Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Visualization and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

DFTT report for Signal Analysis (2023)

The Detection Framework Testbed and Toolkit (DFTT) is a database and associated java programs intended to facilitate the development and testing of algorithms for operating suites of correlation and subspace detectors. This framework is a generalization of the system described in Harris and Dodge (2011) and Dodge and Harris (2016). DFTT allows retrospective processing of sequences of data using various system configurations. Results are saved in a database, so it is easy to compare the results obtained using different configurations of the system. The principal software components of DFTT are the ConfigCreator, the framework_runner and the Builder program. ConfigCreator assembles the files necessary to define a particular configuration used for processing. The framework_runner operates suites of detectors and saves the results in an Oracle™ database. Builder allows visual examination of templates and detected signals and allows editing and creation of detectors. In addition, there are tools for importing continuous data into the database. DFTT is licensed under the MIT license and has LLNL release number LLNL-CODE-801881. In the current fiscal year DFTT has been used in two different projects. The first (NTL-funded) project investigates the feasibility of screening nuisance detections using correlation detectors. The second (GNEM-funded) project seeks to extend the results of Harris and Dodge (2021) to 3- D sources and multiple stations. Each of these efforts required that additional functionality be added to DFTT. In this report I will summarize the enhancements to DFTT in the context of the relevant research effort.

58 GEOSCIENCES↗

An Updated Visual Orbit of the Directly Imaged Exoplanet 51 Eridani b and Prospects for a Dynamical Mass Measurement with Gaia

We present a revision to the visual orbit of the young, directly imaged exoplanet 51 Eridani b using four years of observations with the Gemini Planet Imager. The relative astrometry is consistent with an eccentric (e=0.53{sub -0.13}{sup +0.09}) orbit at an intermediate inclination (i=136{sub -11}{sup +10} °), although circular orbits cannot be excluded due to the complex shape of the multidimensional posterior distribution. We find a semimajor axis of 11.1{sub -1.3}{sup +4.2} au and a period of 28.1{sub -4.9}{sup +17.2} yr, assuming a mass of 1.75 M{sub ⊙} for the host star. We find consistent values with a recent analysis of VLT/SPHERE data covering a similar baseline. We investigate the potential of using the absolute astrometry of the host star to obtain a dynamical mass constraint for the planet. The astrometric acceleration of 51 Eri derived from a comparison of the Hipparcos and Gaia catalogs was found to be inconsistent at the 2σ–3σ level with the predicted reflex motion induced by the orbiting planet. Potential sources of this inconsistency include a combination of random and systematic errors between the two astrometric catalogs and the signature of an additional companion within the system interior to current detection limits. We also explored the potential of using Gaia astrometry alone for a dynamical mass measurement of the planet by simulating Gaia measurements of the motion of the photocenter of the system over the course of the extended 8 yr mission. We find that such a measurement is only possible (>98% probability) given the most optimistic predictions for the Gaia scan astrometric uncertainties for bright stars and a high mass for the planet (≳3.6 M {sub Jup}).

79 ASTRONOMY AND ASTROPHYSICS↗

Chimbuko: A Workflow-Level Scalable Performance Trace Analysis Tool

ABSTRACT Due to the sheer volume of data it is typically impractical to analyze the detailed performance of an HPC application running at-scale. While conventional small-scale benchmarking and scaling studies are often sufficient for simple applications, many modern workflow-based applications couple multiple elements with competing resource demands and complex inter-communication patterns for which performance cannot easily be studied in isolation and at small scale. This work discusses Chimbuko, a performance analysis framework that provides real-time, in situ anomaly detection. By focusing specifically on performance anomalies and their origin (aka provenance), data volumes are dramatically reduced without losing necessary details. To the best of our knowledge, Chimbuko is the first online, distributed, and scalable workflow-level performance trace analysis framework. We demonstrate the tool's usefulness on Oak Ridge National Laboratory's Summit system.

97 MATHEMATICS AND COMPUTING↗

Optical Spectroscopy and Multivariate Analysis for Biodosimetry and Monitoring of Radiation Injury to the Skin

In the event of an intentional or accidental release of ionizing radiation in a densely populated area, timely assessment and triage of the general population for the radiation exposure is critical. In particular, a significant number of the victims may sustain cutaneous radiation injury, which increases the mortality and worsens the overall prognosis of the victims suffered from combined thermal/mechanical and radiation trauma. Diagnosis of the cutaneous radiation injury is challenging, and established methods largely rely on visual manifestations, presence of the skin contamination, and a high degree of recall by the victim. Availability of a high throughput non-invasive in vivo biodosimetry tool for assessment of the radiation exposure of the skin is of particular importance for the timely diagnosis of the cutaneous injury. In the reported investigation, we have tested the potential of an optical reflectance spectroscopy for the evaluation of the radiation injury to the skin. This is technically attractive because optical spectroscopy relies on well-established and routinely used for various applications instrumentation, one example being pulse oximetry which uses selected wavelengths for the quantification of the blood oxygenation. Our method relies on a broad spectral region ranging from the locally absorbed, shallow-penetrating ultraviolet and visible (250 to 800 nm) to more deeply penetrating near-Infrared (800 – 1600 nm) light for the monitoring of multiple physiological changes in the skin upon irradiation. Chemometrics is a multivariate methodology that allows the information from entire spectral region to be used to generate predictive regression models. In this report we demonstrate that simple spectroscopic method, such as the optical reflectance spectroscopy, in combination with multivariate data analysis, offers the promise of rapid and non-invasive in vivo diagnosis and monitoring of the cutaneous radiation exposure, and is able accurately predict the dose and time of exposure in the rodent model.

Levitskaia, Tatiana G↗

The ultra-long GRB 111209A. II. Prompt to afterglow and afterglow properties

The 'ultra-long' gamma-ray burst GRB 111209A at redshift z = 0.677 is the longest GRB ever observed thus far, with a rest frame prompt emission duration of ∼4 hr. In order to explain the burst exceptional longevity, a low-metallicity blue supergiant progenitor was invoked. In this article we further constrain the phenomenology and progenitor properties of this peculiar GRB by performing a multiband temporal and spectral analysis of both the prompt and the afterglow emission. We use proprietary and publicly available data from Swift, Konus WIND, XMM-Newton, and TAROT, as well as from other ground-based optical and radio telescopes. We find some peculiar properties that are possibly connected to the exceptional nature of this burst, namely: (1) an unprecedented large optical delay of 410 ± 50 s between the peak time in gamma-rays and the peak time in the optical of a marked multiwavelength flare; (2) multiwavelength prompt emission spectral modeling requires a certain amount of dust in the circumburst environment. The dust produces a rest frame visual extinction of A{sub V} = 0.3-1.5 mag, and may undergo destruction at late times; and (3) we detect the presence of a hard spectral extra power-law component at the end of the X-ray steep steep decay phase and before the start of the X-ray afterglow, which has never been revealed thus far in past GRBs. The optical afterglow shows more usual properties; it has a flux power-law decay with an index of 1.6 ± 0.1 and a late rebrightening feature observed at ∼1.1 the day after the first Burst Alert Telescope trigger. We discuss our findings in the context of several possible interpretations that have been given thus far of the complex multiband GRB phenomenology and propose a binary channel formation for the blue supergiant progenitor.

79 ASTRONOMY AND ASTROPHYSICS↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

Integration of transcriptomic and proteomic data identifies biological functions in cell populations from human infant lung

Systems biology uses computational approaches to integrate diverse data types to understand cell and organ behavior. Data derived from complementary technologies, for example transcriptomic and proteomic analyses, are providing new insights into development and disease. We compared mRNA and protein profiles from purified endothelial, epithelial, immune, and mesenchymal cells from normal human lung tissue. Signatures for each cell type were identified and compared at both mRNA and protein levels. Cell specific biological processes and pathways were predicted by analysis of concordant and discordant RNA-protein pairs. Cell clustering and gene set enrichment comparisons identified shared versus unique processes associated with transcriptomic and/or proteomic data. Clear cell-cell correlations between mRNA and protein data were obtained from each cell type. Approximately 40% of RNA-protein pairs were coherently expressed. While the correlation between RNA and their protein products was relatively low (approximately 0.4), cell specific signature genes involved in functional processes characteristic of each cell type, were more highly correlated with their protein products. Consistency of cell specific RNA-protein signatures indicated an essential framework for the function of each cell type. Visualization and reutilization of the protein and RNA profiles are supported by a new web application, "LungProteomics," which is incorporated into the LGEA web portal and freely accessible at (https://research.cchmc.org/pbge/lunggens/lungProteomics/human_sorted_profiles.html).

human lung, sorted cells, integrated omics, Transc↗

AnalyzeThis: An Analysis Workflow-Aware Storage System

The need for novel data analysis is urgent in the face of a data deluge from modern applications. Traditional approaches to data analysis incur significant data movement costs, moving data back and forth between the storage system and the processor. Emerging Active Flash devices enable processing on the flash, where the data already resides. An array of such Active Flash devices allows us to revisit how analysis workflows interact with storage systems. By seamlessly blending together the flash storage and data analysis, we create an analysis workflow-aware storage system, AnalyzeThis. Our guiding principle is that analysis-awareness be deeply ingrained in each and every layer of the storage, elevating data analyses as first-class citizens, and transforming AnalyzeThis into a potent analytics-aware appliance. We implement the AnalyzeThis storage system atop an emulation platform of the Active Flash array. Our results indicate that AnalyzeThis is viable, expediting workflow execution and minimizing data movement.

Data Analytics↗

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

Calibrating Bayesian Network Representations of Social-Behavioral Models

While human behavior has long been studied, recent and ongoing advances in computational modeling present opportunities for recasting research outcomes in human behavior. In this paper we describe how Bayesian networks can represent outcomes of human behavior research. We demonstrate a Bayesian network that represents political radicalization research – and show a corresponding visual representation of aspects of this research outcome. Since Bayesian networks can be quantitatively compared with external observations, the representation can also be used for empirical assessments of the research which the network summarizes. For a political radicalization model based on published research, we show this empirical comparison with data taken from the Minorities at Risk Organizational Behaviors database.

99 GENERAL AND MISCELLANEOUS↗

Comparative Analysis of Report-Back of Research Results Strategies for Personal Chemical Exposure Data

Background. Report-back of research results (RBRR) is ethically supported and highly requested by participants yet lacks broadly transferable guidelines for RBRR. Effective RBRR must be responsive to target audience needs and may not be addressed by a ‘one-size-fits-all’ approach. Objective. Within a subset of our 19 studies on RBRR, we had the unique opportunity to carry out a comparative analysis of RBRR strategies across cohorts with similar development and evaluation methods, yet distinct in life stage, geography, number and type of chemicals assessed, and community contexts. Methods. We highlight key outcomes from three environmental health studies: an ongoing New York, NY cohort (Fair Start; n=486) and a Detroit, MI cohort (CLEAR; n=34) assessing exposure to ambient urban pollution during pregnancy, and a longitudinal cohort in Houston, TX (Houston-3H) following Hurricane Harvey (n=312). Focus group and survey data were analyzed to identify lessons learned and explore how RBRR supports understanding of environmental health. Results. Commonalities emerged in RBRR development, design, organization, and data visualization, as well as in how RBRR can contribute to an understanding of health-environment connections. Differences included preferences for individual versus community level findings, as well as distinguishable contextual considerations. For pregnancy cohorts, messaging was framed with cultural sensitivity, and to avoid unintended consequences of parental guilt due to prenatal exposures. In the post-disaster Houston-3H study, participants requested additional transparency regarding sampling design and study rationale. Significance. All RBRR case studies reported chemicals without known regulatory or health guidelines, so results were contextualized within the study population. Participants across cohorts requested multi-study comparisons to better understand their results beyond their communities. While foundational RBRR elements (e.g. plain language, graphic organizers) may supersede cohort-specific differences, RBRR should be personalized to encompass perceptions of health across different life-stage, cultural, and environmental contexts.

Vogel, Taylor J.↗

Climate Data Analysis Tools

Climate Data Analysis Tools (CDAT) is a software infrastructure that uses an object-oriented scripting language to link together separate software subsystems and packages thus forming an integrated environment for solving model diagnosis problems, The power of the system comes from Python and its ability to seamlissly interconnect software. Python provides a general purpose and full-featured scripting language with a variety of user interfaces including command-line interaction, stand-alone scripts (applications) and fraphical user interfaces (GUI). The CDAT subsystems, implemented as modules, provide access to and management of gridded data (Climate Data Management Systems or CDMS); large-array numerical operations (Numerical Python); and visualization (Visualization and Control System or VCS).

Source record↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an opensource electronic hardware platform, and it consists of a microcontroller and two sensors. We read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it. This project and code demo are available on the GitHub site at this URL: https://github.com/santorofer/MDSplusAndCustomeDevices

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Climate Data Analysis Tools

Climate Data Analysis Tools (CDAT) is a software infrastructure that uses an object-oriented scripting language to link together separate software subsystems and packages thus forming an integrated environment for solving model diagnosis problems, The power of the system comes from Python and its ability to seamlissly interconnect software. Python provides a general purpose and full-featured scripting language with a variety of user interfaces including command-line interaction, stand-alone scripts (applications) and fraphical user interfaces (GUI). The CDAT subsystems, implemented as modules, provide access to and management of gridded data (Climate Data Management Systems or CDMS); large-array numerical operations (Numerical Python); and visualization (Visualization and Control System or VCS).

Source record↗

Size_resolved_ice_nucleating_particle_INP_concentrations_from_the_INPOP_campaign

Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the US DOE ARM AMF3 in Oliktok Point, AK from 1 Mar to 31 May 2017. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D, had particle size cuts at 2.96, 1.21, 0.34, and 0.15 µm in particle diameter. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. The pump typically pulled 25 lpm at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 36,000 total L of air per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Following collection and transport from AMF3 to PI Creamean's laboratory in Boulder, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile bags and stored in a standard commercial freezer until analysis (approximately 4 – 5 months after collection). Drop freezing assays (DFAs) were conducted on one daily sample per week of the study for all four stages, with daily samples analyzed from 22 - 29 May 2017. Immediately after removal from the freezer, 2 mL of ultrapure water was added with a single-use sterile syringe directly to the bags, then mixed using a vortex mixer for 2 hours at 500 rpm to resuspend particles from the PFA into the ultrapure water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 µL each), though careful inspection. The plate was cooled at approximately 3 – 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected, but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen can be calculated as can the estimated INP concentration per L of air using the equation from Vali (1971): [INPs] = −(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 1971.

4-stage DRUM aerosol collector (DA400),Aerosol imp↗

YOLO2U-Net: Detection-guided 3D instance segmentation for microscopy

Microscopy imaging techniques are instrumental for characterization and analysis of biological structures. As these techniques typically render 3D visualization of cells by stacking 2D projections, issues such as out-of-plane excitation and low resolution in the z-axis may pose challenges (even for human experts) to detect individual cells in 3D volumes as these non-overlapping cells may appear as overlapping. In this paper a comprehensive method for accurate 3D instance segmentation of cells in the brain tissue is introduced. The proposed method combines the 2D YOLO detection method with a multi-view fusion algorithm to construct a 3D localization of the cells. Next, the 3D bounding boxes along with the data volume are input to a 3D U-Net network that is designed to segment the primary cell in each 3D bounding box, and in turn, to carry out instance segmentation of cells in the entire volume. The promising performance of the proposed method is shown in comparison with current deep learning-based 3D instance segmentation methods.

3D instance segmentation↗