Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Imaging in Diagnostic Nuclear Medicine

Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are modern methods for visualization in diagnostic nuclear medicine. SPECT is known as a workhorse in cardiology, and PET is the gold standard in oncology. The development of nuclear medicine is provided by cooperation of physicists, mathematicians, biologists, medical doctors, and radio-chemists. In spite of extensive clinical applications, several problems may lead to false diagnoses. In particular, the correction of attenuation of gamma radiation in human organs must be taken into account. For interpretation and evaluation of such an effect on the clinical results, we perform physico-mathematical simulation of the SPECT diagnostics in cardiology in the absence and presence of the correction of attenuation. A brief review of the state-of-the art is presented. The simulation employs the first Russian anthropomorphic mathematical phantom that describes the distribution of radio-pharmacological agent ({sup 99m }Tc-methoxyisobutylisonitrile) in chest organs of a typical male patient. A model for calculation of raw images is developed with allowance for attenuation of radiation in biological tissues and the effect of collimator and detector. The results of the proposed models and calculated images are compared with clinical images obtained at the Meshalkin Institute of Circulation Pathology (Novosibirsk) and Myasnikov Institute of Clinical Cardiology (Moscow). Statistical algorithms are developed for the solution of the inverse problem of image reconstruction based on the entropy principle. The clinical and physico-mathematical approaches are compared in the evaluation of the effect of correction on the quality of reconstructed images of the left ventricle of myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hardening of DOE UQ Codes for Ultra-Deep Proactive Geosteering in Oilfield Service

The primary objective of this project was to harden the DOE uncertainty quantification (UQ) code to solve the inverse problem for the geosteering service in the oilfield drilling and exploration. The primary focus is to verify the feasibility of using QUESO to solve geosteering inverse problems through statistical inversion. QUESO is a software library developed by QUEST, a DOE's Scientific Discovery through Advanced Computing (SciDAC) institute. In the process of drilling a borehole, geosteering is the act of adjusting the well trajectory on the fly to reach the geological targets or to keep the wellbore within desired formation. Geosteering inversion is to infer underground formation structure using measurements such as azimuthal resistivity logging data. The geosteering process relies on the real-time reconstruction of the subsurface earth model, and a robust and efficient inversion algorithm is always necessary to satisfy the job requirement. The new generation of azimuthal resistivity geosteering tool is capable of detecting multiple formation boundaries 20-100 ft away, and the corresponding geosteering inversion problem can be very challenging as many parameters need to be inverted within such a large depth of investigation. The success of the project will support US energy security by helping to advance subsurface modeling and characterization technologies in oilfield applications. An effective subsurface inversion algorithm and the implementation as a software package will promote the usage of ultra-deep azimuthal resistivity measurements, which can help well placement in complicated underground environments, reduce costs and risks of drilling, and increase oil and gas production. It will help medium and small size independent service companies and tool manufactures to enter the more advanced and lucrative directional drilling area. In addition, by hardening the QUESO code and building a transparent interface for easy manipulation of the QUESO functions, we provide a user-friendly tool for a larger scientific and industry communities that rely heavily on modeling and simulation tools for forecasting, parameter studies, design, and decision making. These are all activities that can strongly benefit from meaningful representations of modeling uncertainty supported by our product.

58 GEOSCIENCES↗

Enabling Explosives and Contraband Detection

We present the design and performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20-30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8 0.5% of the true value. Finally, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5-10% level for a two hour scan time. Experimental performance was evaluated with various thicknesses of polyethylene. The detector response in terms of energy, particle identification, and timing are presented as well.

42 ENGINEERING↗

A spectroscopic search for colliding stellar winds in O-type close binary systems. IV - Iota Orionis

We present H-alpha and He I 6678 A line profiles for the eccentric orbit binary Iota Ori. We have applied a tomography algorithm which uses the established orbital velocity curves and intensity ratio to reconstruct the spectral line profiles for each star. The He I profiles appear as pure photospheric lines, and H-alpha shows variable emission in the line core throughout the orbit (which is typical of O giants) and in the blue wing near periastron passage. We show that the blue wing emission is consistent with an origin between the stars which probably results from a dramatic focusing of the primary's stellar wind at periastron. We also present IUE archival spectra of the UV wind lines N V 1240 A and C IV 1550 A.

Gies, Douglas R.↗

Synthetic-Aperture Coherent Imaging From A Circular Path

Imaging algorithms based on exact point-target responses. Developed for use in reconstructing image of target from data gathered by radar, sonar, or other transmitting/receiving coherent-signal sensory apparatus following circular observation path around target. Potential applications include: Wide-beam synthetic-aperture radar (SAR) from aboard spacecraft in circular orbit around target planet; SAR from aboard airplane flying circular course at constant elevation around central ground point, toward which spotlight radar beam pointed; Ultrasonic reflection tomography in medical setting, using one transducer moving in circle around patient or else multiple transducers at fixed positions on circle around patient; and Sonar imaging of sea floor to high resolution, without need for large sensory apparatus.

Jin, Michael Y.↗

3D Geolocation of Simulated Lightning Sources from Low-Earth Orbit

The recent removal of the Lightning Imaging Sensor from the International Space Station has left an observational gap in lightning detection from low-Earth orbit (LEO). However, new studies have demonstrated the potential for 3D geolocation of lightning sources using orbiting sensors. The Cubespark mission concept aims to take advantage of these developments by deploying a constellation of satellites with radio frequency (RF) sensors and optical imagers to not only map lightning locations, but also to collect bi-spectral flash images. These new capabilities include mapping storm charge structure, flash channel structure, and distinguishing microphysical processes throughout flash development, helping link microphysics and convective processes with overall flash and storm structure around the globe from LEO. In this study, we simulate lightning RF sources in the very high frequency (VHF) band, extrapolate their signals to space-based detection using an improved ionospheric model, and reconstruct their 3D locations using a time-of-arrival (TOA) minimization algorithm. Various constellation configurations, locations, and atmospheric conditions are considered in order to identify and quantify the three main sources of geolocation error: geometric, ionospheric, and instrumental effects. The promising results of this study emphasize the potential of space-based 3D lightning mapping under diverse conditions. 3D resolution is shown to be better than 1-2 km in many cases, enabling new global applications in meteorology and climate sciences. Here we present a selection of these geolocation results as seen from space alongside recent advancements, paving the way for a future generation of LEO lightning mappers.

CubeSpark↗

Atmospheric PSF Interpolation for Weak Lensing in Short Exposure Imaging Data

A main science goal for the Large Synoptic Survey Telescope (LSST) is to measure the cosmic shear signal from weak lensing to extreme accuracy. One difficulty, however, is that with the short exposure time ({approx_equal}15 seconds) proposed, the spatial variation of the Point Spread Function (PSF) shapes may be dominated by the atmosphere, in addition to optics errors. While optics errors mainly cause the PSF to vary on angular scales similar or larger than a single CCD sensor, the atmosphere generates stochastic structures on a wide range of angular scales. It thus becomes a challenge to infer the multi-scale, complex atmospheric PSF patterns by interpolating the sparsely sampled stars in the field. In this paper we present a new method, psfent, for interpolating the PSF shape parameters, based on reconstructing underlying shape parameter maps with a multi-scale maximum entropy algorithm. We demonstrate, using images from the LSST Photon Simulator, the performance of our approach relative to a 5th-order polynomial fit (representing the current standard) and a simple boxcar smoothing technique. Quantitatively, psfent predicts more accurate PSF models in all scenarios and the residual PSF errors are spatially less correlated. This improvement in PSF interpolation leads to a factor of 3.5 lower systematic errors in the shear power spectrum on scales smaller than {approx} 13, compared to polynomial fitting. We estimate that with psfent and for stellar densities greater than {approx_equal}1/arcmin{sup 2}, the spurious shear correlation from PSF interpolation, after combining a complete 10-year dataset from LSST, is lower than the corresponding statistical uncertainties on the cosmic shear power spectrum, even under a conservative scenario.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy reconstruction in a highly granularity semi-digital hadronic calorimeter

A semi-digital hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) is one of the calorimeters candidates proposed for particle physics experiments at the future electrons collider. It is a high granular calorimeter which is required for application of the particle flow algorithm in order to improve the jet energy resolution as one of the goals of this experiments. We discussed the energy reconstruction, based on digital and semi-Digital methods, to study the effect on the improvement of the single particle energy resolution and the linearity of the detector response. This study was performed with the GEANT4 simulation. Results on the energy resolution and linearity, for negative pions over an energy range from 1 to 100 GeV are presented and compared with different energy reconstruction methods including Artificial Neural Networks. (authors)

43 PARTICLE ACCELERATORS↗

hdsullivan/ResSR

This is the official implementation of ResSR [1]. ResSR is a computationally efficient MSI-SR method that achieves high-quality reconstructions by using a closed-form spectral decomposition along with a spatial residual correction. ResSR applies singular value decomposition to identify correlations across spectral bands, uses pixel-wise computation to upsample the MSI, and then applies a residual correction process to correct the high-spatial frequency components of the upsampled bands. While ResSR is formulated as the solution to a spatially-coupled optimization problem, we use pixel-wise regularization and derive an approximate closed-form solution, resulting in a pixel-wise algorithm with a dramatic reduction in computation that achieves state-of-the-art reconstructions. [1] Duba-Sullivan, H., Reid, E. J., Voisin, S., Bouman, C. A., & Buzzard, G. T. (2024). ResSR: A Computationally Efficient Residual Approach to Super-Resolving Multispectral Images. arXiv preprint arXiv:2408.13225.

Duba-Sullivan, Haley [Oak Ridge National Laborator↗

Implementation of a real-time MSE system

Motional Stark effect polarimetry is a key diagnostic for plasma fusion research since its usage on PBX-M. The MSE diagnostic measures the radial magnetic pitch angle profile in a plasma from a neutral beam by observation of Stark split D-alpha emission from atoms excited by collision with ions and electrons in the plasma. The pitch angle measurement is used with equilibrium reconstruction codes to determine the q-profile for studies of plasma stability, confinement, and transport. Historically, the algorithm was used in a post-processing fashion. The goal of our work was to apply this method in real time and pass the results to the plasma control system computer for real-time equilibrium reconstruction and control.

Instruments & Instrumentation↗

On three-dimensional reconstruction of a neutron/x-ray source from very few two-dimensional projections

The neutron imaging system at the National Ignition Facility is an important diagnostic tool for measuring the two-dimensional size and shape of the source of neutrons produced in the burning deuterium-tritium plasma during the stagnation phase of inertial confinement fusion implosions. Very few two-dimensional projections of neutron images are available to reconstruct the three-dimensional neutron source. In this paper, we present a technique that has been developed for the 3D reconstruction of neutron and x-ray sources from a minimal number of 2D projections. We present the detailed algorithms used for this characterization and the results of reconstructed sources from experimental data collected at Omega.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization

Purpose: The streak artifacts caused by metal implants have long been recognized as a problem that limits various applications of CT imaging. In this work, the authors propose an iterative metal artifact reduction algorithm based on constrained optimization. Methods: After the shape and location of metal objects in the image domain is determined automatically by the binary metal identification algorithm and the segmentation of ''metal shadows'' in projection domain is done, constrained optimization is used for image reconstruction. It minimizes a predefined function that reflects a priori knowledge of the image, subject to the constraint that the estimated projection data are within a specified tolerance of the available metal-shadow-excluded projection data, with image non-negativity enforced. The minimization problem is solved through the alternation of projection-onto-convex-sets and the steepest gradient descent of the objective function. The constrained optimization algorithm is evaluated with a penalized smoothness objective. Results: The study shows that the proposed method is capable of significantly reducing metal artifacts, suppressing noise, and improving soft-tissue visibility. It outperforms the FBP-type methods and ART and EM methods and yields artifacts-free images. Conclusions: Constrained optimization is an effective way to deal with CT reconstruction with embedded metal objects. Although the method is presented in the context of metal artifacts, it is applicable to general ''missing data'' image reconstruction problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dimensionality Reduction Algorithms for Big Nuclear Data Streams with Application to SCALE Cross Sections

A central problem in performing accurate nuclear reactor simulations is the ability to capture the changes in the few group microscopic cross sections as functions of system state, e.g. moderator density, fuel temperature, or neutron spectrum, and time and/or burnup of the fuel. For most reactor simulation scenarios, this results in huge data stream, which must be interpolated as needed by downstream calculations (e.g., core-wide simulation). This is typically accomplished by using sophisticated interpolating functions to capture the few-group variations over the wide range of conditions expected during operation. To address handling this big data, this paper explores the use of dimensionality reduction (DR) techniques to identify the true dimensionality of the data prior to its use in the calculations. This could significantly reduce the computational cost required for data processing/manipulation, thus reducing a significant portion of the total calculations time. By way of an example, in the current version of the ORIGEN-ARP module, the assembly-averaged microscopic cross sections at different conditions, e.g., fuel enrichments, irradiation history and water density, which are calculated using the TRITON sequence and interpolated on-demand by the ARP module to model assembly depletion for a wide range of assembly types (e.g. Westinghouse 17x17 and GE 9x9) over a wide range of conditions. This approach typically results in ∼1 GB per assembly type, which although not insurmountable, can be impractical for distribution. and it is the premise of this paper that most of this data is heavily correlated and hence can take great benefit of condensation via DR. To demonstrate DR, the proposed algorithm is applied to the nuclear data streams generated by SCALE 6.1. Using the depletion sequence (TRITON), microscopic cross sections are calculated for a mixed oxide (MOX) fuel assembly design at a representative range of fuel enrichments and fuel burnup. In conventional core simulators, multi dimensional interpolation of these cross sections is used to provides neutronics feedback due to local conditions without returning to expensive TRITON calculations for every change. This paper shows that dimensionality reduction can help compress the size of the cross section data without sacrificing the accuracy of their reconstruction at all conditions of interest. This work explores the application of dimensionality reduction algorithms to nuclear data streams typically employed in support of conventional full-core reactor calculations which rely on interpolation of pre-calculated microscopic cross sections. In particular, analysis of the few group MOX cross sections revealed that a large degree of dependencies exist between the few-group cross sections, which can be revealed via range-finding algorithms. Specifically, correlations between different reaction types for the same isotope have been identified, and correlations between different enrichments and correlations across different isotopes have been identified. This paper demonstrates that the reduction errors can be quantified, and they are uncorrelated with the range of variations for the various cross sections. In future work, we will focus on identifying the smallest rank that takes into account all types of correlations across the range of conditions used to model cross section variations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

Quantifying uncertainty for deep learning based forecasting and flow-reconstruction using neural architecture search ensembles

Classical problems in computational physics such as data-driven forecasting and signal reconstruction from sparse sensors have recently seen an explosion in deep neural network (DNN) based algorithmic approaches. However, most DNN models do not provide uncertainty estimates, which are crucial for establishing the trustworthiness of these techniques in downstream decision making tasks and scenarios. In recent years, ensemble-based methods have achieved significant success for the uncertainty quantification in DNNs on a number of benchmark problems. However, their performance on real-world applications remains under-explored. In this work, we present an automated approach to DNN discovery and demonstrate how this may also be utilized for ensemble-based uncertainty quantification. Specifically, we propose the use of a scalable neural and hyperparameter architecture search for discovering an ensemble of DNN models for complex dynamical systems. We highlight how the proposed method not only discovers high-performing neural network ensembles for our tasks, but also quantifies uncertainty seamlessly. This is achieved by using genetic algorithms and Bayesian optimization for sampling the search space of neural network architectures and hyperparameters. Subsequently, a model selection approach is used to identify candidate models for an ensemble set construction. Afterwards, a variance decomposition approach is used to estimate the uncertainty of the predictions from the ensemble. We demonstrate the feasibility of this framework for two tasks — forecasting from historical data and flow reconstruction from sparse sensors for the sea-surface temperature. In conclusion, we demonstrate superior performance from the ensemble in contrast with individual high-performing models and other benchmarks.

Deep ensembles↗

Prediction and compression of lattice QCD data using machine learning algorithms on quantum annealer

We present regression and compression algorithms for lattice QCD data utilizing the efficient binary optimization ability of quantum annealers. In the regression algorithm, we encode the correlation between the input and output variables into a sparse coding machine learning algorithm. The trained correlation pattern is used to predict lattice QCD observables of unseen lattice configurations from other observables measured on the lattice. In the compression algorithm, we define a mapping from lattice QCD data of floating-point numbers to the binary coefficients that closely reconstruct the input data from a set of basis vectors. Since the reconstruction is not exact, the mapping defines a lossy compression, but, a reasonably small number of binary coefficients are able to reconstruct the input vector of lattice QCD data with the reconstruction error much smaller than the statistical fluctuation. In both applications, we use D-Wave quantum annealers to solve the NP-hard binary optimization problems of the machine learning algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking

Purpose: The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowledge.Methods: The system utilizes an emerging marker-less and laser-based active triangulation (AT) sensor that delivers sparse but highly accurate 3D measurements in real-time. These sparse position measurements are registered with a dense reference surface extracted from planning data. Thereby a dense displacement field is recovered, which describes the spatio-temporal 4D deformation of the complete patient body surface, depending on the type and state of respiration. It yields both a reconstruction of the instantaneous patient shape and a high-dimensional respiratory surrogate for respiratory motion tracking. The method is validated on a 4D CT respiration phantom and evaluated on both real data from an AT prototype and synthetic data sampled from dense surface scans acquired with a structured-light scanner.Results: In the experiments, the authors estimated surface motion fields with the proposed algorithm on 256 datasets from 16 subjects and in different respiration states, achieving a mean surface reconstruction accuracy of ±0.23 mm with respect to ground truth data—down from a mean initial surface mismatch of 5.66 mm. The 95th percentile of the local residual mesh-to-mesh distance after registration did not exceed 1.17 mm for any subject. On average, the total runtime of our proof of concept CPU implementation is 2.3 s per frame, outperforming related work substantially.Conclusions: In external beam radiation therapy, the approach holds potential for patient monitoring during treatment using the reconstructed surface, and for motion-compensated dose delivery using the estimated 4D surface motion field in combination with external-internal correlation models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗