Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical processing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Derivation of Mortal Injury Metric for Studies of Rapid Decompression of Depth-Acclimated Physostomous Fish

In 2005 the U.S. Army Corps of Engineers (USACE) began a study to investigate the response of hatchery and run-of-the-river (ROR) juvenile Chinook salmon to the effects of rapid decompression during passage through mainstem Federal Columbia River Power System (FCRPS) Kaplan turbines. In laboratory studies conducted by Pacific Northwest National Laboratory (PNNL) for USACE since 2005, juvenile fish have been exposed to rapid decompression in a barometric pressure chamber. An initial study considered the response of juvenile Chinook salmon bearing radio transmitters to rapid decompression resulting from exposure to a pressure time history simulating the worst case condition that might be experienced during passage through an operating turbine. The study in 2005 found that acclimation depth was a very important treatment factor that greatly influenced the significantly higher incidence of injury and mortality of rapidly decompressed Chinook salmon bearing radio telemetry devices. In 2006 we initiated a statistical investigation using data in hand into derivation of a new end-point measure for assessment of the physiological response of juvenile Chinook salmon to rapid decompression. Our goal was a measure that would more fully utilize both mortality and injury data while providing a better assessment of the most likely survival outcome for juvenile physostomous fish exposed to rapid decompression. The conclusion of the analysis process was to classify fish as mortally injured when any of the 8 injuries are present, regardless of whether the fish was last observed alive or not. The mortally injured classification has replaced mortality as the end point metric for our rapid decompression studies. The process described in this report is an example of how a data set may be analyzed to identify decision criterion for objective classification of test fish to a specific end-point. The resulting list of 8 mortal injuries is applicable to assess injuries from rapid decompression and is currently being applied to ongoing studies. We intend to update this analysis as more data becomes available and to extend it to ROR Chinook salmon smolt. The method itself is applicable to other injury and mortality data for juvenile salmonids from laboratory and field studies related to all dam passage routes and for collision, strike, and shear injuries in addition to decompression.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supporting data for Site-specific Design Case Study for Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels

Hydrothermal liquefaction (HTL) is a thermal process that converts wet biomass to renewable hydrocarbon fuel blendstocks (i.e., renewable naphtha, renewable diesel, and sustainable aviation fuel (SAF)). It can utilize a wide range of pure and blended wet feedstocks, including sewage sludge from water resource recovery facilities (WRRF), food and agriculture wastes, algae, fats, oils and greases (FOG) and blends of dry and wet wastes/feedstocks. Historically, techno-economic analysis (TEA) and annual state of technology (SOT) assessments with standard economic assumptions used by the Bioenergy Technologies Office (BETO) were conducted for the wet waste HTL pathway leveraging experimental data collected from Pacific Northwest National Laboratory’s (PNNL) continuous flow reactor systems. The objective of the SOT assessment has been to guide and track progress of BETO’s HTL research and development (R&D) toward reduced cost and greenhouse gas (GHG) emissions for the pathway. However, gaps exist between BETO’s traditional SOT updates and the needs of key external stakeholders that – if addressed – will accelerate technology adoption. This Business Case Study aims to bridge this gap by providing an updated design, TEA, and LCA based on PNNL’s FY23 R&D with added analyses and information that provide enhanced relevance for stakeholders of the HTL technology. This includes specific siting, regional wet waste resource inventory and transportation cost analyses, fuel market information, sustainable fuel policy impacts, economic metrics of net present value (NPV) and internal rate of return (IRR), greenhouse gas (GHG) emissions analysis, and statistical analysis of cost and technical uncertainties of the HTL plant design. The study focuses on the “Detroit combined statistical area (CSA)” region for siting of a wet waste HTL plant adjacent to the Great Lakes Water Authority (GLWA) facility with guidance from industry participants. Regional resource and siting analyses were conducted to identify feedstock availability, scale, and cost, as well as a beneficial site location. TEA with detailed rigorous capital cost estimation for the specific site application was conducted to evaluate the key economic metrics of most value to industrial partners. These include total capital investment, operating costs, minimum fuel selling price (MFSP) of the biocrude and fuel blendstock, and NPV and internal rate of return IRR with sustainable fuel credits. Life cycle analysis was conducted to evaluate the supply chain greenhouse gas (GHG) emissions for the wet waste HTL process as compared with petroleum derived diesel. This study is also informed by years of R&D and process de-risking learnings and was conducted with a basic engineering HTL plant design and costing that akin to a “first-of-a-kind” plant economics. This differs from our conventional “nth plant ” SOT assessments. Specifically, the HTL process model has been updated with more operationally reliable methods for feed heating and phase separations. Further, we have implemented additional spare equipment for redundancy, a more rigorous installed equipment cost estimation approach, and additional costs associated with feed formatting and delivery, building, piping and site development. An Excel-based cost sheet based on the basic engineering design is also released alongside the report that allows users to conduct customized TEA with their own feed composition and financial assumptions.

Li, Shuyun↗

Shear dynamo, turbulence, and the magnetorotational instability

The formation, evolution, and detailed structure of accretion disks remain poorly understood, with wide implications across a variety of astrophysical disciplines. While the most pressing question – what causes the high angular momentum fluxes that are necessary to explain observations? – is nicely answered by the idea that the disk is turbulent, a more complete grasp of the fundamental processes is necessary to capture the wide variety of behaviors observed in the night sky. This thesis studies the turbulence in ionized accretion disks from a theoretical standpoint, in particular focusing on the generation of magnetic fields in these processes, known as dynamo. Such fields are expected to be enormously important, both by enabling the magnetorotational instability (which evolves into virulent turbulence), and through large-scale structure formation, which may transport angular momentum in different ways and be fundamental for the formation of jets. The central result of this thesis is the suggestion of a new large-scale dynamo mechanism in shear flows – the “magnetic shear-current effect” – which relies on a positive feedback from smallscale magnetic fields. As well as being a very promising candidate for driving field generation in the central regions of accretion disks, this effect is interesting because small-scale magnetic fields have historically been considered to have a negative effect on the large-scale dynamo, damping growth and leading to dire predictions for final saturation amplitudes. Given that small-scale fields are ubiquitous in plasma turbulence above moderate Reynolds numbers, the finding that they could instead have a positive effect in some situations is interesting from a theoretical and practical standpoint. The effect is studied using direct numerical simulation, analytic techniques, and novel statistical simulation methods. In addition to the dynamo, much attention is given to the linear physics of disks and its relevance to turbulence. This is studied using nonmodal stability theory, which both provides a highly intuitive connection between global domains and the commonly studied shearing box, and suggests that transient linear growth can often be more important than spectral instability. These realizations motivate the use of the quasi-linear models that are applied extensively throughout the turbulence and dynamo studies later in the thesis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical simulation of multiple Compton backscattering process

A number of laboratories are currently developing monochromatic sources of X-rays and gamma quanta based on the Compton backscattering (CBS) of laser photons by relativistic electrons. Modern technologies are capable of providing a concentration of electrons and photons in the interaction point such that each primary electron can emit several hard photons. In contrast to the well-known nonlinear CBS process, in which an initial electron “absorbs” a few laser photons and emits a single hard one, the above-mentioned process can be called a multiple CBS process and is characterized by a mean number of emitted photons. The present paper is devoted to simulating the parameters of a beam of back scattered quanta based on the Monte Carlo technique. It is shown that, even in the case of strong collimation of a resulting photon beam, the radiation monochromaticity may deteriorate because of the contribution coming from the multiple photon emission, which is something that must be considered while designing new CBS sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-mass Group Environments Have No Substantial Impact on the Circumgalactic Medium Metallicity

We explore how environment affects the metallicity of the circumgalactic medium (CGM) using 13 low-mass galaxy groups (two to five galaxies) at &lang;z{sub abs}&rang;=0.25 identified near background quasars. Using quasar spectra from the Hubble Space Telescope/COS and from Keck/HIRES or the Very Large Telescope/UVES, we measure column densities of or determine limits on CGM absorption lines. We use a Markov Chain Monte Carlo approach with Cloudy to estimate metallicities of cool (T ~ 10{sup 4} K) CGM gas within groups and compare them to CGM metallicities of 47 isolated galaxies. Both group and isolated CGM metallicities span a wide range (-2 < [Si/H] < 0), where the mean group (-0.54 ± 0.22) and isolated (-0.77 ± 0.14) CGM metallicities are similar. Group and isolated environments have similar distributions of H I column densities as a function of impact parameter. However, contrary to isolated galaxies, we do not find an anticorrelation between H I column density and the nearest group galaxy impact parameter. We additionally divided the groups by member luminosity ratios (i.e., galaxy–galaxy and galaxy–dwarf groups). While there was no significant difference in their mean metallicities, a modest increase in sample size should allow one to statistically identify a higher CGM metallicity in galaxy–dwarf groups compared to galaxy–galaxy groups. We conclude that either environmental effects have not played an important role in the metallicity of the CGM at this stage and expect that this may only occur when galaxies are strongly interacting or merging or that some isolated galaxies have higher CGM metallicities due to past interactions. Thus, environment does not seem to be the cause of the CGM metallicity bimodality.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of reference genes for real-time PCR of cord blood mononuclear cells, differentiating endothelial progenitor cells, and mature endothelial cells

Highlights: • RT-qPCR was used to assess and follow the differentiation of EPCs. • A set of reliable and non-variable genes is key to obtain accurate RT-qPCR results. • The relative gene expression of CD34+ and differentiating endothelial progenitor cells was determined. • The optimal set of reference for the gene expression studies performed by RT-qPCR was determined. In the last ten years, endothelial progenitor cells (EPCs) have gained interest as an attractive cell population in regenerative medicine for vascular applications. This population is defined as the precursor of endothelial mature cells (ECs) through a process of differentiation. To our knowledge, no single marker can be used to discriminate them from mature ECs. To effectively study their differentiation kinetics, gene expression must be assessed. Quantitative real-time PCR (RT-qPCR) is widely used to analyze gene expression. To minimize the impact of variances from RT-qPCR, a rigorous selection of reference genes must be performed prior to any experiments due to variations in experimental conditions. In this study, CD34+ mononuclear cells were extracted from human cord blood and differentiated into EPCs after seeding for a maximum period of 21 days. To choose the best combinations of reference genes, we compared the results of EPCs, CD34+ mononuclear cells, and mature endothelial cells to ensure that the differentiation kinetics did not affect the expression of our selected reference genes. The expression levels of seven genes, namely, YWHAZ, GAPDH, HPRT1, RPLP0, UBC, B2M, and TBP were thus compared. The algorithms geNorm, NormFinder, BestKeeper, and the Comparative ΔCt method were employed to assess the expression of each candidate gene. Overall results reveal that the expression stability of reference genes may differ depending on the statistical program used. YWHAZ, GAPDH, and UBC composed the optimal set of reference genes for the gene expression studies performed by RT-qPCR in our experimental conditions. This work can thus serve as a starting point for the selection of candidate reference genes to normalize the levels of gene expression in endothelial progenitor cell populations.

60 APPLIED LIFE SCIENCES↗

USING THE X-RAY MORPHOLOGY OF YOUNG SUPERNOVA REMNANTS TO CONSTRAIN EXPLOSION TYPE, EJECTA DISTRIBUTION, AND CHEMICAL MIXING

Supernova remnants (SNRs) are a complex class of sources, and their heterogeneous nature has hindered the characterization of their general observational properties. To overcome this challenge, in this paper, we use statistical tools to analyze the Chandra X-ray images of Galactic and Large Magellanic Cloud SNRs. We apply two techniques, a power-ratio method (a multipole expansion) and wavelet-transform analysis, to measure the global and local morphological properties of the X-ray line and thermal emission in 24 SNRs. We find that Type Ia SNRs have statistically more spherical and mirror-symmetric thermal X-ray emission than core-collapse (CC) SNRs. The ability to type SNRs based on thermal emission morphology alone enables, for the first time, the typing of SNRs with weak X-ray lines and those with low-resolution spectra. Based on our analyses, we identify one source (SNR G344.7-0.1) as originating from a CC explosion that was of unknown origin previously; we also confirm the tentative Type Ia classifications of G337.2-0.7 and G272.2-3.2. Although the global morphology is indicative of the explosion type, the relative morphology of the X-ray line emission within SNRs is not: all sources in our sample have well-mixed ejecta, irrespective of stellar origin. In particular, we find that 90% of the bright metal-line-emitting substructures are spatially coincident and have similar scales, even if the metals arise from different burning processes. Moreover, the overall X-ray line morphologies within each SNR are the same, with <6% differences. These findings reinforce observationally that hydrodynamical instabilities can efficiently mix ejecta in Type Ia and CC SNRs. The only exception is W49B, which can be attributed to its jet-driven/bipolar explosive origin. Based on comparative analyses across our sample, we describe several observational constraints that can be used to test hydrodynamical models of SNR evolution; notably, the filling factor of X-ray emission decreases with SNR age.

79 ASTRONOMY AND ASTROPHYSICS↗

Training custom light curve models of SN Ia subpopulations selected according to host galaxy properties

ABSTRACT Type Ia supernova (SN Ia) cosmology analyses include a luminosity step function in their distance standardization process to account for an observed yet unexplained difference in the post-standardization luminosities of SNe Ia originating from different host galaxy populations [e.g. high-mass ($M \gtrsim 10^{10} \, {\rm M}_{\odot }$) versus low-mass galaxies]. We present a novel method for including host-mass correlations in the SALT3 (Spectral Adaptive Light curve Template 3) light curve model used for standardizing SN Ia distances. We split the SALT3 training sample according to host-mass, training independent models for the low- and high-host-mass samples. Our models indicate that there are different average Si ii spectral feature strengths between the two populations, and that the average spectral energy distribution of SNe from low-mass galaxies is bluer than the high-mass counterpart. We then use our trained models to perform an SN cosmology analysis on the 3-yr spectroscopically confirmed Dark Energy Survey SN sample, treating SNe from low- and high-mass host galaxies as separate populations throughout. We find that our mass-split models reduce the Hubble residual scatter in the sample, albeit at a low statistical significance. We do find a reduction in the mass-correlated luminosity step but conclude that this arises from the model-dependent re-definition of the fiducial SN absolute magnitude rather than the models themselves. Our results stress the importance of adopting a standard definition of the SN parameters (x0, x1, c) in order to extract the most value out of the light curve modelling tools that are currently available and to correctly interpret results that are fit with different models.

Taylor, G. (ORCID:0000000157563259)↗

Application of entropy and signal energy for ultrasound-based classification of three-dimensional printed polyetherketoneketone components

This paper describes a preliminary method for the classification of annealed and unannealed polyetherketoneketone (PEKK) components manufactured using a material extrusion three-dimensional (3D) printing process. PEKK is representative of a class of high-performance thermoplastics that are increasingly employed as feedstocks for use in 3D printing. PEKK components may be used continuously at elevated temperatures, are chemically resistant, and able to withstand large mechanical loads. These properties render PEKK suitable as a metal component replacement in aerospace applications, high-temperature industrial applications, and surgical implants. The structure of PEKK is semi-crystalline with the specific crystallinity correlating to the final properties during application, making determination of this property crucial. This study compares three different signal processing techniques intended to distinguish annealed (high crystallinity) from unannealed (low crystallinity) components using backscattered ultrasound. The first is energy-based and is unable to detect annealing. The second two are based on different entropies of the backscattered signal: a limiting form of Renyi's entropy and a limiting form of joint entropy. The joint entropy values for the annealed and unannealed specimens fall into two non-overlapping intervals and have a statistical separation of two standard deviations.

36 MATERIALS SCIENCE↗

Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methods included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using "background makers"; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predetermining acceptable noise limits in EXAFS spectra in the limit of stochastic noise

EXAFS measurements are used to probe a variety of experimental systems, but excel at elucidating local structure in samples which have slight disorder or no long-range crystalline order. Of special interest to the authors is the use of EXAFS in understanding the molecular-level binding structure and characteristics of actinides on the surface of environmental minerals and model mineral analogs. In environmental systems the element of interest can be on the order of 10-7% by weight of the total sample. Obviously such samples would be impossible to measure using EXAFS techniques. It is therefore essential to increase the concentration of the element of interest while still preserving a sample's ability to represent environmental conditions. Under such low concentration limits it is expected that the collected data is countrate, or stochastically limited. This condition occurs as we approach the signal-to-noise (S/N) limit of the technique where the random noise of the measurement process dominates over possible systematic errors. When stochastic error is expected to dominate systematic error, it is possible to predict, with the use of simulations, the ability of model fits to tolerate a certain level of stochastic noise. Elsewhere in these proceedings, we discuss how to tell when systematic errors dominate in measured EXAFS spectrum. Here, we outline a technique for determining the number of EXAFS scans necessary to test the relevance of a given structural model. Appropriate stochastic noise levels are determined for each point in r-space by collecting data on a real system. These noise levels are then applied to EXAFS simulations using a test model. In this way, all significant systematic error sources are eliminated in the simulated data. The structural model is then fit to the simulated data, decreasing the noise and increasing the k-range of the fit until the veracity of the model passes an F-test. This paper outlines a method of testing model systems in EXAFS fitting before measurements are conducted to determine the quality of measured data required for fitting of a particular model system with statistical confidence. It is important to reiterate that the calculated {alpha}surface in figure 1 is only applicable to the particular model presented in this paper. Furthermore, this procedure only takes into account stochastic noise; consequentially any confidence levels calculated should be viewed as upper limits to the confidence levels in systems which also contain a significant amount of systematic noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DDxNet: a deep learning model for automatic interpretation of electronic health records, electrocardiograms and electroencephalograms

Effective patient care mandates rapid, yet accurate, diagnosis. With the abundance of non-invasive diagnostic measurements and electronic health records (EHR), manual interpretation for differential diagnosis has become time-consuming and challenging. This has led to wide-spread adoption of AI-powered tools, in pursuit of improving accuracy and efficiency of this process. While the unique challenges presented by each modality and clinical task demand customized tools, the cumbersome process of making problem-specific choices has triggered the critical need for a generic solution to enable rapid development of models in practice. In this spirit, we develop DDxNet, a deep architecture for time-varying clinical data, which we demonstrate to be well-suited for diagnostic tasks involving different modalities (ECG/EEG/EHR), required level of characterization (abnormality detection/phenotyping) and data fidelity (single-lead ECG/22-channel EEG). Using multiple benchmark problems, we show that DDxNet produces high-fidelity predictive models, and sometimes even provides significant performance gains over problem-specific solutions.

60 APPLIED LIFE SCIENCES↗

Pilot Point Optimization of Mining Boundaries for Lateritic Metal Deposits: Finding the Trade-off Between Dilution and Ore Loss

Geological contacts in lateritic metal deposits (footwall topographies) often delineate the orebody boundaries. Spatial variations seen in such contacts are frequently higher than those for the metal grades of the deposit. Therefore, borehole spacing chosen based on the grade variations cannot adequately capture the geological contact variability. Consequently, models created using such boreholes cause high volumetric uncertainties in the actual and targeted ore extraction volumes, which, in turn, lead to high unplanned dilution and ore losses. In this paper, a method to design optimum ore/mining boundaries for lateritic metal deposits is presented. The proposed approach minimizes the dilution/ore losses and comprises two main steps. First, the uncertainty on the orebody boundary is represented using a set of stochastic realizations generated with a multiple-point statistics algorithm. Then, the optimal orebody boundary is determined using an optimization technique inspired by a model calibration method called Pilot Points. The pilot points represent synthetic elevation values, and they are used to construct smooth mining boundaries using the multilevel B-spline technique. The performance of a generated surface is evaluated using the expected sum of losses in each of the stochastic realizations. The simulated annealing algorithm is used to iteratively determine the pilot point values which minimize the expected losses. The results show a significant reduction in the dilution volume as compared to those obtained from the actual mining operation.

58 GEOSCIENCES↗

Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A{sub z}) under the receiver operating characteristic curve. Results: The test A{sub z} values from the DBT-slice approach ranged from 0.87{+-}0.03 to 0.93{+-}0.02, while those from the PV approach ranged from 0.78{+-}0.04 to 0.84{+-}0.04. The highest test A{sub z} of 0.93{+-}0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test A{sub z} of 0.84{+-}0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images.

60 APPLIED LIFE SCIENCES↗

Kernel principal component analysis for stochastic input model generation

Highlights: {yields} KPCA is used to construct a reduced order stochastic model of permeability. {yields} A new approach is proposed to solve the pre-image problem in KPCA. {yields} Polynomial chaos is used to provide a parametric stochastic input model. {yields} Flow in porous media with channelized permeability is considered. - Abstract: Stochastic analysis of random heterogeneous media provides useful information only if realistic input models of the material property variations are used. These input models are often constructed from a set of experimental samples of the underlying random field. To this end, the Karhunen-Loeve (K-L) expansion, also known as principal component analysis (PCA), is the most popular model reduction method due to its uniform mean-square convergence. However, it only projects the samples onto an optimal linear subspace, which results in an unreasonable representation of the original data if they are non-linearly related to each other. In other words, it only preserves the first-order (mean) and second-order statistics (covariance) of a random field, which is insufficient for reproducing complex structures. This paper applies kernel principal component analysis (KPCA) to construct a reduced-order stochastic input model for the material property variation in heterogeneous media. KPCA can be considered as a nonlinear version of PCA. Through use of kernel functions, KPCA further enables the preservation of higher-order statistics of the random field, instead of just two-point statistics as in the standard Karhunen-Loeve (K-L) expansion. Thus, this method can model non-Gaussian, non-stationary random fields. In this work, we also propose a new approach to solve the pre-image problem involved in KPCA. In addition, polynomial chaos (PC) expansion is used to represent the random coefficients in KPCA which provides a parametric stochastic input model. Thus, realizations, which are statistically consistent with the experimental data, can be generated in an efficient way. We showcase the methodology by constructing a low-dimensional stochastic input model to represent channelized permeability in porous media.

97 MATHEMATICS AND COMPUTING↗