Search NASASearch

SEARCH · Search NASA

Results for “(SIM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparisons of triple-differential cross sections for quasielastic-like $ν_μ$-hydrocarbon interactions using $\langle E_ν\rangle \sim$ 3~GeV versus $\sim$ 6~GeV beams in MINERvA

Neutrino charged-current quasielastic-like scattering, a reaction category extensively used in neutrino oscillation measurements, receives contributions from single nucleon knockout processes, multinucleon processes, and inelastic scattering with subsequent rescattering or absorption in the nucleus to produce only nucleons in the final state. In this article, comparisons are presented of the same measurement in two different wideband neutrino beams: one beam peaks near 3 GeV with few neutrinos above 6 GeV; the other peaks near 6 GeV with few neutrinos above 10 GeV. Comparisons of differential cross sections in muon and proton kinematics for these two exposures probe deviations from free-neutron scattering that arise from the processes involving the nuclear medium, and provide a test of neutrino interaction models used to infer neutrino energies in oscillation experiments. Discrepancies are observed between the data and predictions that point to overestimates of the final state interactions of both protons and charged pions in quasielastic-like events.

Ruterbories, D. [Rochester U.]

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Investigating intermolecular interactions among CO 2 , water and PEEK-ionene membrane using cryo ToF-SIMS and isotopic labeling

Cryogenic time-of-flight secondary ion mass spectrometry (cryo ToF-SIMS) has emerged as a powerful tool for investigating molecular interactions, speciation, and dynamics in materials for CO 2 capture. In this study, we apply cryo ToF-SIMS to probe interactions between CO 2 , water, and PEEK-ionene membranes—a promising material for direct CO 2 capture due to its selectivity, durability, and efficiency. Despite this potential, the mechanisms governing CO 2 diffusion and the influence of water vapor on CO 2 behavior remain unclear. To address this, we loaded PEEK-ionene membranes with 13 CO 2 and D 2 O and employed cryo ToF-SIMS to visualize the 3D distribution of CO 2 and water within the membrane. While prior studies suggest that 13 CO 2 is absorbed under ambient conditions, our cryo ToF-SIMS analysis revealed no enhancement of the 13 C/ 12 C ratio, suggesting weak CO 2 -membrane interactions. As a result, CO 2 vaporizes even at low temperatures (−140°C) under vacuum conditions. In contrast, D 2 O displayed a relatively homogeneous distribution in the membrane, suggesting stronger water-membrane interactions via hydrogen bonding (18–20 kJ/mol). Interestingly, CO 2 was not detected in D 2 O-loaded membranes, indicating minimal interference from water vapor on CO 2 diffusion. As a comparison, the cryo ToF-SIMS data show that 13 CO 2 can readily react with a basic Na 2 CO 3 aqueous solution to form NaH 13 CO 3 . These findings demonstrate cryo ToF-SIMS as a critical technique for understanding gas-water-membrane interactions, offering insights for membrane functionalization to improve CO 2 capture efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

ToF-SIMS spectral analysis of Shewanella oneidensis MR-1 biofilms

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many powerful features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution, mass resolution, and mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Shewanella oneidensis MR-1 isolated from freshwater lake sediment in New York state. The MR-1 strain is known to have metal and sulfur reducing properties and it can be used for bioremediation and wastewater treatment. There is a current need to identify small molecules and fragments produced from bacterial biofilms, especially those from extracellular polymeric substance (EPS). Static ToF-SIMS spectra of MR-1 were obtained using an IONTOF TOF.SIMS V instrument equipped with a 25 keV Bi$^+_3$ metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids, fatty acids, flavonoids, and quinolones to other naturally occurring organic compounds. It is anticipated that the mass spectral identification of key peaks will assist detection of metabolites, EPS molecules like polysaccharides, and biologically relevant small organic molecules using ToF-SIMS in future surface and interface research.

59 BASIC BIOLOGICAL SCIENCES

Studying microbially induced corrosion on glass using ToF-SIMS

Microbially induced corrosion (MIC) is an emerging topic that has huge environmental impacts, such as long-term evaluation of microbial interactions with radioactive waste glass, environmental cleanup and disposal of radioactive material, and weathering effects of microbes. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), a powerful mass spectral imaging technique with high surface sensitivity, mass resolution, and mass accuracy, can be used to study biofilm effects on different substrates. Understanding how to prepare biofilms on MIC susceptible substrates is critical for proper analysis via ToF-SIMS. We present here a step-by-step protocol for preparing bacterial biofilms for ToF-SIMS analysis, comparing three biofilm preparation techniques: no desalination, centrifugal spinning (CS), and water submersion (WS). Comparisons of two desalinating methods, CS and WS, show a decrease in the media peaks up to 99% using CS and 55% using WS, respectively. Proper desalination methods also can increase biological signals by over four times for fatty acids using WS, for example. ToF-SIMS spectral results show chemical compositional changes of the glass exposed in a Paenibacillus polymyxa SCE2 biofilm, indicating its capability to probe microbiologically induced corrosion of solid surfaces. This represents the proper desalination technique to use without significantly altering biofilm structure and substrate for ToF-SIMS analysis. ToF-SIMS spectral results showed chemical compositional changes of the glass exposed by a Paenibacillus bacterial biofilm over 3-month inoculation. Finally, possible MIC products include various phosphate phase molecules not observed in any control samples with the highest percent increases when experimental samples were compared with biofilm control samples.

36 MATERIALS SCIENCE

Review of recent WEC-Sim (v6.1) advanced features

WEC-Sim (Wave Energy Converter SIMulator) is an opensource software for modeling the motions, loads and power generation of wave energy converters. WEC-Sim performs simulations in the time domain using hydrodynamic coefficients calculated by boundary element method (BEM) frequency-domain potential flow solvers such as WAMIT, NEMOH, Capytaine, or Ansys AQWA. WEC-Sim development is ongoing, including various features, applications, and example cases used to demonstrate potential use-cases to meet the needs of the growing marine energy industry. Through input from a broad user base and an extensive team of developers and collaborators, new features of WEC-Sim are developed to expand the software’s use cases and improve overall functionality. Three new WEC-Sim features highlighted in this paper include updating WEC-Sim to be compatible with MoorDyn Version 2, incorporation of second order excitation loads (quadratic transfer functions) and allowing for dynamically changing hydrodynamics.

13 HYDRO ENERGY

Machine Learning Correlation of Electron Micrographs and ToF-SIMS for the Analysis of Organic Biomarkers in Mudstone

The spatial distribution of organics in geological samples can be used to determine when and how these organics were incorporated into the host rock. Mass spectrometry (MS) imaging can rapidly collect a large amount of data, but ions produced are mixed without discrimination, resulting in complex mass spectra that can be difficult to interpret. Here, we apply unsupervised and supervised machine learning (ML) to help interpret spectra from time-of-flight-secondary ion mass spectrometry (ToF-SIMS) of an organic-carbon-rich mudstone of the Middle Jurassic of England (UK). It was previously shown that the presence of sterane molecular biomarkers in this sample can be detected via ToF-SIMS (Pasterski, M. J. et al., Astrobiology 2023, 23, 936). We use unsupervised ML on scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) measurements to define compositional categories based on differences in elemental abundances. We then test the ability of four ML algorithms─k-nearest neighbors (KNN), recursive partitioning and regressive trees (RPART), eXtreme gradient boost (XGBoost), and random forest (RF)─to classify the ToF-SIM spectra using (1) the categories assigned via SEM-EDS, (2) organic and inorganic labels assigned via SEM-EDS, and (3) the presence or absence of detectable steranes in ToF-SIMS spectra. In terms of predictive accuracy and balanced accuracy, KNN was the best performing model and RPART the worst. The feature importance, or the specific features of the ToF-SIM spectra used by the models to make classifications, cannot be determined for KNN, preventing posthoc model interpretation. Nevertheless, the feature importance extracted from the other models was useful for interpreting spectra. In conclusion, we determined that some of the organic ions used to classify biomarker containing spectra may be fragment ions derived from kerogen which is abundant in this mudstone sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Laboratory Upgrade Point Absorber WEC-Sim Model with MoorDyn Moorings

This dataset includes a WEC-Sim and MoorDyn model of the Laboratory Upgrade Point Absorber (LUPA). LUPA is an open-source wave energy converter designed and tested by Oregon State University. The files provided here constitute a stable LUPA configuration with three mooring lines. This model is 1/20 scale, optimized for the O.H. Hinsdale Wave Lab at Oregon State University. This model of LUPA adds MoorDyn functionality for more accurate mooring predictions and uses a more stable, updated version of LUPA's current physical configuration. This model is for WEC-Sim Version 6.0. A recent update of WEC-Sim has changed some functionality of MoorDyn such that this model will not work with WEC-Sim Version 6.1.

16 TIDAL AND WAVE POWER

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE

60 years of science in ICF: from conception to scientific breakeven on the National Ignition Facility

The recent achievements of a burning plasma, fusion ignition, and scientific energy gain with deuterium-tritium (DT) fuel at Lawrence Livermore National Laboratory’s National Ignition Facility (NIF) represents a major milestone in the development of inertial confinement fusion (ICF) and all of fusion research. In these experiments, fuel pressures well in excess of hundreds of GBars were achieved in the compressed fuel, and robust alpha heating of the fuel, far in excess of the energy provided by the implosion, were demonstrated for the first time. These achievements occurred 60 years after the inception of ICF and the first laser demonstration, and were made possible by more than five decades of research at laser facilities around the world. Advances in laser technology both in wavelength and precision, motivated by improved understanding of laser-plasma interaction physics and the demands of targets; improvements in target fabrication inspired by the need to control and minimize hydrodynamic instabilities in the implosion; and multi-dimensional simulations and diagnostics have been critical to this achievement. This paper will summarize the scientific and technical advances, the surprises, and the challenges that had to be overcome to achieve these goals.

fusion

Combining ToF‐SIMS and Multivariate Analysis to Resolve Active Sites on Ni‐Based HER Catalysts

Unambiguous identification of active sites in heterogeneous catalysis remains a major challenge, particularly for materials with ultrathin, chemically mixed surface layers. Here, we demonstrate a generalizable approach that combines time-of-flight secondary ion mass spectrometry (ToF-SIMS) with multivariate statistical analysis (principal component analysis [PCA] and multivariate curve resolution [MCR]) to resolve catalytically relevant motifs at the nanoscale. Using Ni electrodes as a model system, PCA distinguished hydroxide-enriched domains from oxide- and metal-rich regions, while MCR decomposed depth profiles and 3D images into hydroxide, oxide, and metallic layers with nanometer resolution. A unique secondary-ion fragment, NiO 3 H 3 − (m/z 108.94), emerged as a marker of hydroxide-rich environments and correlated with hydrogen evolution reaction (HER) activity across a series of Ni electrodes. Complementary density functional theory (DFT) calculations revealed that Ni(OH) 2 clusters adjacent to metallic Ni offer the most favorable water dissociation energetics, establishing the structural origin of the marker. While illustrated here for Ni-based HER, this workflow provides a broadly applicable framework to isolate and rank near-surface patterns that govern catalytic activity, thereby extending ToF-SIMS from a qualitative probe to a predictive tool for active site identification.

HER active sites

WEC-SIM Support for an Innovative Zero Discharge Supercritical Water Based Wave Energy Desalination System (CRADA Final Report)

NREL will assist East Carolina University in its development of the foundational knowledge and proof of concept that are needed for future process scale up and commercialization of a sustainable wave-to-water (direct pressurization) desalination unit powered by a wave energy converter. NREL will provide guidance and support to East Carolina University on its: use of the NREL developed WEC-Sim based wave to water system, exploring the WEC-Sim/ASPEN Plus data exchange communication, and using experimental data to hopefully provide validation of analytical models.

16 TIDAL AND WAVE POWER

Safeguards Technology Program FY2026 Mid-Year Report for Project WBS# 24.1.3.3: Development of Procedures for Th-U Radiochronometry of Uranium Particles by LG-SIMS

Implementing 230 Th- 234 U radiochronometry of environmental uranium particles by large geometry secondary ion mass spectrometry (LG-SIMS) requires assessment, validation, and technical support before safeguards conclusions can be drawn from the information. This project investigates the most challenging aspects of LG-SIMS particle radiochronometry 230 Th- 234 U measurements through a collaboration between LANL and NIST, to provide best practices and procedures for determining high quality ages with optimized uncertainties. This includes exploration of reducing detector backgrounds, investigating the best ways to report uncertainties, and establishing recommended instrument setups.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

WEC-Sim Modeling of Laminar Scientific's Patented Seesaw Wave Energy Converter: Preprint

Laminar Scientific's patented seesaw wave energy converter was modeled in WEC-Sim to predict performance. The device operates by utilizing ocean surface waves to rotate a truss in pitch about a pivot. The pivot is located at the top of two pylons, which are embedded in the seafloor. The seesaw has a float on either end, and the buoyancy forces from each float cause the system to rise or fall with passing waves. Device performance relies upon seesaw length and ocean wavelength creating an antiphase effect. The seesaw truss has an adjustable length intended to achieve this effect. The operation method enforces a narrow band of wavelengths which induce the largest rotational motion from the device. The hydrodynamic analysis of the device was performed using Capytaine, and the results confirmed that the device operates best in a narrow frequency band. Four float-to-float spacing cases and three pylon radii were examined. The hydrodynamic results indicate a match between the model and the physical expectations for the device, and that varying the pylon radii by 0.1-m increments for three instances creates minimal changes in hydrodynamic properties. Power matrices for three float spacing cases of the device were simulated with Joint North Sea Wave Project spectra waves and optimal power take-off damping in WEC-Sim. The maximum average power production for the 15-m spacing case was 14.1 kW with a 5.0-s peak wave period and 4-m significant wave heights. Plots of capture-width ratios indicated that the device performance was linear and confirmed that the device is optimal in a narrow frequency band. The maximum percentage of the available wave power produced by the 15-m device was approximately 16%. Simulations of the device in regular waves were used to produce plots of average power compared to a ratio of float spacing to wavelength. These plots indicate that the power production is maximized at a ratio of 0.5, and further confirm that the device has a narrow frequency response. The device was simulated at an example field location, where the device produced an annual average power rating of 1.6 kW given an average omnidirectional wave climate of 10.3 kW m-1 and an optimal, linearized power take-off model. While the maximum predicted device performance is reliant upon a narrow band of wave frequencies, the conducted analysis provides an opportunity to improve device design prior to prototyping and testing. Modifying the design to respond to a broader frequency range would improve device performance.

numerical modeling

Sim-to-real supervised domain adaptation for radioisotope identification

Machine learning has the potential to improve the speed and reliability of radioisotope identification using gamma spectroscopy. However, meticulously labeling an experimental dataset for training is often prohibitively expensive, while training models purely on synthetic data is risky due to the domain gap between simulated and experimental measurements. In this research, we demonstrate that supervised domain adaptation can substantially improve the performance of radioisotope identification models by transferring knowledge between synthetic and experimental data domains. We consider two domain adaptation scenarios: (1) a simulation-to-simulation adaptation, where we perform multi-label proportion estimation using simulated high-purity germanium detectors, and (2) a simulation-to-experimental adaptation, where we perform multi-class, single-label classification using measured spectra from handheld lanthanum bromide (LaBr) and sodium iodide (NaI) detectors. We begin by pretraining a spectral classifier on synthetic data using a custom transformer-based neural network. After subsequent fine-tuning on just 64 labeled experimental spectra, we achieve a test accuracy of 96% in the sim-to-real scenario with a LaBr detector, far surpassing a synthetic-only baseline model (75%) and a model trained from scratch (80%) on the same 64 spectra. Furthermore, we demonstrate that domain-adapted models learn more human-interpretable features than experiment-only baseline models. Overall, our results highlight the potential for supervised domain adaptation techniques to bridge the sim-to-real gap in radioisotope identification, enabling the development of accurate and explainable classifiers even in real-world scenarios where access to experimental data is limited.

Lalor, Peter W.

Observation of N-rich solid-electrolyte interphase by ToF-SIMS.

Formation of a stable solid electrolyte interphase (SEI) between lithium electrodes and electrolyte upon multiple charge/discharge cycles is crucial to a long-term lithium-ion battery performance. Addition of LiNO3 to lithium bis (fluorosulfonyl) imide/poly(ethylene oxide) (LiFSI/PEO) electrolyte leads to a durable SEI that is electrically insulating yet highly conductive to Li ions, chemically and electrochemically stable, physically uniform, and mechanically robust. ToF-SIMS was used here in combination with sputtering by a gaseous cluster ion beam (GCIB) to examine how the addition of a small proportion of LiNO3 to the LiFSI/PEO electrolyte affects the SEI composition. Negative ion ToF-SIMS spectra of the cycled samples display an intense m/z 26 peak associated with the SEI. Exact mass assignments and isotopic ratios indicate that this peak should be assigned as (CN-)-C-12, with little to no negative secondary ion signal arising from (LiF-)-Li-7. This CN- signal appears to arise from an N-rich portion of the SEI adjacent to the Li electrode that is depleted in LiF relative to the bulk electrolyte. The dearth of LiF- (and LiF+ from the positive ion spectra) is unexpected because LiF has been identified in the SEI in similar samples. Finally, GCIB sputtering indicates that the SEI adheres more strongly to the Li electrode than to the LiFSI/PEO electrolyte.

Shavandi, Seyedeh Reyhaneh