Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physical Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Municipal and Commercial Equipment for Radiological Response and Recovery in an Urban Environment: State of Science, Research Needs, and Evaluation of Implementation Towards Critical Infrastructure Resilience

This report provides a thorough evaluation of technologies and equipment assets that may be effective at mitigating the effects of a wide-area radioactive contamination event and to restore critical functions to the urban environment. Moreover, equipment that could facilitate decontamination efforts during a recovery phase are evaluated. The summary of methods has been critically evaluated in terms of equipment availability, potential advantages and limitations, and research needs in order to justify and predict its efficacy. By ranking the host of techniques, a concise list of those technologies is provided that might be most impactful to a response and recovery effort and how to direct future effort. The totality of this effort and future work anticipates providing early responders and stakeholders with practical guidance information to expedite an effective response and recovery effort and mitigate the potentially devastating effects of a wide-area radioactive contamination event.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

MagMicro with Ultra-High Energy Resolution (Progress Report Q4 FY18)

We are performing extensive simulations of the MMC detector response to optimize their energy resolution, detection efficiency and count rate based on the data we took in FY17/18. The optimized layout separates the MMC detector chip from the SQUID preamplifier chips coupled to the MMCs through Al wire bonds to avoid heating the MMC with the power dissipation of the SQUID. The goal is to design MMC gamma detectors with a limiting energy resolution below ~25 eV FWHM up to >100 keV and ~1 ms decay times for maximum count rates of several tens of counts/s per pixel. The simulations, which were done at the Supercomputing Center of the University of New Mexico, are taking significantly longer than expected. The difficulty is that the device performance depends intricately on the design parameters, and each simulation is quite involved because it needs to cover the frequency range well into the GHz range to account for the ac Josephson effect. This is delaying the start of the detector array fabrication, and we have not been able to complete the fabrication and the testing of the 32-pixel MMC arrays by September 30. We have therefore requested a no-cost extension of the project to March 31, 2019.

42 ENGINEERING↗

Eyes On the Ground (Final Report)

This report summarizes the work performed under the Sandia LDRD project "Eyes on the Ground: Visual Verification for On-Site Inspection." The goal of the project was to develop methods and tools to assist an IAEA inspector in assessing visual and other information encountered during an inspection. Effective IAEA inspections are key to verifying states' compliance with nuclear non-proliferation treaties. In the course of this work we developed a taxonomy of candidate inspector assistance tasks, selected key tasks to focus on, identified hardware and software solution approaches, and made progress in implementing them. In particular, we demonstrated the use of multiple types of 3-d scanning technology applied to simulated inspection environments, and implemented a preliminary prototype of a novel inspector assistance tool. This report summarizes the project's major accomplishments, and gathers the abstracts and references for the publication and reports that were prepared as part of this work. We then describe work in progress that is not yet ready for publication. Approved for public release; further dissemination unlimited.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Radiological and WMD Threat Posed to National Security By Hezbollah in Latin America

Beginning in the 1980s, Hezbollah and other international terrorist organizations took root in unstable portions of Latin America. Over the years, they have built up considerable capabilities that threaten US national security and the security of allies in the region. However, Hezbollah has separated itself from its counterparts through its actions in Latin America, namely the Israeli Embassy and AMIA bombings in the early 1990s, and continues to do so. While it mainly operates out of the Tri-Border Area (TBA) of Paraguay, Brazil, and Argentina in South America, Hezbollah commands cells that span the Western Hemisphere. In the modern-day, Hezbollah conducts drug, weapons, and contraband trafficking and smuggling operations, in addition to its violent attacks. New revelations, involving the increased trafficking and stealing of nuclear and WMD material, populate the world’s nonproliferation roundtables. Latin America is no exception to this trend. It is possible that terrorist organizations, such as Hezbollah, could acquire, develop, and use stolen or illegally obtained nuclear material in a radiological dispersal device (RDD) or some form of WMD. In light of these revelations, the United States should focus more on Hezbollah’s illicit activities in Latin America in the interests of its own national security and its allies’.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Simulation-based Design of a Shadow Shield for the MIND Backpack System

Modeling and simulation is a cost- and time-saving method to study conceptual designs of radiation detection systems. MCNP radiation transport code has been an indispensable tool in development of radiation detection systems, and the PINS systems have also utilized MCNP modeling and simulation in the system development. MCNP models of the PINS systems have been used to understand detector responses and to fill the gap in experimental data. Recently, the MIND backpack system was announced to be developed, and its prototype design was required to conduct laboratory tests and demonstrations. A shadow shield is the component to be designed by Idaho National Laboratory in order to maximize the performance of a backpack system while meeting the sponsor’s requirements. MCNP modeling and simulation was utilized to find the best specification of a shadow shield. This study was performed to down-select a shadow shield design for the MIND system. A total of 24 designs for a shadow shield were identified to build MCNP models, and their simulation results were used to prioritize each design. As a quantitative performance metric, an equation of Figure-of-Merit was introduced in the decision making analysis. In addition, the Analytic Hierarchy Process was adopted to prioritize and recommend best performing shadow shield designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MagMicro with Ultra-High Energy Resolution (Report Q1 FY19)

Progress report provides update on these tasks: Task 15 Fabricate 32-pixel Ag:Er MMC Arrays, Task 16 Demonstrate energy resolution <50 eV FWHM, Task 17 Integrate Compton Veto with MMC in Dilution Refrigerator, Task 18 Operate 32-MMC array in LLNL dilution refrigerator, Task 19 Acquire Gamma Spectrum from Safeguards-Relevant Sample, and Task 20 Present paper at INMM and report to NA-22.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MagMicro with Ultra-High Energy Resolution (Q2 FY19)

Quarterly progress on six tasks: Task 15 Fabricate 32-pixel Ag:166Er MMC Arrays, Task 16 Demonstrate energy resolution <50 eV FWHM, Task 17 (Integrate Compton Veto with MMC in Dilution Refrigerator, Task 18 Operate 32-MMC array in LLNL dilution refrigerator, Task 19 (Acquire Gamma Spectrum from Safeguards-Relevant Sample, and Task 20 Present paper at INMM and report to NA-22.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

"Compete, Deter, and Win" in a Trans-Regional Perspective: On Meeting the New Challenges of Extended Deterrence

On February 26-27, the Center for Global Security Research (CGSR) at Lawrence Livermore National Laboratory (LLNL) hosted a workshop to examine extended deterrence in a transregional perspective the challenges of the “compete, deter, and win” strategy set out in the U.S. National Defense Strategy. This was the Center’s third annual workshop on extended deterrence. This session brought together participants drawn across the policy, military, and technical communities. Among the 65 participants, 10 were from allied countries in Europe and 12 from allied countries in the Asia-Pacific region.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Annotated Bibliography: "U.S.-Russian Nuclear Arms Control: Crisis and Collapse or Crossroads?"

Key questions posed for the workshop: 1. Is there an opportunity to renew the bilateral arms control framework in a manner acceptable to both sides and supporting mutually beneficial objectives? If not at present, can one be created? How? 2. What, if anything, does President Putin want out of a re-constructed arms control approach? 3. What new agreements or processes would serve the interests of the United States and its allies and partners? 4. What might be the benefits and risks of a new U.S. proposal for a follow-on to New START? 5. What if traditional arms control collapses? Are there any less formal, other approaches to achieve U.S. objectives? Russian objectives? Center for Global Security Research is hosting eight panels over two days at Lawrence Livermore National Laboratory. The list of readings included provides some overview and background for the topics covered in the workshop. While some references are to books or materials not available online, where possible references include links to accessible versions of articles.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advanced Simulation and Computing FY20 Implementation Plan (Rev. 0)

The Stockpile Stewardship Program (SSP) is an integrated technical program for maintaining the safety, surety, and reliability of the U.S. nuclear stockpile. The SSP incorporates nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. The suite of data analyzed comes from activities including stockpile surveillance, experimental research, and development and engineering programs. This integrated national program requires the continued use of experimental facilities and the computational capabilities to support the SSP missions. These component parts, in addition to an appropriately scaled production capability, enable the National Nuclear Security Administration (NNSA) to support stockpile requirements. The ultimate goal of the Stewardship Program, and thus the Advanced Simulation and Computing (ASC) Program, is to ensure that the U.S. maintains a safe, secure, and effective strategic deterrent.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

MagMicro with Ultra-High Energy Resolution (FY19 Q3 Progress Report)

The fabrication of the MMC detector arrays involves two photolithographic procedures. The first is to fabricate the Nb magnetization coil and pick-up coils, the SQUID preamplifiers and the associated wiring. This is done on a full 4” Si wafer, which is subsequently diced into ~0.5 cm2 SQUID chips and ~1 cm2 detector chips. The detector chips are then processed separately by depositing and patterning the paramagnetic Ag:Er sensor and support structures and then electroplating the Au absorber. In Q3, we have successfully completed the full wafer processing for the 32-pixel MMC detector arrays, diced the 4” wafer into the smaller chips and tested the individual components. The coils have the required critical current, the heat switches have a critical temperature in the desired range, and the SQUIDs have the required low noise. Unfortunately, the sputter deposition of the paramagnetic Ag:Er sensor failed several times. We spent considerable time to trace the problem to contaminations of the purifier for the Ar sputtering gas that had been exposed to atmosphere for an extended time during an earlier clean room upgrade. We then determined that the purifier is not essential for high-quality Ag:Er sensor films (Fig. 1), and successfully deposited the Ag:Er sensor film on the ~1 cm 2 detector chip.

42 ENGINEERING↗