Search NASA⌕ Search

SEARCH · Search NASA

Results for “hardware testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Reliable automatic alignment of tomographic projection data by passive auto-focus

Purpose: The authors present a robust algorithm that removes the blurring and double-edge artifacts in high-resolution computed tomography (CT) images that are caused by misaligned scanner components. This alleviates the time-consuming process of physically aligning hardware, which is of particular benefit if components are moved or swapped frequently. Methods: The proposed method uses the experimental data itself for calibration. A parameterized model of the scanner geometry is constructed and the parameters are varied until the sharpest 3D reconstruction is found. The concept is similar to passive auto-focus algorithms of digital optical instruments. The parameters are used to remap the projection data from the physical detector to a virtual aligned detector. This is followed by a standard reconstruction algorithm, namely the Feldkamp algorithm. Feldkamp et al.[J. Opt. Soc. Am. A 1, 612-619 (1984)]. Results: An example implementation is given for a rabbit liver specimen that was collected with a circular trajectory. The optimal parameters were determined in less computation time than that for a full reconstruction. The example serves to demonstrate that (a) sharpness is an appropriate measure for projection alignment, (b) our parameterization is sufficient to characterize misalignments for cone-beam CT, and (c) the procedure determines parameter values with sufficient precision to remove the associated artifacts. Conclusions: The algorithm is fully tested and implemented for regular use at The Australian National University micro-CT facility for both circular and helical trajectories. It can in principle be applied to more general imaging geometries and modalities. It is as robust as manual alignment but more precise since we have quantified the effect of misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Super-B Project Accelerator Status

The SuperB project is an international effort aiming at building in Italy a very high luminosity e{sup +}e{sup -} (10{sup 36} cm{sup -2} sec{sup -1}) asymmetric collider at the Y(4S) energy in the CM. The accelerator design has been extensively studied and changed during the past year. The present design, based on the new collision scheme, with large Piwinski angle and the use of 'crab waist' sextupoles already successfully tested at the DA{Phi}NE {Phi}-Factory at LNF Frascati, provides larger flexibility, better dynamic aperture and spin manipulation sections in the Low Energy Ring (LER) for longitudinal polarization of the electron beam at the Interaction Point (IP). The Interaction Region (IR) has been further optimized in terms of apertures and reduced backgrounds in the detector. The injector complex design has been also updated. A summary of the project status will be presented in this paper. The SuperB collider can reach a peak luminosity of 10{sup 36} cm{sup -2} sec{sup -1} with beam currents and bunch lengths similar to those of the past and present e{sup +}e{sup -} Factories, through the use of smaller emittances and new scheme of crossing angle collision. The beams are stored in two rings at 6.7 GeV (HER) and 4.2 GeV (LER). Unique features of the project are the polarization of the electron beam in the LER and the possibility to decrease the energies for running at the {tau}/charm threshold. The option to reuse the PEP-II B-Factory (SLAC) hardware will allow reducing costs. The SuperB facility will require a big complex of civil infrastructure. The main construction, which will house the final part of the LINAC, the injection lines, the damping rings, and the storage rings, will be mainly underground. Two sites have been considered: the campus of Tor Vergata University near Frascati, and the INFN Frascati Laboratory. No decision has been made yet. A footprint of the possible SuperB layout on the LNF area is shown in Fig. 1.

43 PARTICLE ACCELERATORS↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of irradiation damage and heat deposition: a comparative analysis for HEU-to-LEU conversion in HFIR

The planned conversion of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel requires detailed evaluation of experiment-relevant parameters to ensure continued performance for materials testing and isotope production. Here, this study presents the first comprehensive assessment of displacements per atom (dpa) and heat deposition rates in target materials within the HFIR flux trap with both HEU and candidate LEU core configurations. Seven analyses were conducted to evaluate key performance metrics, including fast neutron flux distribution, cross section response functions, cross section data, and local dpa and heat deposition rates using mesh- and cell-based tallies. Simulations employed Shift, Monte Carlo N-Particle (MCNP), and the HIFR Controller (HFIRCON) tool suite for high-fidelity transport and depletion modeling. The LEU designs—using U 3 Si 2 -Al dispersion fuel and operating at 95 MW—were compared to the current 85 MW HEU configuration. Results show that while the candidate LEU cores exhibit higher dpa rates due to a harder spectrum and extended cycle lengths, they also demonstrate reduced heat deposition rates in irradiation experiments, primarily due to increased gamma self-shielding from higher 238 U content in the core. These findings confirm that LEU conversion can maintain HFIR’s materials irradiation capabilities but may require redesigning existing experimental hardware.

HEU↗

Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model-based approach is summarized as follows: Step 1, Cable Modeling: Given input-output TDR signals s(n) and x{sub U}(n) for a cable known to be free of damage, system identification algorithms are used to compute a dynamic prediction-error cable model that has output {cflx x}{sub U}(n). The model is declared valid when the innovations e{sub U}(n) = x{sub U}(n) {cflx x}{sub U}(n) satisfy a statistical zero-mean whiteness test. This validated model output is then used as a known reference to which other cables can be compared. Step 2, Cable Testing: The TDR output signal x{sub D}(n) from a cable under test is compared with the model output {cflx x}{sub U}(n) by computing the innovations e{sub D}(n) = x{sub D}(n) {cflx x}{sub U}(n). The innovations are tested using a short-term whiteness test statistic, which employs a statistical confidence interval. If the cable passes the test, this implies that the model is valid and the cable is declared undamaged. If the cable fails the test, this indicates a model mismatch, which means that the cable's dielectric properties have changed; and this implies that the cable is damaged. The test threshold is adjusted to maximize probability of detection and minimize probability of false alarm according to an empirically determined receiver operating characteristic (ROC) curve. An associated confidence interval on the probability of correct classification is also provided. The effectiveness of the algorithm is demonstrated using measured TDR signals for undamaged and damaged cables. Experimental and algorithmic methods for coping with repeatability issues are presented. The model-based damage detection algorithms have been shown to perform well for some representative examples of real TDR signals acquired using the two-dimensional (2D) mockup fixture. If the damage causes a short circuit, then damage detection performance is generally good to excellent. Examples include the cases demonstrated in this report for cuts and pinholes. If the damage does not cause a short circuit, then damage detection performance is generally poor to fair. Examples include the cases demonstrated in this report for crushes and partial cuts.

42 ENGINEERING↗

Search for heavy Majorana neutrinos in pp collisions at √s = 8 TeV with the CMS detector & photodetector and calorimeter R&D for particle colliders

This thesis contains both physics analysis and hardware studies. It consists of two primary sections: the results of a search for heavy Majorana mass neutrinos, using the event signature of same (like) sign charged electron pairs ($e^{\pm} e^{\pm}$ ) and two jets, and the results of studies to upgrade the Hadronic Forward (HF) and Hadronic Endcap (HE) subdetectors in the Compact Muon Solenoid (CMS) detector in response to the high intensity proton-proton collisions generated at the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN, Conseil Europ\'{e}en pour la Recherche Nucl\'{e}aire). In this search for Majorana mass neutrinos, same sign dielectron ($e^{\pm} e^{\pm}$) + dijet events in the final state have been considered as a signature for neutrino particles. The analyzed data corresponds to an integrated luminosity of 19.7 fb\textsuperscript{-1} of proton-proton collisions at a center of mass energy of $\sqrt{s} = 8 \text{TeV}$, collected using the CMS detector during the 2012 operation at the LHC. Monte Carlo simulations accounting for the theoretical expectations of the Standard Model (SM) and the detector limitations are used to prototype the experiment and to test proposed analysis steps. No excess of events is observed in the data beyond the expected SM background. Upper limits are set on the mixing element squared, $|{V}_{eN}|^{2}$, of the heavy Majorana neutrino with standard model neutrinos, as a function of Majorana neutrino mass for masses in the range of 40-500 $GeV/c^2$. The detector upgrade search comprises three sections of this thesis. The first section describes the test results of 1785 multianode Hamamatsu R7600U-200-M4 photomultiplier tubes (PMT) in numerous parameters such as gain, dark current, and timing characteristics, which provide insights on the expected performance of the upgraded CMS-HF detector. These PMTs replaced the previous single anode R7525 PMTs because the glass windows of previous PMTs are the source of Cherenkov radiation, which causes a background noise in the experiment. The second section reports characterization results of two types of PMTs in a novel operation mode for Secondary Emission (SE) Ionization Calorimetry, which is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The third section presents the test results of novel scintillating materials for CMS experiment in specific and future particle accelerators in general. These materials are Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), high efficiency mirror (HEM) and quartz plates with various organic and inorganic coating materials such as p-Terphenyl (pTp), Anthracene and Gallium-doped Zinc Oxide (ZnO:Ga). We have investigated them for radiation hardness, light yield, timing characteristics, and scintillation and transmission properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extended Durability Testing of an External Fuel Processor for a Solid Oxide Fuel Cell (SOFC)

Durability testing was performed on an external fuel processor (EFP) for a solid oxide fuel cell (SOFC) power plant. The EFP enables the SOFC to reach high system efficiency (electrical efficiency up to 60%) using pipeline natural gas and eliminates the need for large quantities of bottled gases. LG Fuel Cell Systems Inc. (formerly known as Rolls-Royce Fuel Cell Systems (US) Inc.) (LGFCS) is developing natural gas-fired SOFC power plants for stationary power applications. These power plants will greatly benefit the public by reducing the cost of electricity while reducing the amount of gaseous emissions of carbon dioxide, sulfur oxides, and nitrogen oxides compared to conventional power plants. The EFP uses pipeline natural gas and air to provide all the gas streams required by the SOFC power plant; specifically those needed for start-up, normal operation, and shutdown. It includes a natural gas desulfurizer, a synthesis-gas generator and a start-gas generator. The research in this project demonstrated that the EFP could meet its performance and durability targets. The data generated helped assess the impact of long-term operation on system performance and system hardware. The research also showed the negative impact of ambient weather (both hot and cold conditions) on system operation and performance.

08 HYDROGEN↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Entity—Hardware-agnostic Particle-in-cell Code for Plasma Astrophysics. I. Curvilinear Special Relativistic Module

Entity is a new-generation, fully open-source particle-in-cell (PIC) code developed to overcome key limitations in astrophysical plasma modeling, particularly the extreme separation of scales and the performance challenges associated with evolving, GPU-centric computing infrastructures. It achieves hardware-agnostic performance portability across various GPU and CPU architectures using the Kokkos library. Crucially, Entity maintains a high standard for usability, clarity, and customizability, offering a robust and easy-to-use framework for developing new algorithms and grid geometries, which allows extensive control without requiring edits to the core source code. This paper details the core general-coordinate special relativistic module. Entity is the first PIC code designed to solve the Vlasov–Maxwell system in general coordinates, enabling a coordinate-agnostic framework that provides the foundational structure for straightforward extension to arbitrary coordinate geometries. The core methodology achieves numerical stability by solving particle equations of motion in the global orthonormal Cartesian basis, despite using generalized coordinates like Cartesian, axisymmetric spherical, and quasi-spherical grids. Charge conservation is ensured via a specialized current deposition technique using conformal currents. The code exhibits robust scalability and performance portability on major GPU platforms (AMD MI250X, NVIDIA A100, and Intel Max Series), with the 3D particle pusher and the current deposition operating efficiently at about 2 ns per particle per time step. Functionality is validated through a comprehensive suite of standard Cartesian plasma tests and the accurate modeling of relativistic magnetospheres in curvilinear axisymmetric geometries.

Hakobyan, Hayk [Flatiron Institute, New York, NY (↗

Final Focus Test Facility ATF2 Status

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometre level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European and American scientists. In this paper, the present status and performance of the recently deployed ATF2 systems are briefly described, based on the first experience with beam measurements and tuning during winter, spring and early autumn of 2009. The near and longer term plans are outlined as well. The ATF collaboration has completed the construction of ATF2 and has started its commissioning. Important experience operating the new cavity BPM and BSM instrumentation in real conditions has been gained and first beam measurements have been performed in a magnetic configuration with reduced optical demagnification. Both horizontal and vertical emittances were successfully tuned and measured in the extraction line, with values approaching the design values of 2 nm and 12 pm, respectively. First checks of the first order optics along the beam line and at the IP were also done. Hardware developments for the second ATF2 goal are being pursued in parallel with the present commissioning work for the first goal. The collaboration is also preparing several near and long terms plans for ATF2. In the next few years, information very valuable for any future collider with local chromaticity correction and tuning of very low emittance beams can be expected. In the previous experience at the FFTB, the smallest vertical beam sizes which were achieved were about 70 nanometers. The work described here continues to address this largely unexplored regime in a systematic way.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-231: Comparison of Delineation Variability of Soft Tissue Volume and Position in Head-And-Neck Between Two T1-Weighted Pulse Sequences Using An MR-Simulator with Immobilization

Purpose: There is growing interests in applying MR-simulator(MR-sim) in radiotherapy but MR images subject to hardware, patient and pulse sequence dependent geometric distortion that may potentially influence target definition. This study aimed to evaluate the influence on head-and-neck tissue delineation, in terms of positional and volumetric variability, of two T1-weighted(T1w) MR sequences on a 1.5T MR-sim Methods: Four healthy volunteers were scanned (4 scans for each on different days) using both spin-echo (3DCUBE, TR/TE=500/14ms, TA=183s) and gradient-echo sequences (3DFSPGR, TE/TR=7/4ms, TA=173s) with identical coverage, voxel-size(0.8×0.8×1.0mm3), receiver-bandwidth(62.5kHz/pix) and geometric correction on a 1.5T MR-sim immobilized with personalized thermoplastic cast and head-rest. Under this setting, similar T1w contrast and signal-to-noise ratio were obtained, and factors other than sequence that might bias image distortion and tissue delineation were minimized. VOIs of parotid gland(PGR, PGL), pituitary gland(PIT) and eyeballs(EyeL, EyeR) were carefully drawn, and inter-scan coefficient-of-variation(CV) of VOI centroid position and volume were calculated for each subject. Mean and standard deviation(SD) of the CVs for four subjects were compared between sequences using Wilcoxon ranksum test. Results: The mean positional(<4%) and volumetric(<7%) CVs varied between tissues, majorly dependent on tissue inherent properties like volume, location, mobility and deformability. Smaller mean volumetric CV was found in 3DCUBE, probably due to its less proneness to tissue susceptibility, but only PGL showed significant difference(P<0.05). Positional CVs had no significant differences for all VOIs(P>0.05) between sequences, suggesting volumetric variation might be more sensitive to sequence-dependent delineation difference. Conclusion: Although 3DCUBE is considered less prone to tissue susceptibility-induced artifact and distortion, our preliminary data showed that both sequences had insignificant differences on positional and volumetric CV in most head-and-neck tissues except for PGL. This study is majorly limited in its small sample size. Influences of image contrasts(T1w v.s. T2w) and inter-observer difference have to be further investigated.

60 APPLIED LIFE SCIENCES↗

HOMER Economic Models - US Navy

This LETTER REPORT has been prepared by Idaho National Laboratory for US Navy NAVFAC EXWC to support in testing pre-commercial SIREN (Simulated Integration of Renewable Energy Networks) computer software models. In the logistics mode SIREN software simulates the combination of renewable power sources (solar arrays, wind turbines, and energy storage systems) in supplying an electrical demand. NAVFAC EXWC will create SIREN software logistics models of existing or planned renewable energy projects at five Navy locations (San Nicolas Island, AUTEC, New London, & China Lake), and INL will deliver additional HOMER computer models for comparative analysis. In the transient mode SIREN simulates the short time-scale variation of electrical parameters when a power outage or other destabilizing event occurs. In the HOMER model, a variety of inputs are entered such as location coordinates, Generators, PV arrays, Wind Turbines, Batteries, Converters, Grid costs/usage, Solar resources, Wind resources, Temperatures, Fuels, and Electric Loads. HOMER's optimization and sensitivity analysis algorithms then evaluate the economic and technical feasibility of these technology options and account for variations in technology costs, electric load, and energy resource availability. The Navy can then use HOMER’s optimization and sensitivity results to compare to those of the SIREN model. The U.S. Department of Energy (DOE) Idaho National Laboratory (INL) possesses unique expertise and experience in the software, hardware, and systems design for the integration of renewable energy into the electrical grid. NAVFAC EXWC will draw upon this expertise to complete mission requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Novel Crab Cavity RF Design – Phase 1

The design and construction of electron-ion colliders, EIC, will be facilitated by the development of an SRF “crab crossing” cavity with 0.5 to 1.5 GHz frequency and 20 to 50 MV of total integrated voltage. The development of RF cavities that provide a transverse kick to the particle beam will include RF design, computer modeling, and hardware development. Current state of the art crab cavities provide 2- 5 MV of integrated voltage, and most of the existing designs require complex schemes to damp unwanted RF modes. We propose a novel design for TEM-like, room-temperature, two-bar structures, or hybrid structures with one resonant bar and one input coax per module, which can also be implemented for SRF conditions. Unwanted modes are coupled out of the cavity by the coax input line, and this provides a uniquely simple method to reduce the strength of higher-order modes. Critical phase stability for the crabbing voltage is provided by the low-level RF system, which controls the RF to the input ports of the novel crab cavity design. Designs for a series of cavities, or for multiple-module cavities, will provide the 20-50 MV of integrated voltage in an electron-ion collider, while meeting the critical thermal and mechanical requirements for heat loads, alignment, and phase stability. RF designs for various module alternatives were evaluated in Phase I. A single module of a hybrid design with one resonant bar and one coax input was built for room-temperature, low-power testing with a bead-pull measurement. Several additional designs were explored that made use of a high RT/Q, voltage-efficient, S-mode structure.

Neubauer, Michael↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Development of ARCHER towards clinical use: modeling and simulation of Varian Linac for radiation therapy dose calculations - 25449

Monte Carlo particle transport methods are well recognized as the most accurate approach to dose calculations for radiation therapy treatment planning. However, the lengthy calculation time has prevented Monte Carlo methods from being applied to dose calculations in the planning of radiation therapy. Recently, the emerging parallel computing hardware accelerators, such as general-purpose Graphics Processing Unit (GPU), have significantly boosted the performance of Monte Carlo codes. The accuracy of a clinical dose engine depends greatly on the accuracy of source term modeling and the methodology of dose calculations. Hence, in this study, an efficient and accurate source model of the Varian TrueBeam{sup R} Linac is developed and integrated with a fast photon-electron transport module of the recently developed high-performance Monte Carlo code, ARCHER. The validity of the source model and the particle transport physics are verified with established dose calculation codes such as EGSnrc and validated with experimental measurements. To demonstrate the capability of the platform in clinical applications, three clinical treatment plans (the lung, breast, and prostate) are simulated and analyzed. From the perspective of performance, the entire simulation of each clinical plan, starting from the source modeling to the end of particle transport within the patient phantom, can be finished in less than one minute using a single Titan X GPU card with 1% statistical error. In comparison, the same cases take the EGSnrc code hundreds of CPU hours to finish. The results suggest that this new version of ARCHER code has been successfully developed and tested as a clinically deployable dose engine for external photon beam IMRT plans in the clinical setting. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Observability of fidelity decay at the Lyapunov rate in few-qubit quantum simulations

In certain regimes, the fidelity of quantum states will decay at a rate set by the classical Lyapunov exponent. This serves both as one of the most important examples of the quantum-classical correspondence principle and as an accurate test for the presence of chaos. While detecting this phenomenon is one of the first useful calculations that noisy quantum computers without error correction can perform, a thorough study of the quantum sawtooth map reveals that observing the Lyapunov regime is just beyond the reach of present-day devices. We prove that there are three bounds on the ability of any device to observe the Lyapunov regime and give the first quantitatively accurate description of these bounds: (1) the Fermi golden rule decay rate must be larger than the Lyapunov rate, (2) the quantum dynamics must be diffusive rather than localized, and (3) the initial decay rate must be slow enough for Lyapunov decay to be observable. This last bound, which has not been recognized previously, places a limit on the maximum amount of noise that can be tolerated. The theory implies that an absolute minimum of 6 qubits is required. Recent experiments on IBM-Q and IonQ imply that some combination of a noise reduction by up to 100x per gate and large increases in connectivity and gate parallelization are also necessary. Finally, scaling arguments are given that quantify the ability of future devices to observe the Lyapunov regime based on trade-offs between hardware architecture and performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Medium Truck Duty Cycle Data from Real-World Driving Environments: Project Interim Report

Since the early part of the 20th century, the US trucking industry has provided a safe and economical means of moving commodities across the country. At the present time, nearly 80% of the US domestic freight movement involves the use of trucks. The US Department of Energy (DOE) is spearheading a number of research efforts to improve heavy vehicle fuel efficiencies. This includes research in engine technologies (including hybrid and fuel cell technologies), lightweight materials, advanced fuels, and parasitic loss reductions. In addition, DOE is developing advanced tools and models to support heavy vehicle truck research, and is leading the 21st Century Truck Partnership whose stretch goals involve a reduction by 50% of the fuel consumption of heavy vehicles on a ton-mile basis. This Medium Truck Duty Cycle (MTDC) Project is a critical element in DOE s vision for improved heavy vehicle energy efficiency and is unique in that there is no other national database of characteristic duty cycles for medium trucks. It involves the collection of real-world data for various situational characteristics (rural/urban, freeway/arterial, congested/free-flowing, good/bad weather, etc.) and looks at the unique nature of medium trucks drive cycles (stop-and-go delivery, power takeoff, idle time, short-radius trips), to provide a rich source of data that can contribute to the development of new tools for fuel efficiency and modeling, provide DOE a sound basis upon which to make technology investment decisions, and provide a national archive of real-world-based medium-truck operational data to support heavy vehicle energy efficiency research. The MTDC project involves a two-part field operational test (FOT). For the Part-1 FOT, three vehicles, each from two vocations (urban transit and dry-box delivery) were instrumented for one year of data collection. The Part-2 FOT will involve the towing/recovery and utility vocations. The vehicles participating in the MTDC project are doing so through gratis partnerships in return for early access to the results of this study. Partnerships such as these are critical to FOTs in which real-world data is being collected. In Part 1 of the project, Oak Ridge National Laboratory(ORNL) established partnerships with the H.T. Hackney Company, one of the largest wholesale distributors in the country, distributing products to 21 states; and with the Knoxville Area Transit (KAT), the City of Knoxville s transit system, operating services across the city of Knoxville and parts of Knox co. These partnerships and agreements provided ORNL access to three Class-7 2005/2007 International day-cab tractors, model 8600, which regularly haul 28 ft pup trailers (H.T. Hackney Co) and three Class-7 2005 Optima LF-34 buses (KAT), for collection of duty cycle data. In addition, ORNL has collaborated with the Federal Motor Carrier Safety Administration (FMCSA) to determine if there were possible synergies between this duty cycle data collection effort and FMCSA s need to learn more about the operation and duty cycles of the second-largest fuel consuming commercial vehicle category in the US. FMCSA s primary interest was in collecting safety data relative to the driver, carrier, and vehicle. In order to collect the duty cycle and safety-related data, ORNL developed a data acquisition and wireless communication system that was placed on each test vehicle. Each signal recorded in this FOT was collected by means of one of the instruments incorporated into each data acquisition system (DAS). Native signals were obtained directly from the vehicle s J1939 and J1708 data buses. A VBOX II Lite collected Global Positioning System related information including speed, acceleration, and spatial location information at a rate of 5 Hz, and communicated this data via the CAN (J1939) protocol. The Air-Weigh LoadMaxx, a self-weighing system which determines the vehicle s gross weight by means of pressure transducers and posts the weight to the vehicle s J1939 data bus, was used to collect vehicle payload information. A cellular modem, the Raven X EVDO V4221, facilitated the communication between the eDAQ-lite (the data collection engine of the system) and the user, via the internet. The modem functioned as a wireless gateway, allowing data retrievals and system checks to be performed remotely. Also, and in partnership with FMCSA, two additional safety sensors were installed on the combination vehicles: the MGM e-Stroke brake monitoring system and the Tire SafeGuard tire pressure monitoring system. Both of these systems posted data to the J1939 data bus, enabling these signals to be read without any additional DAS interface hardware. Seventy-three signals from the different deployed sensors and available vehicle systems were collected. Because of the differences in vehicle data buses (i.e., J1939 and J1708 data buses), not all desired signals were available for both types of vehicles.

duty cycles↗