Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Bed Rest and Orthostatic-Hypotensive Intolerance

Orthostatic tolerance may be defined as the ability of humans to maintain cerebral perfusion and consciousness upon movement from a supine or sitting position to the upright posture; for example, subjects can stand suddenly or be tilted to the head-up body position. Similar but not identical physiological responses can be induced by positive G(sub Z) (head to foot) acceleration or exposure to lower body negative pressure (LBNP). The objective is to suddenly shift blood to the lower body to determine how effectively cardiovascular and neural-hormonal compensatory responses react to maintain blood pressure. In the most precise method for measuring tolerance, individuals would be stressed until they faint (syncope). However, the potential consequences and discomforts of such a test usually prohibit such a procedure so that few investigators actually induce syncope. In a more common approach, subjects are exposed to a given level of stress, for example, head-up tilt for 15 min, and any increases in heart rate or decreases in blood pressure are interpreted as indicators of progress toward syncope. Presumably, the greater the perturbation of heart rate and blood pressure, the closer to "tolerance," i.e., point of unconsciousness. Another more appropriate approach is to induce a progressively increasing hypotensive stress until pre-determined physiological responses or pre-syncopal symptoms appear. The physiological criteria may include a sudden drop in systolic blood pressure (greater than 25 mm/min), a sudden drop in heart rate (greater than 15 beats/min), or a systolic blood pressure less than 70 mmHg. The most common pre-syncopal symptoms include lightheadedness, stomach awareness or distress, feelings of warmth, tingly skin, and light to profuse sweating. Usually a combination of physiological responses and symptoms occurs such that, on different days, the tolerance time to the same orthostatic protocol is reproducible for a given individual. The assumption is that by taking subjects to near fainting, one can determine their tolerance. This latter pre-syncopal approach is better for estimating orthostatic or hypotensive tolerance than the former measurement of heart rate and blood pressure responses to a given stress. There is considerable variability in individual responses to orthostasis. For example, some subjects are "heart-rate responders" and have a pronounced cardiovascular response similar to that when performing moderately hard aerobic exercise, whereas others may experience pre-syncopal symptoms with very little increase in heart rate. Some individuals have a slow, gradual fall in blood pressure to orthostasis, and others have little change in blood pressure until a sudden precipitous fall in pressure occurs just prior to fainting. With both tilt and LBNP tests there is a low correlation between heart-rate or blood-pressure responses to a sub-tolerance stress as a measure of pre-syncopal limited orthostatic-hypotensive tolerance.

Schneider, Suzanne M.↗

Flight Data Analysis of HyShot 2

The development of scramjet propulsion for alternative launch and payload delivery capabilities has comprised largely of ground experiments for the last 40 years. With the goal of validating the use of short duration ground test facilities, the University of Queensland, supported by a large international contingency, devised a ballistic re-entry vehicle experiment called HyShot to achieve supersonic combustion in flight above Mach 7.5. It consisted of a double wedge intake and two back-to-back constant area combustors; one supplied with hydrogen fuel at an equivalence ratio of 0.33 and the other un-fueled. Following a first launch failure on October 30th 2001, the University of Queensland conducted a successful second launch on July 30th, 2002. Post-flight data analysis of the second launch confirmed the presence of supersonic combustion during the approximately 3 second test window at altitudes between 35 and 29 km. Reasonable correlation between flight and some pre-flight shock tunnel tests was observed.

Hass, Neal E.↗

Comprehensive Astronaut Immune Assessment Following a Short-Duration Space Flight

Immune system dysregulation has been demonstrated to occur during spaceflight and has the potential to cause serious health risks to crewmembers participating in exploration class missions. As a part of an ongoing NASA flight experiment assessing viral immunity (DSO-500), a generalized immune assessment was performed on 3 crewmembers who participated in the recent STS-114 Space Shuttle mission. The following assays were performed: (1) comprehensive immunophenotype analysis; (2) T cell function/intracellular cytokine profiles; (4) secreted Th1/Th2 cytokine profiles via cytometric bead array. Immunophenotype analysis included a leukocyte differential, lymphocyte subsets, T cell subsets, cytotoxic/effector CD8+ T cells, memory/naive T cell subsets and constitutively activated T cells. Study timepoints were L-180, L-65, L-10, R+0, R+3 and R+14. Detailed data are presented in the poster text. As expected from a limited number of human subjects, data tended to vary with respect to most parameters. Specific post-flight alterations were as follows (subject number in parentheses): Granulocytosis (2/3), reduced NK cells (3/3), elevated CD4/CD8 ratio (3/3), general CD8+ phenotype shift to a less differentiated phenotype (3/3), elevated levels of memory CD4+ T cells (3/3), loss of L-selectin on T cell subsets (3/3), increased levels of activated T cells (2/3), reduced IL-2 producing T cell subsets (3/3), levels of IFNg producing T cells were unchanged. CD8+ T cell expression of the CD69 activation markers following whole blood stimulation with SEA+SEB were dramatically reduced postflight (3/3), whereas other T cell function assessments were largely unchanged. Cytometric bead array assessment of secreted T cell cytokines was performed, following whole blood stimulation with either CD3/CD28 antibodies or PMA+ionomycin for 48 hours. Specific cytokines assessed were IFNg, TNFa, IL-2, IL-4, IL-5, IL-10. Following CD3/CD28 stimulation, all three crewmembers had a mission-associated reduction in the levels of secreted IFNg. One crewmember had a post-flight inversion in the IFNg/IL-10 ratio postflight, which trended back to baseline by R+14. Detailed cytokine data are presented in the poster text. This testing regimen was designed to correlate immunophenotype changes (thought to correspond to specific in-vivo immune responses or pathogenesis), against altered leukocyte function and cytokine profiles. In-flight studies are required to determine if post-flight alterations are reflective of the in-flight condition, or are a response to landing and readaptation.

Crucian, Brian↗

International Space Station Solar Alpha Rotary Joint Failure Analysis: The Materials and Processes Perspective

This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the ISS configurations spanning ISS Stage 12A. The objective of this analysis is to validate and correlate analytical models used to verify the ISS critical interface dynamic loads and improve its fatigue life prediction. On-Orbit dynamic responses were measured during the ISS configurations throughout ISS Stage 12A by the two main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS) and the Structural Dynamic Measurement System (SDMS). These nominal on-orbit events include Russian vehicle docking and undockings. Also, the ISS photogrammetric system recorded the movements of the 2A and 4A solar arrays during a modified ISS maneuver. Modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shapes. Correlation and comparisons between the test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the ISS configurations under consideration.

Dasgupta, Rajib↗

ISS Stage 12A Post-Flight Modal Analysis, Model Validation and Correlation

This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the ISS configurations spanning ISS Stage 12A. The objective of this analysis is to validate and correlate analytical models used to verify the ISS critical interface dynamic loads and improve its fatigue life prediction. On-Orbit dynamic responses were measured during the ISS configurations throughout ISS Stage 12A by the two main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS) and the Structural Dynamic Measurement System (SDMS). These nominal on-orbit events include Russian vehicle docking and undockings. Also, the ISS photogrammetric system recorded the movements of the 2A and 4A solar arrays during a modified ISS maneuver. Modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shapes. Correlation and comparisons between the test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the ISS configurations under consideration.

Fitzpatrick, Kristin↗

Seal Analysis for the Ares-I Upper Stage Fuel Tank Manhole Cover

Techniques for studying the performance of Naflex pressure-assisted seals in the Ares-I Upper Stage liquid hydrogen tank manhole cover seal joint are explored. To assess the feasibility of using the identical seal design for the Upper Stage as was used for the Space Shuttle External Tank manhole covers, a preliminary seal deflection analysis using the ABAQUS commercial finite element software is employed. The ABAQUS analyses are performed using three-dimensional symmetric wedge finite element models. This analysis technique is validated by first modeling a heritage External Tank liquid hydrogen tank manhole cover joint and correlating the results to heritage test data. Once the technique is validated, the Upper Stage configuration is modeled. The Upper Stage analyses are performed at 1.4 times the expected pressure to comply with the Constellation Program factor of safety requirement on joint separation. Results from the analyses performed with the External Tank and Upper Stage models demonstrate the effects of several modeling assumptions on the seal deflection. The analyses for Upper Stage show that the integrity of the seal is successfully maintained.

Phillips, Dawn R.↗

NEXT Ion Thruster Thermal Model

As the NEXT ion thruster progresses towards higher technology readiness, it is necessary to develop the tools that will support its implementation into flight programs. An ion thruster thermal model has been developed for the latest prototype model design to aid in predicting thruster temperatures for various missions. This model is comprised of two parts. The first part predicts the heating from the discharge plasma for various throttling points based on a discharge chamber plasma model. This model shows, as expected, that the internal heating is strongly correlated with the discharge power. Typically, the internal plasma heating increases with beam current and decreases slightly with beam voltage. The second is a model based on a finite difference thermal code used to predict the thruster temperatures. Both parts of the model will be described in this paper. This model has been correlated with a thermal development test on the NEXT Prototype Model 1 thruster with most predicted component temperatures within 5 to 10 C of test temperatures. The model indicates that heating, and hence current collection, is not based purely on the footprint of the magnet rings, but follows a 0.1:1:2:1 ratio for the cathode-to-conical-to-cylindrical-to-front magnet rings. This thermal model has also been used to predict the temperatures during the worst case mission profile that is anticipated for the thruster. The model predicts ample thermal margin for all of its components except the external cable harness under the hottest anticipated mission scenario. The external cable harness will be re-rated or replaced to meet the predicted environment.

VanNoord, Jonathan L.↗

Design and Test Plans for a Non-Nuclear Fission Power System Technology Demonstration Unit

A joint National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) team is developing concepts and technologies for affordable nuclear Fission Power Systems (FPSs) to support future exploration missions. A key deliverable is the Technology Demonstration Unit (TDU). The TDU will assemble the major elements of a notional FPS with a non-nuclear reactor simulator (Rx Sim) and demonstrate system-level performance in thermal vacuum. The Rx Sim includes an electrical resistance heat source and a liquid metal heat transport loop that simulates the reactor thermal interface and expected dynamic response. A power conversion unit (PCU) generates electric power utilizing the liquid metal heat source and rejects waste heat to a heat rejection system (HRS). The HRS includes a pumped water heat removal loop coupled to radiator panels suspended in the thermal-vacuum facility. The basic test plan is to subject the system to realistic operating conditions and gather data to evaluate performance sensitivity, control stability, and response characteristics. Upon completion of the testing, the technology is expected to satisfy the requirements for Technology Readiness Level 6 (System Demonstration in an Operational and Relevant Environment) based on the use of high-fidelity hardware and prototypic software tested under realistic conditions and correlated with analytical predictions.

Mason, Lee↗

Europa Clipper Magnetometer Thermal Design Evolution, Validation, and Verification

Europa Clipper Spacecraft is exposed to a high radiation environment and is limited with power. This makes the thermal design of Europa Clipper magnetometer more challenging. The design is required to be highly insulated and at the same time magnetically clean. This paper describes the thermal design evolution of Europa Clipper Magnetometer. A thermal vacuum test is conducted in Europa Clipper orbit’s relevant environment to characterize the requirements and estimate the power consumption. A flight-like engineering model magnetometer from the University of California at Los Angeles (UCLA) is used for this test. Magnetically clean Cernox temperature measurement sensors with the accuracy of ±0.1ºC are used to measure the temperature value inside the sensor head and across the main frame interfaces. This level of accuracy in temperature measurement is required to capture the temperature gradient across the sensor head in a relevant environment which impacts the magnetometer measurement accuracy. Test data is used to correlate the thermal model and characterize the heat leak across the interfaces. Validated thermal model is used as a verification tool for power consumption and thermal requirements.

Caron, Ryan↗

Stagnation Point Convective Heating Correlations for Entry Into H2/He Atmospheres

New convective heating correlations have been developed over a broad range of entry conditions into H2/He atmospheres. The correlations are based on calculations of stagnation point convective heat fluxes over a large range of velocities, densities, and effective nose radii. The heat fluxes and corresponding flowfields are computed using NASA’s hypersonic computational fluid dynamics code, DPLR. Cases in this study have been computed using both a temperaturelimited, radiative equilibrium wall and a cold wall temperature boundary condition. The results for the scaled heat flux, as a function of the difference in freestream and wall enthalpies, show a clear deviation from the linear trend predicted by the method of Sutton and Graves. Therefore, updated non-linear correlations are proposed for the prediction of stagnation point convective heat fluxes. Generally, these updated correlations predict lower heat loads and therefore smaller required TPS thicknesses when compared to previous correlations for a range of test cases in the Neptune, Saturn, and Uranus atmospheres.

Alex T. Carroll↗

Stagnation Point Convective Heating Correlations for Entry Into H2/He Atmospheres

New convective heating correlations have been developed over a broad range of entry conditions into H2/He atmospheres. The correlations are based on calculations of stagnation point convective heat fluxes over a large range of velocities, densities, and effective nose radii. The heat fluxes and corresponding flow fields are computed using NASA’s hypersonic computational fluid dynamics code, DPLR. Cases in this study have been computed using both a temperature limited, radiative equilibrium wall and a cold wall temperature boundary condition. The results for the scaled heat flux, as a function of the difference in freestream and wall enthalpies, show a clear deviation from the linear trend predicted by the method of Sutton and Graves. Therefore, updated non-linear correlations are proposed for the prediction of stagnation point convective heat fluxes. Generally, these updated correlations predict lower heat loads and therefore smaller required TPS thicknesses when compared to previous correlations for a range of test cases in the Neptune, Saturn, and Uranus atmospheres.

Alex T. Carroll↗

Measurement System Analysis of a Novel Phase-Based Ultrasonic NDE Technique for Bond Strength Measurement

Fiber reinforced polymer parts have shown tremendous benefits in aerospace structural applications, but their qualification and certification for use in safety critical areas are currently hindered by the lack of a capable non-destructive evaluation (NDE) method or technique for the inspection of these adhesively bonded parts. Conventional NDE methods and techniques typically detect gross bond defects in a qualitative (Pass/Fail) manner. These techniques struggle to detect weak or kissing bonds. Also, there are no widely adopted NDE methods or techniques for measuring interfacial bond strength or detecting kissing bonds. Bond strength is currently ensured by process control and semi-destructive testing. Results from recent research from other authors, including but not limited to mechanical testing, have shown an excellent correlation between interfacial stiffness of an adhesively bonded joint and the adhesive bond strength of that joint. In this paper, a measurement system analysis (MSA) of a novel phase-based ultrasonic NDE Technique, developed at NASA Langley Research Center, is presented for bond strength measurement to assess at an increased level the measurement process and identify components of variation in that measurement process.

Ultrasound↗

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Small-Column Ion Exchange Testing of Spherical Resorcinol-Formaldehyde

Ion exchange using the Spherical Resorcinol-Formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in an at-tank deployment. Numerous studies have shown the SRF resin to be effective for removing Cs-137 from a wide variety of actual and simulated tank waste supernatants. Prior work focused primarily on the loading behavior for 5 M sodium (Na) solutions at 25°C and the eluting behavior of the loaded SRF resin with virgin 0.5 M HNO3. Recent proposed changes to the process baseline indicate that loading may include a broader range of sodium molarities (2 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. In addition, elution will likely utilize variable-strength recycled nitric acid containing trace amounts of Cs-137. Cesium ion exchange loading and elution curves were generated for a 5 M Na, 2.4E-05 M Cs loading solution traced with Cs-134 followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with Cs-137. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small (~15 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45°C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with approximately 25 BVs of HNO3 processed at 25°C and at 1.4 BV/hr. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium bleed), to help establish acid strength and purity requirements.

Brown, Garrett N.↗

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗

Mechanical characterization of an additively manufactured Inconel 718 theta-shaped specimen

Two sets of “theta”-shaped specimens were additively manufactured with Inconel 718 powders using an electron beam melting technique with two distinct scan strategies. Light optical microscopy, mechanical testing coupled with a digital image correlation (DIC) technique, finite element modeling, and neutron diffraction with in situ loading characterizations were conducted. The cross-members of the specimens were the focus. Light optical micrographs revealed that different microstructures were formed with different scan strategies. Ex situ mechanical testing revealed each build to be stable under load until ductility was observed on the cross-members before failure. The elastic moduli were determined by forming a correlation between the elastic tensile stresses determined from FEM, and the elastic strains obtained from DIC. The lattice strains were mapped with neutron diffraction during in situ elastic loading; and a good correlation between the average axial lattice strains on the cross-member and those determined from the DIC analysis was found. Lastly, the spatially resolved stresses in the elastic deformation regime are derived from the lattice strains and increased with applied load, showing a consistent distribution along the cross-member.

36 MATERIALS SCIENCE↗