Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Infrared Scattering Scanning Near-Field Optical Microscopy Using An External Cavity Quantum Cascade Laser For Nanoscale Chemical Imaging And Spectroscopy of Explosive Residues

Infrared scattering scanning near-field optical microscopy (s-SNOM) is an apertureless superfocusing technique that uses the antenna properties of a conducting atomic force microscope (AFM) tip to achieve infrared spatial resolution below the diffraction limit. The instrument can be used either in imaging mode, where a fixed wavelength light source is tuned to a molecular resonance and the AFM raster scans an image, or in spectroscopy mode where the AFM is held stationary over a feature of interest and the light frequency is varied to obtain a spectrum. In either case, a strong, stable, coherent infrared source is required. Here we demonstrate the integration of a broadly tunable external cavity quantum cascade laser (ECQCL) into an s-SNOM and use it to obtain infrared spectra of microcrystals of chemicals adsorbed onto gold substrates. Residues of the explosive compound tetryl was deposited onto gold substrates. s-SNOM experiments were performed in the 1260-1400 cm-1 tuning range of the ECQCL, corresponding to the NO2 symmetric stretch vibrational fingerprint region. Vibrational infrared spectra were collected on individual chemical domains with a collection area of *500nm2 and compared to ensemble averaged far-field reflection-absorption infrared spectroscopy (RAIRS) results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative CT of lung nodules: Dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques

Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more calcium reference standards. To account for CT number nonuniformity in the reconstruction field, such calibration lines may be obtained at multiple locations within lung regions in an anthropomorphic phantom. The authors performed a study to investigate the effects of patient body size, anatomic region, and calibration nodule size on the derived calibration lines at ten lung region positions using both single energy (SE) and dual energy (DE) CT techniques. Simulated spherical lung nodules of two concentrations (50 and 100 mg/cc CaCO{sub 3}) were employed. Nodules of three different diameters (4.8, 9.5, and 16 mm) were scanned in a simulated thorax section representing the middle of the chest with large lung regions. The 4.8 and 9.5 mm nodules were also scanned in a section representing the upper chest with smaller lung regions. Fat rings were added to the peripheries of the phantoms to simulate larger patients. Scans were acquired on a GE-VCT scanner at 80, 120, and 140 kVp and were repeated three times for each condition. The average absolute CT number separations between the calibration lines were computed. In addition, under- or overestimates were determined when the calibration lines for one condition (e.g., small patient) were used to estimate the CaCO{sub 3} concentrations of nodules for a different condition (e.g., large patient). The authors demonstrated that, in general, DE is a more accurate method for estimating the calcium contents of lung nodules. The DE calibration lines within the lung field were less affected by patient body size, calibration nodule size, and nodule position than the SE calibration lines. Under- or overestimates in CaCO{sub 3} concentrations of nodules were also in general smaller in quantity with DE than with SE. However, because the slopes of the calibration lines for DE were about one-half the slopes for SE, the relative improvement in the concentration estimates for DE as compared to SE was about one-half the relative improvement in the separation between the calibration lines. Results in the middle of the chest thorax section with large lungs were nearly completely consistent with the above generalization. On the other hand, results in the upper-chest thorax section with smaller lungs and greater amounts of muscle and bone were mixed. A repeat of the entire study in the upper thorax section yielded similar mixed results. Most of the inconsistencies occurred for the 4.8 mm nodules and may be attributed to errors caused by beam hardening, volume averaging, and insufficient sampling. Targeted, higher resolution reconstructions of the smaller nodules, application of high atomic number filters to the high energy x-ray beam for improved spectral separation, and other future developments in DECT may alleviate these problems and further substantiate the superior accuracy of DECT in quantifying the calcium concentrations of lung nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution Characterization of UMo Alloy Microstructure

This report highlights the capabilities and procedure for high-resolution characterization of UMo fuels in PNNL. Uranium-molybdenum (UMo) fuel processing steps, from casting to forming final fuel, directly affect the microstructure of the fuel, which in turn dictates the in-reactor performance of the fuel under irradiation. In order to understand the influence of processing on UMo microstructure, microstructure characterization techniques are necessary. Higher-resolution characterization techniques like transmission electron microscopy (TEM) and atom probe tomography (APT) are needed to interrogate the details of the microstructure. The findings from TEM and APT are also directly beneficial for developing predictive multiscale modeling tools that can predict the microstructure as a function of process parameters. This report provides background on focused-ion-beam–based TEM and APT sample preparation, TEM and APT analysis procedures, and the unique information achievable through such advanced characterization capabilities for UMo fuels, from a fuel fabrication capability viewpoint.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isolating GaSb membranes grown metamorphically on GaAs substrates using highly selective substrate removal etch processes

The etch rates of NH 4 OH:H 2 O 2 and C 6 H 8 O 7 :H 2 O 2 for GaAs and GaSb have been investigated to develop a selective etch for GaAs substrates and to isolate GaSb epilayers grown on GaAs. The NH 4 OH:H 2 O 2 solution has a greater etch rate differential for the GaSb/GaAs material system than C 6 H 8 O 7 :H 2 O 2 solution. The selectivity of NH 4 OH:H 2 O 2 for GaAs/GaSb under optimized etch conditions has been observed to be as high as 11471 ± 1691 whereas that of C 6 H 8 O 7 :H 2 O 2 has been measured up to 143 ± 2. The etch contrast has been verified by isolating 2 μm thick GaSb epi-layers that were grown on GaAs substrates. GaSb membranes were tested and characterized with high-resolution X-Ray diffraction (HR-XRD) and atomic force microscopy (AFM).

36 MATERIALS SCIENCE↗

On the Prospect of Chemically Transferable Coarse-Grained Electronic Models for Soft Materials

Electronic coarse-graining (ECG) methods predict quantum-mechanical electronic properties directly from coarse-grained (CG) molecular configurations, enabling electronic predictions at mesoscale length scales. Here, we present a diagnostic assessment of the feasibility of chemically transferable ECG models across a broad polymer-relevant chemical space using all-atom, united-atom, and Martini-scale representations. While high-resolution ECG models achieve near-quantitative accuracy, we show that chemically transferable ECG at the Martini resolution fails because the CG force field does not sample the same configurational distribution of local molecular structure as that underlying the DFT-parameterized ECG model. We demonstrate that our proposed Element-Count-Label (ECL) representation, which augments Martini beads with explicit stoichiometric data, significantly improves chemical generalization across diverse polymer chemistries. However, we find that even with improved chemical resolution, the model cannot recover electronic property distributions that are absent from the configurational space sampled by the CG force field. These results demonstrate that chemically transferable ECG requires future Martini-like force fields to explicitly preserve quantum chemistry–compatible local molecular structure in addition to thermodynamic and structural fidelity.

Kidder, Katherine M [Department of Chemistry; Univ↗

The azimuthal and radial distributions of HI and H2 in NGC 6946

A study was completed of the atomic and molecular components of the ISM in NGC 6946. The distribution of molecular clouds was determined from a fully sampled CO map of the inner disk using the 14-meter telescope of the FCRAO. The distribution of atomic gas was derived from VLA observations at 40" resolution in the D configuration. When comparing the global CO and HI properties with other components of the galaxy, it was found that the azimuthally averaged radial distributions of CO, H-alpha, radio continuum and blue light all exhibit similar roughly exponential falloffs, while the azimuthally averaged HI surface densities vary by only a factor of 2 out to R = 16 kpc. This indicates that while the H-alpha/CO ratio is approximately constant with radius, the CO/HI ratio decreases by a factor of 30 from the center of the galaxy to R = 10 kpc.

Tacconi-Garman, Linda J.↗

Optical Interferometric Micrometrology

Resolutions in angstrom and subangstrom range sought for atomic-scale surface probes. Experimental optical micrometrological system built to demonstrate calibration of piezoelectric transducer to displacement sensitivity of few angstroms. Objective to develop relatively simple system producing and measuring translation, across surface of specimen, of stylus in atomic-force or scanning tunneling microscope. Laser interferometer used to calibrate piezoelectric transducer used in atomic-force microscope. Electronic portion of calibration system made of commercially available components.

Abel, Phillip B.↗

Heterogeneity and Disorder in Ti{1-x}Fe{y}O{2-d) Nanocrystal Rutile-based Flower Like Aggregates: Detection of Anatase

Here we report results of systematic investigation of heterogeneity and disorder in Ti{sub 1-x}Fe{sub y}O{sub 2-d} nanorod rutile-based flowerlike aggregates. It was found that Ti{sub 1-x}Fe{sub y}O{sub 2-d} aggregates are composed of two crystalline phases: rutile as a dominant and anatase as a minor phase. Flowerlike aggregates were found to grow from an isometric core ca. 5-10 nm in diameter that was built from anatase and rutile nanorods ca. 5 x 100 nm that were grown on the anatase surface having base plane (001) intergrowth with an anatase plane. The direction of rutile nanorods growth, i.e., direction of the nanorod elongation, was [001]. Highly nonisometric rutile crystals produce anisotropic X-ray powder diffraction line broadening and doubling of vibrational bands in Raman spectra. Both these techniques confirmed nonisometric character of rutile crystals and gave a quantitative measure of crystal shape anisotropy in excellent agreement with high-resolution transmission electron microscopy measurements. In addition, from the atomic pair distribution function and Raman spectral analyses the level of vacancy concentration was determined in rutile and anatase phases of investigated samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Size, Shape, and Arrangement of Cellulose Microfibril in Higher Plant Cell Walls

Plant cell walls from maize (Zea mays L.) are imaged using atomic force microscopy (AFM) at the sub-nanometer resolution. We found that the size and shape of fundamental cellulose elementary fibril (CEF) is essentially identical in different cell wall types, i.e., primary wall (PW), parenchyma secondary wall (pSW), and sclerenchyma secondary wall (sSW), which is consistent with previously proposed 36-chain model (Ding et al., 2006, J. Agric. Food Chem.). The arrangement of individual CEFs in these wall types exhibits two orientations. In PW, CEFs are horizontally associated through their hydrophilic faces, and the planar faces are exposed, forming ribbon-like macrofibrils. In pSW and sSW, CEFs are vertically oriented, forming layers, in which hemicelluloses are interacted with the hydrophobic faces of the CEF and serve as spacers between CEFs. Lignification occurs between CEF-hemicelluloses layers in secondary walls. Furthermore, we demonstrated quantitative analysis of plant cell wall accessibility to and digestibility by different cellulase systems at real-time using chemical imaging (e.g., stimulated Raman scattering) and fluorescence microscopy of labeled cellulases (Ding et al., 2012, Science, in press).

59 BASIC BIOLOGICAL SCIENCES↗

Surface modifications with Lissajous trajectories using atomic force microscopy

In this paper, we report a method for atomic force microscopy surface modifications with single-tone and multiple-resolution Lissajous trajectories. The tip mechanical scratching experiments with two series of Lissajous trajectories were carried out on monolayer films. The scratching processes with two scan methods have been illustrated. As an application, the tip-based triboelectrification phenomenon on the silicon dioxide surface with Lissajous trajectories was investigated. The triboelectric charges generated within the tip rubbed area on the surface were characterized in-situ by scanning Kelvin force microscopy. This method would provide a promising and cost-effective approach for surface modifications and nanofabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Resolution PDF Measurements on Ag Nanoparticles

The quantitative analysis of structural defects in Ag nanoparticles was addressed in this work. We performed atomic scale structural characterization by a combination of x-ray diffraction (XRD) using the Pair Distribution Function analysis (PDF) and High Resolution Transmission Electron Microscopy (HRTEM). The XRD measurements were performed using an innovative instrumentation setup to provide high resolution PDF patterns.

36 MATERIALS SCIENCE↗

A photoelectron-photoion coincidence imaging apparatus for femtosecond time-resolved molecular dynamics with electron time-of-flight resolution of {sigma}=18 ps and energy resolution {delta}E/E=3.5%

We report on the construction and performance of a novel photoelectron-photoion coincidence machine in our laboratory in Amsterdam to measure the full three-dimensional momentum distribution of correlated electrons and ions in femtosecond time-resolved molecular beam experiments. We implemented sets of open electron and ion lenses to time stretch and velocity map the charged particles. Time switched voltages are operated on the particle lenses to enable optimal electric field strengths for velocity map focusing conditions of electrons and ions separately. The position and time sensitive detectors employ microchannel plates (MCPs) in front of delay line detectors. A special effort was made to obtain the time-of-flight (TOF) of the electrons at high temporal resolution using small pore (5 {mu}m) MCPs and implementing fast timing electronics. We measured the TOF distribution of the electrons under our typical coincidence field strengths with a temporal resolution down to {sigma}=18 ps. We observed that our electron coincidence detector has a timing resolution better than {sigma}=16 ps, which is mainly determined by the residual transit time spread of the MCPs. The typical electron energy resolution appears to be nearly laser bandwidth limited with a relative resolution of {delta}E{sub FWHM}/E=3.5% for electrons with kinetic energy near 2 eV. The mass resolution of the ion detector for ions measured in coincidence with electrons is about {delta}m{sub FWHM}/m=1/4150. The velocity map focusing of our extended source volume of particles, due to the overlap of the molecular beam with the laser beams, results in a parent ion spot on our detector focused down to {sigma}=115 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partition of unity finite element method for quantum mechanical materials calculations

The current state of the art for large-scale quantum-mechanical simulations is the planewave (PW) pseudopotential method, as implemented in codes such as VASP, ABINIT, and many others. However, since the PW method uses a global Fourier basis, with strictly uniform resolution at all points in space, it suffers from substantial inefficiencies in calculations involving atoms with localized states, such as first-row and transition-metal atoms, and requires significant nonlocal communications, which limit parallel efficiency. Real-space methods such as finite-differences (FD) and finite-elements (FE) have partially addressed both resolution and parallel-communications issues but have been plagued by one key disadvantage relative to PW: excessive number of degrees of freedom (basis functions) needed to achieve the required accuracies. In this paper, we present a real-space partition of unity finite element (PUFE) method to solve the Kohn–Sham equations of density functional theory. In the PUFE method, we build the known atomic physics into the solution process using partition-of-unity enrichment techniques in finite element analysis. The method developed herein is completely general, applicable to metals and insulators alike, and particularly efficient for deep, localized potentials, as occur in calculations at extreme conditions of pressure and temperature. Full self-consistent Kohn–Sham calculations are presented for LiH, involving light atoms, and CeAl, involving heavy atoms with large numbers of atomic-orbital enrichments. We find that the new PUFE approach attains the required accuracies with substantially fewer degrees of freedom, typically by an order of magnitude or more, than the PW method. As a result, we compute the equation of state of LiH and show that the computed lattice constant and bulk modulus are in excellent agreement with reference PW results, while requiring an order of magnitude fewer degrees of freedom to obtain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the interplay between relaxation, defect formation, and atomic Sn distribution in Ge{sub (1−x)}Sn{sub (x)} unraveled with atom probe tomography

Ge{sub (1−x)}Sn{sub (x)} has received a lot of interest for opto-electronic applications and for strain engineering in advanced complementary-metal-oxide-semiconductor technology, because it enables engineering of the band gap and inducing strain in the alloy. To target a reliable technology for mass application in microelectronic devices, the physical problem to be addressed is to unravel the complex relationship between strain relaxation (as induced by the growth of large layer thicknesses or a thermal anneal) and defect formation, and/or stable Sn-cluster formation. In this paper, we study the onset of Sn-cluster formation and its link to strain relaxation using Atom Probe Tomography (APT). To this end, we also propose a modification of the core-linkage [Stephenson et al., Microsc. Microanal. 13, 448 (2007)] cluster analysis method, to overcome the challenges of limited detection efficiency and lateral resolution of APT, and the quantitative assessment for very small clusters (<40 atoms) embedded in a random distribution of Sn-atoms. We concluded that the main relaxation mechanism for these layers is defect generation (misfit dislocations, threading dislocations, etc.), irrespective of the cause (thickness of layer or thermal anneal) of relaxation and is independent of the cluster formation. The low thermodynamic solubility limit of Sn in Ge seems to be the driving force for Sn-cluster formation. Finally, we also discuss the spatial distribution of Sn in clusters and relate them to the theoretically predicted stable Sn clusters [Ventura et al., Phys. Rev. B 79, 155202 (2009)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defining HRTEM Resolution: Why Young?s Fringes Don?t Determine Resolution

Aberration correction of the objective lens in the high-resolution transmission electron microscope (HRTEM) can extend microscope resolution to the linear information limit [1], the upper bound of a HRTEM s structural resolution. HRTEM resolution is demonstrated canonically in real space when two image peaks (representing atoms) are distinguishable from a single peak just as Rayleigh's criterion establishes when two sources of light (stars) are distinguishable from a single source [2]. The A-OK set of specimens can be employed to measure HRTEM resolutions from 1.6 to 0.2 unequivocally in real space [3] and to characterize image resolution quality [4]. Such real-space measurements have established sub- ngstr m resolutions of 0.78 [5-6] and 0.63 [7]. Despite the straightforward approach of resolution quantification in real space, resolution is often gauged using image intensity spectrum measurements in reciprocal space, probably because resolution |d| requires the corresponding spatial frequency 1/|d| in the TEM image intensity spectrum; however, the mere presence of a 1/|d| frequency does not establish a resolution of |d| [8].

electron microscopy↗

Measuring the absolute carrier-envelope phase of many-cycle laser fields

The carrier-envelope phase (CEP) of high-peak-power, many-cycle laser fields becomes a crucial parameter when such fields are used, in conjunction with polarization gating techniques, in isolated attosecond (asec) pulse generation. However, its measurement has not been achieved so far. We demonstrate a physical process sensitive to the CEP value of such fields and describe a method for its online shot-to-shot monitoring. This work paves the way for the exploitation of energetic isolated asec pulses in studies of nonlinear extreme ultraviolet (XUV) processes and XUV-pump-XUV-probe experiments with asec resolutions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions

A description is given of new tools to facilitate model building and refinement into electron cryo-microscopy reconstructions. The recent rapid development of single-particle electron cryo-microscopy (cryo-EM) now allows structures to be solved by this method at resolutions close to 3 Å. Here, a number of tools to facilitate the interpretation of EM reconstructions with stereochemically reasonable all-atom models are described. The BALBES database has been repurposed as a tool for identifying protein folds from density maps. Modifications to Coot, including new Jiggle Fit and morphing tools and improved handling of nucleic acids, enhance its functionality for interpreting EM maps. REFMAC has been modified for optimal fitting of atomic models into EM maps. As external structural information can enhance the reliability of the derived atomic models, stabilize refinement and reduce overfitting, ProSMART has been extended to generate interatomic distance restraints from nucleic acid reference structures, and a new tool, LIBG, has been developed to generate nucleic acid base-pair and parallel-plane restraints. Furthermore, restraint generation has been integrated with visualization and editing in Coot, and these restraints have been applied to both real-space refinement in Coot and reciprocal-space refinement in REFMAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision calculation of above-threshold multiphoton ionization in intense short-wavelength laser fields: The momentum-space approach and time-dependent generalized pseudospectral method

We present an approach in momentum (P) space for the accurate study of multiphoton and above-threshold ionization (ATI) dynamics of atomic systems driven by intense laser fields. In this approach, the electron wave function is calculated by solving the P-space time-dependent Schroedinger equation (TDSE) in a finite P-space volume under a simple zero asymptotic boundary condition. The P-space TDSE is propagated accurately and efficiently by means of the time-dependent generalized pseudospectral method with optimal momentum grid discretization and a split-operator time propagator in the energy representation. The differential ionization probabilities are calculated directly from the continuum-state wave function obtained by projecting the total electron wave function onto the continuum-state subspace using the projection operator constructed by the continuum eigenfunctions of the unperturbed Hamiltonian. As a case study, we apply this approach to the nonperturbative study of the multiphoton and ATI dynamics of a hydrogen atom exposed to intense short-wavelength laser fields. High-resolution photoelectron energy-angular distribution and ATI spectra have been obtained. We find that with the increase of the laser intensity, the photoelectron energy-angular distribution changes from circular to dumbbell shaped and is squeezed along the laser field direction. We also explore the change of the maximum photoelectron energy with laser intensity and strong-field atomic stabilization phenomenon in detail.

74 ATOMIC AND MOLECULAR PHYSICS↗