Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Early Radiometric Performance of Landsat-9 Thermal Infrared Sensor

Landsat-9, launched on September 27, 2021, carries the Thermal Infrared Sensor (TIRS). The Landsat-9 TIRS is a close copy of the Landsat-8 TIRS instrument; it is a two spectral-band, pushbroom sensor with three Sensor Chip Assemblies (SCAs) that cover the 15-degree field-of-view. The primary radiometric change between the instruments is the addition of baffling in the Landsat-9 TIRS telescope to mitigate the stray light issue that has impacted the radiometric quality of Landsat-8 TIRS. The on-orbit radiometric performance is monitored using the on-board variable temperature blackbody and views of deep space. Maneuvers to look at and around the moon have provided an assessment of the stray light. The absolute calibration is monitored by vicarious calibration techniques by teams at NASA/Jet Propulsion Lab and the Rochester Institute of Technology. Landsat-9 completed a three-month commissioning phase in January 2022 and has been operational since February 2022. The instrument has demonstrated excellent radiometric performance, as assessed from the on-orbit measurements. The TIRS instrument is radiometrically stable to 0.1% within a power cycle, and has noise levels below 0.1K. The lunar scans and the vicarious calibration data provide evidence that the stray light has been effectively mitigated.

Landsat-9↗

The Global L-Band Observatory for Water Cycle Studies (Glows)– SMAP continuity Mission

SMOS and SMAP radiometers have demonstrated the ability to monitor soil moisture and sea surface salinity and continue to provide high quality radiometric measurements to this day in extended mission operations. It is important to maintain data continuity for these science measurements. The proposed instrument concept (Global L-band active/passive Observatory for Water cycle Studies - GLOWS) will enable low-cost L-band data continuity (that includes both L-band radar and radiometer measurements). The objective of this project is to develop key instrument technology to enable L-band observations using an Earth Venture class satellite. Specifically, a new deployable reflectarray lens antenna is being developed that will enable a smaller EELV Secondary Payload Adapter (ESPA) Grande-class satellite mission to continue the L-band observations at SMAP and SMOS resolution and accuracy at substantially lower cost, size, and weight

SMAP↗

Count Every Trip: Finding the Uncertainty in Energy Estimates Made from Inferred Travel Modes

To properly inform transport policy and infrastructure changes, transportation related metrics need both measured values and uncertainties of those values. Travel monitoring smartphone apps can record people's travel behavior, but trip data quality is limited by sensor errors, user labeling rates and the accuracy of inference algorithms used for travel diary creation. We discuss the use of phone app recorded travel diary data to estimate energy consumption, and propose the use of propagation of variance to find error bars for such estimates. We define energy consumption for one trip as trip length times the energy intensity per distance unit of the travel mode used. We characterize trip length errors with relative error and inferred trip mode errors with confusion matrix columns. The resulting variances of each measurement are then propagated to the final calculated energy consumption. We tested our uncertainty methods on a dataset that used phone app data combined with prompted recall, consisting of 92,234 labeled trips for over 500,000 miles. Accounting for uncertainty using expected energy intensities and variance propagation gives a dataset-wide aggregate energy consumption percent error of about 9%, within one standard deviation from the truth. Future work could involve applying similar methods to other travel diary based metrics.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

Count Every Trip: Finding the Uncertainty in Energy Estimates Made from Inferred Travel Modes

To properly inform transport policy and infrastructure changes, transportation related metrics need both measured values and uncertainties of those values. Travel monitoring smartphone apps can record people's travel behavior, but trip data quality is limited by sensor errors, user labeling rates and the accuracy of inference algorithms used for travel diary creation. We discuss the use of phone app recorded travel diary data to estimate energy consumption, and propose the use of propagation of variance to find error bars for such estimates. We define energy consumption for one trip as trip length times the energy intensity per distance unit of the travel mode used. We characterize trip length errors with relative error and inferred trip mode errors with confusion matrix columns. The resulting variances of each measurement are then propagated to the final calculated energy consumption. We tested our uncertainty methods on a dataset that used phone app data combined with prompted recall, consisting of 92,234 labeled trips for over 500,000 miles. Accounting for uncertainty using expected energy intensities and variance propagation gives a dataset-wide aggregate energy consumption percent error of about 9%, within one standard deviation from the truth. Future work could involve applying similar methods to other travel diary based metrics.

ADVANCED PROPULSION SYSTEMS↗

Estimating Travel Energy Consumption Uncertainty Based on Inferred Travel Mode and Sensed Travel Length

To properly inform transport policy and infrastructure changes, transportation related metrics need both measured values and uncertainties of those values. Travel monitoring smartphone apps can record people's travel behavior, but trip data quality is limited by sensor errors, user labeling rates and the accuracy of inference algorithms used for travel diary creation. We discuss the use of phone app recorded travel diary data to estimate energy consumption, and propose the use of propagation of variance to find error bars for such estimates. We define energy consumption for one trip as trip length times the energy intensity per distance unit of the travel mode used. We characterize trip length errors with relative error and inferred trip mode errors with confusion matrix columns. The resulting variances of each measurement are then propagated to the final calculated energy consumption. We tested our uncertainty methods on a dataset that used phone app data combined with prompted recall, consisting of 92,234 labeled trips for over 500,000 miles. Accounting for uncertainty using expected energy intensities and variance propagation gives a dataset-wide aggregate energy consumption percent error of about 8%, within one standard deviation from the truth. Future work could involve applying similar methods to other travel diary based metrics.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116

An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated system as an alternative to traditional sample collection and analysis includes the following: - Field observations that provide more characterization information than is possible using traditional monitoring methods. - Potentially significant reductions in labor and analytical costs if traditional methods are complemented by automated systems. - The reduced cost of acquiring samples will allow for more frequent collection of samples that may be automatically introduced into real-time graphical flux programs allowing site managers to observe the changes in contaminant concentrations during remediation projects and across discrete river stage events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-Term Stewardship Optimization for a Decommissioned Nuclear Reactor - 19579

The decommissioned Hallam Nuclear Power Facility (Hallam), located in Lancaster County, Nebraska, approximately 19 miles south of Lincoln, was developed as a prototype to investigate the technical and economic feasibility of a sodium-cooled, graphite-moderated nuclear reactor. As part of its Power Demonstration Program, the US Atomic Energy Commission (US AEC), a predecessor agency of the US Department of Energy (US DOE), operated the Hallam reactor from 1962 to 1964. The radiological surveillance of the Hallam site was established when the operating agreement between AEC and the Nebraska Public Power District was terminated. The US DOE Chicago Operations Office and the Nebraska Department of Health (NDH) agreed to install a shallow groundwater monitoring system as part of the environmental surveillance program. Surveillance at the site was scheduled to end in fiscal year 2005, with no further activities planned after that. At that time, the plan was to transition the site to the Nebraska Public Power District with future use of the facility to remain restricted. US DOE has title to and responsibility for the entombed radioactive materials. A surveillance and monitoring program was initiated in 1970 by NDH and was funded by US AEC. It included the analysis of samples from deep production wells (groundwater from the regional aquifer at depths greater than 55 meters [180 feet]) at the Sheldon Station. NDH was concerned in 1990 about the possibility of shallow groundwater coming in contact with the buried radiological materials along the buried walls of the reactor. Subsequently, DOE and NDH agreed to further characterize hydrologic conditions and establish a monitoring program in the shallow, perched groundwater zones. The current monitoring program focuses on the shallow, perched groundwater. Today, decades since facility decommissioning, site inspections and groundwater monitoring continue at this Cold War-era legacy site. The US DOE Office of Legacy Management (LM) monitors groundwater as a best management practice in response to a request from the Nebraska Department of Health and Human Services (DHHS). In 2006, LM recommended discontinuing groundwater monitoring because analytical results since 1970 demonstrated there had been no impact to shallow, perched groundwater and no current or anticipated unacceptable risk to human health and the environment. The State of Nebraska did not concur with the recommendation to stop monitoring but did agree to a reduction in sampling and analysis from once a year to once every 2 years--a schedule that began in 2008. An updated assessment of the groundwater monitoring effort was issued in 2016. The entire body of water-quality data continues to demonstrate that there have been no negative impacts to the shallow, perched groundwater from radioactive materials entombed at the site 46 years ago. LM, with concurrence from Nebraska DHHS, changed the sampling frequency, effective in 2018, as follows: once every 5 years from 2021 to 2041 and once every 10 years from 2041 to 2071. In summary, LM remains committed to its primary mission to protect human health and the environment at each of its 92 legacy sites. With results from groundwater sampling events demonstrating compliance for 48 years, the Hallam site was able to set an LM benchmark to optimize long-term stewardship and define an end-state strategy for other decommissioned reactor facilities across the DOE complex. Continued collaboration with local communities, stakeholder, and regulators often leads to outcomes of sound protectiveness without compromise to safety or compliance, as demonstrated by the optimization of the long-term stewardship at the Hallam site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical Emissions of Residential Materials and Products: Review of Available Information

This report is prepared in the context of a larger program whose mission is to advance understanding of ventilation and indoor air quality in U.S. homes. A specific objective of this program is to develop the scientific basis ? through controlled experiments, monitoring and analysis ? for health risk-based ventilation standards. Appropriate and adequate ventilation is a basic element of a healthy home. Ventilation provides outdoor air and in the process removes indoor odors and contaminants including potentially unhealthful chemicals emitted by indoor materials, products and activities. Ventilation traditionally was assured to occur via infiltration of outdoor air through cracks and other leakage pathways in the residential building envelope. As building air tightness is improved for energy efficiency, infiltration can be reduced to inadequate levels. This has lead to the development of standards requiring mechanical ventilation. Though nominally intended to ensure acceptable indoor air quality, the standards are not explicitly tied to health risk or pollutant exposure targets. LBNL is currently designing analyses to assess the impact of varying ventilation standards on pollutant concentrations, health risks and energy use. These analyses require information on sources of chemical pollutant emissions, ideally including emission rates and the impact of ventilation on emissions. Some information can be obtained from recent studies that report measurements of various air contaminants and their concentrations in U.S. residences. Another way to obtain this information is the bottom-up approach of collecting and evaluating emissions data from construction and interior materials and common household products. This review contributes to the latter approach by summarizing available information on chemical emissions from new residential products and materials. We review information from the scientific literature and public sources to identify and discuss the databases that provide information on new or low-emission materials and products. The review focuses on the primary chemical or volatile organic compound (VOC) emissions from interior surface materials, furnishings, and some regularly used household products; all of these emissions are amenable to ventilation. Though it is an important and related topic, this review does not consider secondary pollutants that result from reactions of ozone and unsaturated organics bound to or emitted from material surfaces. Semi-volatile organic compounds (SVOCs) have been largely excluded from this review because ventilation generally is not an effective way to control SVOC exposures. Nevertheless, health concerns about exposures to SVOCs emitted from selected materials warrant some discussion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report On Non-Intrusive Load Monitoring Of Welding Processes

The conventional method of weld process monitoring is to monitor the process output electrical power close to the point of welding. Non-Intrusive Load Monitoring (NILM) describes the method of monitoring primary or utility electrical power into a welding process well away from the point of welding. The objective of this project was to determine if there is sufficient information within the welding process input power to understand process output power characteristics, and, if so, determine if there is sufficient resolution within the input electrical characteristics to infer some measures of weld quality. To understand the relationship between process input and output power, both input and output power were monitored for two welding processes (GMAW and GTAW) and two different power source types (inverter and SCR). Welds were made with and without intentional disturbances. The results showed that there is a strong correlation between input and output power and that the influence of process disturbances are evident within the input power. A simple method using input power only was devised and successfully demonstrated to discriminate between a weld made with no intentional disturbance (a nominal weld) from a weld made with an intentional disturbance (off-nominal weld). The primary conclusions of this work is that NILM of process input power is sensitive to process disturbances that could influence weld quality and that the approach warrants additional study.

36 MATERIALS SCIENCE↗

Evaluation of Pre- and Post- Redevelopment Groundwater Chemical Analyses from LM Monitoring Wells

This report documents the efforts and analyses conducted for the Applied Studies and Technology (AS&T) Ancillary Work Plan (AWP) project titled Evaluation of Pre- and Post- Redevelopment Groundwater Sample Laboratory Analyses from Selected LM Groundwater Monitoring Wells. This effort entailed compiling an inventory of nearly 500 previous well redevelopment events at 16 U.S. Department of Energy Office of Legacy Management (LM) sites, searching the literature for impacts of well redevelopment on groundwater sample quality, and—the focus of this report—evaluating the impacts of well redevelopment on field measurements and sample analytical results. Study Catalyst Monitoring well redevelopment, the surging or high-volume pumping of a well to loosen and remove accumulated sediment and biological build-up from a well, is considered an element of monitoring well maintenance that is implemented periodically during the lifetime of the well to mitigate its gradual deterioration. Well redevelopment has been conducted fairly routinely at a few LM sites in the western United States (e.g., the Grand Junction office site and the Gunnison processing site in Colorado), but at most other sites in this region it is not a routine practice. Also, until recently (2014–2015), there had been no specific criteria for implementing well redevelopment, and documentation of redevelopment events has been inconsistent. A catalyst for this evaluation was the self-identification of these inconsistencies by the Legacy Management Support contractor. As a result, in early 2015 Environmental Monitoring Operations (EMO) staff began collecting and documenting additional field measurements during well redevelopment events. In late 2015, AS&T staff undertook an independent internal evaluation of EMO's well redevelopment records and corresponding pre- and post-well-redevelopment groundwater analytical results. Study Findings Although literature discussions parallel the prevailing industry-wide assumption that well redevelopment is necessary to increase production or to extend the life of a well, no data in the literature indicate that redevelopment affects chemical signatures in monitoring wells. The comprehensive evaluation undertaken for this study also yielded no evidence that redevelopment has any quantifiable or predictable effect on groundwater sample quality. Both short-term and long-term changes in groundwater chemistry were assessed relative to preceding and subsequent well redevelopment events. Although short-term changes in specific conductance or contaminant concentrations likely attributable to well redevelopment were found at some sites, these cases were limited to a small subset of wells in which chemical stratification had been observed. Redevelopment causes mixing of the well water, resulting in short-term impacts, but not in a consistent direction. Long-term groundwater concentration trends of uranium, the primary contaminant of concern at most LM Uranium Mill Tailings Radiation Control Act (UMTRCA) sites, were evaluated for all 16 sites addressed in this study. Based on the data evaluated, there are no apparent impacts of well redevelopment on uranium trends. In most cases where deviations in trends were found, these could be attributed to water level fluctuations or other factors. A few exceptions were found where spikes or marked decreases in uranium concentrations could potentially be related to the preceding well redevelopment, but apparent impacts were neither predictable nor quantifiable. Summary and Recommendations A catalyst for this project was a concern that there was a need for strict criteria for a program-wide approach to well redevelopment at LM sites. There was also an implicit question as to whether well redevelopment was a necessary practice that was being overlooked at some sites. The primary objective of this study was to determine if there are significant differences in laboratory analytical results between pre- and post-redevelopment groundwater samples. Results of this evaluation indicate that this is not the case—groundwater concentrations of uranium, the primary contaminant of concern at most LM UMTRCA sites, generally remained unchanged pre- and post-well-redevelopment. The literature supports redevelopment of monitoring and municipal wells if signs of reduced productivity, biofouling, sediment buildup, or other conditions potentially affecting long-term well integrity are observed. In these cases, use of a downhole camera to examine the condition of the well screen and casing may be useful. However, based on the data sets examined for this study, there is no evidence that well redevelopment is needed in order to obtain samples that have the same chemical concentrations as those in the groundwater. To conclusively demonstrate that point—that is, to define chemical effects—the underlying mechanisms have to be understood. For example, if biofouling is observed in a well and is considered a potential cause of spurious or invalid chemical data, appropriate hypothesis-testing ethodology should be used to test the validity of this claim. Until late 2014, the onset of this project, there was no standard procedure for documenting well redevelopment events; some (perhaps many) had not been captured in the historical record. EMO has made notable progress in this regard since 2015, having established a format for documenting well redevelopment events and associated field measurements, as well as a data repository for capturing those records. This policy should be continued to ensure that all well redevelopment events and associated field observations are recorded and easily tracked.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗

Strategy Guideline: Application of a Construction Quality Process to Existing Home Retrofits

The Home Innovation Research Labs developed a construction quality process for new and existing high performance homes (HPH) in which high performance goals are established, specifications to meet those goals are defined, and construction monitoring points are added to the construction schedule so that critical energy efficiency details are systematically reviewed, documented, and tested in a timely manner. This report follows the evolution of the construction quality process from its development for new homes, to its application in the construction of a high performance home with enhanced specifications, and its application in a crawlspace renovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAO/NASA joint investigation of astronomical viewing quality at Mount Hopkins Observatory: 1969-1971

Quantitative measurements of the astronomical seeing conditions have been made with a stellar-image monitor system at the Mt. Hopkins Observatory in Arizona. The results of this joint SAO-NASA experiment indicate that for a 15-cm-diameter telescope, image motion is typically 1 arcsec or less and that intensity fluctuations due to scintillation have a coefficient of irradiance variance of less than 0.12 on the average. Correlations between seeing quality and local meteorological conditions were investigated. Local temperature fluctuations and temperature gradients were found to be indicators of image-motion conditions, while high-altitude-wind conditions were shown to be somewhat correlated with scintillation-spectrum bandwidth. The theoretical basis for the relationship of atmospheric turbulence to optical effects is discussed in some detail, along with a description of the equipment used in the experiment. General site-testing comments and applications of the seeing-test results are also included.

Pearlman, M. R.↗

Moisture Monitoring at Area G, Technical Area 54, Los Alamos National Laboratory

Hydrological characterization and moisture monitoring activities provide data required for evaluating the transport of subsurface contaminants in the unsaturated and saturated zones beneath Area G, and for the Area G Performance Assessment and Composite Analysis. These activities have been ongoing at Area G, Technical Area 54 of the Los Alamos National Laboratory since waste disposal operations began in 1957. This report summarizes the hydrological characterization and moisture monitoring activities conducted at Area G. It includes moisture monitoring data collected from 1986 through 2014 from numerous boreholes and access tubes with neutron moisture meters, as well as data collected by automated dataloggers for water content measurement sensors installed in a waste disposal pit cover, and buried beneath the floor of a waste disposal pit. This report is an update of the Jennings and French (2009) moisture monitoring report and includes all data from Jennings and French (2009) and the Draft 2010 Addendum moisture monitoring report (Jennings and French, 2010). For this updated report, all neutron logging data, including neutron probe calibrations, were investigated for quality and pedigree. Some data have been recalculated using more defensible calibration data. Therefore, some water content profiles are different from those in the Jennings and French (2009) report. Monitoring and characterization data generally indicate that some areas of the Area G vadose zone are consistent with undisturbed conditions, with water contents of less than five percent by volume in the top two layers of the Bandelier tuff at Area G. These data also indicate that other areas of the vadose zone are affected by waste disposal activities that have been ongoing at Area G since 1957, a period of nearly 60 years. In some areas, water content profiles indicate increases in water content to depths of tens of meters, especially in areas covered by asphalt and structures.

54 ENVIRONMENTAL SCIENCES↗

Dense Non Aqueous Phase Liquid Source Area Delineation Using Membrane Interface Probe and Hydraulic Profile Tool Technology at Space Launch Complex 16, Cape Canaveral Air Force Station, Florida - 16352

The historical use and disposal of chlorinated solvents throughout Department of Defense and Department of Energy sites has resulted in subsurface contamination by dense non-aqueous phase liquids (DNAPL). The nature and environmental persistence of DNAPLs makes delineation and remediation of these compounds challenging and costly. This paper examines the utilization of data from a membrane interface probe (MIP) and hydraulic profile tool (HPT) to reduce a typical 18 to 24 month field investigation to 3 months; thereby, significantly reducing costs and resulting in a three-dimensional (3D) imagery of a deep DNAPL plume in order to support an aggressive remedial design for Space Launch Complex 16 (SLC16) at Cape Canaveral Air Force Station, Florida. During the early stages of the U.S. space program, chlorinated solvents were routinely used at space complexes. Spent solvents were discharged to surface impoundments where they migrated into the subsurface. Over time, these chlorinated solvents reached concentrations high enough to form a DNAPL plume. Recent investigations near SLC16 identified a previously unknown DNAPL plume co-mingled with dissolved-phase chlorinated compounds. The DNAPL source area (concentrations of trichloroethene [TCE] as high as 1,000,000 micrograms per liter [μg/L]) was discovered approximately 1,200 feet (ft) west of the existing monitoring network area. The U.S. Air Force, along with the U.S. Army Corps of Engineers, developed data quality objectives (DQO) to delineate the extent of the DNAPL and the dissolved-phase contaminant plume. A multi-phase investigation approach was developed by HydroGeoLogic, Inc. (HGL) emphasizing the use of MIP and HPT sampling technologies, conventional direct push technology (DPT), and monitoring well sampling methods. This approach allowed the collection of real-time data that supported the project DQOs and significantly reduced overall project costs and the field implementation schedule. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗