Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trigger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

AAF_UHSAS-air_CACTI

The UHSAS-air is the bench version of the UHSAS that measures particle size from 0.06 to 1.0 micro-meters. Aerosol passes through a laser beam and the resulting intensity of scattered light is directly correlated to the diameter of the particle passing through the beam. This isntrument has been modified to volumetricaly control the Sheath Flow using an Alicat flow controller. Data is reported at 1.000s and missing data is reported as -9999 Multiple data flags are present in this version. Counts?: The coincident error is deemed minimal until the counts exceed 4000. Counts between 3000 and 4000 are flagged with a caution flag (1). After 4000 counts a bad flag (2) is triggered and the data should not be used. Noise?: Instrument noise detected in 65-75nm size range. 1: Caution slight noise observed. 2: High amount of noise observed data should not be used. Total? Sum of all the flags triggered Max Flag: Max flag triggered by the above QC test CloudFlag: Warns of the presence of a cloud. Clouds can cause shattering on the probe and result in questionable measurements. Data during these periods of thin clouds (1) or heavy clouds (2) should be used with extreme caution.

54 ENVIRONMENTAL SCIENCES↗

Linear servomotor probe drive system with real-time self-adaptive position control for the Alcator C-Mod tokamak

A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enables self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. In addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ratemeter

An instantaneous reading tachometer in which reoccurring events to be measured in rate, trigger a threestate timing generator in which the first two states are of fixed duration and the third state is of variable duration is described. An electrical decay circuit is set to a reference level by the second state and the third state causes this reference level to decay until the reoccurrence of an event. This triggers a new first state which in turn triggers a sample and hold circuit to hold the decayed level. The decayed level is amplified and provided as an output indicative of the instantaneous rate of occurence of the last two successive events.

Currie, J. R.↗

VLF line radiation in the earth's magnetosphere and its association with power system radiation

In a recent experiment, discrete VLF emissions from the magnetosphere were triggered by a transmitter at Siple Station in Antarctica. Spectrograms of these signals as received at the conjugate point, Roberval, Quebec, showed changes in slope, entrainments, and cutoffs at frequencies (several kilohertz) close to the harmonic induction lines from the local 60-Hz power system. This observation led to the suggestion that harmonic radiation from the power system enters the magnetosphere and interacts with the triggered emissions. New evidence supporting this suggestion has been found in spectrograms of simultaneous recordings made at Roberval and at Siple Station in Antarctica. It is shown that line radiation, near harmonics of 60 Hz, travels along the earth's magnetic field in the whistler mode and is received in the conjugate hemisphere at Siple Station. Echoing of the line radiation between Siple and Roberval is often observed. The magnetospheric lines are usually shifted in frequency by 20-30 Hz with respect to the adjacent induction line, but their spacings are near 120 Hz. They may trigger and cut off emissions as do signals from VLF transmitters.

Helliwell, R. A.↗

An investigation of high-multiplicity gamma events in pp collisions with c.m. energies between 22 and 62 GeV

An experiment was conducted at the CERN intersecting storage rings using colliding proton beams to investigate high-multiplicity gamma-ray events. The objective of the study was to reveal certain features of multiple pion production as well as other possible mechanisms of gamma-ray production. The detector system consisted of ten planes of spark chambers, three scintillation counter hodoscopes and two arrays of lead-glass Cerenkov counters, the first array containing 16 counters and the second, 60 counters. The event trigger was obtained from the Cerenkov counters, and the energies in all the Cerenkov counters after trigger, as well as the information on all the charged particles given by the scintillation counters and spark chambers were recorded on magnetic tape. The relationship between the number of gamma-rays per event and the number of Cerenkov counters triggered by a neutral secondary was established by means of a Monte Carlo calculation.

Dell, G. F.↗

Energy storage and deposition in a solar flare

X-ray pictures of a solar flare taken with the S-056 X-ray telescope aboard Skylab are interpreted in terms of flare energy deposition and storage. The close similarity between calculated magnetic-field lines and the overall structure of the X-ray core is shown to suggest that the flare occurred in an entire arcade of loops. It is found that different X-ray features brightened sequentially as the flare evolved, indicating that some triggering disturbance moved from one side to the other in the flare core. A propagation velocity of 180 to 280 km/s is computed, and it is proposed that the geometry of the loop arcade strongly influenced the propagation of the triggering disturbance as well as the storage and site of the subsequent energy deposition. Some possible physical causes for the sequential X-ray brightening are examined, and a magnetosonic wave is suggested as the triggering disturbance. 'Correct' conditions for energy release are considered

Vorpahl, J. A.↗

A continuous/discrete simulation for interplanetary spacecraft

The paper gives a general description of a continuous/discrete simulator of the telemetry flow from an unmanned interplanetary spacecraft in flight. The real time simulation method is based on the trigger method, where a trigger is a set of control words which describe a condition and an action to be taken upon satisfaction of the condition. Simulation consists of finding the points at which the given condition is satisfied and taking the specified action. The paper describes the four kinds of triggers and how they are called. The calculational algorithm used to advance time in the simulator is briefly described.

Lesh, F.↗

VLF wave-wave interaction experiments in the magnetosphere

VLF wave-wave interaction experiments were carried out by injecting various forms of VLF pulses into the magnetosphere from a 21.2 km dipole antenna at Siple, Antarctica. The injected signals propagate along a geomagnetic field line and often interact strongly with energetic electrons trapped in the radiation belts near the equator. Signals may be amplified and trigger emissions. These signals may then interact with one another through these energetic electrons. This report is divided into three parts. In the first part, simulations of VLF pulses propagating in the magnetosphere are carried out. In the second part, it is found for the first time that a 10 ms gap in a triggering wave can induce emission, which may then interact with the post-gap signals. In the third part, sideband triggering is reported for the first time.

Chang, D. C. D.↗

Are large concentration of atomic H storable in tritium-impregnated solid in H2 below 0.10 K

The storage and release of atomic hydrogen produced by the beta decay of tritium contained in a crystalline solid H2 matrix at concentrations greater than 2% and temperatures below 0.80 K are investigated. The temperature of a sample chamber containing tritium-impregnated H2 and placed in the mixing chamber of a dilution refrigerator was measured as the chamber was heated and cooled in order to determine the rates of energy storage and release. It is found that for samples containing 1.2 wt.% tritium, after storage at 0.054 K for 40 h, an increase in sample temperature to a trigger point of 0.17 K leads to an energy release due to the destabilization of atomic H in H2 as predicted by the phenomenological rate process theory. For a tritium weight fraction of 2.5%, energy releases were triggered at 0.54 and 0.82 K after storage at 0.080 K, indicating the trapping of H atoms at the sites of T2 and HT molecules in the sample. The application of a 15 kG magnetic field is shown to increase the storage capacity of T2 traps while reducing that of HT traps, and to lower the trigger temperatures of both. Results suggest that the direct conversion of nuclear energy to chemical energy may become technically feasible in the future.

Rosen, G.↗

Presupernova models and supernovae

The present status of theories of presupernova stellar evolution and the triggering mechanisms of supernova explosions are reviewed. The validity of the single-star approximation for stellar core evolution is considered, and the central density and temperature of the stellar core are discussed. Attention is then given to the results of numerical models of supernova explosions by carbon deflagration of an intermediate mass star, resulting in the total disruption of the star; the photodissociation of iron nuclei in a massive star, resulting in neutron star or black hole formation; and stellar core collapse triggered by electron capture in stars of mass ranging between those of the intermediate mass and massive stars, resulting in neutron star formation despite oxygen deflagration. Helium and carbon combustion and detonation in accreting white dwarfs and the gravitational collapse triggered by electron-pair creation in supermassive stars are also discussed, and problems requiring future investigation are indicated.

Sugimoto, D.↗

Jikiken /EXOS-B/ observation of Siple transmissions

Preliminary results of observations by the Japanese magnetospheric satellite Jikiken (EXOS-B) of Siple transmissions and VLF emissions triggered by the Siple signals are reviewed. The experiments discussed were carried out in July, August, and September of 1979 and in December 1979 and January 1980. Only four events concentrated within the period from August 14 to 18 were found in which triggered emissions were associated with Siple transmissions. The electron distributions observed on the equatorial crossing passes, when Siple triggered emissions were detected, suggest that the cyclotron resonance condition is satisfied for Siple signals and electrons of energy around 1 keV or less, provided the interaction region is inside the plasmapause. It is noted that if these emissions were generated outside the plasmapause, electron energies much higher than 10 keV would be necessary for the cyclotron interaction, which were above the range of the measurements. For the high latitude passes of August 14 and 17, the electron fluxes were found to be very small.

Kimura, I.↗

Pulsed plasma thruster ignitor plug ignition characteristics

The operating characteristics of the semiconductor spark gap ignitor plug used to initiate the discharge in a pulsed plasma thruster are investigated. Current and voltage waveform measurements for the ignitor plug alone, and for the plug mounted in the thruster cathode indicate an average dynamic impedance of 0.2 ohms for a wide range of operating conditions, and a trigger circuit energy transfer efficiency to the plug on the order of 25%. Two modes of trigger ignition are found which are related to the rise time of the applied voltage pulse. Analysis of plasma characteristics reveals plug erosion to occur primarily in the semiconductor and anode regions, by mechanisms including plug metal embrittlement, plasma sputtering and vaporization caused by the discharge current pulse. Measurements also indicate a plume velocity on the order of 1580,000 cm/sec which increases with trigger circuit stored energy. The results establish levels of performance for future applications of semiconductor spark gap ignitor plugs in plasma devices.

Brady, M. E.↗

DE-1 observations of VLF transmitter signals and wave-particle interactions in the magnetosphere

A broadband VLF receiver on the DE-1 satellite measures signals injected into the magnetosphere by ground-based transmitters. VLF emissions triggered by these signals indicate that the waves interact strongly with trapped energetic particles in the magnetosphere. The propagation paths from the source to the satellite are deduced on the basis of the group time delay and Doppler shift. Although there are many different paths, emissions are triggered by the later-arriving pulses that have traversed the geomagnetic equator. First satellite-based observations of emission triggering by high-power communications transmitters and their possible implications are discussed.

Inan, U. S.↗

Study of muons near shower cores at sea level using the E594 neutrino detector

The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter.

Goodman, J. A.↗

Methods for roof-top mini-arrays

To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

Hazen, W. E.↗

High-Voltage Switch Containing (DI)2 Devices

Series switching diodes triggered on by passing above threshold voltage. High-voltage switch made by connecting multitude of deep-impurity, double-injection devices in series with each other and with another, triggerable high-voltage device such as thyristor. Device operates near ground potential to avoid insulation problems in triggering circuit.

Hanes, Maurice H.↗

Return stroke velocities and currents using a solid state silicon detector system

A small, portable device has been developed to measure return stroke velocities. With the device, velocities from 135 strokes that consist of 92 natural return strokes and 43 triggered return strokes have been analyzed. The average return stroke velocity for longer channels, greater than 500 meters, is 1.2 + or - 0.3 x 10 to the 8th m/s for both natural and triggered return strokes. For shorter channel lengths, less than 500 m, natural lightning has a statistically higher average return stroke velocity of 1.9 + or - 0.7 x 10 to the 8th m/s than triggered lightning with an average return stroke velocity of 1.4 + or - 0.4 x 10 to the 8th m/s. Using the transmission line model of the return stroke, natural lightning has a peak current distribution that is log-normal with a median value of 19 kA. Return stroke velocities and currents were determined for two distant single stroke natural positive cloud-to-ground flashes. The velocities were 1.0 and 1.7 x 10 to the 8th ms/s while the estimated peak current for each positive flash was over 125 kA.

Mach, Douglas M.↗

Deployable robotic woven wire structures and joints for space applications

Deployable robotic structures are basically expandable and contractable structures that may be transported or launched to space in a compact form. These structures may then be intelligently deployed by suitable actuators. The deployment may also be done by means of either airbag or spring-loaded typed mechanisms. The actuators may be pneumatic, hydraulic, ball-screw type, or electromagnetic. The means to trigger actuation may be on-board EPROMS, programmable logic controllers (PLCs) that trigger actuation based on some input caused by the placement of the structure in the space environment. The actuation may also be performed remotely by suitable remote triggering devices. Several deployable woven wire structures are examined. These woven wire structures possess a unique form of joint, the woven wire joint, which is capable of moving and changing its position and orientation with respect to the structure itself. Due to the highly dynamic and articulate nature of these joints the 3-D structures built using them are uniquely and highly expandable, deployable, and dynamic. The 3-D structure naturally gives rise to a new generation of deployable three-dimensional spatial structures.

Shahinpoor, MO↗