Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Stability and Activity of (Pr 1‐x Nd x ) 2 NiO 4 as Cathodes for Solid Oxide Fuel Cells: I. Quantification of Phase Evolution in Pr 2 NiO 4

Praseodymium nickelate (Pr 2 NiO 4 ) is an active oxygen electrode for solid oxide fuel cells, but undergoes phase transition at elevated temperatures (e.g., 750°C). Quantification of this phase evolution in an operating single cell is challenging because of the overlap of X‐ray diffraction ( XRD ) peaks between the cathode and oxide current collector. In this work, we replace the oxide current collector with a gold metal grid, circumventing these challenges by allowing the exposure of the cathode to the X‐ray beam, while eliminating peak overlap. Quantification of the phase evolution was performed by a least‐squares fitting of the linear combination of XRD standards against the experimental patterns. Energy‐dispersive spectroscopy analysis on long‐term operated cells showed the absence of reactions between the gold grids and the cathodes. Additionally, the grids exhibited excellent mechanical stability under operating conditions and enabled similar cell performance as an oxide current collector.

Dogdibegovic, Emir↗

Validation and benchmarking of two particle-in-cell codes for a glow discharge

The two particle-in-cell codes EDIPIC and LSP are benchmarked and validated for a parallel-plate glow discharge in helium, in which the axial electric field had been carefully measured, primarily to investigate and improve the fidelity of their collision models. The scattering anisotropy of electron-impact ionization, as well as the value of the secondary-electron emission yield, are not well known in this case. The experimental uncertainty for the emission yield corresponds to a factor of two variation in the cathode current. If the emission yield is tuned to make the cathode current computed by each code match the experiment, the computed electric fields are in excellent agreement with each other, and within about 10% of the experimental value. The non-monotonic variation of the width of the cathode fa ll with the applied voltage seen in the experiment is reproduced by both codes. The electron temperature in the negative glow is within experimental error bars for both codes, but the density of slow trapped electrons is underestimated. A more detailed code comparison don e for several synthetic cases of electron-beam injection into helium gas shows that the codes are in excellent agreement for ionization rate, as well as for elastic and excitation collisions with isotropic scattering pattern. The remaining significant discrepancies between the two codes are due to differences in their electron binary-collision models, and for anisotropic scattering due to elastic and excitation collisions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micrometer-accuracy 2D displacement interferometer with plasmonic metasurface resonators

In this Letter, a high-accuracy, two-dimensional displacement sensor is proposed, designed, and demonstrated based on the concept of an extrinsic Fabry–Perot Interferometer. The sensor is composed of two bundled single-mode optic fibers in parallel and two plasmonic metasurface resonators inscribed on a gold substrate via a focused ion beam. The fiber end surface and the metasurface are in parallel with a small cavity between. The cavity change or Z -component displacement is determined from the pattern of interference fringes. The X -component displacement, perpendicular to the Z component, is identified from wavelength-selective metasurface resonators, which possess unique resonant wavelengths due to different nanostructure designs. The sensor was calibrated with six displacements applied through a three-axis precision linear stage. Test results indicated that the proposed interferometer can measure displacements with a maximum error of 5.4 µm or 2.2%.

Guo, Chuanrui (ORCID:0000000271412972)↗

Split in phase singularities of an optical vortex by off-axis diffraction through a simple circular aperture

Here, diffraction patterns of an optical vortex through several shaped apertures reveal its topological charge. In this letter, we theoretically and experimentally show that diffraction of a Laguerre Gaussian beam through a circular aperture at an off-axis position can be used to determine the magnitude and sign of the topological charge. To our knowledge, this is the first time that a simple circular aperture has been used to detect orbital angular momentum of an incident optical vortex.

43 PARTICLE ACCELERATORS↗

Shock Damage Analysis in Serial Femtosecond Crystallography Data Collected at MHz X-ray Free-Electron Lasers

Serial femtosecond crystallography (SFX) data were recorded at the European X-ray free-electron laser facility (EuXFEL) with protein microcrystals delivered via a microscopic liquid jet. An XFEL beam striking such a jet may launch supersonic shock waves up the jet, compromising the oncoming sample. To investigate this efficiently, we employed a novel XFEL pulse pattern to nominally expose the sample to between zero and four shock waves before being probed. Analyzing hit rate, indexing rate, and resolution for diffraction data recorded at MHz pulse rates, we found no evidence of damage. Notably, however, this conclusion could only be drawn after careful identification and assimilation of numerous interrelated experimental factors, which we describe in detail. Failure to do so would have led to an erroneous conclusion. Femtosecond photography of the sample-carrying jet revealed critically different jet behavior from that of all homogeneous liquid jets studied to date in this manner.

36 MATERIALS SCIENCE↗

Ultraviolet interferometer

Grazing-incidence multi-beam interferometer /GIMBI/ obtains high resolution spectroscopic data from ultraviolet region of the spectrum without use of concave diffraction gratings or partially reflecting coatings. Device produces interference pattern whose fringes may be sharper than those produced by a Fabry-Perot interferometer.

Day, R. A.↗

Laser furnace technology for zone refining

A carbon dioxide laser experiment facility is constructed to investigate the problems in using a laser beam to zone refine semiconductor and metal crystals. The hardware includes a computer to control scan mirrors and stepper motors to provide a variety of melt zone patterns. The equipment and its operating procedures are described.

Griner, D. B.↗

Analysis of a generalized dual reflector antenna system using physical optics

Reflector antennas are widely used in communication satellite systems because they provide high gain at low cost. Offset-fed single paraboloids and dual reflector offset Cassegrain and Gregorian antennas with multiple focal region feeds provide a simple, blockage-free means of forming multiple, shaped, and isolated beams with low sidelobes. Such antennas are applicable to communications satellite frequency reuse systems and earth stations requiring access to several satellites. While the single offset paraboloid has been the most extensively used configuration for the satellite multiple-beam antenna, the trend toward large apertures requiring minimum scanned beam degradation over the field of view 18 degrees for full earth coverage from geostationary orbit may lead to impractically long focal length and large feed arrays. Dual reflector antennas offer packaging advantages and more degrees of design freedom to improve beam scanning and cross-polarization properties. The Cassegrain and Gregorian antennas are the most commonly used dual reflector antennas. A computer program for calculating the secondary pattern and directivity of a generalized dual reflector antenna system was developed and implemented at LeRC. The theoretical foundation for this program is based on the use of physical optics methodology for describing the induced currents on the sub-reflector and main reflector. The resulting induced currents on the main reflector are integrated to obtain the antenna far-zone electric fields. The computer program is verified with other physical optics programs and with measured antenna patterns. The comparison shows good agreement in far-field sidelobe reproduction and directivity.

Acosta, Roberto J.↗

Localized growth of InAs quantum dots on nanopatterned InP(001) substrates

We present the method of site-controlled growth of InAs quantum dots on InP(001) by solid-source molecular beam epitaxy. InAs dots are positioned using nanopatterns realized by electron beam lithography and dry etching. We have obtained the localized InAs dots for InAs deposit thickness inferior to the critical thickness for the two-dimensional/three-dimensional growth mode transition measured on a flat InP surface, implying that the dots can be actively positioned at predefined nucleation sites. Photoluminescence results show the emission of localized InAs dots on patterns overgrown with a thin InP buffer layer, at a wavelength around 1.5 {mu}m at room temperature.

36 MATERIALS SCIENCE↗

Initial clinical evaluation of PET-based ion beam therapy monitoring under consideration of organ motion

Purpose: Intrafractional organ motion imposes considerable challenges to scanned ion beam therapy and demands for a thorough verification of the applied treatment. At the Heidelberg Ion-Beam Therapy Center (HIT), the scanned ion beam delivery is verified by means of postirradiation positron-emission-tomography (PET) imaging. This work presents a first clinical evaluation of PET-based treatment monitoring in ion beam therapy under consideration of target motion. Methods: Three patients with mobile liver lesions underwent scanned carbon ion irradiation at HIT and postirradiation PET/CT (x-ray-computed-tomography) imaging with a commercial scanner. Respiratory motion was recorded during irradiation and subsequent image acquisition. This enabled a time-resolved (4D) calculation of the expected irradiation-induced activity pattern and, for one patient where an additional 4D CT was acquired at the PET/CT scanner after treatment, a motion-compensated PET image reconstruction. For the other patients, PET data were reconstructed statically. To verify the treatment, calculated prediction and reconstructed measurement were compared with a focus on the ion beam range. Results: Results in the current three patients suggest that for motion amplitudes in the order of 2 mm there is no benefit from incorporating respiratory motion information into PET-based treatment monitoring. For a target motion in the order of 10 mm, motion-related effects become more severe and a time-resolved modeling of the expected activity distribution can lead to an improved data interpretation if a sufficient number of true coincidences is detected. Benefits from motion-compensated PET image reconstruction could not be shown conclusively at the current stage. Conclusions: The feasibility of clinical PET-based treatment verification under consideration of organ motion has been shown for the first time. Improvements in noise-robust 4D PET image reconstruction are deemed necessary to enhance the clinical potential.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of electron beam irradiation on CrMnV and CrMnTiV high entropy alloys: Nano-mechanical, structural, and thermodynamic perspectives

Beam exit windows are crucial components of any particle accelerator as they provide an interface between the beamline vacuum and target material at atmospheric media. For high beam power machines, special materials and designs are required to withstand high radiation and mechanical loads, while minimizing energy loss during transition and maximizing window lifetime. This research investigates the impact of electron beam exposure to bulk CrMnV and CrMnTiV high entropy alloys (HEAs) with the primary goal of identifying suitable candidate materials for the design of robust and durable exit window settings. The selection criteria include intrinsic characteristics, power dissipation, and mechanical responses. According to the thermodynamic calculations, both equiatomic CrMnV and the addition of 7% of Ti with equiatomic CrMnV yield solid-solutions phases. The structural and mechanical properties of CrMnV and CrMnTiV samples were tested using field emission scanning electron microscopy, atomic force microscopy, scanning electron microcopy with energy dispersive x-ray spectroscopy, x-ray diffraction, and nanoindentation before and after exposure to a dose of ~66 kGy from a 10 MeV e-beam accelerator. Despite exhibiting beam transmission characteristics comparable to Cr and V, the indentation hardness of HEAs exceeded that of the Cr and V samples by five to six times. The examination of the CrMnTiV irradiated samples revealed organized deformation patterns depicting new features, which we suspect twinning and twin boundaries due to the addition of Ti to CrMnV. Ti, a hexagonal-close-packed crystal structure, is commonly known for deformation twinning behavior.

36 MATERIALS SCIENCE↗

SU-G-TeP2-04: Comprehensive Machine Isocenter Evaluation with Separation of Gantry, Collimator, and Table Variables

Purpose: To develop and demonstrate application of a method that characterizes deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter as a function of gantry, collimator, and table variables. Methods: A set of Winston-Lutz ball-bearing images was used to determine the gantry radiation isocenter as the midrange of deviation values resulting from gantry and collimator rotation. Also determined were displacement of table axis from gantry isocenter and recommended table axis adjustment. The method, previously reported, has been extended to include the effect of collimator walkout by obtaining measurements with 0 and 180 degree collimator rotation for each gantry angle. Twelve images were used to characterize the volumetric isocenter for the full range of available gantry, collimator, and table rotations. Results: Three Varian True Beam, two Elekta Infinity and four Versa HD linacs at five institutions were tested using identical methodology. Varian linacs exhibited substantially less deviation due to head sag than Elekta linacs (0.4 mm vs. 1.2 mm on average). One linac from each manufacturer had additional isocenter deviation of 0.3 to 0.4 mm due to jaw instability with gantry and collimator rotation. For all linacs, the achievable isocenter tolerance was dependent on adjustment of collimator position offset, transverse position steering, and alignment of the table axis with gantry isocenter, facilitated by these test results. The pattern and magnitude of table axis wobble vs. table angle was reproducible and unique to each machine. Conclusion: This new method provides a comprehensive set of isocenter deviation values including all variables. It effectively facilitates minimization of deviation between beam center and target (ball-bearing) position. This method was used to quantify the effect of jaw instability on isocenter deviation and to identify the offending jaw. The test is suitable for incorporation into a routine machine QA program. Software development was performed by Radiological Imaging Technology, Inc.

60 APPLIED LIFE SCIENCES↗

Model study of the energy dependence of the correlation between anisotropic flow and the mean transverse momentum in Au + Au collisions

A hybrid model that employs the hadron-string transport model UrQMD and the (3+1)-dimensional relativistic viscous hydrodynamic code vHLLE, is used to investigate the beam energy dependence of the correlation coefficient ρ(v$^{2}_{2}$,[p T ]) between the average transverse momentum [p T ] of hadrons emitted in an event and the square of the anisotropic flow coefficient v$^{2}_{2}$. For Au+Au collisions, the model predicts characteristic patterns for the energy and event-shape dependence of the variances for [p T ] and v$^{2}_{n}$ [Var([p T ] and Var(v$^{2}_{2}$)], and the covariance of v$^{2}_{n}$ and [p T ][cov(v$^{2}_{2}$,[p T ])], consistent with the attenuation effects of the specific shear viscosity η/s. Here in contrast, ρ(v$^{2}_{2}$,[p T ]) is predicted to be insensitive to the beam energy but sensitive to the initial-state geometry of the collisions. These observations suggest that a precise set of measurements for Var([p T ]), Var(v$^{2}_{2}$), cov(v$^{2}_{2}$,[p T ]) and ρ(v$^{2}_{2}$,[p T ]) as a function of beam energy and event shape, could serve to constrain better the eccentricities and their fluctuations over the entire span of beam energies, and consequently aid precision extraction of the temperature and baryon chemical-potential dependence of η/s from the wealth of Au+Au data obtained in the RHIC beam energy scan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

D-25 OBSERVATIONS OF SHOCKED METALLIC SURFACES WITH SINGLE-PULSE X-RAY DIFFRACTION

A single-pulse x-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line and bremsstrahlung x-ray emission in a 40-ns pulse. A selected anode of either silver or molybdenum produces characteristic K lines used for diffraction. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2-mm by 5-mm spot and 1° full-width-half-maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock-loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{beta} decay of the {pi}f{sub 5/2} ground state of {sup 77}Cu studied with 225 MeV and 0.2 MeV purified radioactive beams

Isobarically purified beams of {sup 77}Cu with energies of 225 and 0.2 MeV were used at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory to study {beta} decay into states in {sup 77}Zn. Data taken at 225 MeV allowed the determination of absolute branching ratios relative to the decay of {sup 77}Cu for this {beta} decay as well as its daughters. From these we obtained a refined {beta}-delayed neutron emission probability of 30.3(22)% and a probability that the decay proceeds through {sup 77}Zn{sup g} of 49.1(26)%. A total of 64 {gamma} rays were placed in a level scheme for {sup 77}Zn containing 35 excited states including one state above the neutron separation energy, whereas two {gamma} rays were observed for the {beta}n branch to states in {sup 76}Zn. The growth and decay curves of some prominent {gamma} rays indicate a single {beta}-decaying state with a half-life of 480(9) ms. The decay pattern for {sup 77}Cu, with observed feeding of 8(3)% to 7/2{sup +} {sup 77}Zn{sup g} and 6(3)% to 1/2{sup -} {sup 77}Zn{sup m}, in contrast to the large feeding observed for decay of {pi}p{sub 3/2} {sup 73}Cu{sup g} to 1/2{sup -} {sup 73}Zn{sup g}, strongly suggests a {pi}f{sub 5/2} ground state for the studied {sup 77}Cu activity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fundamental Proximity Effects in Focused electron Beam Induced Deposition

Fundamental proximity effects for electron beam induced deposition processes on nonflat surfaces were studied experimentally and via simulation. Two specific effects were elucidated and exploited to considerably increase the volumetric growth rate of this nanoscale direct write method: (1) increasing the scanning electron pitch to the scale of the lateral electron straggle increased the volumetric growth rate by 250% by enhancing the effective forward scattered, backscattered, and secondary electron coefficients as well as by strong recollection effects of adjacent features; and (2) strategic patterning sequences are introduced to reduce precursor depletion effects which increase volumetric growth rates by more than 90%, demonstrating the strong influence of patterning parameters on the final performance of this powerful direct write technique.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Determination of the thickness and spectral dependence of the refractive index of Al{sub x}In{sub 1-x}Sb epitaxial layers from reflectance spectra

A nondestructive method for measuring the thicknesses of epitaxial layers of Al{sub x}In{sub 1-x}Sb alloys based on interference effects in reflectance spectra measured in a wide wavelength range (1-28 {mu}m) is implemented. The studied 0.9-3.3 {mu}m thick Al{sub x}In{sub 1-x}Sb layers are grown on highly lattice-mismatched GaAs substrates by molecular beam epitaxy. The found thicknesses are in good agreement with the independent data of scanning electron microscopy. The spectral dependence of the refractive index n(E) of Al{sub x}In{sub 1-x}Sb layers is measured both for the regions of transparency and fundamental absorption. The refractive index for the case of E < E{sub 0} was calculated by a double-oscillator model using a refined experimental dependence of the band gap on the composition E{sub 0}(x). The experimental data on the n(E) of Al{sub x}In{sub 1-x}Sb for energies E > E{sub 0} are found based on the interference pattern.

36 MATERIALS SCIENCE↗