating becomes unwanted. Furthermore, the remote-plasma feature, which is generated via microwave power source, offers tunability of the plasma properties separately from the process. As a result, the system provides high flexibility in choice of materials and design experiments, particularly for low-temperature applications. Performance evaluations of the system were carried on coating experiments of Al{sub 2}O{sub 3} layers onto a silicon wafer. The plasma characteristics in the chamber will be described. The resulted Al{sub 2}O{sub 3} films—analyzed by Rutherford Backscattering Spectrometry in channeling mode and by X-ray Photoelectron Spectroscopy techniques—will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent development of plasma optical systems (invited)

The article devotes a brief description of the recent development and current status of an ongoing research of plasma optical systems based on the fundamental plasma optical idea magnetic electron isolation, equipotentialization magnetic field lines, and the axi-symmetric cylindrical electrostatic plasma lens (PL) configuration. The experimental, theoretical, and simulation investigations have been carried out over recent years collaboratively between IP NASU (Kiev), LBNL (Berkeley, USA), and HCEI RAS (Tomsk). The crossed electric and magnetic fields inherent the PL configuration that provides the attractive method for establishing a stable plasma discharge at low pressure. Using PL configuration, several high reliability plasma devices were developed. These devices are attractive for many high-tech applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-beamlet investigation of the deflection compensation methods of SPIDER beamlets

SPIDER (Source for Production of Ions of Deuterium Extracted from a Rf plasma) is an ion source test bed designed to extract and accelerate a negative ion current up to 40 A and 100 kV whose first beam is expected by the end of 2016. Two main effects perturb beamlet optics during the acceleration stage: space charge repulsion and the deflection induced by the permanent magnets (called co-extracted electron suppression magnets) embedded in the EG. The purpose of this work is to evaluate and compare benefits, collateral effects, and limitations of electrical and magnetic compensation methods for beamlet deflection. The study of these methods has been carried out by means of numerical modeling tools: multi-beamlet simulations have been performed for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical and Magnetic Properties of Ultrathin Polycrystalline Fe Films Grown on SiO{sub 2}/Si(001)

Ultrathin polycrystalline Fe films have been grown on the oxidized surface of a Si(001) substrate. The resistivity and magnetic hysteresis of Fe films have been measured in the range of thickness from 2.5 to 10 nm. Based on the analysis of the data obtained, it is suggested that there is a transition to the structurally continuous film at a thickness of ~6 nm. It is found that Fe grains in this film acquire the preferred (111) orientation during this transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of intermediate-frequency electric and magnetic fields in households

Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ{sub E} 1.0 and {sub E}Q{sub H} 0.13). - Highlights: • Survey of residential electric and magnetic fields at intermediate frequencies (IF). • IF-EF and -MF emitted by 280 household appliances were characterised. • Strongest emitters were induction cookers, CFLs, LCD-TVs, and microwave ovens. • No emissions exceeded ICNIRP limits (highest exposure quotient was 1.00).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Solenoid With Partial Yoke for the Dune Near Detector

The Deep Underground Neutrino Experiment (DUNE) at Fermilab is one the most challenging next-generation experiments in the field of neutrino physics. It will feature two detectors for a detailed study of neutrino oscillations using an unprecedentedly intense neutrino beam. The two detectors are a Near Detector located on the Fermilab site, 574 m away from the neutrino generation, and a Far Detector in South Dakota, 1300 km away. The Near Detector consists of three subdetectors, based on different technologies in order to achieve the best understanding of the neutrino beam. One key element of the Near Detector is a High Pressure Argon TPC surrounded by a calorimeter. This detector will need a 0.5 Tesla magnetic field transverse to the neutrino beam direction, with a 7 m diameter, 8 m long warm bore. A thin superconducting solenoid with a partial yoke, needed in order to minimise the amount of material along the path particles take crossing the different elements of the Near Detector is proposed. In this paper we present a detailed magnetic analysis and a preliminary study of the cooling, the cable and the mechanics for this magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis

Modern microelectronics life-cycle and supply chain ecosystem bring multiple untrusted entities, which can compromise their integrity. A major integrity issue of microelectronics stems from piracy of intellectual properties (IP) and counterfeiting, which causes significant revenue loss to the semiconductor manufacturers. Further, these components often lead to compromised functionality, reliability, security, and safety of an electronic system. This paper presents secure information transmission and probing methods for verifying the integrity of digital integrated circuit (ICs) based on their electromagnetic (EM) near-field emissions and thereby protecting systems against counterfeit components. The proposed method has been tested on both high-level instructions executed by microprocessors or Systems-on-Chip (serving as examples of software), and also logic circuits within FPGA fabrics and ASICs (serving as examples of hardware). The authentication information required by each digital system is generated using a pseudo-random number generator circuit and securely transmitted via near-field magnetic emissions. The authorized party can probe these emissions using a near-field probe, process the acquired signals to improve the signal-to-noise ratio (SNR), and then recover the secure information through matched filtering. Experimental results from commercial SoCs are used to demonstrate the proposed technique. Methods for reducing EM interference during integrity verification of both FPGAs and ASICs are also described.

47 OTHER INSTRUMENTATION↗

Trapping of Electron Cloud LLC/Cesrta Quadrupole and Sextupole Magnets

The Cornell Electron Storage Ring (CESR) has been reconfigured as an ultra low emittance damping ring for use as a test accelerator (CesrTA) for International Linear Collider (ILC) damping ring R&D [1]. One of the primary goals of the CesrTA program is to investigate the interaction of the electron cloud with low emittance positron beam to explore methods to suppress the electron cloud, develop suitable advanced instrumentation required for these experimental studies and benchmark predictions by simulation codes. This paper reports the simulation of the electron-cloud formation in CESRTA and ILC quadrupole and sextupole magnets using the 3D code CLOUDLAND. We found that electrons can be trapped with a long lifetime in a quadrupole and sextupole magnet due to the mirror field trapping mechanism. We study the effects of magnet strength, bunch current, ante-chamber effect, bunch spacing effect and secondary emission yield (SEY) in great detail. The development of an electron cloud in magnets is the main concern where a weak solenoid field is not effective. Quadrupole and sextupole magnets have mirror field configurations which may trap electrons by the mirror field trapping mechanism [2]. Fig.1 shows the orbit of a trapped electron in a quadrupole magnet. The electron makes gyration motion (called transverse motion) and also moves along the field line (called longitudinal motion). At the mirror point (middle of the field line), there is a maximum longitudinal energy and minimum transverse energy. When the electron moves away from the mirror point, its longitudinal energy reduces and the transverse energy increases as the magnetic field increases. If the magnetic field is strong enough, the longitudinal energy becomes zero at one point and then the electron is turned back by the strong field. Note that the electrons are trapped in the region near the middle of the field lines. Although all quadrupole and sextupole magnets can trap electrons in principle, the trapping mechanism is also greatly sensitive to the detail dynamics of the electrons [3]. Both the positron beam and the spacing charge force of electron cloud itself play important roles. This paper reports the simulation of electron cloud in CESRTA/ILC quadrupole and sextupole magnets. Table 1 shows the main parameters used in the simulation.

43 PARTICLE ACCELERATORS↗

In situ biaxial rotation at low-temperatures in high magnetic fields

We report the design, construction, and characterization of a biaxial sample rotation stage for use in a cryogenic system for orientation-dependent studies of anisotropic electronic transport phenomena at low temperatures and high magnetic fields. Our apparatus allows for continuous rotation of a sample about two axes, both independently and simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗