Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Dakota, A Multilevel Parallel Object-Oriented Framework for Design Optimization, Parameter Estimation, Uncertainty Quantification, and Sensitivity Analysis (V.6.16 User's Manual)

The Dakota toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. Dakota contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the Dakota toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a user's manual for the Dakota software and provides capability overviews and procedures for software execution, as well as a variety of example studies.

97 MATHEMATICS AND COMPUTING↗

Dakota, A Multilevel Parallel Object-Oriented Framework for Design Optimization, Parameter Estimation, Uncertainty Quantification, and Sensitivity Analysis: Version 6.16 Theory Manual

The Dakota toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. Dakota contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the Dakota toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a theoretical manual for selected algorithms implemented within the Dakota software. It is not intended as a comprehensive theoretical treatment, since a number of existing texts cover general optimization theory, statistical analysis, and other introductory topics. Rather, this manual is intended to summarize a set of Dakota-related research publications in the areas of surrogate-based optimization, uncertainty quantification, and optimization under uncertainty that provide the foundation for many of Dakota’s iterative analysis capabilities.

97 MATHEMATICS AND COMPUTING↗

The role of time and speed in NASA's SUNLITE program

The SUNLITE program of NASA's LaRC aims to demonstrate lower noise and better frequency stability for continuous-wave (CW) solid-state lasers in the microgravity environment of space. The program will utilize laser-diode-pumped nonplanar-ring oscillators regulated by ultra-stable high-finesse Fabry-Perot Spectrometers to produce light beams with phase rate or frequency variations as low as 3 Hz. SUNLITE will use the period-method (P-method) to measure the phase rate and frequency stability of the lasers. The P-method was chosen because it requires less memory space for the raw data, because frequencies can be analyzed on-line in real-time simply by reciprocating the periods (fi = 1/pi), and because the mean and variance of the frequencies can be calculated as fast or faster than they can be with the fastest fast Fourier transformations. Furthermore, for a given signal-to-noise power ratio, the P-method requires less data and less computer time to extract the noise components. Although the P-method does require fast Time Interval Counters, the Fourier transformation method requires comparably fast Sampling Volt meters. For either method, however, time and computer speed play a critical role.

Hafele, Joseph C.↗

Global analysis peak fitting for chemical spectroscopy data

The present invention relates to methods for analyzing a chemical sample. For instance, the methods herein allow for global analysis of spectroscopy data in order to extract useful chemical properties from complicated multidimensional data. Such analysis can optionally employ data compression to further expedite computer-implemented computation. In particular, the methods herein provide global analysis of data matrices explained by both linear and non-linear terms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Several methods for concentrating bacteria in fluid samples

The sensitivities of the firefly luciferase - ATP flow system and luminol flow system were established as 300,000 E. coli per milliliter and 10,000 E. coli per milliliter respectively. To achieve the detection limit of 1,000 bacteria per milliliter previously established, a method of concentrating microorganisms using a sartorius membrane filter system is investigated. Catalase in 50% ethanol is found to be a stable luminol standard and can be used up to 24 hours with only a 10% loss of activity. The luminol reagent is also stable over a 24 hour period. A method of preparing relatively inexpensive luciferase from desiccated firefly tails is developed.

Thomas, R. R.↗

Sample size estimation for case‐crossover studies

Case‐crossover study designs are observational studies used to assess postmarket safety of medical products (eg, vaccines or drugs). As a case‐crossover study is self‐controlled, its advantages include better control for confounding because the design controls for any time‐invariant measured and unmeasured confounding and potentially greater feasibility as only data from those experiencing an event (or cases) are required. However, self‐matching also introduces correlation between case and control periods within a subject or matched unit. To estimate sample size in a case‐crossover study, investigators currently use Dupont's formula ( Biometrics 1988; 43 :1157‐1168), which was originally developed for a matched case‐control study. This formula is relevant as it takes into account correlation in exposure between controls and cases, which are expected to be high in self‐controlled studies. However, in our study, we show that Dupont's formula and other currently used methods to determine sample size for case‐crossover studies may be inadequate. Specifically, these formulas tend to underestimate the true required sample size, determined through simulations, for a range of values in the parameter space. We present mathematical derivations to explain where some currently used methods fail and propose two new sample size estimation methods that provide a more accurate estimate of the true required sample size.

Dharmarajan, Sai↗

Ensemble Grouping Strategies for Embedded Stochastic Collocation Methods Applied to Anisotropic Diffusion Problems

Previous work has demonstrated that propagating groups of samples, called ensembles, together through forward simulations can dramatically reduce the aggregate cost of sampling-based uncertainty propagation methods [E. Phipps, M. D'Elia, H. C. Edwards, M. Hoemmen, J. Hu, and S. Rajamanickam, SIAM J. Sci. Comput., 39 (2017), pp. C162--C193]. However, critical to the success of this approach when applied to challenging problems of scientific interest is the grouping of samples into ensembles to minimize the total computational work. For example, the total number of linear solver iterations for ensemble systems may be strongly influenced by which samples form the ensemble when applying iterative linear solvers to parameterized and stochastic linear systems. In this paper we explore sample grouping strategies for local adaptive stochastic collocation methods applied to PDEs with uncertain input data, in particular canonical anisotropic diffusion problems where the diffusion coefficient is modeled by truncated Karhunen--Loève expansions. Finally, we demonstrate that a measure of the total anisotropy of the diffusion coefficient is a good surrogate for the number of linear solver iterations for each sample and therefore provides a simple and effective metric for grouping samples.

97 MATHEMATICS AND COMPUTING↗

High Fidelity Forward Model Development for Nuclear Reactor Spent Fuel Technical Nuclear Forensics

The fidelity of the forward model within a spent fuel forensic analysis system was improved by using two unique methodologies. The first consisted of developing a system to create accurate one-group neutron cross-section libraries for any user specified reactor system. In such, a detailed model is developed using the depletion code MONTEBURNS. During MONTEBURNS execution, cross-section libraries are generated at every user specified burnup step in time. These libraries could be developed for many reactor systems, then housed in a database and used for analyzing unknown fuel samples. The forensic analysis system for spent fuel resulted in higher accuracy at predicting the initial uranium isotopic compositions and burnup from spent fuel samples. Using this method, the error in results was reduced from the order of 1-6% down to less than 1% when recovering a fuel sample's burnup and initial uranium isotopic composition. The second method consisted of implementing 2D/3D reactor depletion codes as the forward model within the system's framework. This method would allow the usage of potentially recoverable geometric information from an unknown sample. No predetermined cross-section library is required for the system using this method, therefore potentially reducing model error associated with the neutron flux spectrum. The accuracy of the recovered initial uranium isotopic compositions and burnup from spent fuel samples was also improved using this method, even more so than the first. For MTR reactors, the error using this method was significantly reduced and was driven to below 0.5%. However, additional research may be required to determine the ideal fission yield and recoverable energy per fission for cases where significant amounts of 239 PU are bred and burned throughout the life of the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of tritium with plastic scintillator surface improvement with plasma treatment

Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic which contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning–driven rare-event sampling reveals an Ala7/d-Ala8 conformational hinge governing amphiphilic switching in cyclosporine A

Passive membrane permeability of N-methylated macrocyclic peptides remains poorly understood because high-energy conformational intermediates are rarely sampled by conventional methods. Using the deep learning–driven rare-event sampling framework ES-CRUMPLE, we show that cyclosporine A accesses transient amphiphilic states via a localized conformational hinge at Ala7/d-Ala8, revealing a kinetic design handle that is invisible to population-based analyses.

Lindberg, Edward T [University of Tennessee, Knoxv↗

Band gap engineering of N-alloyed Ga{sub 2}O{sub 3} thin films

The authors report the tuning of band gap of GaON ternary alloy in a wide range of 2.75 eV. The samples were prepared by a two-step nitridation method. First, the samples were deposited on 2-inch fused silica substrates by megnetron sputtering with NH{sub 3} and Ar gas for 60 minutes. Then they were annealed in NH{sub 3} ambience at different temperatures. The optical band gap energies are calculated from transmittance measurements. With the increase of nitridation temperature, the band gap gradually decreases from 4.8 eV to 2.05 eV. X-ray diffraction results indicate that as-deposited amorphous samples can crystallize into monoclinic and hexagonal structures after they were annealed in oxygen or ammonia ambience, respectively. The narrowing of the band gap is attributed to the enhanced repulsion of N2p -Ga3d orbits and formation of hexagonal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A collection of flow visualization techniques used in the Aerodynamic Research Branch

Theoretical and experimental research on unsteady aerodynamic flows is discussed. Complex flow fields that involve separations, vortex interactions, and transonic flow effects were investigated. Flow visualization techniques are used to obtain a global picture of the flow phenomena before detailed quantitative studies are undertaken. A wide variety of methods are used to visualize fluid flow and a sampling of these methods is presented. It is emphasized that the visualization technique is a thorough quantitative analysis and subsequent physical understanding of these flow fields.

Source record↗

Conservative Estimation of Tail Probabilities from Limited Sample Data

Several sparse-sample uncertainty quantification (UQ) methods are compared for conservative but not overly conservative estimation of small tail probabilities involving responses that lay beyond specified thresholds in the tails of probability distributions. Sixteen very differently shaped distributions (or probability density functions, PDFs) and tail probability magnitudes ranging from 10 -5 to 10 -1 are considered in order for the study to be relevant to a wide range of risk analysis and quantification of margins and uncertainty (QMU) problems. The emphasis of the study is on limited data regimes ranging from N = 2 to 20 samples, reflective of most experimental and some expensive computational situations. Relatively simple sparse-sample UQ methods tested for this regime involve statistical tolerance interval "Equivalent Normal and related "Ensemble of Normals" and "Superdistribution (SD) approaches. (The independently derived SD is effectively equivalent to the Bayesian posterior predictive distribution given the assumptions of the derivation.) The performance of the methods was generally improved for N ≥ 5 samples with a generalized Jackknife resampling technique, which determines a tail probability estimate by averaging estimates from smaller sub-samples. Several quantitative metrics for method conservatism and accuracy of tail probability estimation are used to assess and rank the methods' performance over many random trials for each test PDF and probability magnitude. A variant of Bootstrap resampling was also tried, but did not significantly improve tail probability estimates in most cases. Detailed results are presented from over 100-million tests over the above factors that provide useful granular information on which methods or combination of methods perform best in various areas of the factor space.

97 MATHEMATICS AND COMPUTING↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Communication: Estimating the initial biasing potential for λ-local-elevation umbrella-sampling (λ-LEUS) simulations via slow growth

In a recent article [Bieler et al., J. Chem. Theory Comput. 10, 3006–3022 (2014)], we introduced a combination of the λ-dynamics (λD) approach for calculating alchemical free-energy differences and of the local-elevation umbrella-sampling (LEUS) memory-based biasing method to enhance the sampling along the alchemical coordinate. The combined scheme, referred to as λ-LEUS, was applied to the perturbation of hydroquinone to benzene in water as a test system, and found to represent an improvement over thermodynamic integration (TI) in terms of sampling efficiency at equivalent accuracy. However, the preoptimization of the biasing potential required in the λ-LEUS method requires “filling up” all the basins in the potential of mean force. This introduces a non-productive pre-sampling time that is system-dependent, and generally exceeds the corresponding equilibration time in a TI calculation. In this letter, a remedy is proposed to this problem, termed the slow growth memory guessing (SGMG) approach. Instead of initializing the biasing potential to zero at the start of the preoptimization, an approximate potential of mean force is estimated from a short slow growth calculation, and its negative used to construct the initial memory. Considering the same test system as in the preceding article, it is shown that of the application of SGMG in λ-LEUS permits to reduce the preoptimization time by about a factor of four.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for utilizing properties of the sinc(x) function for phase retrieval on nyquist-under-sampled data

Disclosed herein are systems, methods, and non-transitory computer-readable storage media for simulating propagation of an electromagnetic field, performing phase retrieval, or sampling a band-limited function. A system practicing the method generates transformed data using a discrete Fourier transform which samples a band-limited function f(x) without interpolating or modifying received data associated with the function f(x), wherein an interval between repeated copies in a periodic extension of the function f(x) obtained from the discrete Fourier transform is associated with a sampling ratio Q, defined as a ratio of a sampling frequency to a band-limited frequency, and wherein Q is assigned a value between 1 and 2 such that substantially no aliasing occurs in the transformed data, and retrieves a phase in the received data based on the transformed data, wherein the phase is used as feedback to an optical system.

Dean, Bruce H.↗