A Model-Based Systems Engineering Evaluation of the Evolution to an In-Time Aviation Safety Management System

In 2018, as result of a recommendation from the National Academies, NASA began to prototype an In-Time Aviation Safety Management System(IASMS). The purpose of the IASMS is to enable innovative aviation operations and greater heterogeneity of the overall National Airspace (NAS) by automating much of the safety monitoring, assessment, and risk and hazard mitigation functionspresent in today’s Safety Management Systems (SMS). NASA has worked together with early industry collaborators to understand how such a system might work and has published several early Concepts of Operation (ConOps) and other technical memoranda that illustrate the primary considerations for selected aviation domains. The shift from an SMS to an IASMS is predicated on several assumptions, including: 1.) automating safety functions will decrease the amount of time necessary for risk and hazard identification and analysis, making it more likely that safety concerns are understood ‘in-time’ to mitigate them, and 2.) an IASMS will allow easier tailoring of safety management processes to the particular risks and hazards inherent to that aviation operation. In this paper, we begin to validate these assumptions through the use of Model-Based Systems Engineering (MBSE).

In-time Aviation Safety Management System↗

MSL Telecom Automated Anomaly Detection

The Mars Science Laboratory (MSL) Telecom Operations Team at the Jet Propulsion Laboratory (JPL) has implemented a machine learning system in order to automate the anomaly detection process as a part of daily operations. Machine learning enables reliable detection of anomalies in Telecom-related telemetry and automated reporting of Telecom subsystem status, resulting in an 90% reduction in team workload and improved anomaly detection reliability. At present, machine learning methods are used to detect: 1. Anomalous long-term trends in telemetry data 2. Anomalous time-domain evolution of telemetry values Both types of anomalies pose their own unique challenges that are addressed in different ways. In the first case, long term trending of daily minima, maximum, and mean telemetry values in temperatures, currents, voltages, and radio frequency (RF) power levels is used in addition to hard threshold safety checks to look for changes in long-term equipment health and performance. Long-term trending methods allow for ordinary seasonal variations in these quantities caused by temperature changes over the course of the Martian year while allowing operators to determine whether current performance remains in line with historical values from previous years. Changes in long-term trends can provide important insights into the health and status of the rover's on-board systems as well as valuable early warning if subtle degradation begins to take hold. But while trending of daily statistics is valuable, it does not detect anomalies in the short-term time evolution of data over the course of minutes or hours during a day, and this task is handled with short-term shape analysis. Principal components analysis (PCA) has been found to provide robust detection of short-term anomalies, and several examples of the use of PCA to detect actual anomalous events will be provided here. In using PCA, we use both the percentage of explained variance and also a log likelihood test on the PCA expansion coefficients to flag telemetry data for human review. Previous work in the field of spacecraft anomaly detection includes [1] for MSL and [2] for some other JPL missions.

Mukai, Ryan↗

Simultaneously Dual Modification of Ni-Rich Layered Oxide Cathode for High-Energy Lithium-Ion Batteries

A critical challenge in the commercialization of layer-structured Ni-rich materials is the fast capacity drop and voltage fading due to the interfacial instability and bulk structural degradation of the cathodes during battery operation. Herein, with the guidance of theoretical calculations of migration energy difference between La and Ti from the surface to the inside of LiNi 0.8 Co 0.1 Mn 0.1 O 2 , for the first time, Ti-doped and La 4 NiLiO 8 -coated LiNi 0.8 Co 0.1 Mn 0.1 O 2 cathodes are rationally designed and prepared, via a simple and convenient dual-modification strategy of synchronous synthesis and in situ modification. Impressively, the dual modified materials show remarkably improved electrochemical performance and largely suppressed voltage fading, even under exertive operational conditions at elevated temperature and under extended cutoff voltage. Further studies reveal that the nanoscale structural degradation on material surfaces and the appearance of intergranular cracks associated with the inconsistent evolution of structural degradation at the particle level can be effectively suppressed by the synergetic effect of the conductive La 4 NiLiO 8 coating layer and the strong Ti—O bond. The present work demonstrates that our strategy can simultaneously address the two issues with respect to interfacial instability and bulk structural degradation, and it represents a significant progress in the development of advanced cathode materials for high-performance lithium-ion batteries.

36 MATERIALS SCIENCE↗

Constrained quantum optimization for extractive summarization on a trapped-ion quantum computer

Abstract Realizing the potential of near-term quantum computers to solve industry-relevant constrained-optimization problems is a promising path to quantum advantage. In this work, we consider the extractive summarization constrained-optimization problem and demonstrate the largest-to-date execution of a quantum optimization algorithm that natively preserves constraints on quantum hardware. We report results with the Quantum Alternating Operator Ansatz algorithm with a Hamming-weight-preserving XY mixer (XY-QAOA) on trapped-ion quantum computer. We successfully execute XY-QAOA circuits that restrict the quantum evolution to the in-constraint subspace, using up to 20 qubits and a two-qubit gate depth of up to 159. We demonstrate the necessity of directly encoding the constraints into the quantum circuit by showing the trade-off between the in-constraint probability and the quality of the solution that is implicit if unconstrained quantum optimization methods are used. We show that this trade-off makes choosing good parameters difficult in general. We compare XY-QAOA to the Layer Variational Quantum Eigensolver algorithm, which has a highly expressive constant-depth circuit, and the Quantum Approximate Optimization Algorithm. We discuss the respective trade-offs of the algorithms and implications for their execution on near-term quantum hardware.

97 MATHEMATICS AND COMPUTING↗

Core performance predictions in projected SPARC first-campaign plasmas with nonlinear CGYRO

This work characterizes the core transport physics of SPARC early-campaign plasmas using the PORTALS-CGYRO framework. Empirical modeling of SPARC plasmas with L-mode confinement indicates an ample window of breakeven (Q > 1) without the need of H-mode operation. Extensive modeling of multi-channel (electron energy, ion energy, and electron particle) flux-matched conditions with the nonlinear CGYRO code for turbulent transport coupled to the macroscopic plasma evolution using PORTALS reveals that the maximum fusion performance to be attained will be highly dependent on the near-edge pressure. Stiff core transport conditions are found, particularly when fusion gain approaches unity, and predicted density peaking is found to be in line with empirical databases of particle source-free H-modes. Impurity optimization is identified as a potential avenue to increase fusion performance while enabling core-edge integration. Extensive validation of the quasilinear TGLF model builds confidence in reduced-model predictions. The implications of projecting L-mode performance to high-performance and burning-plasma devices is discussed, together with the importance of predicting edge conditions.

Rodriguez-Fernandez, P. (ORCID:0000000273611131)↗

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION↗

Cation reordering instead of phase transitions: Origins and implications of contrasting lithiation mechanisms in 1D ζ- and 2D α-V 2 O 5

Substantial improvements in cycle life, rate performance, accessible voltage, and reversible capacity are required to realize the promise of Li-ion batteries in full measure. Here, we have examined insertion electrodes of the same composition (V 2 O 5 ) prepared according to the same electrode specifications and comprising particles with similar dimensions and geometries that differ only in terms of their atomic connectivity and crystal structure, specifically two-dimensional (2D) layered α-V 2 O 5 that crystallizes in an orthorhombic space group and one-dimensional (1D) tunnel-structured ζ-V 2 O 5 crystallized in a monoclinic space group. By using particles of similar dimensions, we have disentangled the role of specific structural motifs and atomistic diffusion pathways in affecting electrochemical performance by mapping the dynamical evolution of lithiation-induced structural modifications using ex situ scanning transmission X-ray microscopy, operando synchrotron X-ray diffraction measurements, and phase-field modeling. We find the operation of sharply divergent mechanisms to accommodate increasing concentrations of Li-ions: a series of distortive phase transformations that result in puckering and expansion of interlayer spacing in layered α-V 2 O 5 , as compared with cation reordering along interstitial sites in tunnel-structured ζ-V 2 O 5 . By alleviating distortive phase transformations, the ζ-V 2 O 5 cathode shows reduced voltage hysteresis, increased Li-ion diffusivity, alleviation of stress gradients, and improved capacity retention. The findings demonstrate that alternative lithiation mechanisms can be accessed in metastable compounds by dint of their reconfigured atomic connectivity and can unlock substantially improved electrochemical performance not accessible in the thermodynamically stable phase.

25 ENERGY STORAGE↗

Three-Dimensional Chiral Lattice Fermion in Floquet Systems

Here, we show that the Nielsen-Ninomiya no-go theorem still holds on a Floquet lattice: there is an equal number of right-handed and left-handed Weyl points in a three-dimensional Floquet lattice. However, in the adiabatic limit, where the time evolution of the low-energy subspace is decoupled from the high-energy subspace, we show that the bulk dynamics in the low-energy subspace can be described by Floquet bands with extra left- or right-handed Weyl points, despite the no-go theorem. Assuming adiabatic evolution of two bands, we show that the difference of the number of right-handed and left-handed Weyl points equals twice the winding number of the adiabatic Floquet operator over the Brillouin zone. Based on these findings, we propose a realization of purely left- or right-handed Weyl particles on a 3D lattice using a Hamiltonian obtained through dimensional reduction of a four-dimensional quantum Hall system. We argue that the breakdown of the adiabatic approximation on the surface facilitates unusual closed orbits of wave packets in an applied magnetic field, which traverse alternatively through the low-energy and high-energy sector of the spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Efficient truncations of SU( N c ) lattice gauge theory for quantum simulation

Quantum simulations of lattice gauge theories offer the potential to directly study the nonperturbative dynamics of quantum chromodynamics, but naive analyses suggest that they require large computational resources. Large 𝑁 𝑐 expansions are performed to order 1/𝑁 𝑐 to simplify the Hamiltonian of pure SU⁡(𝑁𝑐) lattice gauge theories. A reformulation of the electric basis is introduced with a truncation strategy based on the construction of local Krylov subspaces with plaquette operators. Numerical simulations show that these truncated Hamiltonians are consistent with traditional lattice calculations at relatively small couplings. It is shown that the computational resources required for quantum simulation of time evolution generated by these Hamiltonians is 17–19 orders of magnitude smaller than previous approaches, provided that the truncations in this work can reach lattice spacings in three-dimensional simulations comparable to the two-dimensional simulations performed.

Lattice QCD↗

Deep Koopman Neural Network for Analyzing High-Energy-Density Simulations of Electrical Wire Explosions

Megaampere-scale electrical wire experiments (EWEs) provide a platform for studying magnetohydrodynamic (MHD) instability growth in magneto-inertial fusion (MIF) devices. Even when nonlinear simulations of these experiments can digitally reproduce much of the experimentally observed instability growth, interpreting the results and understanding mode growth and evolution can be non-trivial. As a first step toward providing better interpretation of these simulation features, this work investigates the use of a deep neural network that uses Koopman operator theory to analyze the dynamics of pulsed-power-driven explosions of EWEs. This deep neural network is trained on 1-D resistive MHD simulations of EWEs. This neural network learns to transform the nonlinear data into a lower-dimensional representation where the time dynamics are linear. Layers of this neural network are shown to learn features of the simulations, including the locations of shock waves and different physical regimes of the simulation. Using the learned features, the network can compress a time state of the simulation consisting of 5120 data point into a 36-parameter lower-dimensional latent space embedding. Furthermore, these embeddings are shown to be clustered in the latent space by initial radius and time state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Methods for R&D Portfolio Analysis and Evaluation (Workshop Report)

The Workshop on Methods for R&D Portfolio Analysis and Evaluation convened on 17–18 July 2019 at the National Renewable Energy Laboratory in Golden, Colorado, and examined strengths and weaknesses of the various methodologies applicable to R&D portfolio modeling, analysis, and decision support, given pragmatic constraints such as data availability, uncertainties in estimating the impact of R&D spending, and practical operational overheads. Participants employed their deep expertise in approaches such as stochastic optimization, real options, Monte-Carlo analysis, Bayesian networks, decision theory, complex systems analysis, deep uncertainty, and technology-evolution modeling to critique the initial example models developed by the project’s core team and to conduct thought experiments grounded in real-life technology models, progress data, expert elicitation, and portfolio information. This engagement of participants’ methodological expertise with the practical requirements of real-life portfolio decision support yielded ideas for improved approaches, alternative methodological hypotheses, and hybridization of methodologies that are well-grounded theoretically, computationally sound, and realistically executable given data availability and other practical constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for R&D Portfolio Analysis and Evaluation (Workshop Report)

The Workshop on Methods for R&D Portfolio Analysis and Evaluation convened on 17-18 July 2019 at the National Renewable Energy Laboratory in Golden, Colorado, and examined strengths and weaknesses of the various methodologies applicable to R&D portfolio modeling, analysis, and decision support, given pragmatic constraints such as data availability, uncertainties in estimating the impact of R&D spending, and practical operational overheads. Participants employed their deep expertise in approaches such as stochastic optimization, real options, Monte-Carlo analysis, Bayesian networks, decision theory, complex systems analysis, deep uncertainty, and technology-evolution modeling to critique the initial example models developed by the project’s core team and to conduct thought experiments grounded in real-life technology models, progress data, expert elicitation, and portfolio information. This engagement of participants’ methodological expertise with the practical requirements of real-life portfolio decision support yielded ideas for improved approaches, alternative methodological hypotheses, and hybridization of methodologies that are well-grounded theoretically, computationally sound, and realistically executable given data availability and other practical constraints.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laser-Produced Coherent X-ray Sources. Final report

This is the final report for the DOE-AMO DE-FG02-05ER15663 grant. Using a high-peak-power laser system at the Extreme Light Laboratory of the University of Nebraska-Lincoln, we develop novel femtosecond radiation sources and use them to investigate ultrafast photo-induced processes. Pulses of high energy electrons and x-rays are generated when an optical pulse is focused to ultra-high intensity. The radiation is used to probe the evolution of matter under highly non-equilibrium conditions with atomic-scale temporal and spatial resolution. Moreover, the facility is small enough to fit in a university laboratory and is operated by graduate students and postdocs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Block encoding bosons by signal processing

Block Encoding (BE) is a crucial subroutine in many modern quantum algorithms, including those with near-optimal scaling for simulating quantum many-body systems, which often rely on Quantum Signal Processing (QSP). Currently, the primary methods for constructing BEs are the Linear Combination of Unitaries (LCU) and the sparse oracle approach. In this work, we demonstrate that QSP-based techniques, such as Quantum Singular Value Transformation (QSVT) and Quantum Eigenvalue Transformation for Unitary Matrices (QETU), can themselves be efficiently utilized for BE implementation. Specifically, we present several examples of using QSVT and QETU algorithms, along with their combinations, to block encode Hamiltonians for lattice bosons, an essential ingredient in simulations of high-energy physics. We also introduce a straightforward approach to BE based on the exact implementation of Linear Operators Via Exponentiation and LCU (LOVE-LCU). We find that, while using QSVT for BE results in the best asymptotic gate count scaling with the number of qubits per site, LOVE-LCU outperforms all other methods for operators acting on up to qubits, highlighting the importance of concrete circuit constructions over mere comparisons of asymptotic scalings. Using LOVE-LCU to implement the BE, we simulate the time evolution of single-site and two-site systems in the lattice theory using the Generalized QSP algorithm and compare the gate counts to those required for Trotter simulation.

Kane, Christopher F↗

Space transportation system payload safety policy

A brief description of the Space Transportation System (STS) is given, and the evolution of a payload safety policy for it is described. The policy adopted in June, 1976, minimizes STS involvement in the payload design process while maintaining the assurance of a safe operation. The payload developer is responsible for assurance of safety and verification of compliance with the requirements. The STS will exercise reviews to ensure that interaction between payloads does not create hazards.