Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETORESISTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable Reset Behavior in Domain Wall–Magnetic Tunnel Junction Artificial Neurons for Task-Adaptable Computation

Neuromorphic computing with spintronic devices has been of interest due to the limitations of CMOS-driven von Neumann computing. Domain wall–magnetic tunnel junction (DW-MTJ) devices have been shown to be able to intrinsically capture biological neuron behavior. Edgy-relaxed behavior, where a frequently firing neuron experiences a lower action potential threshold, may provide additional artificial neuronal functionality when executing repeated tasks. In this letter, we demonstrate that this behavior can be implemented in DW-MTJ artificial neurons via three alternative mechanisms: shape anisotropy, magnetic field, and current-driven soft reset. Using micromagnetics and analytical device modeling to classify the Optdigits handwritten digit dataset, we show that edgy-relaxed behavior improves both classification accuracy and classification rate for ordered datasets while sacrificing little to no accuracy for a randomized dataset. This letter establishes methods by which artificial spintronic neurons can be flexibly adapted to datasets.

42 ENGINEERING↗

Low temperature grown polycrystalline La{sub 0.7}Sr{sub 0.3}MnO{sub 3} thin films on amorphous SiO{sub 2} substrates by rf magnetron sputtering

The La{sub 0.7}Sr{sub 0.3}MnO{sub 3} thin films have been prepared on amorphous SiO{sub 2} substrates by a rf magnetron sputtering technique under various oxygen flow rates and rf powers at a relatively low substrate temperature of 350 deg. C. The effects of oxygen flow rate and rf power on their physical properties were systematically investigated. X-ray diffraction results show that the growth orientation and crystallinity of the films were affected by rf power and oxygen flow rate. The electrical resistivity of the films was reduced with increasing oxygen flow rate and rf power due to enhanced {l_brace}100{r_brace} growth plane orientation and enlarged grain size of the films. In addition, a relatively high temperature coefficient of resistance value of -2.4% was obtained in the present investigation even with low deposition temperature.

36 MATERIALS SCIENCE↗

SU-E-T-24: A Simple Correction-Based Method for Independent Monitor Unit (MU) Verification in Monte Carlo (MC) Lung SBRT Plans

Purpose: Lung-SBRT uses hypo-fractionated dose in small non-IMRT fields with tissue-heterogeneity corrected plans. An independent MU verification is mandatory for safe and effective delivery of the treatment plan. This report compares planned MU obtained from iPlan-XVM-Calgorithm against spreadsheet-based hand-calculation using most commonly used simple TMR-based method. Methods: Treatment plans of 15 patients who underwent for MC-based lung-SBRT to 50Gy in 5 fractions for PTV V100%=95% were studied. ITV was delineated on MIP images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1- 106.5cc(average=48.6cc). MC-SBRT plans were generated using a combination of non-coplanar conformal arcs/beams using iPlan XVM-Calgorithm (BrainLAB iPlan ver.4.1.2) for Novalis-TX consisting of micro-MLCs and 6MV-SRS (1000MU/min) beam. These plans were re-computed using heterogeneity-corrected Pencil-Beam (PB-hete) algorithm without changing any beam parameters, such as MLCs/MUs. Dose-ratio: PB-hete/MC gave beam-by-beam inhomogeneity-correction-factors (ICFs):Individual Correction. For independent-2nd-check, MC-MUs were verified using TMR-based hand-calculation and obtained an average ICF:Average Correction, whereas TMR-based hand-calculation systematically underestimated MC-MUs by ∼5%. Also, first 10 MC-plans were verified with an ion-chamber measurement using homogenous phantom. Results: For both beams/arcs, mean PB-hete dose was systematically overestimated by 5.5±2.6% and mean hand-calculated MU systematic underestimated by 5.5±2.5% compared to XVMC. With individual correction, mean hand-calculated MUs matched with XVMC by - 0.3±1.4%/0.4±1.4 for beams/arcs, respectively. After average 5% correction, hand-calculated MUs matched with XVMC by 0.5±2.5%/0.6±2.0% for beams/arcs, respectively. Smaller dependence on tumor volume(TV)/field size(FS) was also observed. Ion-chamber measurement was within ±3.0%. Conclusion: PB-hete overestimates dose to lung tumor relative to XVMC. XVMC-algorithm is much more-complex and accurate with tissues-heterogeneities. Measurement at machine is time consuming and need extra resources; also direct measurement of dose for heterogeneous treatment plans is not clinically practiced, yet. This simple correction-based method was very helpful for independent-2nd-check of MC-lung-SBRT plans and routinely used in our clinic. A look-up table can be generated to include TV/FS dependence in ICFs.

60 APPLIED LIFE SCIENCES↗

SU-E-T-438: Commissioning of An In-Vivo Quality Assurance Method Using the Electronic Portal Imaging Device

Purpose: Patient specific pre-treatment quality assurance (QA) using arrays of detectors or film have been the standard approach to assure the correct treatment is delivered to the patient. This QA approach is expensive, labor intensive and does not guarantee or document that all remaining fractions were treated properly. The purpose of this abstract is to commission and evaluate the performance of a commercially available in-vivo QA software using the electronic portal imaging device (EPID) to record the daily treatments. Methods: The platform EPIgray V2.0.2 (Dosisoft), which machine model compares ratios of TMR with EPID signal to predict dose was commissioned for an Artiste (Siemens Oncology Care Systems) and a Truebeam (Varian medical systems) linear accelerator following the given instructions. The systems were then tested on three different phantoms (homogeneous stack of solid water, anthropomorphic head and pelvis) and on a library of patient cases. Simple and complex fields were delivered at different exposures and for different gantry angles. The effects of the table attenuation and the EPID sagging were evaluated. Gamma analysis of the measured dose was compared to the predicted dose for complex clinical IMRT cases. Results: Commissioning of the EPIgray system for two photon energies took 8 hours. The difference between the dose planned and the dose measured with EPIgray was better than 3% for all phantom scenarios tested. Preliminary results on patients demonstrate an accuracy of 5% is achievable in high dose regions for both 3DCRT and IMRT. Large discrepancies (>5%) were observed due to metallic structures or air cavities and in low dose areas. Flat panel sagging was visible and accounted for in the EPIgray model. Conclusion: The accuracy achieved by EPIgray is sufficient to document the safe delivery of complex IMRT treatments. Future work will evaluate EPIgray for VMAT and high dose rate deliveries. This work is supported by Dosisoft, Cachan, France.

60 APPLIED LIFE SCIENCES↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-06: A Water Calorimeter for Use in MRI Linacs

Purpose: At VSL, Dutch Metrology Institute, a new water calorimeter was developed with the purpose to replace the existing primary standard for absorbed dose to water in the Netherlands. The new water calorimeter is designed to be operable in medium- to high energy photon beams, electrons, protons as well as MRI integrated linear accelerators. VSL has operated a water calorimeter since 2001. This calorimeter formed the basis for the NCS-18 dosimetry protocol, which is commonly applied by medical physicists in the Netherlands and Belgium. Methods: The unit Gray is the unit of interest for measurement of the absorbed dose to water. Water calorimetry involves the measurement of a small temperature rise (0.24 mK/Gy) with an uncertainty of less than 1 μK/Gy at a temperature of 4 °C. Using extensive multi-physics simulations the new calorimeter's thermal performance was simulated before it was constructed at the end of 2013. With the advent of radiotherapy treatment units incorporating MR imaging the performance of the thermistor temperature sensors were characterized in a 1.5 T magnetic field. Results: A change of thermistor resistance was observed of less than 0.004% as a Result of the magneto-resistance effect in a 1.5 T magnetic field. Although a magneto-resistance effect was detectable, the effect on the temperature response in the water calorimeter was found to be negligible. Conclusion: With the realization of the new calorimeter operable in MRI linacs and designed for use in a variety of beam modalities, VSL is ready for accurate dosimetry in new advanced radiotherapy modalities. Due to the small form factor the calorimeter can be used on location in the actual therapy beam inside a 68 cm linac bore. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

60 APPLIED LIFE SCIENCES↗

SU-F-J-108: TMR Correction Factor Based Online Adaptive Radiotherapy for Stereotactic Radiosurgery (SRS) of L-Spine Tumors Using Cone Beam CT

Purpose: To investigate the feasibility of using TMR ratio correction factors for a fast online adaptive plan to compensate for anatomical changes in stereotactic radiosurgery (SRS) of L-spine tumors. Methods: Three coplanar treatment plans were made for 11 patients: Uniform (9 IMRT beams equally distributed around the patient); Posterior (IMRT with 9 posterior beams every 20 degree) and VMAT (2 360° arcs). For each patient, the external body and bowel gas were contoured on the planning CT and pre-treatment CBCT. After registering CBCT and the planning CT by aligning to the tumor, the CBCT contours were transferred to the planning CT. To estimate the actual delivered dose while considering patient’s anatomy of the treatment day, a hybrid CT was created by overriding densities in planning CT using the differences between CT and CBCT external and bowel gas contours. Correction factors (CF) were calculated using the effective depth information obtained from the planning system using the hybrid CT: CF = TMR (delivery)/TMR (planning). The adaptive plan was generated by multiplying the planned Monitor Units with the CFs. Results: The mean absolute difference (MAD) in V16Gy of the target between planned and estimated delivery with and without TMR correction was 0.8 ± 0.7% vs. 2.4 ± 1.3% for Uniform and 1.0 ± 0.9% vs. 2.6 ± 1.3% for VMAT plans(p<0.05), respectively. For V12Gy of cauda-equina with and without TMR correction, MAD was 0.24 ± 0.19% vs. 1.2 ± 1.02% for Uniform and 0.23 ± 0.20% vs. 0.78 ± 0.79% for VMAT plans(p<0.05), respectively. The differences between adaptive and original plans were not significant for posterior plans. Conclusion: The online adaptive strategy using TMR ratios and pre-treatment CBCT information was feasible strategy to compensate for anatomical changes for the patients treated for L-spine tumors, particularly for equally spaced IMRT and VMAT plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-555: Accurate Stereotactic Cone TMRs Converted from PDDs Scanned with Ray Trace

Purpose: To investigate whether the accuracy of TMRs for stereotactic cones converted from PDDs scanned with Ray Trace can be improved, when compared against the TMRs converted from the traditional PDDs. Methods: Ray Trace measurement in Sun Nuclear 3D Scanner is for accurate scan of small field PDDs. The system detects the center of field at two depths, for example, at 3 and 20 cm in our study, and then performs scan along the line passing the two centers. With both Ray Trace and the traditional method, PDDs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac, using Edge detectors. The formalism of converting PDD to TMR given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring cone Scp and Sc. Continuous direct measurement of TMR by filling/draining water to/from the tank and spot measurement by moving the tank and detector were also performed with the same equipment, using 100 cm SDD. Results: For 6XFFF energy and all the cones, TMRs converted from Ray Trace were very close to the continuous and spot measurement, while TMRs converted from traditional PDDs had larger deviation. Along the central axis beyond dmax, 1.7% of TMR data points calculated from Ray Trace had more 3% deviation from measurement, with maximal deviation of 5.2%. Whereas, 34% of TMR points calculated from traditional PDDs had more than 3% deviation, with maximum of 5.7%. In this initial study, Ray Trace scans for 10XFFF beam were noisy, further measurement is warranted. Conclusion: The Ray Trace could improve the accuracy of PDDs measurement and the calculated TMRs for stereotactic cones, which was within 3% of the measured TMRs.

60 APPLIED LIFE SCIENCES↗

Role of scaffold network in controlling strain and functionalities of nanocomposite films

One novel approach to manipulating functionalities in correlated complex oxides is strain. However, significant epitaxial strain can only be achieved in ultrathin layers. We show that, under direct lattice matching framework, large and uniform vertical strain up to 2% can be achieved to significantly modify the magnetic anisotropy, magnetism, and magnetotransport properties in heteroepitaxial nanoscaffold films, over a few hundred nanometers in thickness. Comprehensive designing principles of large vertical strain have been proposed. Phase-field simulations not only reveal the strain distribution but also suggest that the ultimate strain is related to the vertical interfacial area and interfacial dislocation density. Moreover, by changing the nanoscaffold density and dimension, the strain and the magnetic properties can be tuned. The established correlation among the vertical interface—strain—properties in nanoscaffold films can consequently be used to tune other functionalities in a broad range of complex oxide films far beyond critical thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of Rashba Spin-Orbit Coupling on the Anisotropic Magneto Resistance in Domain Wall

The present paper, based on semi-classical Boltzmann equation, aims to investigate the effects of Rashba and Dresselhaus spin orbit interaction and impurities on domain wall anisotropic magneto resistance. It has been shown that the mentioned effects play a remarkable role in anisotropic magneto resistance of electron current in domain walls. It was also concluded that while an increase in Rashba coupling strength can effectively enhance anisotropic magneto resistance of the domain wall, an increase in the wave-vector and exchange interaction leads to their decrease.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic and Magnetodielectric Properties of Ho{sub 0.5}Nd{sub 0.5}Fe{sub 3}(BO{sub 3}){sub 4}

The magnetic and magnetodielectric properties of Ho{sub 0.5}Nd{sub 0.5}Fe{sub 3}(BO{sub 3}){sub 4} ferroborate with the competing Ho–Fe and Nd–Fe exchange couplings have been experimentally and theoretically investigated. Step anomalies in the magnetization curves at the spin-reorientation transition induced by the magnetic field B ║ c have been found. The spontaneous spin-reorientation transition temperature T{sub SR} ≈ 8 K has been refined. The measured magnetic properties and observed features are interpreted using a single theoretical approach based on the molecular field approximation and calculations within the crystal field model of the rare-earth ion. Interpretation of the experimental data includes determination of the crystal field parameters for Ho{sup 3+} and Nd{sup 3+} ions in Ho{sub 0.5}Nd{sub 0.5}Fe{sub 3}(BO{sub 3}){sub 4} and parameters of the Ho–Fe and Nd–Fe exchange couplings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Giant Magneto-Resistance in Epitaxial (La 0.7 Sr 0.3 MnO 3 ) 0.5 : (ZnO) 0.5 Nanocomposites

A great deal of research has been carried out in oxide material systems. Among them, ZnO and La 0.7 Sr 0.3 MnO 3 (LSMO) are of particular interest due to their superb optical properties and colossal magneto-resistive effect. Here, we report our recent results of magneto-transport studies in self-assembled, epitaxial (ZnO)0.5:(La 0.7 Sr 0.3 MnO 3 ) 0.5 nanocomposite films.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Final report

Conductivity and Magnetism in Strongly Coupled Quantum Dot Solids. One outcome of the project is the discovery of a rather universal 1/f noise magnitude in electrical transport across nanocrystals. The noise is extensive in the number of dots in the device, and inversely proportional to the interdot resistance. The other outcome is a study of the magneto-resistance of light and heavy doped chalcogenides semiconductor quantum dots with Manganese. Strong MR was observed at low temperature in n-doped Mn doped quantum dot films, and this was attributed to the formation of magnetic polarons.

1/f noise↗

Final CRADA Report for Enhanced and Miniaturized Wireless Valve Position Indicator Prototype

Most operating nuclear power plants (NPPs) in the United States have received approval to extend their operating licenses to 60 years. Now the nuclear industry is preparing to extend operating licenses to 80 years. While NPPs are preparing for extensions (60 years and beyond), the nuclear industry is facing a unique economic sustainability challenge in the current energy market. According to the Nuclear Energy Institute (NEI), generating costs of U.S. reactors have risen by 28% over the last 12 years, which is impacting the competitiveness of nuclear power in a market being increasingly penetrated by natural gas and renewable energy. This is partly because of the fact that the present nuclear work practice is dependent on a large technical staff which results in high operation and maintenance (O&M) costs, accounting for approximately 66% of the total operating cost. To address these concerns and abide by the NEI’s “Delivering the Nuclear Promise Initiative,” the U.S. utilities are embracing digitalization of their work practice to lower the O&M costs and increase productivity and efficiency while maintaining a safe and reliable operation. To address these above-mentioned concerns, Idaho National Laboratory (INL) researchers (proposal team) have developed a wireless valve position indication (VPI) sensor system that can be retrofitted on three main manual valve types (extendible to other manual valve types) to replace manual valve position verification with digital verification and enable online monitoring of manual valves. The developed technology 1) is evaluated for electromagnetic interference, 2) has a low power consuming and miniaturized electronic board, 3) is mounted on adjustable and reconfigurable sensor mounting unit that can fit on an actual flow-loop (at Idaho State University-ISU) to enable online monitoring of manual valve types without any valve body modification, and 4) ensures robust, secure, and reliable real-time communication of manual valve position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗