Search NASASearch

SEARCH · Search NASA

Results for “Astronomy and AstroPhysics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,176 records · Page 98

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke

A Missed Thrust Framework for Low-Thrust Spiral Trajectories to the NRHO

A framework is developed by which end-to-end optimization of many-revolution low-thrust spiral trajectories can be completed in the presence of missed thrust events. This framework is applied to the Lunar Transit trajectory by which the initial capability of NASA’s Gateway lunar space station will be delivered to a Near Rectilinear Halo Orbit. This low-thrust mission consists of three subphases, each designed according to the specific objectives and dynamical regimes encountered as the mission progresses from a medium Earth insertion orbit to cislunar space. The presented framework accounts for the unique considerations demanded by each mission phase and incorporates appropriate capabilities into a novel mission analysis tool. This methodology enables large scale and reliable analyses of missed thrust events across the end-to-end Lunar Transit to verify the robustness of flight trajectories across the full range of considered launch dates.

missed thrust

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING

A Novel Approach to Investigate Thermal Protection Systems Materials

The Koo Research Group (KRG) at The University of Texas at Austin (UT) and KAI has specialized in “Ablation Research” for more than fifteen years. Recently, the group has developed several incredibly unique capabilities that can advance “Thermal Protection Systems (TPS) Materials Research & Development” using an integrated experimental and numerical approach. The paper aims to introduce the methodology KRG has developed to solve this challenging problem. It will discuss how the KRG develops “Process-Properties-Performance” relationships of novel TPS materials in a systematical approach using (a) processing and fabrication, (b) thermal characterization of properties, (c) aerothermal testing, (d) microstructures characterization and analysis, and (e) numerical modeling. Progress and challenges of this research will also be discussed.

Engineering

Environmental drivers of spatial variation in tropical forest canopy height: Insights from NASA’s GEDI spaceborne LiDAR

Forest canopy height is a fundamental ecosystem property—influencing patterns of forest carbon storage and forest ecosystem responses to climate variability and change. Previous studies have analyzed environmental drivers influencing spatial variation in canopy height at landscape-to-regional scales; however, far less is known about the environmental determinants underlying regional and global scale variation in forest canopy height. Using the canopy height metrics products from Global Ecosystem Dynamics Investigation (GEDI), a space-borne Light Detection and Ranging (LiDAR) instrument specifically designed to characterize forest structure, we analyze the environmental correlates of spatial variation of global tropical forest canopy height. Our study demonstrates that climate, topography, and soil properties account for 75% of the variation in tropical forest canopy height. Elevation, dry season length, and solar radiation are the most important drivers in determining canopy height both locally and regionally. These results emphasize the vulnerability of tropical forest structure to ongoing changes in the earth’s climate and provide a valuable empirical baseline for tropical forest management.

Science & Technology - Other Topics

Turbofan Engine Power Extraction Demonstration Final Report

As GE Aerospace advances toward a revolutionary step change in propulsion efficiency, the integration and demonstration of new engine architectures and technology systems are essential. The NASA Turbofan Engine Power Extraction Demonstration (PEx), conducted through the Hybrid Thermally Efficient Core (HyTEC) project, aims to develop and demonstrate megawatt-class hybrid electric capability on a modern commercial turbofan engine. The hybrid electric system is critical to meeting the needs of the U.S. aviation industry for next-generational propulsion systems with greater efficiency, durability, and range. This supports energy independence and helps ensure the security and resilience of one of America's largest export industries. The PEx project specifically targets three key objectives: mechanically integrating hybrid electric capability into a commercial turbofan engine, integrating electric machine control with turbofan control for advanced power management, and de-risking performance modeling of future hybrid electric architectures. To mature these technologies to Technology Readiness Level (TRL) 6, a series of electric power system component tests and a baseline engine performance test campaign were conducted. These efforts culminated in an integrated hybrid electric turbofan test campaign demonstrating power extraction, power insertion, and power transfer between spools. Tests of the electric power system were completed at GE Aerospace’s Electrical Power Integrated Systems Center in Dayton, Ohio and engine tests were completed at Peebles Test Operation in Peebles, Ohio. Hybrid electric trade studies extended the demonstrated capability to altitude using the validated cycle model from the PEx test campaigns, allowing for comments on expanded mission benefits not demonstrated in the ground campaign. The knowledge gained from PEx also supports GE Aerospace’s Compact Core Demonstrator as part of HyTEC Phase 2 and ultimately informs the implementation of hybrid electric systems in the next generation of GE Aerospace commercial engine products. This report provides a summary of the program background, test campaigns, trade studies, and insights into the technical maturation required to support future commercial products.

Hybrid Electric

Application of Energy-efficient Electromagnetic Melt-Processing for the Upcycling of Recycled Polyphenylene Sulfide into Multifunctional Segregated Nanocomposites

Polyphenylene sulfide (PPS) is widely used in structural and functional composites because of its thermal stability, chemical resistance, and mechanical strength. As circular manufacturing becomes increasingly important, extending the service life of recycled PPS (rPPS) is essential. However, conventional high-temperature reprocessing accelerates thermo-oxidative degradation, reducing recycled composite performance. This study proposes a rapid and potentially energy-saving upcycling strategy for rPPS using electromagnetic (EM) melt-processing to form segregated carbon nanotube (CNT) networks and produce EM-responsive nanocomposites. The aim was to determine whether CNT-assisted EM heating could reduce polymer degradation while improving multifunctional properties at ultralow filler loadings. rPPS micropellets were coated with CNTs by ball milling to create conductive shells, then compacted into green bodies (GBs) and selectively melted by rapid EM irradiation. Structural, electrical, mechanical, rheological, and electromagnetic interference (EMI) shielding properties were evaluated. Electrical percolation occurred at an ultralow CNT loading of 0.08 wt%, with conductivity reaching (1.24 ± 0.74) × 10 -5 S⋅m -1 at 0.1 wt%. At this concentration, tensile strength and modulus increased by 72% and 99%, respectively. At ~ 0.7 mm thickness, X-band EMI shielding effectiveness reached 6 dB for GBs and 3 dB after EM processing. This shows that EM melt-processing upcycles rPPS into high-performance multifunctional nanocomposites with minimum thermal degradation.

recycled

Pressure Safety Training (Rev. 8)

This is the workbook for the Pressure Safety Training Course. It is intended as a reference manual and guide for all work with pressurized liquids or gases. This workbook contains basic references to make work with pressure safer. It is intended to supplement classroom instruction, rather than serve as a definitive text on pressure. Earlier versions of the manual were intended specifically for training at Lawrence Livermore National Laboratory. This revision is a generic version intended for training at all DOE facilities. The information in the Standards chapter is from the LLNL Health and Safety Manual. It is included here as a convenient reference and guide for developing similar standards at your own facility.

42 ENGINEERING

Cully Community Solar

This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.

14 SOLAR ENERGY

Development of large-scale, 3D Printed high temperature ceramic material

Through this collaborative effort, a new 3D printing platform for ceramics called laser-induced slip casting (LIS) was explored and developed for improving the processing and manufacture of silicon carbide (SiC), a high temperature ceramic material. This method prints layers of ceramic slips/slurries with subsequent selective-laser heating to dry each layer to build a 3D structure. The completed and dried part is then sintered. This manufacturing process is inherently lower cost than alternative ceramic printing methods such as binder jet technology or stereolithography when it comes to the feedstock material but is more expensive than robocasting or direct ink writing. However, it has the potential to make more controlled parts with less defects compared to robocasting. The largest cost is the heating source for the printer. With this technique, there is potential to make large ceramic parts in a near-net shape. Further, there is no known commercial manufacturing of 3D printed ceramics that creates a large range of different high-density ceramics at large scale. The goals and outcomes for the development of the new printing technology were: 1) assessing the technology with alumina by characterizing coupons, 2) printing and sintering of silicon carbide (SiC), and 3) characterization and properties testing of materials printed and a scale-up of SiC part(s). Through this collaborative project, it was sought to provide the best solution to achieving highly dense and near-net shaped ceramic parts at large scale and reduced cost. The goal was to produce high density sintered materials for applications in defense, energy generating systems, armor, and wear parts using 3D printing methods. Variables including powder particle sizes, dispersant molecular weights (MWs), binders, printing parameters, and post processing were explored as well as the characterization of the physical properties (add specifics here).

36 MATERIALS SCIENCE

Acute Exposure to Aerosolized Nanoplastics Modulates Redox-Linked Immune Responses in Human Airway Epithelium

Micro- and nanoplastics (MPs and NPs) are pervasive environmental pollutants detected in aquatic ecosystems, with emerging evidence suggesting their presence in airborne particles generated by water body motion. Inhalation exposure to airborne MPs and NPs remains understudied despite documented links between occupational exposure to these particles and adverse respiratory outcomes, including airway inflammation, oxidative stress, and chronic respiratory diseases. This study explored the effects of acute NP exposure on a fully differentiated 3D human airway epithelial model derived from 14 healthy donors. Airway epithelium was exposed to aerosolized 50 nm polystyrene NPs at concentrations ranging from 2.5 to 2500 µg/mL for three minutes per day over three days. Functional assays revealed no significant alterations in tissue integrity, cell survival, mucociliary clearance, or cilia beat frequency, suggesting intact epithelial function post-exposure. However, cytokine and chemokine profiling identified a significant five-fold increase in CCL3 (MIP-1α), a neutrophilic chemoattractant, in NP-exposed samples compared to controls. This was corroborated by increased neutrophil chemotaxis in response to conditioned media from NP-exposed tissues, indicating a pro-inflammatory neutrophilic response. Conversely, levels of interleukins (IL-21, IL-2, IL-15), CXCL10, and TGF-β were significantly reduced, suggesting immunomodulatory effects that may impair adaptive immune responses and tissue repair mechanisms. These findings demonstrate that short-term exposure to NP-containing aerosols induces a distinct pro-inflammatory response in airway epithelium, characterized by enhanced neutrophil recruitment and reduced secretion of key immune modulators. These findings underscore the potential for aerosolized NPs to induce oxidative and inflammatory stress, raising concerns about their long-term impact on respiratory health and redox regulation.

Biochemistry & Molecular Biology

The Significance of Water Vapor Isotopes in Improving Weather Prediction

Water vapor isotopes carry the integrated history of evaporation, condensation, mixing, and transport. Although previous studies have shown potential to improve forecasts under controlled conditions, real-world applications have been limited by systematic biases in both models and satellite retrievals arising from sparse measurements in the free troposphere. Here we assimilate mid‑tropospheric δD retrievals (peak sensitivity ~4.2 km) from the Infrared Atmospheric Sounding Interferometer into the Isotope‑incorporated Global Spectral Model and evaluate the added value beyond co‑assimilated temperature and specific humidity with identical spatial and temporal coverage. Assimilating δD improves 0–120 h forecasts of wind, temperature, specific humidity, and geopotential height, with the largest gains in the midlatitudes; heavy‑precipitation skill also increases for thresholds >3 mm per 6 h. Demonstrated in a coarse‑resolution configuration with limited observations, the results indicate that isotopic information strengthens transport tracking and hydrological constraints, motivating evaluation in operational high‑resolution forecasting systems.

Hydrology

Adventures in Research: A History of Ames Research Center, 1940-1965

The present document, which I have called a history-though it certainly was not written for historians-was prepared for and at the request of the NASA Ames Research Center which, in sponsoring the project, acted with the encouragement of NASA Headquarters. It is an account of the establishment, evolutionary development, and activities of the Ames Research Center covering a period characterized by unprecedented scientific and technological revolution. The writing of this book about the Ames Research Center was undertaken with considerable pleasure by one who for many years was employed by the Center’s parent organization NASA and, before that, NACA; who had closely followed the Center’s growth from the beginning; and who was personally acquainted with, and who held in some affection, the members of its founding staff. These facts are given to alert readers to the presence of bias and the inaccuracies stemming therefrom. It should be emphasized that this work is a history only of the Ames Research Center. It is not a history of the U.S. Government, of NACA or NASA, of other research centers, of the military services, of industry, or of world events. Information on these peripheral subjects is introduced merely to provide the reader with a generalized feeling for the local and world environment in which the formation and subsequent activities of the Ames Research Center took place. The background material provided is notably incomplete and in some instances reveals the bias of the NACA/NASA community at the time the events took place. Frequently, also, it reflects the personalized viewpoint of the author who was a close observer of many of these events.

NASA Center History Series

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

An Ultra-long Life, High-performance, Flexible Li-CO2Battery Based on Multifunctional Carbon Electrocatalysts

Integrating CO2 utilization and renewable energy delivery/storage, the rechargeable Li–CO2 battery has been considered as a promising candidate for next-generation secondary batteries. However, high-performance catalyst(s) for efficient formation and decomposition of the discharge product, Li2CO3, are an imperative part of a Li–CO2 battery. The development of flexible Li–CO2 batteries extends their applications into compliant and wearable devices/systems, but at the same time imposes a big challenge for battery fabrication and lifetime enhancement. In this study, a rechargeable quasi-solidus flexible Li–CO2 battery was designed and fabricated using highly active N,S-doped carbon nanotubes (N,S-doped CNTs) as the cathode catalyst, and a smart polymer gel as the flexible electrolyte. This newly-developed flexible Li–CO2 battery exhibited a capacity as high as 23560 mAh g−1 based on the catalyst mass and an ultra-long lifetime of up to 538 cycles with excellent mechanical flexibility. This work provides a platform for the design and development of high-performance flexible Li–CO2 batteries from low-cost, earth-abundant, carbon-based multifunctional cathode catalysts.

Superior stability

Air Force Phillips Laboratory Battery Program overview

Battery development and testing efforts at Phillips Laboratory fall into three main categories: nickel hydrogen, sodium sulfur, and solid state batteries. Nickel hydrogen work is broken down into a Low Earth Orbit (LEO) Life Test Program, a LEO Pulse Test Program, and a Hydrogen Embrittlement Investigation. Sodium sulfur work is broken down into a Geosynchronous Earth Orbit (GEO) Battery Flight Test and a Hot Launch Evaluation. Solid state polymer battery work consists of a GEO Battery Development Program, a Pulse Power Battery Small Business Innovation Research (SBIR), and an in-house evaluation of current generation laboratory cells. An overview of the program is presented.

House, Shaun

Space Nuclear Propulsion for Space Applications: Multi-Mission Nuclear Thermal Propulsion Vehicle Design

This NASA Technical Memorandum (TM) is intended to capture design work that the Advanced Concepts Office (ACO) at NASA’s Marshall Space Flight Center (MSFC) performed on behalf of the Space Nuclear Propulsion (SNP) Project during an SNP-driven design and mission analysis initiative in FY2025. Specifically, this TM focuses on several spacecraft design concepts intended to explore the feasibility of nuclear thermal propulsion (NTP) for use in a selection of notional, unmanned space missions. While references to the missions will be made in this TM, the primary focus will be on the spacecraft design concepts themselves, the ground rules and assumptions used for designing the spacecraft, a description of the various subsystems and their performance parameters, and the methodologies used to design them. The TM will also highlight areas of future work and additional considerations that may need to be taken into account when evaluating the feasibility of NTP space systems for other applications. The report will discuss the results from ACO’s analysis as they pertain to the different vehicle concepts that were evaluated. Each discipline section in this report will discuss the discipline-specific ground rules and assumptions, the methodology and design approaches employed, and present the results along with any relevant discussion, and highlight areas of future work where applicable.

Mitchell A Rodriguez