Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

MAXIMUM LIKELIHOOD ANALYSIS OF SYSTEMATIC ERRORS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND

We investigate the impact of instrumental systematic errors in interferometric measurements of the cosmic microwave background (CMB) temperature and polarization power spectra. We simulate interferometric CMB observations to generate mock visibilities and estimate power spectra using the statistically optimal maximum likelihood technique. We define a quadratic error measure to determine allowable levels of systematic error that does not induce power spectrum errors beyond a given tolerance. As an example, in this study we focus on differential pointing errors. The effects of other systematics can be simulated by this pipeline in a straightforward manner. We find that, in order to accurately recover the underlying B-modes for r = 0.01 at 28 < l < 384, Gaussian-distributed pointing errors must be controlled to 0. Degree-Sign 7 root mean square for an interferometer with an antenna configuration similar to QUBIC, in agreement with analytical estimates. Only the statistical uncertainty for 28 < l < 88 would be changed at {approx}10% level. With the same instrumental configuration, we find that the pointing errors would slightly bias the 2{sigma} upper limit of the tensor-to-scalar ratio r by {approx}10%. We also show that the impact of pointing errors on the TB and EB measurements is negligibly small.

79 ASTRONOMY AND ASTROPHYSICS↗

CRADA Number NFE-21-08827 with DayLyte, Inc. (CRADA Final Report)

DayLyte Batteries is developing an aqueous Sodium-Air battery made with abundant materials while being half to a third the weight of Li-ion to power electric aircraft, electric vehicles and provide renewable energy on demand. To make this battery practical, DayLyte is developing a thin film ceramic Nasicon solid electrolyte amenable to rapid scaleup as well as a protective coating that will protect the solid electrolyte from 50wt% NaOH during the battery’s end-of-discharge while still allowing Na-ions to pass back and forth. If the thin film solid electrolyte and stable coating can be developed it will open the world to step change in battery performance all while not sacrificing the environment on the way. The project was designed to first focus on making and characterizing the Nasicon membrane followed by measuring its electrochemical performance, then assembling a full cell, optimizing its NaOH stability and then optimize the overall prototype design. Over the past two years, we have significantly improved the Nasicon film uniformity, demonstrated protective ligands that are stable in 50wt% NaOH by measuring no mass change with a quartz crystal microbalance, tested different heating methods like tube furnace and rapid heating and developed glassy carbon coatings on the current collector to prevent Nasicon-current collector alloying. We have found that getting film uniformity as measured by electrochemical impedance spectroscopy (EIS) is difficult because of different factors like surface roughness, deposition uniformity and heat treatment time and uniformity. The glassy carbon coating should significantly reduce the surface roughness and by tuning the coating conditions the film deposition uniformity improves and using an automated heating method should lead to much improved film uniformity.

25 ENERGY STORAGE↗

Improving stability margins in discrete-time LQG controllers

Some of the problems are discussed which are encountered in the design of discrete-time stochastic controllers for problems that may adequately be described by the Linear Quadratic Gaussian (LQG) assumptions; namely, the problems of obtaining acceptable relative stability, robustness, and disturbance rejection properties. A dynamic compensator is proposed to replace the optimal full state feedback regulator gains at steady state, provided that all states are measurable. The compensator increases the stability margins at the plant input, which may possibly be inadequate in practical applications. Though the optimal regulator has desirable properties the observer based controller as implemented with a Kalman filter, in a noisy environment, has inadequate stability margins. The proposed compensator is designed to match the return difference matrix at the plant input to that of the optimal regulator while maintaining the optimality of the state estimates as directed by the measurement noise characteristics.

Oranc, B. Tarik↗

Strategies to Save 50% Site Energy in Grocery and General Merchandise Stores

This paper summarizes the methodology and main results of two recently published Technical Support Documents. These reports explore the feasibility of designing general merchandise and grocery stores that use half the energy of a minimally code-compliant building, as measured on a whole-building basis. We used an optimization algorithm to trace out a minimum cost curve and identify designs thatsatisfy the 50% energy savings goal. We started from baseline building energy use and progressed to more energy-efficient designs by sequentially adding energy design measures (EDMs). Certain EDMs figured prominently in reaching the 50% energy savings goal for both building types: (1) reduced lighting power density; (2) optimized area fraction and construction of view glass or skylights, orboth, as part of a daylighting system tuned to 46.5 fc (500 lux); (3) reduced infiltration with a main entrance vestibule or an envelope air barrier, or both; and (4) energy recovery ventilators, especially in humid and cold climates. In grocery stores, the most effective EDM, which was chosen for all climates, was replacing baseline medium-temperature refrigerated cases with high-efficiencymodels that have doors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types

Purpose: To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers’ effective point of measurement (EPOM) and beam quality conversion factors. Methods: The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R{sub 50} converted from I{sub 50} (calculated using ion chamber simulations in phantom) to R{sub 50} calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. Results: For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, k{sub Q}, as a function of R{sub 50}. The optimal shift of cylindrical chambers is found to be less than the 0.5 r{sub cav} recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 r{sub cav}. Values of k{sub ecal} are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R{sub 50} = 7.5 cm (k{sub Q}{sup ′}) are provided. These factors avoid the use of gradient correction factors as used in the TG-51 protocol although a chamber dependent optimal shift in the EPOM is required when using plane-parallel chambers while no shift is needed with cylindrical chambers. The sensitivity of these results to parameters used to model the ion chambers is discussed and the uncertainty related to the practical use of these results is evaluated. Conclusions: These results will prove useful as electron beam reference dosimetry protocols are being updated. The analysis of this work indicates that cylindrical ion chambers may be appropriate for use in low-energy electron beams but measurements are required to characterize their use in these beams.

07 ISOTOPE AND RADIATION SOURCES↗

Electric and Conventional Vehicle Performance over Eco-Driving Cycles: Energy Benefits and Component Loss

Battery electric vehicles (BEVs) are expected to be a pathway towards meeting greenhouse and criteria pollutant gas reductions in the current and future transportation sector. However, BEV technologies are still evolving, including efficiency optimization and enhancement. Emerging connected and automated vehicle (CAV) technologies provide an in-depth insight for developing innovative applications and systems to leverage BEV energy efficiency and substantially transform transportation systems. Therefore, we present simulation studies of various BEV types and compare the performance between measured, real-world drive cycles and highly optimized eco-driving cycles that are representative of trajectory modifications using advanced CAV technologies. The investigated vehicles include a compact car and a Class 7 delivery truck. The results demonstrate that eco-driving has a high potential to reduce energy consumption for the BEVs considered. As part of the study, a comprehensive EV powertrain model was developed to account for key EV components and powertrain configurations. The impact of eco-driving was further evaluated for conventional vehicles with characteristics that are comparable to the modeled BEVs.

Gao, Zhiming↗

Electric and Conventional Vehicle Performance over Eco-Driving Cycles: Energy Benefits and Component Loss

Battery electric vehicles (BEVs) are expected to be a pathway towards meeting greenhouse and criteria pollutant gas reductions in the current and future transportation sector. However, BEV technologies are still evolving, including efficiency optimization and enhancement. Emerging connected and automated vehicle (CAV) technologies provide an in-depth insight for developing innovative applications and systems to leverage BEV energy efficiency and substantially transform transportation systems. Therefore, we present simulation studies of various BEV types and compare the performance between measured, real-world drive cycles and highly optimized eco-driving cycles that are representative of trajectory modifications using advanced CAV technologies. The investigated vehicles include a compact car and a Class 7 delivery truck. The results demonstrate that eco-driving has a high potential to reduce energy consumption for the BEVs considered. As part of the study, a comprehensive EV powertrain model was developed to account for key EV components and powertrain configurations. The impact of eco-driving was further evaluated for conventional vehicles with characteristics that are comparable to the modeled BEVs.

Gao, Zhiming↗

On-the-fly data assessment for high-throughput x-ray diffraction measurements

Investment in brighter sources and larger and faster detectors has accelerated the speed of data acquisition at national user facilities. The accelerated data acquisition offers many opportunities for the discovery of new materials, but it also presents a daunting challenge. The rate of data acquisition far exceeds the current speed of data quality assessment, resulting in less than optimal data and data coverage, which in extreme cases forces recollection of data. Herein, we show how this challenge can be addressed through the development of an approach that makes routine data assessment automatic and instantaneous. By extracting and visualizing customized attributes in real time, data quality and coverage, as well as other scientifically relevant information contained in large data sets, is highlighted. Deployment of such an approach not only improves the quality of data but also helps optimize the usage of expensive characterization resources by prioritizing measurements of the highest scientific impact. We anticipate our approach will become a starting point for a sophisticated decision-tree that optimizes data quality and maximizes scientific content in real time through automation. Finally, with these efforts to integrate more automation in data collection and analysis, we can truly take advantage of the accelerating speed of data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aircraft/island/ship/satellite intercomparison: Preliminary results from July 16, 1987

The First ISCCP Regional Experiment (FIRE) objective of validating and improving satellite algorithms for inferring cloud properties from satellite radiances was one of the central motivating factors in the design of the specific field experimental strategies used in the July, 1987 marine stratocumulus intensive field observations (IFO). The in situ measuring platforms were deployed to take maximum advantage of redundant measurements (for intercomparison of the in situ sensors) and to provide optimal coverage within satellite images. One of the most ambitious of these strategies was the attempt to coordinate measurements from San Nicolas Island (SNI), the R/V Pt. Sur, the meteorological aircraft, and the satellites. For the most part, this attempt was frustrated by flight restrictions in the vicinity of SNI. The exception was the mission of July 16, 1987, which achieved remarkable success in the coordination of the platforms. This presentation concerns operations conducted by the National Center for Atmospheric Research (NCAR) Electra and how data from the Electra can be integrated with and compared to data from the Pt. Sur, SNI, and the satellites. The focus is on the large-scale, integrated picture of the conditions on July 16 from the perspective of the Electra's flight operations.

Hanson, Howard P.↗

Non-Gaussianity in WMAP data due to the correlation of CMB lensing potential with secondary anisotropies

We measure the skewness power spectrum of the CMB anisotropies optimized for a detection of the secondary bispectrum generated by the correlation of the CMB lensing potential with integrated Sachs-Wolfe effect and the Sunyaev-Zel'dovich effect. The covariance of our measurements is generated by Monte Carlo simulations of Gaussian CMB fields with noise properties consistent with WMAP 5-year data. When interpreting multifrequency measurements we also take into account the confusion resulting from unresolved radio point sources. We analyze Q, V and W-band WMAP 5-year raw and foreground-cleaned maps using the KQ75 mask out to l{sub max}=600. We find no significant evidence for a nonzero non-Gaussian signal from the lensing-secondary correlation in all three bands and we constrain the overall amplitude of the cross-power spectrum between CMB lensing potential and the sum of SZ and ISW fluctuations to be 0.42{+-}0.86 and 1.19{+-}0.86 in combined V and W-band raw and foreground-cleaned maps provided by the WMAP team, respectively. The point-source amplitude at the bispectrum level measured with this skewness power spectrum is higher than previous measurements of point-source non-Gaussianity. We also consider an analysis where we also account for the primordial non-Gaussianity in addition to lensing-secondary bispectrum and point sources. The focus of this paper is on secondary anisotropies. Consequently the estimator is not optimized for primordial non-Gaussianity and the limit we find on local non-Gaussianity from the foreground-cleaned V+W maps is f{sub NL}=-13{+-}62, when marginalized over point sources and lensing-ISW/SZ contributions to the total bispectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibration mitigation in J-TEXT far-infrared diagnostic systems

Optical structure stability is an important issue for far-infrared (FIR) phase measurements. To ensure good signal quality, influence of vibration should be minimized. Mechanical amelioration and optical optimization can be taken in turn to decrease vibration's influence and ensure acceptable measurement. J-TEXT (Joint Texal Experiment Tokamak, formerly TEXT-U) has two FIR diagnostic systems: a HCN interferometer system for electron density measurement and a three-wave polarimeter-interferometer system (POLARIS) for electron density and Faraday effect measurements. All use phase detection techniques. HCN interferometer system has almost eliminated the influence of vibration after mechanical amelioration and optical optimization. POLARIS also obtained first experimental results after mechanical stability improvements and is expected to further reduce vibration's influence on Faraday angle to 0.1 Degree-Sign after optical optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

SU-D-BRC-01: An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy

Purpose: Monte Carlo (MC) simulation is typically regarded as the most accurate dose calculation method for proton therapy. Yet for real clinical cases, the overall accuracy also depends on that of the MC beam model. Commissioning a beam model to faithfully represent a real beam requires finely tuning a set of model parameters, which could be tedious given the large number of pencil beams to commmission. This abstract reports an automatic beam-model commissioning method for pencil-beam scanning proton therapy via an optimization approach. Methods: We modeled a real pencil beam with energy and spatial spread following Gaussian distributions. Mean energy, and energy and spatial spread are model parameters. To commission against a real beam, we first performed MC simulations to calculate dose distributions of a set of ideal (monoenergetic, zero-size) pencil beams. Dose distribution for a real pencil beam is hence linear superposition of doses for those ideal pencil beams with weights in the Gaussian form. We formulated the commissioning task as an optimization problem, such that the calculated central axis depth dose and lateral profiles at several depths match corresponding measurements. An iterative algorithm combining conjugate gradient method and parameter fitting was employed to solve the optimization problem. We validated our method in simulation studies. Results: We calculated dose distributions for three real pencil beams with nominal energies 83, 147 and 199 MeV using realistic beam parameters. These data were regarded as measurements and used for commission. After commissioning, average difference in energy and beam spread between determined values and ground truth were 4.6% and 0.2%. With the commissioned model, we recomputed dose. Mean dose differences from measurements were 0.64%, 0.20% and 0.25%. Conclusion: The developed automatic MC beam-model commissioning method for pencil-beam scanning proton therapy can determine beam model parameters with satisfactory accuracy.

60 APPLIED LIFE SCIENCES↗

X-Ray Detection and Processing Models for Spacecraft Navigation and Timing

The current primary method of deepspace navigation is the NASA Deep Space Network (DSN). High-performance navigation is achieved using Delta Differential One-Way Range techniques that utilize simultaneous observations from multiple DSN sites, and incorporate observations of quasars near the line-of-sight to a spacecraft in order to improve the range and angle measurement accuracies. Over the past four decades, x-ray astronomers have identified a number of xray pulsars with pulsed emissions having stabilities comparable to atomic clocks. The x-ray pulsar-based navigation and time determination (XNAV) system uses phase measurements from these sources to establish autonomously the position of the detector, and thus the spacecraft, relative to a known reference frame, much as the Global Positioning System (GPS) uses phase measurements from radio signals from several satellites to establish the position of the user relative to an Earth-centered fixed frame of reference. While a GPS receiver uses an antenna to detect the radio signals, XNAV uses a detector array to capture the individual xray photons from the x-ray pulsars. The navigation solution relies on detailed xray source models, signal processing, navigation and timing algorithms, and analytical tools that form the basis of an autonomous XNAV system. Through previous XNAV development efforts, some techniques have been established to utilize a pulsar pulse time-of-arrival (TOA) measurement to correct a position estimate. One well-studied approach, based upon Kalman filter methods, optimally adjusts a dynamic orbit propagation solution based upon the offset in measured and predicted pulse TOA. In this delta position estimator scheme, previously estimated values of spacecraft position and velocity are utilized from an onboard orbit propagator. Using these estimated values, the detected arrival times at the spacecraft of pulses from a pulsar are compared to the predicted arrival times defined by the pulsar s pulse timing model. A discrepancy provides an estimate of the spacecraft position offset, since an error in position will relate to the measured time offset of a pulse along the line of sight to the pulsar. XNAV researchers have been developing additional enhanced approaches to process the photon TOAs to arrive at an estimate of spacecraft position, including those using maximum-likelihood estimation, digital phase locked loops, and "single photon processing" schemes that utilize all available time data associated with each photon. Using pulsars from separate, non-coplanar locations provides range and range-rate measurements in each pulsar s direction. Combining these different pulsar measurements solves for offsets in position and velocity in three dimensions, and provides accurate overall navigation for deep space vehicles.

Sheikh, Suneel↗

Search for NuMI $\mu$DAR Electron Neutrinos in MicroBooNE

Muon Decay-at-Rest ($\mu$DAR) produces electron-neutrinos ($\nu_e$) in the $0$ to $53$ MeV energy range. The given range is especially interesting for its similarity to Supernovae-produced $\nu_e$. The Deep Underground Neutrino Experiment (DUNE) has as one of its main goals to measure Supernovae neutrinos on the occasion of a Galactic Supernova burst. To optimize the chances of detection, a low-energy neutrino-LAr cross-section (XS) measurement is a piece of important information to have at hand. MicroBooNE presents a good opportunity to explore the low-energy $\nu$-LAr detection and XS using the $\mu$DAR neutrinos and therefore develop the tools necessary for DUNE to in is a LArTPC that has been collecting neutrino data since October 2015 from the Booster Neutrino Beam (BNB) and off-axis to the Neutrinos at the Main Injector (NuMI) beam, both copious sources of $\mu$DAR neutrinos. esis, we present a first attempt to measure MeV-scale neutrinos in a LArTPC. To do that, we use specifi c MeV-scale reconstruction tools combined with other traditional reconstruction tools used in MicroBooNE. We discuss the tool's performance, limitations, and provide suggestions on how to improve them. zes looks for $\mu$DAR neutrino- argon charged current interactions in the NuMI Run1 data, that contains $2\times 10^{20}$ POT. We observed $9,176$ signal candidates. The number of expected background events is $8,776$, the majority from cosmic rays. We establish a XS upper limit of $<\sigma> = 1.99\times10^{-37} \textrm{cm}^2 / \textrm{Ar}$, which corresponds to $551.9$ times the nominal prediction from MARLEY, the neutrino generator used in this work. Despite the lack of sensitivity, this work is the first of its kind and sets the foundation for future similar analysis in the future. In the conclusions, we discuss how this results can be further improved in MicroBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗