Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Computing equilibrium free energies through a nonequilibrium quench

Many methods to accelerate sampling of molecular configurations are based on the idea that temperature can be used to accelerate rare transitions. These methods typically compute equilibrium properties at a target temperature using reweighting or through Monte Carlo exchanges between replicas at higher temperatures. A recent paper [G. M. Rotskoff and E. Vanden-Eijnden, Phys. Rev. Lett. 122, 150602 (2019)] demonstrated that accurate equilibrium densities of states can also be computed through a nonequilibrium “quench” process, where sampling is performed at a higher temperature to encourage rapid mixing and then quenched to lower energy states with dissipative dynamics. Here, we provide an implementation of the quench dynamics in LAMMPS and evaluate a new formulation of nonequilibrium estimators for the computation of partition functions or free energy surfaces (FESs) of molecular systems. We show that the method is exact for a minimal model of N-independent harmonic springs and use these analytical results to develop heuristics for the amount of quenching required to obtain accurate sampling. We then test the quench approach on alanine dipeptide, where we show that it gives an FES that is accurate near the most stable configurations using the quench approach but disagrees with a reference umbrella sampling calculation in high FE regions. We then show that combining quenching with umbrella sampling allows the efficient calculation of the free energy in all regions. Moreover, by using this combined scheme, we obtain the FES across a range of temperatures at no additional cost, making it much more efficient than standard umbrella sampling if this information is required. Finally, we discuss how this approach can be extended to solute tempering and demonstrate that it is highly accurate for the case of solvated alanine dipeptide without any additional modifications.

Chemistry↗

Determination and optimization of spatial samples for distributed measurements.

There are no accepted standards for determining how many measurements to take during part inspection or where to take them, or for assessing confidence in the evaluation of acceptance based on these measurements. The goal of this work was to develop a standard method for determining the number of measurements, together with the spatial distribution of measurements and the associated risks for false acceptance and false rejection. Two paths have been taken to create a standard method for selecting sampling points. A wavelet-based model has been developed to select measurement points and to determine confidence in the measurement after the points are taken. An adaptive sampling strategy has been studied to determine implementation feasibility on commercial measurement equipment. Results using both real and simulated data are presented for each of the paths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computing Reaction Kinetics with MC-PDFT–OPESf: Combining Multireference Electronic Structure Theory and Enhanced Sampling

Accurate rate constants are crucial for understanding and optimizing catalytic reactions mediated by enzymes, metalloproteins, and heterogeneous catalysts. These systems frequently present a dual computational challenge. Multiconfigurational reaction sites require multireference techniques for the accurate treatment of the electronic structure, and high activation barriers prevent efficient sampling of unbiased reactive transitions. In this work, we combine multiconfiguration pair-density functional theory (MC-PDFT) as an accurate and efficient multireference electronic structure method with on-the-fly probability-enhanced sampling flooding (OPESf) as an enhanced sampling method capable of accelerating reactive transitions. We demonstrate the approach on the Diels–Alder [4+2] cycloaddition between cis-butadiene and ethene as a reaction characterized by a large activation barrier and multireference character. MC-PDFT–OPESf provides reaction rates in agreement with experiments at a fraction of the computational cost required by conventional unbiased ab initio calculations. Here, we propose MC-PDFT–OPESf as an efficient approach for computing kinetics in strongly correlated molecular systems.

Chemical calculations↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of the iron site localization in doped ZnO

Iron doped (5%) ZnO powders were prepared by hydrothermal and combustion methods. Subsequent heating treatments on these samples were performed under air and also under a reductive atmosphere. Powder XRD, Moessbauer spectroscopy and magnetization studies were used to characterize the products and investigate the localization of iron ions in the ZnO lattice. It was shown that a mixture with a ZnFe{sub 2}O{sub 4} type phase was obtained when the sample was prepared by the hydrothermal method, while Fe{sup 3+} occupy tetrahedral sites of the ZnO lattice in the case of the sample obtained by the combustion method. The magnetic measurements show that no ferromagnetism was detected in the iron doped ZnO compound, neither in the as prepared state nor after reduction. - Graphical abstract: Zn{sub 0.95}Fe{sub 0.05}O obtained by a combustion method and after reduction under hydrogen atmosphere. Highlights: Black-Right-Pointing-Pointer Iron doped ZnO was successfully synthesized by a combustion method. Black-Right-Pointing-Pointer The Fe{sup 3+} tetrahedral coordination was deduced from Moessbauer results. Black-Right-Pointing-Pointer The wurtzite structure was maintained after partial reduction of Fe{sup 3+} to Fe{sup 2+}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Analysis of Inorganic Species in Herbaceous Materials Using Laser-Induced Breakdown Spectroscopy [plus supplemental information]

Inorganic compounds in biomass, often referred to as ash, are known to be problematic in the thermochemical conversion of biomass to bio-oil or syngas and, ultimately, hydrocarbon fuels because they negatively influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. The most common ash-analysis methods, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS), require considerable time and expensive reagents. Laser-induced breakdown spectroscopy (LIBS) is emerging as a technique for rapid analysis of the inorganic constituents in a wide range of biomass materials. This study compares analytical results using LIBS data to results obtained from three separate ICP-OES/MS methods for 12 samples, including six standard reference materials. Analyzed elements include aluminum, calcium, iron, magnesium, manganese, phosphorus, potassium, sodium, and silicon, and results show that concentrations can be measured with an uncertainty of approximately 100 parts per million using univariate calibration models and relatively few calibration samples. These results indicate that the accuracy of LIBS is comparable to that of ICP-OES methods and indicate that some acid-digestion methods for ICP-OES may not be reliable for Na and Al. These results also demonstrate that germanium can be used as an internal standard to improve the reliability and accuracy of measuring many elements of interest, and that LIBS can be used for rapid determination of total ash in biomass samples. Key benefits of LIBS include little sample preparation, no reagent consumption, and the generation of meaningful analytical data instantaneously.

09 BIOMASS FUELS↗

When does atomic resolution plan view imaging of surfaces work?

We present that surface structures that are different from the corresponding bulk, reconstructions, are exceedingly difficult to characterize with most experimental methods. Scanning tunneling microscopy, the workhorse for imaging complex surface structures of metals and semiconductors, is not as effective for oxides and other insulating materials. This paper details the use of transmission electron microscopy plan view imaging in conjunction with image processing for solving complex surface structures. We address the issue of extracting the surface structure from a weak signal with a large bulk contribution. This method requires the sample to be thin enough for kinematical assumptions to be valid. The analysis was performed on two sets of data, c(6×2) on the (100) surface and (3×3) on the (111) surface of SrTiO 3 , and was unsuccessful in the latter due to the thickness of the sample and a lack of inversion symmetry. In conclusion, the limits and the functionality of this method are discussed.

36 MATERIALS SCIENCE↗

Computational methods for probability of instability calculations

This paper summarizes the development of the methods and a computer program to compute the probability of instability of a dynamic system than can be represented by a system of second-order ordinary linear differential equations. Two instability criteria based upon the roots of the characteristics equation or Routh-Hurwitz test functions are investigated. Computational methods based on system reliability analysis methods and importance sampling concepts are proposed to perform efficient probabilistic analysis. Numerical examples are provided to demonstrate the methods.

Wu, Y.-T.↗

Front Delineation and Tracking with Multiple Underwater Vehicles

This work describes a method for detecting and tracking ocean fronts using multiple autonomous underwater vehicles. Multiple vehicles — equally-spaced along the expected frontal boundary — complete near parallel transects orthogonal to the front. Lateral gradients are used to determine the location of the front crossing from each individual vehicle transect by detecting a change in the observed water property. Adaptive control of the vehicles ensure they remain perpendicular to the estimated front boundary as it evolves over time. This method was demonstrated in and around Monterey Bay, California in May of 2017. We compare the front detection method to previously used methods. We introduce a metric in order to evaluate the adaptive control techniques presented. We show the capability of this method for repeated sampling across a dynamic two-dimensional ocean front using short-range Iver AUVs. This method extends to tracking gradients of different properties using a variety of vehicles.

Chavez, Francisco P.↗

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

Measurement of Seebeck coefficient using a large thermal gradient

The integral method of measuring the Seebeck voltage, V(T), has been applied to short rod-shaped samples. In the present method, one end of the sample is held at a fixed temperature and the other end is automatically varied through a temperature T range of interest, up to a maximum temperature of 1000 C. The Seebeck coefficient is then obtained from the slope of the V(T) vs T curve. The method offers simplicity of sample handling and minimal operator involvement.

Wood, C.↗

Dividing the Concentrator Target From the Genesis Mission

The Genesis spacecraft, launched in 2001, traveled to a Lagrangian point between the Earth and Sun to collect particles from the solar wind and return them to Earth. However, during the return of the spacecraft in 2004, the parachute failed to open during descent, and the Genesis spacecraft crashed into the Utah desert. Many of the solar wind collectors were broken into smaller pieces, and the field team rapidly collected the capsule and collector pieces for later assessment. On each of the next few days, the team discovered that various collectors had survived intact, including three of four concentrator targets. Within a month, the team had imaged more than 10,000 fragments and packed them for transport to the Astromaterials Acquisition and Curation Office within the ARES Directorate at JSC. Currently, the Genesis samples are curated along with the other extraterrestrial sample collections within ARES. Although they were broken and dirty, the Genesis solar wind collectors still offered the science community the opportunity to better understand our Sun and the solar system as a whole. One of the more highly prized concentrator collectors survived the crash almost completely intact. The Genesis Concentrator was designed to concentrate the solar wind by a factor of at least 20 so that solar oxygen and nitrogen isotopes could be measured. One of these materials was the Diamond-on-Silicon (DoS) concentrator target. Unfortunately, the DoS concentrator broke on impact. Nevertheless, the scientific value of the DoS concentrator target was high. The Genesis Allocation Committee received a request for approximately 1 cm(sup 2) of the DoS specimen taken near the focal point of the concentrator for the analysis of solar wind nitrogen isotopes. The largest fragment, Genesis sample 60000, was designated for this allocation and needed to be precisely cut. The requirement was to subdivide the designated sample in a manner that prevented contamination of the sample and minimized the risk of losing or breaking the precious requested sample fragment. The Genesis curator determined that the use of laser scribing techniques to "cut" a precise line and subsequently cleave the sample (in a controlled break of the sample along that line) was the best method for accomplishing the sample subdivision. However, there were risks, including excess heating of the sample, that could cause some of the implanted solar wind to be lost via thermal diffusion. Accidentally breaking the sample during the handling and cleaving process was an additional risk. Early in fiscal year 2013, to address this delicate, complicated task, the ARES Directorate assembled its top scientists to develop a cutting plan that would ensure success when applied to the actual concentrator target wafer; i.e., to produce an approximately 1 cm(sup 2) piece from the requested area of the wafer. The team, subsequently referred to as the JSC Genesis Tiger Team, spent months researching and testing parameters and techniques related to scribing, cleaving, transporting, handling, and holding (i.e., mounting) the specimen. The investigation required considerable "thinking outside the box," and many, many trials using nonflight wafer analogs. After all preliminary testing, the following method was adopted as the final cutting plan. It was used in two final end-to-end practice runs before being used on the actual flight target wafer. The wafer was oriented on the laser cutting stage with the 100 and 010 directions of the wafer parallel to the corresponding X and Y directions of the cutting stage. The laser was programed to scribe 31 lines of the appropriate length along the Y stage direction. The programed scribe lines were separated by 5 micron in the X direction. The laser parameters were set as follows: (1) The laser power was 0.5 watts; (2) each line consisted of 50 passes, with the Z position being advanced 5 micron per pass; and (3) 30 s would elapse before the next line was scribed to allow for wafer cool down from any possible heating via the laser. The ablated material that "stuck" in the "scribe-cut" was removed from the "cut" using an ultrasonic micro-tool. After all the ablated silicon was removed from the wafer, the wafer was repositioned in exactly the same orientation on the laser stage. The laser was focused using the bottom of the wafer channel, and the 31-line scribing pattern described above was reprogrammed using the Z position of the groove bottom as the starting Z value instead of the top wafer surface, which was used previously. Upon completion of the second set of scribes, the ultrasonic micro-tool was again used to clean out the cut. The wafer was remounted on the stage in exactly the same orientation as before. The laser was again focused on the bottom of the groove. This time, however, the laser was.programed to scribe only one line down the exact center of the channel. The final scribe line consisted of 100 passes with a Z advance of 5 micron per pass and with the laser power set at 0.5 watts. As mentioned above, the final cutting plan was practiced in two end-to-end trials using non-flight, triangular-shaped silicon wafers similar in size and orientation to the actual DOS 60000 target sample. The actual scribing of the triangular-shaped wafers required scribing two lines and cleaving (i.e. scribe-cleave, then scribe-cleave) to obtain the piece requested for allocation. Early in December 2012, after many months of experiments and practicing and perfecting the techniques and procedures, the team successfully subdivided the Genesis DoS 60000 target sample, one of the most scientifically important samples from the Genesis mission (figure 2). On December 17, 2012, the allocated piece of concentrator target sample was delivered to the requesting principal investigator.The cutting plan developed for the subdivision of this sample will be used as the model for subdividing future requested Genesis flight wafers (appropriately modified for different wafer types).

Lauer, H. V., Jr.↗

XPS guide: Charge neutralization and binding energy referencing for insulating samples

This guide deals with methods to control surface charging during XPS analysis of insulating samples and approaches to extracting useful binding energy information. Furthermore, the guide summarizes the causes of surface charging, how to recognize when it occurs, approaches to minimize charge buildup, and methods used to adjust or correct XPS photoelectron binding energies when charge control systems are used. Additionally, there are multiple ways to control surface charge buildup during XPS measurements and examples of systems on advanced XPS instruments are described. There is no single, simple, and foolproof way to extract binding energies on insulating material, but advantages and limitations of several approaches are described. Because of the variety of approaches and limitations of each it is critical for researchers to accurately describe the procedures that have been applied in research reports and publications.

47 OTHER INSTRUMENTATION↗

Towards a novel stellar opacity measurement scheme using stability properties of double ablation front structures

A novel method for bringing sample elements to hydrodynamic conditions relevant to the base of the solar convection zone is investigated. The method is designed in the framework of opacity measurements and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures. The physics of symmetric DAF structures is first studied in 1D geometries to assess the influence of tracer layers in the target. These results are used to propose an experimental design compatible with the OMEGA [Boehly et al., Opt. Commun. 133(1-6), 495–506 (1997)] laser. Radiative-hydrodynamic simulations conducted using the Chic code [Breil et al., Comput. Fluids 46, 161–167 (2011).] in 2D-axisymmetric geometries suggest that a Fe sample can be brought to an electron temperature of ∼160 eV and electron number density of ∼1.35 × 1023 cm−3. These parameters are reached during a 500 ps window with temporal variations of the order of 10 eV and 1022 cm−3, respectively. This allows for potential time-integrated spectral measurements. During that time, the sample is almost at local thermal equilibrium and 2D spatial gradients in the sample are less than 5% in a 360 μm diameter cylindrical volume, including the potential effects of Hot Electrons (HE) and typical uncertainties related to target fabrication and laser performances. The effects of HEs are assessed using an inline model in Chic. The HEs are found to deposit most of their energy in the cold and dense ablator between the two fronts, leading to a small efficiency loss on the DAF parameters. The calculations also suggest that negligible amounts of unabsorbed HEs are present in the probed volume, thus not affecting the atomic properties of the sample. Potential extensions of the current design to higher sample temperatures within the OMEGA capabilities are briefly discussed.

Colaïtis, A.↗

A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy

Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi 2 Te 3 samples in the temperature range of 30–150 °C with an error below 3%.

47 OTHER INSTRUMENTATION↗

Performance Evaluation of Fast Microfluidic Thermal Lysis of Bacteria for Diagnostic Sample Preparation

Development of new diagnostic platforms that incorporate lab-on-a-chip technologies for portable assays is driving the need for rapid, simple, low cost methods to prepare samples for downstream processing or detection. An important component of the sample preparation process is cell lysis. In this work, a simple microfluidic thermal lysis device is used to quickly release intracellular nucleic acids and proteins without the need for additional reagents or beads used in traditional chemical or mechanical methods (e.g., chaotropic salts or bead beating). On-chip lysis is demonstrated in a multi-turn serpentine microchannel with external temperature control via an attached resistive heater. Lysis was confirmed for Escherichia coli by fluorescent viability assay, release of ATP measured with bioluminescent assay, release of DNA measured by fluorometry and qPCR, as well as bacterial culture. Results comparable to standard lysis techniques were achievable at temperatures greater than 65 °C and heating durations between 1 and 60 s.

lab-on-a-chip↗

Controllable Thin‐Film Approaches for Doping and Alloying Transition Metal Dichalcogenides Monolayers

Abstract Two‐dimensional (2D) transition metal dichalcogenides (TMDs) exhibit exciting properties and versatile material chemistry that are promising for device miniaturization, energy, quantum information science, and optoelectronics. Their outstanding structural stability permits the introduction of various foreign dopants that can modulate their optical and electronic properties and induce phase transitions, thereby adding new functionalities such as magnetism, ferroelectricity, and quantum states. To accelerate their technological readiness, it is essential to develop controllable synthesis and processing techniques to precisely engineer the compositions and phases of 2D TMDs. While most reviews emphasize properties and applications of doped TMDs, here, recent progress on thin‐film synthesis and processing techniques that show excellent controllability for substitutional doping of 2D TMDs are reported. These techniques are categorized into bottom–up methods that grow doped samples on substrates directly and top–down methods that use energetic sources to implant dopants into existing 2D crystals. The doped and alloyed variants from Group VI TMDs will be at the center of technical discussions, as they are expected to play essential roles in next‐generation optoelectronic applications. Theoretical backgrounds based on first principles calculations will precede the technical discussions to help the reader understand each element's likelihood of substitutional doping and the expected impact on the material properties.

36 MATERIALS SCIENCE↗