Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

Variability of Power from Large-Scale Solar Photovoltaic Scenarios in the State of Gujarat (Presentation)

India has ambitious goals for high utilization of variable renewable power from wind and solar, and deployment has been proceeding at a rapid pace. The western state of Gujarat currently has the largest amount of solar generation of any Indian state, with over 855 Megawatts direct current (MWDC). Combined with over 3,240 MW of wind, variable generation renewables comprise nearly 18% of the electric-generating capacity in the state. A new historic 10-kilometer (km) gridded solar radiation data set capturing hourly insolation values for 2002-2011 is available for India. We apply an established method for downscaling hourly irradiance data to one-minute irradiance data at potential PV power production locations for one year, 2006. The objective of this report is to characterize the intra-hour variability of existing and planned photovoltaic solar power generation in the state of Gujarat (a total of 1.9 gigawatts direct current (GWDC)), and of five possible expansion scenarios of solar generation that reflect a range of geographic diversity (each scenario totals 500-1,000 MW of additional solar capacity). The report statistically analyzes one year's worth of power variability data, applied to both the baseline and expansion scenarios, to evaluate diurnal and seasonal power fluctuations, different timescales of variability (e.g., from one to 15 minutes), the magnitude of variability (both total megawatts and relative to installed solar capacity), and the extent to which the variability can be anticipated in advance. The paper also examines how Gujarat Energy Transmission Corporation (GETCO) and the Gujarat State Load Dispatch Centre (SLDC) could make use of the solar variability profiles in grid operations and planning.

14 SOLAR ENERGY↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Grid Support Functionality Testing for Florida Power and Light

This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are being required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance analysis between the four test inverters. Inverters were mostly able to meet the requirements of their stated GSF capabilities, with deviations from expected results discussed throughout the report. There were mixed results across the range of abnormal tests, and results were often dependent on the capability of each test inverter to deploy the GSFs of interest. Detailed test data has been provided to FPL to support future decision making with respect to inverter selection and GSF deployment in the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bias Correction and Statistical Downscaling of Solar Radiation Using NA-CORDEX and the NSRDB

The current state-of-art for estimating long-term PV production uses long-term estimates of solar radiation variables, such as global horizontal irradiance (GHI), from previous years. This data is used in models such as the System Advisor Model (SAM) or PYSyst to predict annual production for a PV plant. This information is then used to estimate the production over the next 20 years (a typical plant lifetime) under the assumption that the variability over the current period is representative of the future. As the PV industry moves to extend plant lifetimes to 50 years the current assumptions of representativeness of weather may not be appropriate. This is especially true as our climate changes rapidly. To assess long-term PV production, future projections for solar radiation based on projected carbon emissions are readily available in regional and global climate models. However, climate model projections contain inherent biases that may need to be corrected for accurate analysis of future projections of climate variables. Several studies have analyzed projections of solar radiation for future years, however the accuracy of the model output compared to current and historic data has not been widely studied. Chen (2021) showed that available climate models do not accurately represent solar radiation in some cases, over-projecting GHI at the surface while under-projecting its obstructions, such as clouds and aerosols. This works aims to (1) increase understanding of the accuracy of solar radiation currently available in global and regional climate models and (2) implement bias correction through linear models based on reanalysis data compared to observed solar radiation. The latter aim will be conducted using available observed solar radiation data and modeled data from several regional climate models (RCMs). The bias correction method will be applied to projections of solar radiation resulting in a more accurate representation of the future of solar production.

climate data↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

Fabrication methods for high reflectance dielectric-metal point contact rear mirror for optoelectronic devices

The patterned dielectric back contact (PDBC) structure can be used to form a point-contact architecture that features a dielectric spacer with spatially distributed, reduced-area metal point contacts between the semiconductor back not recognized contact layer and the metal back contact. In this structure, the dielectric-metal region provides higher reflectance and is electrically insulating. Reduced-area metal point contacts provide electrical conduction for the back contact but typically have lower reflectance. The fabrication methods discussed in this article were developed for thermophotovoltaic cells, but they apply to any III-V optoelectronic device requiring the use of a conductive and highly reflective back contact. Patterned dielectric back contacts may be used for enhanced sub-bandgap reflectance, for enhanced photon recycling near the bandgap energy, or both depending on the optoelectronic application. The following fabrication methods are discussed in the article: PDBC fabrication procedures for spin-on dielectrics and commonly evaporated dielectrics to form the spacer layer; methods to selectively etch a parasitically absorbing back contact layer using metal point contacts as an etch mask; methods incorporating a dielectric etch through different process techniques such as reactive ion and wet etching.

14 SOLAR ENERGY↗

Clean Energy Technologies for Economic Development at Global and Community Scales

Energy systems in communities across the world are undergoing fundamental transformations. Electricity and heat production is becoming cleaner and more distributed, driven by declining energy prices and higher technology efficiencies, as well as a desire to reduce environmental impact. The technologies that produce clean energy, such as solar photovoltaic panels, wind turbines, and lithium ion batteries for vehicles and storage, depend less on global fuel costs and more on costs for technology, manufacturing, and local resources. Therefore, innovations in manufacturing, systems integration, operations, and policies can reduce clean energy costs across all the links in the energy supply chain. The advanced and cleaner energy systems being deployed have resulted in communities gaining a greater role in creating and using energy from local resources, as well as increasing their participation in the value chain from research, manufacturing, and deployment. The clean energy trends are expected to continue and perhaps grow through expansion of clean energy technologies for industrial and transportation sectors, although there are many possible future scenarios due to the diversity of resources and societal objectives in different communities, countries, and regions. This presentation will summarize the status and potential futures of key clean energy technologies and their manufacturing and deployment, with discussion of opportunities for sustainable communities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

CONSTRAINING THE OUTBURST PROPERTIES OF THE SMBH IN FORNAX A THROUGH X-RAY, INFRARED, AND RADIO OBSERVATIONS

Combined Spitzer, Chandra, XMM-Newton, and VLA observations of the giant radio galaxy NGC 1316 (Fornax A) show a radio jet and X-ray cavities from active galactic nucleus (AGN) outbursts most likely triggered by a merger with a late-type galaxy at least 0.4 Gyr ago. We detect a weak nucleus with a spectral energy distribution typical of a low-luminosity AGN with a bolometric luminosity of 2.4 x 10{sup 42} erg s{sup -1}. We examine the Spitzer IRAC and MIPS images of NGC 1316. We find that the dust emission is strongest in regions with little or no radio emission and that the particularly large infrared luminosity relative to the galaxy's K-band luminosity implies an external origin for the dust. The inferred dust mass implies that the merger spiral galaxy had a stellar mass of (1-6) x10{sup 10} M{sub sun} and a gas mass of (2-4) x10{sup 9} M{sub sun}. X-ray cavities in the Chandra and XMM-Newton images likely result from the expansion of relativistic plasma ejected by the AGN. The soft (0.5-2.0 keV) Chandra images show a small {approx}15'' (1.6 kpc) cavity coincident with the radio jet, while the XMM-Newton image shows two large X-ray cavities lying 320'' (34.8 kpc) east and west of the nucleus, each approximately 230'' (25 kpc) in radius. Current radio observations do not show emission within these cavities. The radio lobes lie at radii of 14.'3 (93.3 kpc) and 15.'6 (101 kpc), more distant from the nucleus than the detected X-ray cavities. The relative morphology of the large scale 1.4 GHz and X-ray emission suggests they were products of two distinct outbursts, an earlier one creating the radio lobes and a later one producing the X-ray cavities. Alternatively, if a single outburst created both the X-ray cavities and the radio lobes, this would require that the radio morphology is not fully defined by the 1.4 GHz emission. For the more likely two outbursts scenarios, we use the buoyancy rise times to estimate an age for the more recent outburst that created the X-ray cavities of 0.1 Gyr and the PV work done by the expanding plasma that created the X-ray cavities to estimate the outburst's energy to be 10{sup 58} erg. The present size and location of the radio lobes imply that the outburst that created them happened {approx}0.4 Gyr ago and released {approx}5 x 10{sup 58} erg.

79 ASTRONOMY AND ASTROPHYSICS↗

Forecasting for the Weather Driven Energy System - A New Task under IEA Wind

The energy system needs a range of forecast types for its operation in addition to the narrow wind power forecast that has been the focus of considerable recent attention. Therefore, the group behind the former IEA Wind Task 36 Forecasting for Wind Energy has initiated a new IEA Wind Task with a much broader perspective, which includes prospective interaction with other IEA Technology Collaboration Programmes such as the ones for PV, hydropower, system integration, hydrogen etc. In the new IEA Wind Task 51 (entitled "Foreacsting for the Weather Drive Energy System") the existing Work Packages (WPs) are complemented by work streams in a matrix structure. The Task is divided in three WPs according to the stakeholders: WP1 is mainly aimed at meteorologists, providing the weather forecast basis for the power forecasts. In WP2, the forecast service vendors are the main stakeholders, while the end users populate WP3. The new Task 51 started in January 2022. Planned activities include 4 workshops. The first will focus on the state of the art in forecasting for the energy system plus related research issues and be held during September 2022 in Dublin. The other three workshops will be held later during the 4-year Task period and address (1) seasonal forecasting with emphasis on Dunkelflaute, storage and hydro, (2) minute-scale forecasting, and (3) extreme power system events. The issues and conclusions of each of the workshops will be documented by a published paper. Additionally, the Recommended Practice on Forecast Solution Selection will be updated to reflect the broader perspective.

geophysics computing↗

Evaluation of Multi-Inverter Anti-Islanding with Grid Support and Ride-Through and Investigation of Island Detection Alternatives

As utility interconnected photovoltaic systems (PV) become integrated into the electrical power system (EPS) at an increasing rate, utilities and regulators have become concerned about the potential for increased voltage and frequency deviations as well as EPS reliability and resiliency. These concerns have initiated the need to amend the utility interconnection standard to allow advanced inverter control functionalities that provide: (1) reactive power control for voltage support, (2) real (active) power control for frequency support and (3) voltage and frequency ride- through for bulk system support. The new real and reactive power modulation are intended to reduce EPS voltage and frequency deviations by mimicking the droop and excitation controls of conventional generation. The new ride-through capabilities are needed to prevent a large quantity of generation from autonomously de-energizing or disconnecting in response to a voltage or frequency deviation. These changes, however, may have the potential to interfere with autonomous anti-islanding, especially when multiple inverters from different vendors are co-located on one bus. This report presents results from an investigation of multi-inverter autonomous anti- islanding with advanced functions, and the development of a means to mitigate adverse interaction between the two.

14 SOLAR ENERGY↗

Searches for Physics beyond the Standard Model

The Thomas Jefferson National Accelerator Laboratory has the demonstrated ability to test the fundamental symmetries of nature to very great precision and thereby probe for new physics beyond the Standard Model (SM). In the following objectives and descriptions will be given of three Jefferson Laboratory (JLab) experiments: Qweak, MOLLER, and PVDIS. The Qweak experiment is to measure the weak charge of the proton (via the vector coupling of the Z0 boson to the proton). The MOLLER experiment is to measure the weak charge of the electron. The PV-DIS experiment will measure combinations of vector couplings and axial-vector couplings to the quarks of the nucleons. These three experiments follow from the advances made in precision parity-violating electron scattering measurements at the CEBAF of JLab. The Standard Model makes accurate predictions of the 'running' of the electroweak mixing angle or sin2(θw) from the Z0 pole down to low energies and therefore of the weak charges of the proton and electron. The Qweak experiment will make the first precision determination of the weak charge of the proton, Qpw = 1 – 4 sin2 (θw), from a measurement of the parity-violating asymmetry in the elastic scattering of longitudinally polarized electrons from the protons in a liquid hydrogen target at very low momentum transfer. The projected result will determine the proton's weak charge with a 4.1% total error and consequently sin2 (θw) with a 0.3% error. The Qweak experiment is at present three months into its commissioning run. The MOLLER experiment is to measure the parity-violating asymmetry in the scattering of 11 GeV longitudinally polarized electrons from the atomic electrons in a liquid hydrogen target. The longitudinal analyzing power Az is predicted to be 35.6 ppb at the kinematics of the experiment and is to be determined with a precision of 0.73 ppb, which would make the MOLLER experiment the most precise parity-violation experiment ever undertaken. The result would yield a measurement of the weak charge of the electron to 2.3% at an average Q2 value of 0.0056 (GeV/c)2 and in turn a determination of the electroweak mixing angle sin2(θw) with an uncertainty of ±0.00026 (stat) ±0.00013 (syst), comparable to the accuracy of the two best determinations at the Z0 pole. The PVDIS experiment is to measure the parity-violating asymmetry in deep inelastic scattering of longitudinally polarized electrons from an unpolarized deuterium target. The longitudinal analyzing power can be expressed in terms of the quark distribution functions of the deuterium target and the couplings C1q (axial electron x vector quark) and C2q (vector electron x axial quark), which in the Standard Model can be expressed in terms of sin2(θw).

08 HYDROGEN↗

Mineralogy and Thermal Properties of V-Type Asteroid 956 Elisa: Evidence for Diogenitic Material from the Spitzer IRS (5-35 Micrometers) Spectrum

We present the thermal infrared (5-35 micrometer) spectrum of 956 Elisa as measured by the Spitzer Infrared Spectrograph ("IRS"; Houck,1.R. et .11. [20041. Astrophys, 1. SuppL 154, 18-24) together with new ground-based lightcurve data and near-IR spectra. From the visible lightcurve photometry, we determine a rotation period of 16.494 +/- 0.001 h, identify the rotational phase of the Spitzer observations, and estimate the visible absolute magnitude (Hv) at that rotational phase to be 12.58 +/- 0.04. From radiometric analysis of the thermal flux spectrum, we find that at the time of observation 956 Elisa had a projected radius of 5.3 +/- 0.4 km with a visible albedo pv = 0.142+/- 0.022, significantly lower than that of the prototype V-type asteroid, 4 Vesta. (This corresponds to a radius of 5.2 +/- 0.4 km at lightcurve mean.) Analysis with the standard thermal model (STM) results in a sub-solar temperature of 292.3 +/- 2.8 K and beaming parameter eta = 1.16 +/- 0.05. Thermophysical modeling places a lower limit of 20 J m(exp -2)K(exp -1)s(exp -1/2) on the thermal inertia of the asteroid's surface layer (if the surface is very smooth) but more likely values fall between 30 and 150 J m(exp -2)K(exp -1)s(exp -1/2) depending on the sense of rotation. The emissivity spectrum, calculated by dividing the measured thermal flux spectrum by the modeled thermal continuum, exhibits mineralogically interpretable spectral features within the 9-12 micrometer reststrahlen band, the 15-16.5 micrometer Si-O-Si stretching region, and the 16-25 micrometer reststrahlen region that are consistent with pyroxene of diogenitic composition: extant diogenitic pyroxenes fall within the narrow compositional range W0(sub 2+/-1)En(sub 74+/-2)Fs(sub 24+/-1). Spectral deconvolution of the 9-12 micrometer reststrahlen features indicates that up to approximately 20% olivine may also be present, suggesting an olivine-diogenite-like mineralogy. The mid-IR spectrum is inconsistent with non-cumulate eucrite as the major component on the surface of 956 Elisa, although cumulate eucrite material may be present at abundances lower than that of the diogenite component. Analysis of new near-IR spectra of 956 Elisa with the Modified Gaussian Model (MGM; Sunshine, J,M., Pieters, C.M., Pratt, S.F.[1990]. J. Geophys. Res, 95 (May), 6955-6966) results in two pyroxene compositions: 75% magnesian low-Ca pyroxene and 25% high-Ca pyroxene. High-Ca pyroxene is not evident in the mid-IR data, but may belong to a component that is underrepresented in the mid-IR spectrum either because of its spatial distribution on the asteroid or because of its particle size. High-Ca pyroxenes that occur as exsolution lamellae may also be more evident spectrally in the NIR than in the mid-IR. In any case, we find that the mid-IR spectrum of 956 Elisa is dominated by emission from material of diogenite- like composition, which has very rarely been observed among asteroids.

Lim, Lucy F.↗

SolarAPP+ Performance Review (2022 Data)

The Solar Automated Permit Processing Plus (SolarAPP+) platform is an online portal to facilitate and expedite rooftop solar photovoltaic (PV) permitting processes. SolarAPP+ allows PV contractors to upload system specifications, have those specifications automatically reviewed for code compliance, and receive instant approval for code-compliant systems. SolarAPP+ also provides inspection checklists to verify installation practices and adherence to approved designs. SolarAPP+ is available to authorities having jurisdiction (AHJs) at no cost. This report is part of an ongoing series of reviews of SolarAPP+ performance. Consistent with previous performance reviews, we summarize SolarAPP+ adoption trends to date and compare various metrics for PV systems permitted through SolarAPP+ versus systems permitted through conventional AHJ permitting processes. As of the end of 2022, the National Renewable Energy Laboratory (NREL) had contacted over 1,500 AHJs with significant solar permitting volume regarding SolarAPP+. Of those, 607 AHJs had at least expressed interest in the platform. 16 AHJs had begun piloting the platform and 15 of these had publicly launched the platform by the end of 2022. In 2022, 206 installers submitted 11,092 permits through the SolarAPP+ platform, including 708 permits for solar+storage systems. SolarAPP+ permits accounted for around 37% of all permits issued in participating AHJs. We compare permitting timelines through SolarAPP+ to traditional AHJ permitting processes to assess the platform's performance. Consistent with previous SolarAPP+ performance reviews, we find that permitting timelines are significantly shorter for SolarAPP+ projects. Based on median timelines, a typical SolarAPP+ project is permitted and inspected 8 business days sooner than traditional projects. We estimate that automatic SolarAPP+ permitting saved between 3,500 and 13,900 hours of AHJ staff time in 2022. Finally, we find evidence that SolarAPP+ may improve inspection outcomes, with SolarAPP+ projects failing inspections about 28% less frequently than traditional projects.

14 SOLAR ENERGY↗