Technology Performance Exchange
Building Technologies Office's commercial building integration project
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Building Technologies Office's commercial building integration project
Building Technologies Office's commercial building integration project 2013
Building Technologies Office's commercial building integration project 2013
Building Technologies Office's commercial building integration project 2013
Building Technologies Office's commercial building integration project 2013
Energy performance contracts can be an effective way to integrate comprehensive water-efficient technologies and solutions into energy efficiency projects. Current practices often miss key opportunities to incorporate a full suite of water measures primarily because a comprehensive approach is not taken in the assessment. This article provides information on how to develop a comprehensive water project that leads to innovative solutions and potential for large water reduction.
Watch how NREL researchers are using the unique capabilities of the Energy Systems Integration Facility (ESIF) to develop technologies that will help the “smart” homes and buildings of the future perform efficiently and communicate effectively with the electricity grid while enhancing occupants' comfort and convenience.
Reducing the energy consumption of large institutions with dozens to hundreds of existing buildings while maintaining and improving existing infrastructure is a critical economic and environmental challenge. SNL's Institutional Transformation (IX) work integrates facilities and infrastructure sustainability technology capabilities and collaborative decision support modeling approaches to help facilities managers at Sandia National Laboratories (SNL) simulate different future energy reduction strategies and meet long term energy conservation goals.
Described herein are various technologies pertaining to authentication of integrated circuits by using external factors to affect or modify an output of a physically unclonable function (PUF) circuit. In an example, the output of the PUF circuit in response to a challenge signal can be sensitive to changes in environmental factors. In another example, the output of the PUF circuit can be sensitive to user-selectable configuration parameters of the PUF circuit. In yet another example, the output of the PUF circuit can be modified by additional circuitry external to the PUF circuit based upon one or more selectable or configurable inputs. A PUF-based device authentication system that uses external factors as authentication inputs to affect a challenge response of the device authentication system can enhance authentication capabilities by permitting multi-factor authentication.
Described herein are various technologies pertaining to confirming an integrity of a FPGA. A verifier circuit is placed into an FPGA bitstream to enable external verification of the FPGA configuration in real time without requiring readout of the FPGA configuration itself. Number generators are utilized to generate a key which is shared between the FPGA and an external verification component (VC). The key is utilized to configure an initial state of sequence registers respectively located on both the FPGA and the VC. When the FPGA is operating with an approved configuration, output from the sequence registers at the FPGA and the VC are the same.
The various technologies presented herein relate to integrating an IC having at least one waveguide incorporated therein with a v-groove array IC such that an optical fiber located in a v-groove is aligned relative to a waveguide in the IC maximizing optical coupling between the fiber and the waveguide. The waveguide IC and the v-groove array IC are bonded in a stacked configuration. Alignment of the waveguide IC and the array IC in the stacked configuration enables advantage to be taken of lithographic accuracy of features formed with respect to the Z-direction. Further, kinematic pins and sockets are utilized to provision accuracy in the X- and Z-directions, wherein advantage is taken of the placement accuracy and fabrication tolerance(s) which can be utilized when forming the and sockets. Accordingly, automated alignment of the waveguide IC and the array IC is enabled, facilitating accurate alignment of the respective waveguides and fibers.
Distributed acoustic sensors (DAS) have shown remarkable success in monitoring critical civil, energy and transportation assets over long distances and under harsh environmental conditions. Integration of artificial intelligence (AI) technologies with DAS can extend their operational capabilities from conventional tasks (e.g., vibration frequency detection) to more advanced intelligent tasks like anomaly detection. However, these AI technologies often require large labeled/ annotated DAS measurements datasets of the assets in both normal and anomalous operating conditions. This data acquisition task can be both time consuming and costly. This work develops a generative adversarial network based unsupervised domain adaptation framework to build intelligent DAS operational capabilities.
If a number of technical, financial and regulatory hurdles can be overcome, power generated by integrated gasification combined-cycle technology could become an important source for US utilities. Our overview presents diverse perspectives from three industry experts about what it will take to move this technology off the design table and into the field. Well-known advantages are IGCC uses less water, creates a usable slag by-product and the technology required for pre-combustion CO{sub 2} capture has already been used successfully on coal gasification technology. These points, together with roadblocks to the deployment of IGCC technology in the USA, are discussed. 3 figs., 1 tab.
Instrumentation and Control (I and C) systems of the latest nuclear power plants are based on the use of digital technology, distributed control systems and the integration of information in data networks (Distributed Control and Instrumentation Systems). This has a repercussion on Control Rooms (CRs), where the operations and monitoring interfaces correspond to these systems. These technologies are also used in modernizing I and C systems in currently operative nuclear power plants. The new interfaces provide additional capabilities for operation and supervision, as well as a high degree of flexibility, versatility and reliability. An example of this is the implementation of solutions such as compact stations, high level supervision screens, overview displays, computerized procedures, new operational support systems or intelligent alarms processing systems in the modernized Man-Machine Interface (MMI). These changes in the MMI are accompanied by newly added Software (SW) controls and new solutions in automation. Tecnatom has been leading various projects in this area for several years, both in Asian countries and in the United States, using in all cases international standards from which Tecnatom own methodologies have been developed and optimized. The experience acquired in applying this methodology to the design of new control rooms is to a large extent applicable also to the modernization of current control rooms. An adequate design of the interface between the operator and the systems will facilitate safe operation, contribute to the prompt identification of problems and help in the distribution of tasks and communications between the different members of the operating shift. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (authors)
Environmental data is often complex, and it can be difficult to provide proper context to fully understand and comprehensively analyze the data. One tool identified to better present complicated data is the use of web-based Geographic Information Systems (GIS). Web-based GIS provides much-needed visual context to the complex data collected at Los Alamos National Laboratory (LANL). By overlaying environmental data atop relevant geographical features, such as topography, surface or subsurface geology, hydrogeological features, buildings, roads, and technical areas, LANL's diverse group of stakeholders are better able to understand environmental data collected at the LANL site within the framework of the surrounding geography. Since 2012, Los Alamos has utilized a web-based GIS module in the Intellus New Mexico data-sharing web site. This web site provides unfettered public access to LANL and New Mexico Environment Department (NMED) - Department of Energy (DOE) Oversight Bureau environmental data. Through the past five years of real world experience, LANL identified areas where questions and confusion arose, particularly for those not directly associated with the site's environmental cleanup mission. In order to query the millions of records in Intellus in a meaningful way, users had to have substantial knowledge of the data organization and nomenclature ahead of time. While this was not a challenge for LANL and NMED environmental scientists, it proved to be a substantial barrier for members of the general public to utilize Intellus. In 2017, LANL initiated an Intellus redesign with the goal of deconstructing the type of questions people asked and identifying the types of user personas accessing the site to engineer a simpler path to desired data sets. Greatly simplified click paths ('Quick Paths') were created that walk the user through the basics with a minimum of jargon and a strong reliance on mapping results for easy visualization. The improved mapping was enabled by an upgraded online GIS functionality that allowed LANL to easily integrate their own base-maps to provide users the most up to date views of their data. The integrated Intellus GIS was enhanced to assimilate with LANL's dynamic base maps and site information in relation to data collection activities, to avoid outdated presentations. A simplified user interface (UI) was added and easier data querying was designed. A more robust visual presentation was created that allowed better viewing of spatial data. All data queries in the new simplified 'Quick Path' give the users the option to map the results and save their results to their optional accounts. This brings the power of GIS visualization to all users without the need for GIS knowledge or extensive training. By integrating with Esri{sup R} technologies, base-map layers in ArcGIS Online{sup R} can be updated by LANL or other data providers at any time and reflected immediately in the Intellus mapping application called GIS+ 1. Users can even load additional map layers to GIS+ that contain their own spatial data or information shared from over a million users on ArcGIS Online{sup R}, such as ecological information from the Fish and Wildlife Service, or geology layers from the USGS. The results from the improved quick path search in Intellus can be viewed in GIS+ and analyzed using Esri's{sup R} Smart Mapping technology, which makes it easy to classify results with its visual representation of the results in an interactive histogram, where sliders can be dragged to look at various intervals for each color range for that query. With enhanced GIS+, Los Alamos National Laboratory is able to observe improve Stakeholder engagement and positive Stakeholder interactions within its public environmental database, Intellus New Mexico. (authors)
The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.
A digital twin enhances power grid control room operations by providing real-time monitoring, predictive insights, simulation capabilities, remote control, training opportunities, data integration, and decision support. This technology empowers control room operators to effectively manage the grid, optimize performance, and ensure reliable and efficient energy distribution.
Hydraulic and Clean-in-Place Evaluations for a 12.5 cm Annular Centrifugal Contactor at the INL Troy G. Garn, Dave H. Meikrantz, Nick R. Mann, Jack D. Law, Terry A. Todd Idaho National Laboratory Commercially available, Annular Centrifugal Contactors (ACC) are currently being evaluated for processing dissolved nuclear fuel solutions to selectively partition integrated elements using solvent extraction technologies. These evaluations include hydraulic and clean-in-place (CIP) testing of a commercially available 12.5 cm unit. Data from these evaluations is used to support design of future nuclear fuel reprocessing facilities. Hydraulic testing provides contactor throughput performance data on two-phase systems for a wide range of operating conditions. Hydraulic testing results on a simple two-phase oil and water system followed by a 30 % Tributyl phosphate in N-dodecane / nitric acid pair are reported. Maximum total throughputs for this size contactor ranged from 20 to 32 liters per minute without significant other phase carryover. A relatively new contactor design enhancement providing Clean-in-Place capability for ACCs was also investigated. Spray nozzles installed into the central rotor shaft allow the rotor internals to be cleaned, offline. Testing of the solids capture of a diatomaceous earth/water slurry feed followed by CIP testing was performed. Solids capture efficiencies of >95% were observed for all tests and short cold water cleaning pulses proved successful at removing solids from the rotor.