Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Reference dosimetry for helical tomotherapy: Practical implementation and a multicenter validation

Purpose: The aim of this study was to implement a protocol for reference dosimetry in tomotherapy and to validate the beam output measurements with an independent dosimetry system. Methods: Beam output was measured at the reference depth of 10 cm in water for the following three cases: (1) a 5 x 10 cm{sup 2} static machine specific reference field (MSR), (2) a rotational 5 x 10 cm{sup 2} field without modulation and no tabletop in the beam, (3) a plan class specific reference (PCSR) field defined as a rotational homogeneous dose delivery to a cylindrical shaped target volume: plan with modulation and table-top movement. The formalism for reference dosimetry of small and nonstandard fields [Med.Phys.35: 5179-5186, 2008] and QA recommendations [Med.Phys.37: 4817-4853, 2010] were adopted in the dose measurement protocol. All ionization chamber measurements were verified independently using alanine/EPR dosimetry. As a pilot study, the beam output was measured on tomotherapy Hi-art systems at three other centers and directly compared to the centers specifications and to alanine dosimetry. Results: For the four centers, the mean static output at a depth of 10 cm in water and SAD = 85 cm, measured with an A1SL chamber following the TG-148 report was 6.238 Gy/min {+-} 0.058 (1 SD); the rotational output was 6.255 Gy/min {+-} 0.069 (1 SD). The dose stated by the center was found in good agreement with the measurements of the visiting team: D{sub center}/D{sub visit} = 1.000 {+-} 0.003 (1 SD). The A1SL chamber measurements were all in good agreement with Alanine/EPR dosimetry. Going from the static reference field to the rotational/non modulated field the dose rate remains constant within 0.2% except for one center where a deviation of 1.3% was detected. Conclusions: Following the TG-148 report, beam output measurements in water at the reference depth using a local protocol, as developed at different centers, was verified. The measurements were found in good agreement with alanine/EPR dosimetry. The presented methodology may provide a good concept for reference dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Vagal tone as an index of mental state

The utility of monitoring oscillations in the heart rate pattern as a window to the brain is discussed as an index of general central nervous system status. Quantification of the amplitude of respiratory sinus arrhythmia provides an accurate index of cardiac vagal tone. A number of studies have demonstrated the validity of this measure; the relationship between flight performance and vagal tone has also been studied. In general, the vagal tone index appears to monitor global states of the central nervous system and may be useful in screening the general state of pilots.

Porges, Stephen W.↗

The experiment filtering tool in the MACSENS workbench - 14341

The MACSENS (outils Moret d'Aide a la Caracterisation et aux etudes de SENSibilite) workbench is dedicated to the advanced validation work for criticality studies. The aim of this kind of tool is to determine the experiments from a validation database being the 'closest' to an application case and, from there, to evaluate a calculation bias with a related uncertainty. To achieve this goal, the MACSENS workbench relies on different kind of information stored in various databases depending on the origin of the data. Two main kinds of data can be identified. The first one concerns the data used to describe the experiments of the validation database (e.g. the inputs needed to perform a calculation). These values characterize the chemical and geometrical models. They can be considered as constant, as they do not vary once evaluated, and some of them can be from a non-numerical nature (reflector material for example...). The second kind of data gathers the results obtained with the use of a simulation code, such as reaction rates, fluxes and leakages, sensitivities, k{sub eff}, etc. These values depend on the version of the code and are purely numerical. In the early 2000's, regarding the increasing number of experiments evaluated in the ICSBEP handbook, the OECD/NEA (Organization for Economic Co-operation and Development/Nuclear Energy Agency), under the ICSBEP (International Criticality Safety Benchmark Evaluation Project) working group direction, decided to store such information in a database and to provide a software, called DICE (Database for the International Criticality safety benchmark Evaluation project), allowing users to search easily criticality experiments of interest. Up to now, more than 4400 critical or subcritical configurations have been compiled by ICSBEP, described and stored in the DICE database. Over time, a validation work has been done on the data, with the participation of IRSN, and a quality assurance policy has been defined. For these reasons, the DICE database is highly reliable. These features were fundamental for the MACSENS developers, who were looking for a database containing descriptive data of the experiments included in the MORET code validation database. The paper describes the solution chosen by IRSN to take advantage of the DICE database content and to overcome the DICE limits. It also explains the quality assurance policy applied to guaranty the reliability of the stored data. It will also discuss the use of the experiment-filtering module of the MACSENS workbench to select a set of experiments and to examine numerical parameter trends for an application case. (authors)

42 ENGINEERING↗

CBSIT 2009: Airborne Validation of Envisat Radar Altimetry and In Situ Ice Camp Measurements Over Arctic Sea Ice

The past few years have seen the emergence of satellite altimetry as valuable tool for taking quantitative sea ice monitoring beyond the traditional surface extent measurements and into estimates of sea ice thickness and volume, parameters that arc fundamental to improved understanding of polar dynamics and climate modeling. Several studies have now demonstrated the use of both microwave (ERS, Envisat/RA-2) and laser (ICESat/GLAS) satellite altimeters for determining sea ice thickness. The complexity of polar environments, however, continues to make sea ice thickness determination a complicated remote sensing task and validation studies remain essential for successful monitoring of sea ice hy satellites. One such validation effort, the Arctic Aircraft Altimeter (AAA) campaign of2006. included underflights of Envisat and ICESat north of the Canadian Archipelago using NASA's P-3 aircraft. This campaign compared Envisat and ICESat sea ice elevation measurements with high-resolution airborne elevation measurements, revealing the impact of refrozen leads on radar altimetry and ice drift on laser altimetry. Continuing this research and validation effort, the Canada Basin Sea Ice Thickness (CBSIT) experiment was completed in April 2009. CBSIT was conducted by NOAA. and NASA as part of NASA's Operation Ice Bridge, a gap-filling mission intended to supplement sea and land ice monitoring until the launch of NASA's ICESat-2 mission. CBIST was flown on the NASA P-3, which was equipped with a scanning laser altimeter, a Ku-band snow radar, and un updated nadir looking photo-imaging system. The CB5IT campaign consisted of two flights: an under flight of Envisat along a 1000 km track similar to that flown in 2006, and a flight through the Nares Strait up to the Lincoln Sea that included an overflight of the Danish GreenArc Ice Camp off the coast of northern Greenland. We present an examination of data collected during this campaign, comparing airborne laser altimeter measurements with (1) Envisat RA-2 returns retracked optimally for sea ice and (2) in situ measurements of sea ice thickness and snow depth gathered from ice camp surveys. Particular attention is given to lead identification and classification using the continuous photo-imaging system along the Envisat underflight as well as the performance of the snow radar over the ice camp survey lines.

Connor, Laurence↗

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing and Validating Measurement Scales During Pandemic Conditions: A Case Study with the Scale for Habitat Usability

At NASA, habitat evaluations often employ subjective measures. Some measures are frequently used, well established tools, whereas others are homegrown measures tailored to specific projects. The variety of measures used makes evaluation comparisons across projects difficult. Additionally, some of these measures are burdensome, may be too specialized, or may require an expert to use and interpret, limiting their utility. Taken together, these drawbacks suggest the need for a new measurement tool. To that purpose, a team at NASA worked on developing a new scale for measuring habitat usability, the Scale for Habitat Usability (SHU). The SHU is intended to be a quick, multi-faceted measure for evaluating habitat usability across the development lifecycle. However, like many research projects, the development of the SHU faced setbacks due to the COVID-19 pandemic. Pandemic prevention protocols precluded in-person data collection, forcing the team to take some non-traditional approaches to scale development. This paper reports the steps the team took to complete the project.

Ian Robertson↗

A cross-study analysis of drug response prediction in cancer cell lines

Abstract To enable personalized cancer treatment, machine learning models have been developed to predict drug response as a function of tumor and drug features. However, most algorithm development efforts have relied on cross-validation within a single study to assess model accuracy. While an essential first step, cross-validation within a biological data set typically provides an overly optimistic estimate of the prediction performance on independent test sets. To provide a more rigorous assessment of model generalizability between different studies, we use machine learning to analyze five publicly available cell line-based data sets: National Cancer Institute 60, ancer Therapeutics Response Portal (CTRP), Genomics of Drug Sensitivity in Cancer, Cancer Cell Line Encyclopedia and Genentech Cell Line Screening Initiative (gCSI). Based on observed experimental variability across studies, we explore estimates of prediction upper bounds. We report performance results of a variety of machine learning models, with a multitasking deep neural network achieving the best cross-study generalizability. By multiple measures, models trained on CTRP yield the most accurate predictions on the remaining testing data, and gCSI is the most predictable among the cell line data sets included in this study. With these experiments and further simulations on partial data, two lessons emerge: (1) differences in viability assays can limit model generalizability across studies and (2) drug diversity, more than tumor diversity, is crucial for raising model generalizability in preclinical screening.

59 BASIC BIOLOGICAL SCIENCES↗

HSPB1 Gene Polymorphisms Predict Risk of Mortality for US Patients After Radio(chemo)therapy for Non-Small Cell Lung Cancer

Purpose: We investigated potential associations between single-nucleotide polymorphisms (SNPs) in the heat shock protein beta-1 (HSPB1) gene and overall survival in US patients with non-small cell lung cancer (NSCLC). Methods and Materials: Using available genomic DNA samples from 224 patients with NSCLC treated with definitive radio(chemo)therapy, we genotyped 2 SNPs of HSPB1 (NCBI SNP nos. rs2868370 and rs2868371). We used both Kaplan-Meier cumulative probability and Cox proportional hazards analyses to evaluate the effect of HSPB1 genotypes on survival. Results: Our cohort consisted of 117 men and 107 women, mostly white (79.5%), with a median age of 70 years. The median radiation dose was 66 Gy (range, 63-87.5 Gy), and 183 patients (82%) received concurrent platinum-based chemotherapy. The most common genotype of the rs2868371 SNP was CC (61%). Univariate and multivariate analyses showed that this genotype was associated with poorer survival than CG and GG genotypes (univariate hazard ratio [HR] = 1.39, 95% confidence interval [CI], 1.02-1.90; P=.037; multivariate HR = 1.39; 95% CI, 1.01-1.92; P=.045). Conclusions: Our results showed that the CC genotype of HSPB1 rs2868371 was associated with poorer overall survival in patients with NSCLC after radio(chemo)therapy, findings that contradict those of a previous study of Chinese patients. Validation of our findings with larger numbers of similar patients is needed, as are mechanical and clinical studies to determine the mechanism underlying these associations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency-response identification of XV-15 tilt-rotor aircraft dynamics

The timely design and development of the next generation of tilt-rotor aircraft (JVX) depend heavily on the in-depth understanding of existing XV-15 dynamics and the availability of fully validated simulation models. Previous studies have considered aircraft and simulation trim characteristics, but analyses of basic flight vehicle dynamics were limited to qualitative pilot evaluation. The present study has the following objectives: documentation and evaluation of XV-15 bare-airframe dynamics; comparison of aircraft and simulation responses; and development of a validated transfer-function description of the XV-15 needed for future studies. A nonparametric frequency-response approach is used which does not depend on assumed model order or structure. Transfer-function representations are subsequently derived which fit the frequency responses in the bandwidth of greatest concern for piloted handling-qualities and control-system applications.

Tischler, Mark B.↗

Decontaminant delivery and application methods to enhance decontamination process and efficacy

The objective for the experimental effort was to provide validation for the electrostatic aerosol transport models for particle size and deposition rate and to determine the feasibility of an electrostatic spray process in delivering non-corrosive decontaminants to complex interior spaces, such as an aircraft. The project utilized ITW (Illinois Tool Works) rotary atomizing induction charged nozzle to disperse small, charged droplets of liquid decontaminants uniformly through a contaminated space. Particle size and deposition studies were conducted prior to the feasibility study where the ITW nozzle was optimized and characterized for two decontaminants: EasyDeconTM200 (DF-200) and Steriplex® SD. In addition to the validation studies, two feasibility studies were conducted with anthrax simulant (B. atrophaeus) and sarin simulant (diphenol chlorophosphate, DPCP). Running parameters for the two studies varied according to the starting contaminant challenges (1.0 x 108 CFU/m 2 for B. atrophaeus and 1.0 g/m 2 for DPCP), the amount of decontaminant deposition, and, finally, decontaminant to agent contact time. Results for the DPCP study confirm that our spray method met and exceeded the threshold criteria of <10 mg/m 2 , postdecontamination, for Teflon and aluminum coupons. Results from this study also showed that polycarbonate and rubber coupons can be reduced by <98% and <92%, respectively. Results for the B. atrophaeus study presented a slightly different challenge due to coupon size, however, increasing the size of the coupon confirmed that it is possible for our spray method to meet the threshold criteria of <100 CFU/m 2 . In addition, a computational model was developed in ANSYS Fluent to solve for the air flow, space charge, electric field, and droplet motion involved in electrostatic aerosol transport. Comparison of the model to experiments resulted in good agreement in deposition pattern and total mass deposited on surfaces. Finally, as a consequence of this project, the methodology used for decontamination could be used to improve future contamination scenarios by eliminating or reducing contaminant hazards, thereby allowing equipment and/or facilities, previously unusable, to be reclaimed rather than discarded, resulting in an overall cost savings to the customer.

36 MATERIALS SCIENCE↗

Computational study of critical mass curves for various ratios of {sup 238}Pu to {sup 239}Pu

A MCNP study for a water-reflected sphere of plutonium metal water pseudo-solution was performed for a various ratios of {sup 238}Pu to {sup 239}Pu to develop minimum critical mass curves. The {sup 238}Pu atom percent (at. %) was varied from 35 to 100 percent. It was demonstrated that at {sup 238}Pu ratios of ≥ 65 at. % the high absorption cross section of {sup 238}Pu in the thermal energy region dominates the system reactivity for water moderated systems resulting in a minimum critical mass in the metal rather than solution regime. However, due to the lack of available benchmark experiments to validated use of the {sup 238}Pu cross-section data for quantities above gram-level, the models fell outside the area of applicability (AOA) of the Los Alamos National Laboratory's (LANL) Nuclear Criticality Safety Division's (NCSD) MCNP validation report. An additional of margin of subcriticality (MOS) is needed for {sup 238}Pu systems. This additional MOS will be dependent on the amount and significance of the {sup 238}Pu, which varies in the MCNP study. Whisper is a computational software package designed to assist with validation studies for MCNP. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application model. Therefore, Whisper 1.0.0 was used on the curve minima in the solution regime for the 65 at. % {sup 238}Pu curve to estimate an appropriate additional margin of subcriticality and create a subcritical curve based on the suggested upper subcritical limits (USL)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of the GFS model for gyrokinetic stability of NSTX pedestal data

This study presents a large database validation of the gyro fluid system (GFS) model for linear gyrokinetic stability for high-mode (H-mode) edge transport barrier conditions in the national spherical torus experiment (NSTX) tokamak. The database of linear stability calculations with the CGYRO gyrokinetic code was produced using plasma profile measurements from NSTX discharges to identify kinetic ballooning modes (KBM), trapped electron modes (TEM), and micro-tearing modes (MTM) that limit the pressure profile gradient in the H-mode barrier. A novel Bayesian optimization approach determines optimal resolution parameters for GFS specifically for spherical tokamak pedestal conditions. Our results demonstrate that GFS, with optimized resolution, can achieve accurate linear stability analysis in NSTX pedestal conditions for reduced resolution compared to CGYRO. GFS can accurately find the KBM, TEM, and MTM instability branches. Parametric analysis reveals that GFS accuracy in this extreme pedestal parameter range is degraded for low magnetic shear and near the separatrix conditions. These findings establish GFS as a fast linear eigenmode solver for spherical tokamak pedestal gyrokinetic stability and demonstrate a systematic methodology for determining the optimum resolution settings.

Yang, Minglei [Oak Ridge National Laboratory (ORNL↗

An experimental study of characteristic combustion-driven flows for CFD validation

The application of laser-based diagnostic techniques has become commonplace to a wide variety of combustion problems. New insights into combustion phenomena at a level previously unattainable has been made possible by non-intrusive measurements of velocity, temperature, and species. However, due to the adverse conditions which exist inside rocket engines, relatively few studies have addressed these combustion environments. The high pressure, high speed, combusting environment in a rocket engine prohibits the application of several measurement techniques. However, in the rocket community, there is a critical need for rocket flow field data to validate computational fluid dynamic (CFD) codes. Currently at Penn State, there is an effort to obtain flowfield measurements inside a rocket engine. Velocity measurements have been made inside the combustion chamber of a uni-element (shear coaxial injector) optically accessible rocket chamber at several axial locations downstream of the injector. These measurements, combined with future measurements, will provide benchmark data for CFD code validation.

Pal, S.↗