Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has been considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrothermal Growth of Magnetically Frustrated Crystals: Lanthanide Stannate Pyrochlores as a Prototype

One important test bed system for frustrated magnetism is the pyrochlore lattice with the formula A2B2O7 in the cubic space group Fd3(-)m. Both the A and B sites occupy crystallographic trigonal sites and both sites possess a tetrahedral relationship with the other similar metal ion sites. These symmetry relationships generate a 3 D frustrated structure. In frustrated magnetic systems, typically a trivalent lanthanide ion occupies the A site and a magnetically silent tetravalent ion (Ti, Zr, Sn, etc.) occupies the B site. A classical problem related to the crystal growth of these compounds is sample quality. As refractory oxides, the traditional synthesis and crystal growth techniques require high temperatures, which creates two problems that are quite common and endemic to the pyrochlores. One is oxide lattice defects and the other is A/B site disorder. Both issues often occur in the same crystals at the same time and can have a significant impact on the study of physical properties. A hydrothermal approach can be applied to this problem. The relatively low crystal growth temperatures (600-720˚C) greatly minimize nonstoichiometry, lattice defects and A/B site disorder. The reduction of these pervasive imperfections significantly increases the quality of the observed physical property data. This talk will focus on the lanthanide stannates Ln2Sn2O7 as a prototype test bed of these systems. The stannates are among the few building blocks that can stabilize the pyrochlore structure type for all the lanthanides and they serve as an excellent proving ground for a wide range of physical properties. The synthesis and crystal growth of the lanthanide stannates will be reviewed, along with a discussion of some of the physical properties that result from the frustrated magnetic states of these low defect crystals.

Hydrothermal, crystal growth↗

1D Modeling for the Development of a Digital Twin for Hydropower Systems with Applications for a Testing Rig

Modeling and simulation constitute two important parts in constructing a sensible digital twin to mimic the dynamics of hydropower systems. Because of the physical nature of a hydropower system, the basic modeling should cover the water flow systems from the reservoir to the penstock (inlet water pipes), penstock to hydro turbine, and hydro turbine to generator and from the linkage of the hydropower systems to the grid. This report describes initial attempts to model these dynamic components, including the formulation of the linearized state space model for hydro turbine systems using the well-known six-coefficients linearization method and the formulation of the voltage and power dynamical models of a synchronous generator. To validate the accuracy of the proposed model, data collected from Norwegian University of Science and Technology were used to obtain relevant parameters for the model, and the desired simulation results were obtained. Additionally, neural network modeling and learning were also developed and applied to model the generation torque and water flow rate subsystems to demonstrate a potential learning scheme, which can be used in the development of a digital twin.

13 HYDRO ENERGY↗

Iodine Removal in the DFLAW Flow-Sheet

In support of the WTP project, off-gas system and regulatory testing has been conducted previously on the DM1200 pilot melter equipped with a prototypical off-gas system installed at The Catholic University of America’s Vitreous State Laboratory (VSL). During the regulatory tests, an AC-S test bed filled with Kombisorb BAT 37 was included in the prototypical off-gas system and evaluated for response to HLW and LAW exhaust streams. Offline testing and small-scale testing of that media were also conducted. Testing demonstrated that a temperature rise occurred in the activated carbon media when water vapor was first introduced to virgin Kombisorb BAT 37, in response to high nitrogen oxide concentrations, and in response to the presence of organic compounds. Conditioning of the test bed by gradually increasing the NOx concentration prior to the introduction of organics was found to be an important operational strategy for preventing larger temperature excursions. However, no mercury was present in the exhaust stream during DM1200 testing and therefore comparable test data for mercury removal efficiency or temperature response of the carbon media in the presence of mercury were not collected in the DM1200 tests. In view of the need for data on mercury removal performance, BNI contracted with Atkins and the VSL to install and operate a suitable test system at VSL to collect the required data. That testing was designed to assess the performance of Kombisorb BAT-37 and the guard bed material, Sofnolime RG, for simulated melter exhaust streams that contain the highest concentrations of mercury, nitrogen oxides, acid gases, and organic compounds expected in WTP LAW melter exhaust. During shakedown testing with the new system, however, it became evident that a number of issues with Sofnolime RG as the guard bed material would render it unsuitable for this application. BNI subsequently determined that the guard bed was redundant for removal of acid gases since they could be adequately removed by the SBS and WESP. However, since the guard bed material was also credited with significant iodine removal , there was a need for a replacement material that would adequately perform that role. BNI identified several candidate media but performance data in gas compositions that are representative of the WTP LAW off-gas were not available. Accordingly, there was a need to test and evaluate the performance of these candidate media prior to performing the originally-planned tests. To that end, small scale tests were conducted to assess the performance of various adsorbents in simulated melter exhaust streams that contain mercury, iodine, nitrogen oxides, acid gases, and acetonitrile, which are expected to be present in WTP LAW melter exhaust.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Taming parallel I/O complexity with auto-tuning

We present an auto-tuning system for optimizing I/O performance of HDF5 applications and demonstrate its value across platforms, applications, and at scale. The system uses a genetic algorithm to search a large space of tunable parameters and to identify effective settings at all layers of the parallel I/O stack. The parameter settings are applied transparently by the auto-tuning system via dynamically intercepted HDF5 calls. To validate our auto-tuning system, we applied it to three I/O benchmarks (VPIC, VORPAL, and GCRM) that replicate the I/O activity of their respective applications. We tested the system with different weak-scaling configurations (128, 2048, and 4096 CPU cores) that generate 30 GB to 1 TB of data, and executed these configurations on diverse HPC platforms (Cray XE6, IBM BG/P, and Dell Cluster). In all cases, the auto-tuning framework identified tunable parameters that substantially improved write performance over default system settings. In conclusion, we consistently demonstrate I/O write speedups between 2x and 100x for test configurations.

97 MATHEMATICS AND COMPUTING↗

Mathematical test criteria for filtering complex systems: Plentiful observations

An important emerging scientific issue is the real time filtering through observations of noisy turbulent signals for complex systems as well as the statistical accuracy of spatio-temporal discretizations for such systems. These issues are addressed here in detail for the setting with plentiful observations for a scalar field through explicit mathematical test criteria utilizing a recent theory [A.J. Majda, M.J. Grote, Explicit off-line criteria for stable accurate time filtering of strongly unstable spatially extended systems, Proceedings of the National Academy of Sciences 104 (4) (2007) 1124-1129]. For plentiful observations, the number of observations equals the number of mesh points. These test criteria involve much simpler decoupled complex scalar filtering test problems with explicit formulas and elementary numerical experiments which are developed here as guidelines for filter performance. The theory includes information criteria to avoid filter divergence with large model errors, asymptotic Kalman gain, filter stability, and accurate filtering with small ensemble size as well as rigorous results delineating the role of various turbulent spectra for filtering under mesh refinement. These guidelines are also applied to discrete approximations for filtering the stochastically forced dissipative advection equation with very turbulent and noisy signals with either an equipartition of energy or -5/3 turbulent spectrum with infrequent observations as severe test problems. The theory and companion simulations demonstrate accurate statistical filtering in this context with implicit schemes with large time step with very small ensemble sizes and even with unstable explicit schemes under appropriate circumstances provided the filtering strategies are guided by the off-line theoretical criteria. The surprising failure of other strongly stable filtering strategies is also explained through these off-line criteria.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM and US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance levels of EPID-based quality control for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) includes features such as a variable dose rate and gantry speed in addition to the beam modulation achieved with multileaf collimator (MLC) motion patterns employed in intensity modulated radiotherapy. Three tests have previously been proposed for the evaluation of the performance of VMAT delivery. In order to enable a convenient and accurate routine machine quality control (QC) program, the present study proposes tolerance levels for these tests based on a department-wide implementation of an electronic portal imaging device (EPID)-based QC. Methods: Three different VMAT tests--a picket fence (PF) test, a dose rate versus gantry speed (DRGS) test, and a dose rate versus MLC leaf speed (DRMLC) test--were performed on nine accelerators using two different EPIDs (aS1000 and aS500, Varian Medical Systems). All tests were repeated six times for each accelerator. The images were analyzed using an in-house-developed software. For the PF test, the positions and widths of individual MLC leaf gaps were compared to the mean value. In the DRGS and DRMLC tests, different combinations of dose rate, gantry speed, and MLC leaf speed were used to deliver identical doses to separate parts of the EPID. The tests were evaluated by looking for deviations in the constancy of the measured dose for the preset combinations of dose rate, gantry speed, and MLC leaf speed. Results: For the PF test, a 0.3 mm tolerance level was suggested for the positioning of the MLC leaves. The tolerance level for the gap width was 0.5 mm. For the DRGS and DRMLC tests, a 3% tolerance level was proposed. Conclusions: With the adapted levels of tolerance for an EPID-based approach, the PF, the DRGS, and the DRMLC tests offer a convenient and accurate machine QC program for linear accelerators used for VMAT.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-CAMPUS-I-05: Investigation of An EMCCD Detector with Variable Gain in a Micro-CT System

Purpose: To investigate the performance of a newly built Electron Multiplying Charged Coupled Device (EMCCD) based Micro-CT system, with variable detector gain, using a phantom containing contrast agent of different concentrations. Methods: We built a micro- CT system with an EMCCD having 8 microns pixels and on-chip variable gain. We tested the system using a phantom containing five tubes filled with different iodine contrast solutions (30% to 70%). First, we scanned the phantom using various x-ray exposures values at 40 kVp and constant detector gain. Next, for the same tube currents, the detector gain was increased to maintain the air value of the projection image constant. A standard FDK algorithm was used to reconstruct the data. Performance was analyzed by comparing the signal-to-noise ratio (SNR) measurements for increased gain with those for the low constant gain at each exposure. Results: The high detector gain reconstructed data SNR was always greater than the low gain data SNR for all x-ray settings and for all iodine features. The largest increases were observed for low contrast features, 30% iodine concentration, where the SNR improvement approached 2. Conclusion: One of the first implementations of an EMCCD based micro- CT system was presented and used to image a phantom with various iodine solution concentrations. The analysis of the reconstructed volumes showed a significant improvement of the SNR especially for low contrast features. The unique on-chip gain feature is a substantial benefit allowing the use of the system at very low x-ray exposures per frame.Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp. Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

The Machine Protection System for the Fermilab Accelerator Science and Technology Facility

The Machine Protection System (MPS) for the Fermilab Accelerator Science and Technology Facility (FAST) has been implemented and tested. The system receives signals from several subsystems and devices which conveys the relevant status needed to the safely operate the accelerator. Logic decisions are made based on these inputs and some predefined user settings which in turn controls the gate signal to the laser of the photo injector. The inputs of the system have a wide variety of signal types, encoding methods and urgencies for which the system is designed to accommodate. The MPS receives fast shutdown (FSD) signals generated by the beam loss system and inhibits the beam or reduces the beam intensity within a macropulse when the beam losses at several places along the accelerator beam line are higher than acceptable values. TTL or relay contact signals from the vacuum system, toroids, magnet systems etc., are chosen with polarities that ensure safe operation of the accelerator from unintended events such as cable disconnection in the harsh industrial environment of the experimental hall. A RS422 serial communication scheme is used to interface the operation permit generator module and a large number of movable devices each reporting multi-bit status. The system also supports operations at user defined lower beam levels for system conunissioning. The machine protection system is implemented with two commercially available off-the-shelf VMEbus based modules with on board FPGA devices. The system is monitored and controlled via the VMEbus by a single board CPU

Wu, Jinyuan↗

Fast-neutron Multiplicity Counter for Passive and Active Measurements of Special Nuclear Material

We developed a fast-neutron multiplicity counter (FNMC) based on organic scintillators (liquid and stilbene). The system is able to detect correlated photon and neutron multiplets emitted by fission reactions. We tested the system both in passive and active operation mode, and present the results of the experiments, both carried out at the Zero Power Physics Reactor of Idaho National Laboratory. The system was operated in coincidence mode (with a gate time of 50 nanoseconds) and two calibration-based approaches were used to estimate the 240Pu effective (240Pueff) and 235U mass of the samples. In passive mode, we assayed two types of plutonium metal plates, i.e. PAHN and PANN, with a 240Pueff mass of 4.7 g and 25.05 g per plate, respectively. The 239Pu mass percentage was 74% for the PAHN and 95% for the PANN series. We measured neutrons emitted in coincidence by several plate assemblies, having an overall 240Pueff mass in the 4.7 g to 500 g range. In active mode, we characterized several uranium samples. We used two AmLi sources (~50000 neutrons emitted per second) to induce fission in the samples. The first six measured samples were certified reference materials (CRM, set 149), having a constant enrichment, i.e. 93.2 wt%, and mass in the range between 0.5 and 4 kg. Additionally, we assayed three CRM-146 samples, with constant total mass of 500 g and an enrichment of 20.1 wt%, 52.8 wt% and 93.2 wt%. In both configurations, the system succeeded in estimating the fissile mass of an unknown sample with a statistical uncertainty lower than 1% (4-minute assay) and 7% (10-minute assay), in passive and active mode, respectively. In passive mode, the statistical uncertainty is lower than the one achieved by standard 3He counters for plutonium metal samples of similar mass. The difference between the estimated and the declared 240Pueff mass, i.e., the bias error, measured by the fast neutron multiplicity counter was consistently lower compared to the bias error of a standard thermal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reactor System Safety: A case for New and Advanced Reactors

This presentation covers a generic overview of reactor system safety testing, analysis, and related research and development (R&D) focusing on new and advanced reactor systems. This presentation is prepared for graduate-level student seminar talks. No specific reactor design information is provided. Only publicly available information and related published articles and book contents are utilized.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A methodology for accident analysis of fusion breeder blankets and its application to helium-cooled lead–lithium blanket

'Fusion for Energy' (F4E) is designing, developing, and implementing the European Helium-Cooled Lead-Lithium (HCLL) and Helium-Cooled Pebble-Bed (HCPB) Test Blanket Systems (TBSs) for ITER (Nuclear Facility INB-174). Safety demonstration is an essential element for the integration of these TBSs into ITER and accident analysis is one of its critical components. A systematic approach to accident analysis has been developed under the F4E contract on TBS safety analyses. F4E technical requirements, together with Amec Foster Wheeler and INL efforts, have resulted in a comprehensive methodology for fusion breeding blanket accident analysis that addresses the specificity of the breeding blanket designs, materials, and phenomena while remaining consistent with the approach already applied to ITER accident analyses. Furthermore, the methodology phases are illustrated in the paper by its application to the EU HCLL TBS using both MELCOR and RELAP5 codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

Experimental neutronics tests for a neutron activation system for the European ITER TBM

We are investigating methods for neutron flux measurement in the ITER TBM. In particular we have tested sets of activation materials leading to induced gamma activities with short half-lives of the order of tens of seconds up to minutes and standard activation materials. Packages of activation foils have been irradiated with the intense neutron generator of Technical University of Dresden in a pure DT neutron field as well as in a neutronics mock-up of the European ITER HCLL TBM. An important aim was to check whether the gamma activity induced in the activation foils in these packages could be measured simultaneously. It was indeed possible to identify gamma lines of interest in gamma-ray measurements immediately after extraction from the irradiation.

07 ISOTOPE AND RADIATION SOURCES↗

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

This report summarizes the progress made during the April 01, 2010 – December 30, 2013 period under Cooperative Agreement DE-EE0002752 for the U.S. Department of Energy entitled “High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems.” The overall objective of this program is to advance the technology for well fluids lifting systems to meet the foreseeable pressure, temperature, and longevity needs of the Enhanced Geothermal Systems (EGS) industry for the coming ten years. In this program, lifting system requirements for EGS wells were established via consultation with industry experts and site visits. A number of artificial lift technologies were evaluated with regard to their applicability to EGS applications; it was determined that a system based on electric submersible pump (ESP) technology was best suited to EGS. Technical barriers were identified and a component-level technology development program was undertaken to address each barrier, with the most challenging being the development of a power-dense, small diameter motor that can operate reliably in a 300°C environment for up to three years. Some of the targeted individual component technologies include permanent magnet motor construction, high-temperature insulation, dielectrics, bearings, seals, thrust washers, and pump impellers/diffusers. Advances were also made in thermal management of electric motors. In addition to the overall system design for a full-scale EGS application, a subscale prototype was designed and fabricated. Like the full-scale design, the subscale prototype features a novel “flow-through-the-bore” permanent magnet electric motor that combines the use of high temperature materials with an internal cooling scheme that limits peak internal temperatures to <330°C. While the full-scale high-volume multi-stage pump is designed to lift up to 80 kg/s of process water, the subscale prototype is based on a production design that can pump 20 kg/s and has been modified for high-temperature operation. In parallel with the design and fabrication of the subscale prototype ESP system, a subscale test facility consisting of a high-temperature-high-pressure flow loop was designed, fabricated, and installed at GE Global Research in Niskayuna, NY. A test plan for the prototype system was also established. The original plan of testing the prototype hardware in the flow loop was delayed until a future date.

15 GEOTHERMAL ENERGY↗

Numerical Analysis of JNES Seismic Tests on Degraded Combined Piping System

Nuclear power plant safety under seismic conditions is an important consideration. The piping systems may have some defects caused by fatigue, stress corrosion cracking, etc., in aged plants. These cracks may not only affect the seismic response but also grow and break through causing loss of coolant. Therefore, an evaluation method needs to be developed to predict crack growth behavior under seismic excitation. This paper describes efforts conducted to analyze and better understand a series of degraded pipe tests under seismic loading that was conducted by Japan Nuclear Energy Safety Organization (JNES). A special 'cracked-pipe element' (CPE) concept, where the element represented the global moment-rotation response due to the crack, was developed. This approach was developed to significantly simplify the dynamic finite element analysis in fracture mechanics fields. In this paper, model validation was conducted by comparisons with a series of pipe tests with circumferential through-wall and surface cracks under different excitation conditions. These analyses showed that reasonably accurate predictions could be made using the abaqus connector element to model the complete transition of a circumferential surface crack to a through-wall crack under cyclic dynamic loading. The JNES primary loop recirculation piping test was analyzed in detail. This combined-component test had three crack locations and multiple applied simulated seismic block loadings. Comparisons were also made between the ABAQUS finite element (FE) analyses results to the measured displacements in the experiment. Good agreement was obtained, and it was confirmed that the simplified modeling is applicable to a seismic analysis for a cracked pipe on the basis of fracture mechanics. Pipe system leakage did occur in the JNES tests. The analytical predictions using the CPE approach did not predict leakage, suggesting that cyclic ductile tearing with large-scale plasticity was not the crack growth mode for the acceleration excitations considered here. Hence, the leakage was caused by low-cycle fatigue with small-scale yielding. The procedure used to make predictions of low-cycle fatigue crack growth with small-scale yielding was based on the Dowling {Delta}J procedure, which is an extension of linear-elastic fatigue crack growth methodology into the nonlinear plasticity region. The predicted moments from the CPE approach were used using a cycle-by-cycle crack growth procedure. The predictions compare quite well with the experimental measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗