Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Schema Elements for Granta Annual Report: FY2024

Granta: Materials Intelligence (Granta: MI) is a commercial database software distributed by Ansys, Inc. that is utilized by the Nuclear Security Enterprise (NSE) to organize and store relevant materials data. Lack of standard and well-documented database schema is the primary obstacle to an NSE materials data management solution, so the objective of this project is to create and document such a schema. In FY21, an approach for designing, documenting, and managing a standard database schema was described based on the creation of schema elements (collections of attributes used to describe particular aspects of the data) to be used as building blocks for creating various database tables without duplication. In FY22, these methods were applied through a multi-site collaboration to create and document the schema elements necessary to build a thermogravimetric analysis (TGA) testing table. In FY23 the schema was expanded to include elements for a differential scanning calorimetry (DSC) table, along with schema for supporting metadata tables including Instruments, Projects, Documents, and Testing Series. In FY24 the following progress was made, again through multi-site collaboration: • The existing schema elements were modified to accommodate thermomechanical analysis (TMA) data, and a table, Test Data: TMA, was created for managing TMA data. • The elements necessary for the following additive manufacturing (AM) data tables (directed at data specific to selective laser sintering AM technology) were created: • AM Builds • AM Processes • AM Part Designs • Built AM Parts • AM Feedstock Materials • AM Feedstock Material Batches • The elements necessary for creating a Calibrated Material Models table were created, and the Calibrated Material Models table was created. In FY25 the existing schema will be deployed on the production enterprise Granta instance on the enterprise secure network. Schema elements will be appended, and new elements created as necessary, to allow the creation of tables specifically to support materials testing, AM process development, and design and analysis for modernization programs.

36 MATERIALS SCIENCE↗

The National Ignition Facility Data Repository

NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion and matter at extreme energy densities and pressures. This presentation discusses the design, architecture, and implementation of the NIF Data Repository (NDR), which provides for the capture and long-term digital storage of peta-scale datasets produced by conducting experimental campaigns. The NDR is a federated database that provides for the capture of: experimental campaign plans, machine configuration & calibration data, raw experimental results and the processed results produced by scientific workflows. The NDR provides for metadata, pedigree, quality, effectivity, versioning and access control for each of the data categories. A critical capability of the NDR is its extensive data provisioning capabilities and protocols that enable scientists, local and remote alike, to review the results of analysis produced by the NDR's analysis pipeline or to download datasets for offline analysis. The NDR provides for the capture of these locally-produced analysis results to enable both peer review and follow-on automated analysis.

42 ENGINEERING↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decadal carbon decomposition dynamics in three peatlands in Northern Minnesota

The uppermost portion of the peat profile, an area of active diagenetic processes, is exceedingly important for understanding peatland dynamics and the diagenesis and geochemistry of atmospherically-deposited materials. In this study, we investigated high resolution carbon (C) accrual and peat decomposition rates at two Sphagnum-rich ombrotrophic bogs and one fen in northern Minnesota, USA by analyzing 1 cm increments from 30 cm thick intact frozen blocks of peat soil. We conducted radiocarbon analysis of Sphagnum cellulose to determine peat age and net C accumulation at each depth interval. Calibrated peat ages were determined using CALIBomb and a compilation of calibration datasets for the pre-bomb period. We fit data with a negative exponential accumulation model and used model-derived parameters to estimate net primary productivity (NPP) and a peat decomposition rate constant k. FTIR spectroscopy and C:N were used to derive humification indices and to chemically characterize the peat. NPP ranged from 180 to 266 g C m -2 year -1 , k ranged from 0.015 to 0.019 year -1 . Net C accumulation rates ranged from 112 to 174 g C m -2 year -1 at 25 years and 70 to 113 g C m -2 year-1 at 50 years. Mass loss was up to 55% during the first 50 years of peat accumulation. Decomposition is greater at depth in the bogs—where 25 cm of peat correspond to 55 years of peat accumulation—than in the fen, where peat age is approximately 25 years at 25 cm depth. Lastly, information on fine-scale variations in peat mass decomposition and loss across ombrotrophic bogs and a fen help interpret other diagenetic processes in peatlands.

54 ENVIRONMENTAL SCIENCES↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

EVALUATING THE CALORIMETER MODEL WITH BROADBAND, CONTINUOUS SPECTRA OF STARBURST GALAXIES OBSERVED WITH THE ALLEN TELESCOPE ARRAY

Although the relationship between the far-infrared and centimeter-wave radio luminosities of normal galaxies is one of the most striking correlations in astronomy, a solid understanding of its physical basis is lacking. In one interpretation, the 'calorimeter model', rapid synchrotron cooling of cosmic ray electrons is essential in reproducing the observed linear relationship. Observed radio spectra, however, are shallower than what is expected of cooled synchrotron emission. In 2006, Thompson et al. presented a simple parameterized model to explain how relatively shallow observed spectra might arise even in the presence of rapid synchrotron cooling by accounting for ionization losses and other cooling mechanisms. During the commissioning of the 42 element Allen Telescope Array (ATA), we observed the starburst galaxies M82, NGC 253, and Arp 220 at frequencies ranging from 1 to 7 GHz, obtaining unprecedented broadband continuous radio spectra of these sources. We combine our observations with high-frequency data from the literature to separate the spectra into thermal and nonthermal components. The nonthermal components all steepen in the centimeter-wave regime and cannot be well modeled as simple power laws. The model of Thompson et al. is consistent with our M82 results when plausible parameters are chosen, and our results in fact significantly shrink the space of allowed model parameters. The model is only marginally consistent with our NGC 253 data. Assuming the Thompson et al. model, a steep electron energy injection index of p = -2.5 is ruled out in M82 and NGC 253 to >99% confidence. We describe in detail the observing procedures, calibration methods, analysis, and consistency checks used for broadband spectral observations with the ATA.

79 ASTRONOMY AND ASTROPHYSICS↗

Is flat fielding safe for precision CCD astronomy?

The ambitious goals of precision cosmology with wide-field optical surveys such as the Dark Energy Survey (DES) and the Large Synoptic Survey Telescope (LSST) demand precision CCD astronomy as their foundation. This in turn requires an understanding of previously uncharacterized sources of systematic error in CCD sensors, many of which manifest themselves as static effective variations in pixel area. Such variation renders a critical assumption behind the traditional procedure of flat fielding—that a sensor's pixels comprise a uniform grid—invalid. In this work, we present a method to infer a curl-free model of a sensor's underlying pixel grid from flat-field images, incorporating the superposition of all electrostatic sensor effects—both known and unknown—present in flat-field data. We use these pixel grid models to estimate the overall impact of sensor systematics on photometry, astrometry, and PSF shape measurements in a representative sensor from the Dark Energy Camera (DECam) and a prototype LSST sensor. Applying the method to DECam data recovers known significant sensor effects for which corrections are currently being developed within DES. For an LSST prototype CCD with pixel-response non-uniformity (PRNU) of 0.4%, we find the impact of "improper" flat fielding on these observables is negligible in nominal .7'' seeing conditions. Furthermore, these errors scale linearly with the PRNU, so for future LSST production sensors, which may have larger PRNU, our method provides a way to assess whether pixel-level calibration beyond flat fielding will be required.

79 ASTRONOMY AND ASTROPHYSICS↗

Solar neutrino measurements in Super-Kamiokande-IV

We report that upgraded electronics, improved water system dynamics, better calibration and analysis techniques allowed Super-Kamiokande-IV to clearly observe very low-energy B 8 solar neutrino interactions, with recoil electron kinetic energies as low as ~ 3.5 MeV . Super-Kamiokande-IV data-taking began in September of 2008; this paper includes data until February 2014, a total livetime of 1664 days. The measured solar neutrino flux is ( 2.308 ± 0.020 ( stat ) - 0.040 + 0.039 ( syst ) ) × 1 0 6 / ( cm 2 sec ) assuming no oscillations. The observed recoil electron energy spectrum is consistent with no distortions due to neutrino oscillations. An extended maximum likelihood fit to the amplitude of the expected solar zenith angle variation of the neutrino-electron elastic scattering rate in SK-IV results in a day/night asymmetry of ( - 3.6 ± 1.6 ( stat ) ± 0.6 ( syst ) ) % . The SK-IV solar neutrino data determine the solar mixing angle as sin 2 θ 12 = 0.327 - 0.031 + 0.026 , all SK solar data (SK-I, SK-II, SK III and SK-IV) measures this angle to be sin 2 θ 12 = 0.334 - 0.023 + 0.027 , the determined mass-squared splitting is Δ m 21 2 = 4.8 - 0.8 + 1.5 × 10 - 5 eV 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real time computer data system for the 40 x 80 ft wind tunnel facility at Ames Research Center

The wind tunnel realtime computer system is a distributed data gathering system that features a master computer subsystem, a high speed data gathering subsystem, a quick look dynamic analysis and vibration control subsystem, an analog recording back-up subsystem, a pulse code modulation (PCM) on-board subsystem, a communications subsystem, and a transducer excitation and calibration subsystem. The subsystems are married to the master computer through an executive software system and standard hardware and FORTRAN software interfaces. The executive software system has four basic software routines. These are the playback, setup, record, and monitor routines. The standard hardware interfaces along with the software interfaces provide the system with the capability of adapting to new environments.

Cambra, J. M.↗

Applications of Landsat imagery to a coastal inlet stability study

Polcyn and Lyzenga (1975) and Middleton and Barber (1976) have demonstrated that it is possible to correlate the radiance values of a multispectral imagery, such as Landsat imagery, with the depth related information. The present study is one more example of such an effort. Two sets of Landsat magnetic tape were obtained and displayed on the screen of an Image-100 computer. Spectral analysis was performed to produce various signatures, their extent, and location. Subsequent ground truth observations and measurements were gathered by means of hydrographic surveys and low altitude aerial photographs for interpretation and calibration of the Landsat data. Finally, a coastal engineering assessment based on the Landsat data was made. Recommendations regarding the navigational canal alignment and dredging practice are presented in the light of inlet stability.

Wang, Y.-H.↗

Oceanography from space

Active and passive spaceborne instruments that can observe the sea are discussed. Attention is given to satellite observations of ocean surface temperature and heating, wind speed and direction, ocean currents, wave height, ocean color, and sea ice. Specific measurements now being made from space are described, the accuracy of various instruments is considered, and problems associated with the analysis of satellite data are examined. It is concluded that the satellites and techniques used by different nations should be sufficiently standard that data from one satellite can be directly compared with data from another and that accurate calibration and overlap of satellite data are necessary to confirm the continuity and homogeneity of the data.

Stewart, R. H.↗

High temperature stress-strain analysis

The objectives of the high temperature structures program are threefold: to assist in the development of analytical tools needed to improve design analysis and procedures for the efficient and accurate prediction of the nonlinear structural response of hot-section components; to aid in the calibration, validation, and evaluation of the analytical tools by comparing predictions with experimental data; and to evaluate existing as well as advanced temperature and strain measurement instrumentation.

Thompson, Robert L.↗

Spectral Characterizations of the Clouds and the Earth's Radiant Energy System (CERES) Thermistor Bolometers using Fourier Transform Spectrometer (FTS) Techniques

Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.

Thornhill, K. Lee↗

NASA Tech Briefs, December 2006

Topic include: Inferring Gear Damage from Oil-Debris and Vibration Data; Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs; User Interactive Software for Analysis of Human Physiological Data; Representation of Serendipitous Scientific Data; Automatic Locking of Laser Frequency to an Absorption Peak; Self-Passivating Lithium/Solid Electrolyte/Iodine Cells; Four-Quadrant Analog Multipliers Using G4-FETs; Noise Source for Calibrating a Microwave Polarimeter; Hybrid Deployable Foam Antennas and Reflectors; Coating MCPs with AlN and GaN; Domed, 40-cm-Diameter Ion Optics for an Ion Thruster; Gesture-Controlled Interfaces for Self-Service Machines; Dynamically Alterable Arrays of Polymorphic Data Types; Identifying Trends in Deep Space Network Monitor Data; Predicting Lifetime of a Thermomechanically Loaded Component; Partial Automation of Requirements Tracing; Automated Synthesis of Architecture of Avionic Systems; SSRL Emergency Response Shore Tool; Wholly Aromatic Ether-Imides as n-Type Semiconductors; Carbon-Nanotube-Carpet Heat-Transfer Pads; Pulse-Flow Microencapsulation System; Automated Low-Gravitation Facility Would Make Optical Fibers; Alignment Cube with One Diffractive Face; Graphite Composite Booms with Integral Hinges; Tool for Sampling Permafrost on a Remote Planet; and Special Semaphore Scheme for UHF Spacecraft Communications.

Source record↗

Application of Ensemble Detection and Analysis to Modeling Uncertainty in Non Stationary Process

Characterization of non stationary and nonlinear processes is a challenge in many engineering and scientific disciplines. Climate change modeling and projection, retrieving information from Doppler measurements of hydrometeors, and modeling calibration architectures and algorithms in microwave radiometers are example applications that can benefit from improvements in the modeling and analysis of non stationary processes. Analyses of measured signals have traditionally been limited to a single measurement series. Ensemble Detection is a technique whereby mixing calibrated noise produces an ensemble measurement set. The collection of ensemble data sets enables new methods for analyzing random signals and offers powerful new approaches to studying and analyzing non stationary processes. Derived information contained in the dynamic stochastic moments of a process will enable many novel applications.

Racette, Paul↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Investigation of SiPM physics parameters down to cryogenic temperatures and for a bio-medical application

Silicon PhotoMultiplier (SiPM) detector has become a suitable visible light/photon detector for many applications like high energy physics and neutrino experiments, fluorescence detection, bio-photonics and medical imaging. The first part of my thesis was oriented to the studies of SiPM physics parameters as a function of temperature. Particularly, recent KETEK devices (year 2015) with different technological characteristics like p/n and n/p junctions, with and without trench technology, and different widths of epitaxial layer were studied in the temperature range from 308.15 K (+35°C) down to 238.15 K (-35°C). In addition, the Hamamatsu devices from 2011 production run as well as new devices from 2015 year, with improved technological characteristics inducing a reduced noise, were investigated in a wider temperature range from 318.15 K (+45°C) down to 98.15 K (-175°C). For these purposes, I participated to the design, installation, commissioning and calibration of a cryogenic experimental setup dedicated to electrical, optical and temperature studies of SiPM devices. Also, I have developed an automatic analysis procedure able to handle in a short time an impressive quantity of experimental data (i.e. tens of Gb/device) and to give a precise and fast information on main SiPM parameters and their temperature dependence. I have also developed a physical modeldescribing the DC I-V curves of SiPM detectors at different temperatures. The proposed model fits well the shape of IV curve in a very large currents range from 10⁻¹² A up to 10⁻⁵ A over the full working range of various devices. Consequently, the IV model can be used as a simple and fast method for determination of SiPM parameters like breakdown voltage VBD, the shape of Geiger triggering probability PGeiger as a function of Vbias as well as the Vbias working range. The comparison of these parameters with those calculated from AC measurements and analyzed by the automatic procedure showed a good agreement. The second part of my thesis was oriented to the study of SiPM devices and their physical parameters required to build a prototype of betasensitive intracerebral probe. Such probe is dedicated to measure the local concentration of radiolabeled molecules on awake and freely moving animal and to study new animal models of human disorders (neurodegenerative diseases, tumor growth, and neuropsychiatric disorders). It is composed of small size, low-noise SiPM device coupled to a scintillating fiber and readout by a dedicated miniaturized low-power consumption electronics. Three SiPM devices have been chosen as the most adapted for our application: two small KETEK devices of 0.5×0.5 mm² size (with and without optical trenches, specially developed by KETEK to fulfill our requirements) and a standard Hamamatsu device of 1.3×1.3 mm² size, all devices having 50 × 50 μm² μcell size. For each SiPM the gain G, dark count rate DCR and beta sensitivity were measured as a function of Vbias and temperature. The obtained results showed that the small field of view and newly developed structure of the KETEK devices allow a large decrease of the dark count rate DCR. However, this small field of view also leads to a reduced light collection due to the thickness of the epoxy protection resin on top of the SiPM and the acceptance angle of the fiber. Since the beta sensitivity represents a tradeoff between photon detection efficiency PDE and dark count rate DCR, KETEK SiPMs exhibit similar performances in comparison with the Hamamatsu device. Preliminary results demonstrate that the beta sensitivity of KETEK devices can be significantly improved by using focusing lens between the scintillating fiber and the SiPM or by reducing the thickness of its epoxy protection resin.

Nagai, Andrii↗