Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Central Diffraction in ALICE

The ALICE experiment consists of a central barrel in the pseudorapidity range -0.9<{eta}<0.9 and of additional detectors covering about 3 units of pseudorapidity on either side of the central barrel. Such a geometry allows the tagging of single and double gap events. The status of the analysis of such diffractive events in proton-proton collisions at {radical}(s) = 7 TeV is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction with CMS

The observation of diffraction at LHC with the CMS detector at {radical}(s) = 900 and 2360 GeV is presented, along with a comparison of the data with the predictions of the PYTHIA and PHOJET generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerator Science and Technology Breakthroughs, Achievements and Lessons from the Tevatron

For almost a quarter of a century, the Tevatron proton-antiproton collider was the centerpiece of the world's high energy physics program - beginning operation in December of 1985 until it was overtaken by LHC in 2011. The aim of this unique scientific instrument was to explore the elementary particle physics reactions with center of mass collision energies of up to 1.96 TeV. The initial design luminosity of the Tevatron was 1030cm-2s-1, however as a result of two decades of upgrades, the accelerator has been able to deliver 430 times higher luminosities to each of two high luminosity experiments, CDF and D0. The Tevatron will be shut off September 30, 2011. The collider was arguably one of the most complex research instruments ever to reach the operation stage and is widely recognized for many technological breakthroughs and numerous physics discoveries. In this John Adams lecture, I briefly present the history of the Tevatron, major advances in accelerator physics, and technology implemented during the long quest for better and better performance. Lessons learned from our experience are also discussed.

43 PARTICLE ACCELERATORS↗

Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction

In this paper we look at the properties of the Spallation Neutron Source (SNS) Differential Beam Current Monitor (DCM) data and various methods of data transformation to improve pre-emptive detection of machine trips. In this study, the foundation of the approach is the analysis of new underlying data and understanding various properties with the goal of faster classification, higher precision and higher recall with the aim to reduce false positives as low as required. The result of the research presented in this paper are a binary classifier capable of predicting accelerator failures with millisecond classification time, 96% precision, 58% true positive and 0% false positive rate and optimization techniques enabling real-time implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d{sub max}), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R{sub 50} in terms of C{sub 50} (50% CE depth) revealed a strong linear dependence (R{sup 2} > 0.9999). The SCR was fit with a Burns-type equation (R{sup 2} = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Horizontal Seismic Hazard of Shahrekord, Iran

This paper presents probabilistic horizontal seismic hazard assessment of Shahrekord, Iran. It displays the probabilistic estimate of Peak Ground Horizontal Acceleration (PGHA) for the return period of 75, 225, 475 and 2475 years. The output of the probabilistic seismic hazard analysis is based on peak ground acceleration (PGA), which is the most common criterion in designing of buildings. A catalogue of seismic events that includes both historical and instrumental events was developed and covers the period from 840 to 2007. The seismic sources that affect the hazard in Shahrekord were identified within the radius of 150 km and the recurrence relationships of these sources were generated. Finally four maps have been prepared to indicate the earthquake hazard of Shahrekord in the form of iso-acceleration contour lines for different hazard levels by using SEISRISK III software.

58 GEOSCIENCES↗

Future Plans of Telescope Array

The Telescope Array (TA) experiment is the only ultra high energy cosmic ray observatory in the northern hemisphere. In addition, it will be the world's first air shower detector to be directly calibrated by an on-site accelerator beam. For wider and deeper understanding of cosmic rays by via high precision measurements, we have undertaken the study of extension plans for TA. One extension plan will extend the sensitive energy range of TA down to 10{sup 17} eV. A second plan would extend of the aperture area of the SD array. These plans are described in this note.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of induced seismicity and ground vibrations associated with geologic CO 2 storage, and assessing their effects on surface structures and human perception

In this paper, we present model simulations of ground motions caused by CO 2 -injection-induced fault reactivation and analyze the results in terms of the potential for damage to ground surface structures and nuisance to the local human population. It is an integrated analysis from cause to consequence, including the whole chain of processes starting from earthquake inception in the subsurface, wave propagation toward the ground surface, and assessment of the consequences of ground vibration. For a small magnitude (M w =3) event at a hypocenter depth of about 1000m, we first used the simulated ground-motion wave train in an inverse analysis to estimate source parameters (moment magnitude, rupture dimensions and stress drop), achieving good agreement and thereby verifying the modeling of the chain of processes from earthquake inception to ground vibration. We then analyzed the ground vibration results in terms of peak ground acceleration (PGA), peak ground velocity (PGV) and frequency content, with comparison to U.S. Geological Survey's instrumental intensity scales for earthquakes and the U.S. Bureau of Mines' vibration criteria for cosmetic damage to buildings, as well as human-perception vibration limits. Our results confirm the appropriateness of using PGV (rather than PGA) and frequency for the evaluation of potential ground-vibration effects on structures and humans from shallow injection-induced seismic events. For the considered synthetic M w =3 event, our analysis showed that the short duration, high frequency ground motion may not cause any significant damage to surface structures, but would certainly be felt by the local population.

54 ENVIRONMENTAL SCIENCES↗

Study of F- Production in BaBar RPCs

The BaBar detector has operated over 200 2nd generation Resistive Plate Chambers (RPCs) in the forward endcap since 2002. Many chambers have increased noise rates and high voltage currents. These aging symptoms are correlated with the integrated RPC current as expected, but also depend on the rate and direction of the gas flow, indicating that pollutants produced in the gas can accelerate aging of downstream RPC surfaces. HF produced by decomposition of the Freon 134a component of the BaBar RPC gas in electric discharges has been proposed as the main pollutant. This paper presents measurements of HF production and absorption rates in BaBar RPCs. Since many of the highest rate chambers in the forward endcap were converted to avalanche mode operation, a comparison of HF production in streamer and avalanche mode RPCs is made. Correlations between the HF production rate and other chamber operating conditions were also explored.

43 PARTICLE ACCELERATORS↗

Bi-resonant klynac

Here in this work, we present the first analysis of a new device called the bi-resonant klynac, which is a combined klystron and linac. In a bi-resonant klynac, all RF cells, except for the cell that acts as the input for the klystron section, belong to a single resonant circuit. This resonant coupling configuration leads to increased operational stability and can tolerate significant temperature variations. In this paper, a basic analysis of this device is presented, including discussions of how it operates and of the advantages of resonantly coupling the RF generation directly to the linac. We additionally describe the approach used to numerically model the klynac and we include detailed simulations of a 50-kV, 10-A klynac that produces a 1-MeV, 0.1-A output beam. In conclusion, this type of device may be especially useful for situations where an electron beam is needed at low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of ultrahigh-brightness pre-bunched beams from a plasma cathode for X-ray free-electron lasers

The longitudinal coherence of X-ray free-electron lasers (XFELs) in the self-amplified spontaneous emission regime could be substantially improved if the high brightness electron beam could be pre-bunched on the radiated wavelength-scale. Here, we show that it is indeed possible to realize such current modulated electron beam at angstrom scale by exciting a nonlinear wake across a periodically modulated plasma-density downramp/plasma cathode. The density modulation turns on and off the injection of electrons in the wake while downramp provides a unique longitudinal mapping between the electrons’ initial injection positions and their final trapped positions inside the wake. The combined use of a downramp and periodic modulation of micrometers is shown to be able to produces a train of high peak current (17 kA) electron bunches with a modulation wavelength of 10’s of angstroms - orders of magnitude shorter than the plasma density modulation. The peak brightness of the nano-bunched beam can be $\textit{O}$(10 21 A/m 2 /rad 2 ) orders of magnitude higher than current XFEL beams. Such prebunched, high brightness electron beams hold the promise for compact and lower cost XEFLs that can produce nanometer radiation with hundreds of GW power in a 10s of centimeter long undulator.

47 OTHER INSTRUMENTATION↗

Long lifetime of bialkali photocathodes operating in high gradient superconducting radio frequency gun

Abstract High brightness, high charge electron beams are critical for a number of advanced accelerator applications. The initial emittance of the electron beam, which is determined by the mean transverse energy (MTE) and laser spot size, is one of the most important parameters determining the beam quality. The bialkali photocathodes illuminated by a visible laser have the advantages of high quantum efficiency (QE) and low MTE. Furthermore, Superconducting Radio Frequency (SRF) guns can operate in the continuous wave (CW) mode at high accelerating gradients, e.g. with significant reduction of the laser spot size at the photocathode. Combining the bialkali photocathode with the SRF gun enables generation of high charge, high brightness, and possibly high average current electron beams. However, integrating the high QE semiconductor photocathode into the SRF guns has been challenging. In this article, we report on the development of bialkali photocathodes for successful operation in the SRF gun with months-long lifetime while delivering CW beams with nano-coulomb charge per bunch. This achievement opens a new era for high charge, high brightness CW electron beams.

43 PARTICLE ACCELERATORS↗

Diamond Detectors for Compton Polarimetry

Parity-violating electron scattering experiments aim to test the standard model of particle physics through precise low-energy determinations of the weak mixing angle. These experiments require determination of the polarization of the incident electron beam to the 1% level or better. An example of this type of experiment is the Q-weak experiment, which will be conducted in Hall C at Jefferson Lab in 2010 and beyond. We are constructing a Compton polarimeter in Hall C to provide continuous monitoring of the polarization with the goal of 1% absolute polarization determination. In our Compton polarimeter, circularly polarized laser light will impinge upon the electron beam. Electrons scattered by the Compton process will be momentum-analyzed in a dipole magnet downstream of the interaction point. A diamond strip tracker will be placed further downstream of the dipole to sense the Compton-scattered electrons and determine their momenta. The design of the polarimeter, focusing on electron detection, and our progress in prototyping and constructing the diamond strip tracker, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ALICE Electromagnetic Calorimeter

ALICE (A Large Ion Collider Experiment) is the only LHC experiment at CERN fully dedicated to the study of the quark and gluon plasma. Driven by the RHIC results on jet quenching, the ALICE collaboration has proposed to extend the capabilities of the ALICE detector for the study of high momentum photons and jets by adding a large acceptance calorimeter. This EMCal (ElectroMagnetic Calorimeter) is designed to provide an unbiased fast high-p{sub T} trigger and to measure the neutral energy of jets and photons up to 200 GeV. Four over ten supermodules of the calorimeter have been installed and commissioned at CERN in 2009 which represents 40% of the full acceptance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Few-Nucleon Systems with the CEBAF Large Acceptance Spectrometer

The study of few-nucleon systems at intermediate energies is an important aspect of the nuclear-physics program carried out by the CLAS Collaboration at Jefferson Laboratory. Our investigations aim at understanding the nuclear dynamics at short distances, the transition from hadronic to partonic description of nuclei, and how nuclei can be described in the framework of Quantum Chromodynamics. Our data on photodisintegration of {sup 3}He and {sup 4}He at beam energies from 0.3 GeV to 1.5 GeV strongly favor theoretical calculations that include three-body mechanisms and indicate significant contributions of these mechanisms at large momentum transfer, especially in the range of photon energies from 0.6 GeV to 0.8 GeV. Our investigations of exclusive and inclusive electron scattering off nuclear targets have yielded the determination of the ratio of pp to pn correlated pairs in {sup 3}He and of the probabilities of short-range correlations in nuclei. We have studied the transition from hadronic to partonic dynamics in nuclear processes by searching for the onset of scaling of the invariant cross sections of photoinduced reactions on few-nucleon systems. Our data are consistent with scaling at momentum transfer as low as 1 (GeV/c){sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent photoproduction of {pi}{sup +} from {sup 3}He with CLAS at Jefferson Lab

We have measured the differential cross section for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction. This reaction was studied using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.5 to 1.55 GeV were incident on a cryogenic liquid {sup 3}He target. The differential cross sections for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gain analysis of higher-order-mode amplification in a dielectric-implanted multi-beam traveling wave structure

A multi-beam traveling wave amplifier designed with an overmoded staggered double grating array was examined by small signal analysis combined with simulation. Eigenmode and S-parameter analyses show that the 2 cm long slow wave structure (SWS) has 1–5 dB insertion loss over the passband (TM{sub 31} mode) with ∼28% cold bandwidth. Analytic gain calculation indicates that in the SWS, TM{sub 31}-mode is amplified with 15–20 dB/beam at 64–84 GHz with three elliptical beams of 10 kV and 150 mA/beam, which was compared with particle-in-cell (PIC) simulations. PIC analysis on the analysis of instability with zero-input driving excitations demonstrated that background noises and non-operating lower order modes are noticeably suppressed by implanting equidistant dielectric absorbers; the overmoded structure only allowed the desired 3rd order mode to propagate in the structure. The designed circuit structure can be widely applied to multi-beam devices for high power RF generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic compressive and tensile strengths of spark plasma sintered alumina

Fully dense submicron grain size alumina samples were manufactured from alumina nano-powder using Spark Plasma Sintering and tested in two kinds of VISAR-instrumented planar impact tests. In the first kind, samples were loaded by 1-mm tungsten impactors, accelerated to a velocity of about 1 km/s. These tests were aimed at studying the Hugoniot elastic limit (HEL) of Spark Plasma Sintering (SPS)-processed alumina and the decay, with propagation distance, of the elastic precursor wave. In the tests of the second kind, alumina samples of 3-mm thickness were loaded by 1-mm copper impactors accelerated to 100–1000 m/s. These tests were aimed at studying the dynamic tensile (spall) strength of the alumina specimens. The tensile fracture of the un-alloyed alumina shows a monotonic decline of the spall strength with the amplitude of the loading stress pulse. Analysis of the decay of the elastic precursor wave allowed determining the rate of the irreversible (inelastic) strains in the SPS-processed alumina at the initial stages of the shock-induced inelastic deformation and to clarify the mechanisms responsible for the deformation. The 1-% addition of Cr{sub 2}O{sub 3} decreases the HEL of the SPS-processed alumina by 5-% and its spall strength by 50% but barely affects its static properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗