Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrically”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Opportunities for Integrating Electric and Gas Planning

Growing demand for electricity in buildings is creating new opportunities and challenges for electric and natural gas planning. To date, electric and gas planning processes have largely been siloed, and only a few jurisdictions have started to examine how these two processes could be linked together. The report explores the current state of electric and gas system planning, and the benefits and challenges of integrating these planning processes. We frame the characteristics of an integrated electric and gas distribution planning process and identify indicators of progress toward the characteristics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Future Electric Power Industry and Grids—Now What Again is Our Destination?

Having a vision that others agree to support and work toward is highly desirable but hard to achieve. We seem to lack a common and shared understanding of the vision—or worse, multiple visions (vivid mental images or documented statements) with varying areas of focus and details: • some appear to be similar but have differing underlying goals and characteristics, or • some reflect differing viewpoints as to effects on various stakeholders. These desirable and undesirable situations apply to realizing visions for enterprise and industry, including the electricity sector. Multiple industry stakeholder groups have developed goals, industry vision statements, and characterizations of the future. The viewpoints are promoted, discussed, refined by their stakeholder group, and often published to promote broad understanding and to inform or influence others. The GridWise Architecture Council asked itself how well-aligned these characterizations of the future are. If these publications collectively set the overall direction for the industry, it is useful to identify their answers to questions such as, where is the electric industry headed, guided by what objectives, and with what role(s) for the customers, electric utilities, and other stakeholders? Are these goals, visions, and future states moving toward a common vision, do they provide value for the stakeholders, and are they likely to meet the objective stated? This paper addresses these questions via an assessment and characterization of a sampling of stakeholder groups’ publicly available vision and future state reports for the electricity industry. Identified electric power grid architectural topic areas needing further work are described, along with GridWise Architecture Council analysis and observation, potential collaborative work efforts, and suggested next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Device- and System-Level Thermal Packaging for Electric-Drive Technologies (Final Technical Report)

Final Technical ReportThis project aimed to research, develop, and test electric traction drive system technology for use in vehicle applications that are capable of meeting the targets set by the Department of Energy Vehicle Technologies Office. The project is categorized into three major thrusts: Bonding interfaces for packaging, thermal management of electric vehicle (EV) power inverters, and electric motor thermal management. Device- and System-Level Thermal Packaging for Electric-Drive Technologies project aimed to develop, analyze, and validate transformative approaches in thermal management and packaging for power electronics and electric motor systems, with the ultimate goal of enhancing power density, efficiency, and reliability in electrified transportation platforms.

33 ADVANCED PROPULSION SYSTEMS↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Next-Generation Electric Motors and Electromagnetic Devices (CRADA Final Report)

As part of the Cyclotron Road program, the Foli Research team investigated electric motors and other electromagnetic devices additively manufactured by depositing fine conducting wire onto a substrate. By leveraging modern motion control and efficient upstream manufacturing processes, the team explored using geometric control and turnkey production comparable to printed circuit board manufacturing, aiming at ten-fold improvements in signal density, while eliminating the material use, cost, and complexity overheads of subtractive processes at large scales. Owing to the achievable density and additive scaling, disparate components became monolithic, and disparate processes were combined with the aim of reducing development costs, uncertainties, and timelines. When applied to electric motors, this technology may enable agile manufacturing of next-generation designs, with dramatic increases in achievable power density and material utilization. Electric motors represent the single largest user of electricity in the U.S. and a critical component of decarbonized infrastructure. Despite this significance, the manufacturing of motors and other electromagnetic devices remains capital-intensive, labor-intensive, and performance-limiting. Advanced manufacturing processes were required to produce high-performance, low-cost, application-specific electric motors and electromagnetic devices to support an electrified future.

42 ENGINEERING↗

Xcel Energy’s electric carbon emissions reduction trajectories in the context of 1.5°C and 2°C warming pathways

In 2015 the Paris Agreement established the goals of limiting global average warming to well below 2°C and pursuing efforts to limit warming to below 1.5°C. A large and growing number of scenarios have been developed by the climate research community that explore global energy and emissions pathways that would achieve those goals. We draw on the most recent database of such scenarios to update a previous analysis of Xcel Energy’s emissions reduction goals in light of evolving climate science. We assess the outlook for the role of the US electricity sector in current economy-wide and global emissions pathways and compare it to Xcel Energy’s near-term resource plans to 2030. We find that global scenarios that achieve the 1.5°C goal span a range of US/North America electricity sector emissions reductions by 2030 of about 65-85%. Xcel Energy’s emissions reductions to date have exceeded those of the US electricity sector as a whole, and its projected trajectory to 2030 under current approved resource plans falls within this range. Scenarios achieving the 2°C goal have a wider range of reductions (about 40-85%). In scenarios achieving either goal, electricity sector emissions fall faster than economy-wide emissions, a robust feature of mitigation scenarios, which typically rely on low carbon electricity to achieve climate targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Harvesting Subsea Water Motion to Provide Clean Electrical Power

This TEAMER project had three main objectives related to characterizing the performance of a vortex-induced vibration (VIV) marine energy harvesting device called the Whatever Input To Torsion (WITT). The first was to characterize the motion of the WITT device as it vibrates on top of a pipe in a natural tidal flow. The second was to measure how much electricity the WITT device generates when it is deployed on top of a pipe that is secured to the seabed with a lander. The third objective was to measure how much electricity the WITT device generates in the same configuration but with a longer pipe. This TEAMER project succeeded in satisfying the first objective by measuring the motion of the WITT device with an inertial measurement unit (IMU) mounted in the WITT housing. The motion was described by examining changes in the acceleration, pitch, roll, and yaw, and displacement. The frequency of the motion was characterized using spectral analysis. The TEAMER project succeeded in reaching the second objective by measuring the power produced by the WITT. It is reported here as the average and maximum power in hourly intervals. WITT Energy decided to not have us pursue the third objective of testing a longer pipe because the first test was unexpectedly successful at having the system vibrate at the target frequency. A longer pipe would have resulted in a decreased frequency and therefore not have been a useful test. Based on these findings, the decision was made to keep the same pipe length for both tests and improve on other aspects of the test structure that had failed during the first test. The key finding of this TEAMER project is that the WITT is capable of generating electricity in moderate flow speeds when it is in a housing that is attached to a 2.5 m pipe and secured to the seabed by a lander. This report contains the first power values for a VIV instrument that generates electricity from a pendulum swinging at the top of a long pipe. The experiment demonstrated that the vibration frequency of the device varied with the tidal current speed, which changed throughout a given tidal cycle. This meant that the desired peak frequency was not sustained for more than one hour. The success of this TEAMER test provides evidence that continued research in the area of electricity generation from VIV holds promise as a source of marine energy for offshore applications. Future tests should focus on refining the pipe length equations and improving the power take off system of the WITT power electronics. In addition, experiments aimed at expanded testing and evaluation (e.g. longer than one month) are needed to measure the power production at higher tidal current speeds and test the system's durability.

Branch, Ruth A. (ORCID:0000000202356719)↗

Data-Driven Probabilistic Anomaly Detection for Electricity Market under Cyber Attacks

Information and communication technologies have been widely used in smart grid for efficient operation. However, these technologies are vulnerable to malicious cyber attacks, which may lead to severe reliability and economic issues. Recently, a variety of data-driven anomaly detection approaches have been explored to detect potential cyber attacks in smart grids. In this paper, we researched on the electricity market data aiming to identify anomalies from the locational marginal prices (LMPs) and provide a new indicator for potential cyber attacks in power grids. Specifically, a novel data-driven probabilistic anomaly detection framework is proposed for electricity market, which consists of three major components: long short-term memory (LSTM) based deterministic electricity price forecasting, probabilistic electricity price forecasting and anomaly detection. This framework is tested on a model-based electricity market simulator under two types of cyber attacks, i.e., load redistribution attack (LRA) and price responsive attack (PRA). Numerical results on the simulated LMPs show that the proposed framework is capable of detecting data anomalies over these attacks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microstructure, electrical resistivity, and tensile properties of neutron-irradiated Cu–Cr–Nb–Zr

High strength, high conductivity copper alloys that can resist creep at high temperatures are one of the primary candidates for efficient heat exchangers in fusion reactors. Cu–Cr–Nb–Zr (CCNZ) alloys, which were designed to improve the strength and creep life of ITER Cu–Cr–Zr (CCZ) reference alloys, have been found to have comparable electrical conductivity and tensile properties to CCZ alloys. The measured creep rupture times for these improved alloys is about ten times higher than the ITER reference alloys at 90–125 MPa at 500 °C. However, the effects of neutron irradiation on these alloys, and the ensuing material properties, have not been studied; thus, their utility in a fusion reactor environment is not well understood. This study characterizes the room temperature mechanical and electrical properties of a neutron-irradiated CCNZ alloy and compares them to a neutron-irradiated ITER reference heat sink CCZ alloy. Tensile specimens were neutron irradiated in the High Flux Isotope Reactor (HFIR) to 5 dpa between 250 °C and 325 °C. Post-irradiation characterization included electrical resistivity measurements, hardness, and tensile tests. Microstructural evaluation used scanning electron microscopy, energy dispersive x-ray spectroscopy, and atom probe tomography to characterize the irradiation-produced changes in the microstructure and investigate the mechanistic processes leading to post-irradiation properties. Transmutation calculations were validated with composition measurements from atom probe data and used to calculate contributions to the increased electrical resistivity measured after irradiation. Comparisons with CCZ alloys in the same irradiation heat found that the post-irradiated CCNZ and CCZ alloys had comparable electrical resistivity. Although CCNZ alloys suffered more irradiation hardening than CCZ, the overall tensile behavior deviated very little from non-irradiated values in the temperature range studied.

36 MATERIALS SCIENCE↗

Systemic Drivers of Electric-Grid-Caused Catastrophic Wildfires: Implications for Resilience in the United States

Wildfires are projected to increase in severity and frequency due to climate change, and the electric grid is both a cause of wildfires and is vulnerable to wildfires. Equipment from the electric grid accounts for 10% of fires burned in California and 3% of fires nationally. Recent catastrophic wildfires, such as the Lahaina Fire, Camp Fire, Marshall Fire, and Smokehouse Creek fires, were all started by electrical equipment and show how devastating these events can be because they threaten lives and structures. Vegetation structure, weather and winds, climate and vegetation response, land use, and human activities all impact the likelihood of severe wildfires. We explore the relationship between the built environment, electric grid infrastructure specifically, and its role in causing catastrophic wildfires to find lessons learned for increasing resilience. Electric grid utility companies currently employ multiple methods to mitigate fire, including (1) early detection, (2) grid hardening, (3) vegetation management, and (4) pre-emptive shutoffs. Utility companies need to consider the conditions for wildfire and the impact that each mitigation strategy has on drivers of wildfire behavior, as a single solution will not be adequate. Utility companies need to work with stakeholders to develop a holistic strategy to reduce ignition likelihood and spread likelihood to reduce catastrophic wildfires and improve resiliency.

Eagleston, Holly (ORCID:0000000178175116)↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light-duty Plug-in Electric Vehicles in China: Evolution, Competition, and Outlook

China's plug-in electric vehicle (PEV) market with stocks at 7.8 million is the world's largest in 2021, and it accounts for half of the global PEV growth in 2021. The PEV market in China has dramatically evolved since the pandemic in 2020: over 20% of all new PEV sales are from China by mid-2022. Recent features of PEV market dynamics, consumer acceptance, policies, and infrastructure have important implications for both the global energy market and manufacturing stakeholders. From the perspective of demand pull-supply push, this study analyzes China's PEV industry with a market dynamics framework by reviewing sales, product and brand, infrastructure, and government policies from the last few years and outlooking the development of the new government’s 14th Five-Year Plan (2021-2025). From the demand side, small-sized sedans and compact sport utility vehicles with increased electric ranges are both popular for PEVs, and the electric range of over 60% of new battery electric vehicles in 2021 has been longer than 400 km. From the supply side, although foreign brands like Tesla are still competitive, the products by Chinese domestic automakers like BYD are becoming more attractive and cannibalizing the high-end market. However, the production capacity and cost of PEVs may be limited by the upstream of the supply chain – the battery manufacturing and supply chain inflation. In addition, it is also uncertain how much sales demand impacts will be caused by the potential global economic recession. The government firmly supports electrification and decarbonization of the vehicle industry by emphasizing the importance of the vehicle industry for promoting the greenhouse gas net zero by 2060. The dual-credit policy is regarded as the most critical regulation in a bid to restrain fuel consumption and promote PEV share. Still, the market is facing some technological obstacles, such as battery safety and driving range anxiety, before real prosperity. In addition, the Chinese electric vehicle market is seeing a trend toward the development of new technologies such as vehicle-to-X, autonomous driving, and connected vehicles.

Hao, Xu↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

The generation of pollution-free electrical power from solar energy.

Projections of the U.S. electrical power demands over the next 30 years indicate that the U.S. could be in grave danger from power shortages, undesirable effluence, and thermal pollution. An appraisal of nonconventional methods of producing electrical power is conducted, giving particular attention to the conversion of solar energy into commercial quantities of electrical power by solar cells. It is found that 1% of the land area of the 48 states could provide the total electrical power requirements of the U.S. in the year 1990. The ultimate method of generating vast quantities of electrical power would be from a series of synchronous satellites which beam microwave power back to earth to be used wherever needed. Present high manufacturing costs of solar cells could be substantially reduced by using massive automated techniques employing abundant low cost materials.

Cherry, W. R.↗

Electric fields in the ionosphere and magnetosphere.

Review of current techniques for measuring ionospheric and magnetospheric electric fields and existing measurements. Considerable progress in understanding electric fields has been made in the auroral regions where fields originating basically from convection patterns in the magnetosphere and modified by ionospheric interaction have been detected by both the barium ion cloud and double floating probe techniques and have been compared against predictions. The anticorrelation of electric fields and auroral arcs, the establishment of the auroral electrojet currents as Hall currents, the irregular nature of the electric fields, and the reversal of the electric fields between the eastward and westward electrojet regions have been some of the important observations. Recent barium ion cloud observations in the polar cap have indicated that the long assumed electrojet return current across the polar cap does not exist.

Maynard, N. C.↗