Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Dynamic testing of a single-degree-of-freedom strapdown gyroscope

Test methods and results are presented for the equivalent average input rate of a single-degree-of-freedom gyroscope operated both open loop and with a ternary-logic pulse-torque-to-balance loop during multiaxis angular oscillation. For the open-loop tests, good agreement was obtained with theoretical results. Two-axis testing was performed for oscillations about the Input-Output axes, the Input-Spin axes, and the Spin-Output axes. These tests run in the torque-to-balance mode revealed significant departures from open-loop results in the induced drift rate. An analysis is developed explaining much of the closed-loop data presented. Test data for the gryoscope in a ternary torque-to-balance loop with constant input rates is presented. The tests demonstrate that the instrument rate linearity does not change with interrogation frequency from 3,600 to 14,400 Hz if the torque coil is tuned to offer a resistive load to the current switch. Analysis cited shows that gyroscope lag compensation eliminates multiple pulsing and other equivalent forms of degraded resolution in a wide variety of quantizing loops. This result is test verified for the ternary delta-modulator loop.

Lory, C. B.↗

Multi-level bandwidth efficient block modulation codes

The multilevel technique is investigated for combining block coding and modulation. There are four parts. In the first part, a formulation is presented for signal sets on which modulation codes are to be constructed. Distance measures on a signal set are defined and their properties are developed. In the second part, a general formulation is presented for multilevel modulation codes in terms of component codes with appropriate Euclidean distances. The distance properties, Euclidean weight distribution and linear structure of multilevel modulation codes are investigated. In the third part, several specific methods for constructing multilevel block modulation codes with interdependency among component codes are proposed. Given a multilevel block modulation code C with no interdependency among the binary component codes, the proposed methods give a multilevel block modulation code C which has the same rate as C, a minimum squared Euclidean distance not less than that of code C, a trellis diagram with the same number of states as that of C and a smaller number of nearest neighbor codewords than that of C. In the last part, error performance of block modulation codes is analyzed for an AWGN channel based on soft-decision maximum likelihood decoding. Error probabilities of some specific codes are evaluated based on their Euclidean weight distributions and simulation results.

Lin, Shu↗

Insitu Calibration of Quartz Crystal Microbalances

Computer models that predict the rate at which molecular contamination will deposit on optical surfaces typically use outgassing source terms, measured with quartz crystal microbalances, as a basis for the prediction. The American Society of Testing and Materials, Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials (Method E-1559), is probably the best know technique used by the aerospace community to measure the outgassing rates or source terms of materials. A simple method for the insitu calibration of quartz crystal microbalances, based on the heat of enthalphy of Adipic Acid, has been developed and demonstrated by the Marshall Space Flight Center, Environmental Effects Group. The calibration has been demonstrated over a sample temperature range of 25 to 66 degrees Celsius and deposition rates of 7 x 10 (exp -11) grams/cm(sup 2)-s and greater, for several measurement system configurations. This calibration technique is fully compatible with the American Society for Testing and Materials, Method E-1559, as well as other methodology. The calibration requires no modification of outgassing facilities employing an effusion cell and does not degrade the performance or function of typical vacuum systems.

Albyn, Keith↗

Indirect M-MRAC for Systems with Time Varying Parameters and Bounded Disturbances

The paper presents a prediction-identification model based adaptive control method for uncertain systems with time varying parameters in the presence of bounded external disturbances. The method guarantees desired tracking performance for the system s state and input signals. This is achieved by feeding back the state prediction error to the identification model. It is shown that the desired closed-loop properties are obtained with fast adaptation when the error feedback gain is selected proportional to the square root of the adaptation rate. The theoretical findings are confirmed via a simulation example.

Stepanyan, Vahram↗

The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER)

NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into intercepting heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a representative test tank is currently being designed to include skirt structural systems with integral vapor cooling. The tank is 4 m in diameter and 6.8 m tall to contain 5000 kg of liquid hydrogen. A multilayer insulation system will be designed to insulate the tank and structure while being installed in a representative manner that can be extended to tanks up to 10 meters in diameter. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plumbrook Station both before and after being vibration tested at Plumbrooks Space Power Facility.

Cryogenic Fluid Management↗

Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Abstract: NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into using boil-off to intercept heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a 4 meter diameter test tank and assembly is currently being designed to include skirt structural systems with integral vapor cooling. In order to give a more representative result for actual applications, the technologies will be designed for an 8.4 m and scaled down to a 4 meter tank. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plum Brook Station both before and after being vibration tested at Plum Brooks Space Power Facility.

Johnson, Wesley↗

Investigating Abrasion Effects of Lunar Simulant Grain Sizes on Candidate Spacesuit Fabric

Lunar dust is identified as one of the most significant challenges during the Apollo exploration missions due to its extremely abrasive and electrostatic characteristics. As NASA and the space industry prepare for the upcoming Artemis missions, researching and testing with lunar simulant is quintessential to understanding the effects of lunar dust on the systems and equipment that will be deployed on the lunar surface. Testing will also provide paths that lead to developing technologies and cleaning tools that could be used for dust mitigation. Additionally, it is expected that any hardware that will be exposed to the dusty environment should undergo rigorous testing to ensure it will maintain long-term performance and operate on the lunar surface. For this study, exterior spacesuit fabric was observed. Abrasion is one of the main concerns of lunar dust exposure for spacesuit fabric. Three different abrasion methods were chosen: a rotary tumbler, the Martindale method, and Accelerotor. These abrasion methods were tested on coated and uncoated spacesuit material, Orthofabric, to understand the abrasion rates of sieved lunar simulant and investigate if the addition of ceramic coating mitigated dust abrasion. To summarize, the testing results provided that larger grains are more abrasive than smaller grains, and the selected ceramic coatings did not minimize abrasion during the controlled abrasion tests. It is important to note that the selected ceramic coatings were not designed or intended to provide protection from the abrasive lunar environment. It is recommended to select additional ceramic coatings with an elevated TRL of 5 or greater for testing with Orthofabric and lunar simulant. As an additional note, contact angle measurements were not accounted for in coating selection and should be a factor when selecting adhesion resistant coatings for lunar dust.

grain size↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fatigue Life of Flow-Formed Aluminum 2195 and 6061 Alloys

The successful design and fabrication of metallic cryotanks for commercial aviation applications require lightweight, durable materials capable of withstanding high pressures and cryogenic temperatures through tens of thousands of thermomechanical refueling cycles. Flow forming is an advanced manufacturing technique that offers high-rate production and scalability for fabricating integrally stiffened cylinders suitable for cryotank applications. This work establishes the durability of flow-formed aluminum alloys by characterizing their fatigue life performance under conditions that mimic cryotank refueling cycles. Residual stresses in flow-formed aluminum-lithium (Al-Li) 2195-T6 cylinders were assessed using the contour method and found to be minimal. Fatigue life testing was conducted on flow-formed Al-Li 2195-T6 at room temperature and cryogenic temperatures (-321°F [-196°C]), with wrought Al-Li 2195-T6 serving as a baseline for comparison. Results showed that flow-formed materials exhibited fatigue performance comparable to or better than wrought materials, with no statistically significant differences observed between different specimen orientations relative to processing directions. Fractography revealed reduced delaminations in the flow-formed Al-Li 2195 samples as compared to wrought, indicating potential improvement to the microstructure that could result in improved service properties. Texture analysis using electron backscattered diffraction (EBSD) indicated recrystallization during heat treatment, potentially contributing to reduced delamination susceptibility. These findings demonstrating flow-formed material durability coupled with the high manufacturing efficiency of flow forming, makes flow forming an attractive process to produce aircraft cryotanks.

EBF3↗

Summary: Verification of the ENDF/B-VII.1 and VIII.0 AMPX 1597-group Libraries for Advanced Reactor Analysis

The SCALE/AMPX multigroup (MG) cross section processing procedure has been updated to minimize reactivity differences for various advanced thermal and fast reactor designs, as observed for the current MG libraries, resulting in excellent agreement between the calculations with the new MG libraries and the continuous-energy reference calculations. The SCALE MG calculations are widely applied to thermal spectrum light-water reactor systems, as well as fast spectrum metallic systems. Due to growing interest from industry and regulators in applying SCALE for the design of fast spectrum reactors—both sodium and molten salt—it was desirable to review and improve the SCALE/AMPX procedure for unresolved resonance self-shielded data and high-energy neutron spectra. The data were improved by generating MG unresolved resonance data based on the analytic probability table method with the narrow resonance approximation and by using very fine and intermediate group structures that are typical for fast system analysis. This study focused on verifying the improved SCALE/AMPX MG cross section processing procedure and the new AMPX 1597-group library with the ENDF/B-VII.1 and VIII.0 evaluated nuclear data. The verification was made by performing reaction rate analysis and benchmark calculations for various thermal and fast reactor systems. Results indicate that the improved SCALE/AMPX MG cross section processing and libraries provide excellent results for advanced reactor analysis.

Kim, Kang Seog↗

Verification of the ENDF/B-VII.1 and VIII.0 AMPX 1597-Group Libraries for Advanced Reactor Analysis

The SCALE/AMPX multigroup (MG) cross section processing procedure has been updated to minimize reactivity differences for various advanced thermal and fast reactor designs, as observed for the current MG libraries, resulting in excellent agreement between the calculations with the new MG libraries and the continuous-energy reference calculations. The SCALE MG calculations are widely applied to thermal spectrum light-water reactor systems, as well as fast spectrum metallic systems. Due to growing interest from industry and regulators in applying SCALE for the design of fast spectrum reactors—both sodium and molten salt—it was desirable to review and improve the SCALE/AMPX procedure for unresolved resonance self-shielded data and high-energy neutron spectra. The data were improved by generating MG unresolved resonance data based on the analytic probability table method with the narrow resonance approximation and by using very fine and intermediate group structures that are typical for fast system analysis. This study focused on verifying the improved SCALE/AMPX MG cross section processing procedure and the new AMPX 1597-group library with the ENDF/B-VII.1 and VIII.0 evaluated nuclear data. The verification was made by performing reaction rate analysis and benchmark calculations for various thermal and fast reactor systems. Results indicate that the improved SCALE/AMPX MG cross section processing and libraries provide excellent results for advanced reactor analysis.

Kim, Kang Seog↗

IMPROVING INTERMEDIATE TEMPERATURE PERFORMANCE OF NI-YSZ CERMET ANODES FOR SOLID OXIDE FUEL CELLS BY INFILTRATION OF NICKEL NANOPARTICLES AND MIXED IONIC ELECTRONIC CONDUCTOR

Solid oxide fuel cells (SOFCs) are one of the most efficient and environment-friendly devices for electricity generation. One critical challenge of SOFC commercialization is high cell operating temperatures (800°C-1000°C), which lead to high material costs, high performance degradation rates, long start-up and shutdown times, and limited portable applications. Intermediate temperature (600°C-800°C) operation of SOFCs is limited by sluggish electrode reaction kinetics. The objective of this research is to improve intermediate temperature performance of commercially available Ni-YSZ cermet anode supported SOFCs by liquid infiltration of the anode. One effective method to improve kinetics of electrochemical reactions at the anode is to increase the density of reaction sites, which are known as the triple phase boundaries (TPBs). The porous Ni-YSZ cermet anodes were liquid infiltrated with Ni nanoparticles, leading to a four-fold increase in TPB density in the anode. The improved electrochemical performance of the infiltrated cells compared to the uninfiltrated cells highlights the effectiveness of anode infiltration in facilitating improved anode electrochemical reaction kinetics. However, the post-electrochemical testing characterization revealed that Ni nanoparticles were not stable due to Ni coarsening and were mostly isolated indicating that not all of the additional TPBs were fully utilized in electrochemical reactions due to the lack of an electronic pathway between the Ni nanoparticles. In order to improve microstructural stability of the infiltrated Ni nanoparticles, and to fully utilize the added TPBs, co-infiltration of Ni with a mixed ionic and electronic conductor (MIEC) was carried out. Two MIEC materials are chosen based on their chemical stability and conductivity in the anode operating environments; Gd 0.1 Ce 0.9 O 2-δ (GDC), a predominantly an ionic conductor, and La 0.6 Sr 0.3 Ni 0.15 Cr 0.85 O 3-δ (LSNC), a predominantly electronic conductor, and cells were successfully co-infiltrated to form Ni-GDC and Ni-LSNC nanostructures with the MIEC phases connecting the Ni nanoparticles. Stability tests demonstrated that both MIECs inhibited Ni nanoparticle coarsening. Electrochemical studies showed that Ni-GDC is the most effective for improved anode kinetics. A long-term (120 hours) electrochemical test indicated that infiltration of Ni-GDC into Ni-YSZ cermet anode effectively improves overall cell performance at intermediate temperatures and maintains the performance gain for a long period of time.

Lu, Yanchen↗

Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator

Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2 at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.

30 DIRECT ENERGY CONVERSION↗

A high-fidelity method to analyze perturbation evolution in turbulent flows

Small perturbation propagation in fluid flows is usually examined by linearizing the governing equations about a steady basic state. It is often useful, however, to study perturbation evolution in the unsteady evolving turbulent environment. Such analyses can elucidate the role of perturbations in the generation of coherent structures or the production of noise from jet turbulence. The appropriate equations are still the linearized Navier–Stokes equations, except that the linearization must be performed about the instantaneous evolving turbulent state, which forms the coefficients of the linearized equations. This is a far more difficult problem since in addition to the turbulent state, its rate of change and the perturbation field are all required at each instant. In this paper, we develop and use a novel technique for this problem by using a pair (denoted “baseline” and “twin”) of simultaneous synchronized Large-Eddy Simulations (LES). At each time-step, small disturbances whose propagation characteristics are to be studied, are introduced into the twin through a forcing term. At subsequent time steps, the difference between the two simulations is shown to be equivalent to solving the forced Navier–Stokes equations, linearized about the instantaneous turbulent state. The technique does not put constraints on the forcing, which could be arbitrary, e.g., white noise or other stochastic variants. We consider, however, “native” forcing having properties of disturbances that exist naturally in the turbulent environment. The method then isolates the effect of turbulence in a particular region on the rest of the field, which is useful in the study of noise source localization. The synchronized technique is relatively simple to implement into existing codes. In addition to minimizing the storage and retrieval of large time-varying datasets, it avoids the need to explicitly linearize the governing equations, which can be a very complicated task for viscous terms or turbulence closures. The method is illustrated by application to a well-validated Mach 1.3 jet. Specifically, the effects of turbulence on the jet lipline and core collapse regions on the near-acoustic field are isolated. The properties of the method, including linearity and effect of initial transients, are discussed. The results provide insight into how turbulence from different parts of the jet contribute to the observed dominance of low and high frequency content at shallow and sideline angles, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IMRT QA: Selecting gamma criteria based on error detection sensitivity

Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. Conclusions: We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

Diagnostic performance of MRI- versus MDCT-categorized T3cd/T4 for identifying high-risk stage II or stage III colon cancers: a pilot study

Purpose: The aim of this study was to determine the diagnostic performance of magnetic resonance imaging (MRI)-categorized T3cd/T4 tumors for identifying high-risk stage II or stage III cancer in patients with curatively resectable colon cancer in comparison to that of multidetector computed tomography (MDCT). Materials and Methods: Thirty-eight patients with histopathologically indicated adenocarcinomas prospectively underwent MRI of the colon. Two radiologists independently and retrospectively assessed for T-category, including T3 substage (≤ T3ab vs. ≥ T3cd). The diagnostic accuracies and interreader agreements between assessments using each modality were compared using a pairwise comparison of receiver-operating characteristic curves and a weighted κ statistic, respectively. Results: Twenty-nine patients (76.3%) were histopathologically diagnosed with high-risk stage II or stage III colon cancer. The false-positive rate with MRI was lower than that with MDCT (0% vs. 7.9% for reader 1, 2.6% vs. 10.6% for reader 2). The diagnostic performance of MRI was better than that of MDCT across both readers (AUC: 0.707 vs. 0.506 [P = 0.032] for reader 1, 0.651 vs. 0.485 [P = 0.055] for reader 2). Moreover, MRI interreader agreement for the assessment of T3cd/T4 was significantly better than that of MDCT (κ = 0.821 vs. 0.391 [P = 0.017]). Conclusion: The diagnostic performance of MR imaging of the colon may be better than that of MDCT for identifying high-risk stage II or stage III cases. Particularly, colon MRI reduced the false-positive rate and improved the interreader agreement, although further studies with a larger sample size are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Annealing of ion tracks in apatite under pressure characterized in situ by small angle x-ray scattering

Fission track thermochronology is routinely used to investigate the thermal history of sedimentary basins, as well as tectonic uplift and denudation rates. While the effect of temperature on fission track annealing has been studied extensively to calibrate the application of the technique, the effect of pressure during annealing is generally considered to be negligible. However, a previous study suggested elevated pressure results in a significantly different annealing behaviour that was previously unknown. Here, we present a method to study track annealing in situ under high pressure by using synchrotron- based small angle x-ray scattering (SAXS). To simulate fission tracks in a controlled environment, ion tracks were created in apatite from Durango, Mexico using 2 GeV Au or Bi ions provided by an ion accelerator facility. Samples were annealed at 250°C at approximately 1 GPa pressure using diamond anvil cells (DAcs) with heating capabilities. Additional in situ annealing experiments at ambient pressure and temperatures between 320 and 390°C were performed for comparison. At elevated pressure a significantly accelerated annealing rate of the tracks was observed compared with annealing at ambient pressure. However, when extrapolated to geologically relevant temperatures and pressures, the effects become very small. The measurement methodology presented provides a new avenue to study materials behaviour in extreme environments.

58 GEOSCIENCES↗