Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

3D analysis of TRISO fuel compacts via X-ray computed tomography

In this study, low-enriched uranium oxycarbide (LEUCO) and surrogate tristructural isotropic (TRISO)- coated-particle compacts with particle volumetric packing fractions of 25%, 40%, and 48% were imaged utilizing X-ray-computed tomography. Subsequent 3D image analysis identified and further quantified kernel size, sphericity, and observed porosity. In addition, the spatial distribution, coordination number, and kernel-nearest neighbors were analyzed and compared for the different packing fractions. Metrics such as observed porosity and sphericity enabled quantification and screening for abnormal kernels within TRISO compacts. Assessment of TRISO particle location confirmed and further quantified a non-uniform distribution of TRISO particles with the spatial distribution in the radial direction being roughly described as a dampened sinusoidal function. The amplitude and frequency of this non-uniform distribution increased with increasing packing fraction. Measured kernel-nearest neighbor distances indicated two regions along the radial surfaces of compacts where TRISO particles are more likely to be in intimate contact with one another. These regions were found: (1) at upper and lower faces of compacts (i.e., corners); (2) offset ~10% of a compact's length from the axial center near the exterior surface. Within these regions, small quantities of defective TRISO surrogate particles (48% packing fraction) and defective LEUCO TRISO particles (40% packing fraction) were found. No defective particles were found within 25% packing fraction LEUCO TRISO compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupling of multiscale imaging analysis and computational modeling for understanding thick cathode degradation mechanisms

Here, using a thick NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 ) electrode as an example, we present a macro- to nanoscale 2D and 3D imaging analysis approach coupled with 4D (space + time) computational modeling to probe its degradation mechanism in a lithium-ion battery cell. Particle cracking increases and contact loss between particles and carbon-binder domain are observed to correlate with the cell degradation. This study unravels that the reaction heterogeneity within the thick cathode caused by the unbalanced electron conduction is the main cause of the battery degradation over cycling. The increased heterogeneity in the system will entail more cathode regions where the degree of active material utilization is uneven, leading to higher probabilities of particle cracking. These findings shed light on the crucial role of the electronic and ionic transportation networks in the performance deterioration of the thick cathode. They also provide guidance for cathode architecture optimization and performance improvement.

25 ENERGY STORAGE↗

Genetic interactions between polycystin-1 and Wwtr1 in osteoblasts define a novel mechanosensing mechanism regulating bone formation in mice

Molecular mechanisms transducing physical forces in the bone microenvironment to regulate bone mass are poorly understood. Here, we used mouse genetics, mechanical loading, and pharmacological approaches to test the possibility that polycystin-1 and Wwtr1 have interdependent mechanosensing functions in osteoblasts. We created and compared the skeletal phenotypes of control Pkd1 flox/+ ;Wwtr1 flox/+ , Pkd1 Oc-cKO , Wwtr1 Oc-cKO , and Pkd1/Wwtr1 Oc-cKO mice to investigate genetic interactions. Consistent with an interaction between polycystins and Wwtr1 in bone in vivo, Pkd1/Wwtr1 Oc-cKO mice exhibited greater reductions of BMD and periosteal MAR than either Wwtr1 Oc-cKO or Pkd1 Oc-cKO mice. Micro-CT 3D image analysis indicated that the reduction in bone mass was due to greater loss in both trabecular bone volume and cortical bone thickness in Pkd1/Wwtr1 Oc-cKO mice compared to either Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Pkd1/Wwtr1 Oc-cKO mice also displayed additive reductions in mechanosensing and osteogenic gene expression profiles in bone compared to Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Moreover, we found that Pkd1/Wwtr1 Oc-cKO mice exhibited impaired responses to tibia mechanical loading in vivo and attenuation of load-induced mechanosensing gene expression compared to control mice. Finally, control mice treated with a small molecule mechanomimetic, MS2 that activates the polycystin complex resulted in marked increases in femoral BMD and periosteal MAR compared to vehicle control. In contrast, Pkd1/Wwtr1 Oc-cKO mice were resistant to the anabolic effects of MS2. These findings suggest that PC1 and Wwtr1 form an anabolic mechanotransduction signaling complex that mediates mechanical loading responses and serves as a potential novel therapeutic target for treating osteoporosis.

60 APPLIED LIFE SCIENCES↗

DEEPER: An Intergrated Platform for Deeper Roots

Crops with deeper roots would have multiple benefits, including better drought tolerance, reduced requirement for nitrogen fertilizer, and better sequestration of atmospheric CO 2 . DEEPER is an integrated platform of phenomic, genomic, and in silico technologies to generate maize lines with deeper roots. DEEPER is: LEADER (Leaf Elemental Accumulation from Deep Roots) is a breakthrough technology to nondestructively measure rooting depth by using the plant itself as a sensor. LEADER uses handheld X-ray Fluorescence spectrometry to quantify foliar accumulation of elements that are differentially distributed in the soil profile. LEADER is nondestructive and is orders of magnitude cheaper, faster, and more precise than any competing assay of rooting depth in the field. LEADER is able to distinguish deep-rooted from shallow-rooted maize lines in the field without the need for costly and noisy soil coring. RootRobot/DIRT3D, to automatically phenotype root architecture in any field, combining RootRobot, a mechatronics platform to excavate, clean, section, and image mature root crowns, with DIRT3D, software to quantify architectural traits in 3D. Anatomics, a high-throughput platform to phenotype root anatomy, combining LAT 2.0, a technology for 3D imaging of root anatomy and composition, with RootScan3D, software to automatically extract 3D anatomical and cell wall composition metrics from LAT 2.0 output. Using this platform we discovered two novel root traits, parenchyma cell wall thickness and multiseriate cortical sclerenchyma, that improve rooting depth and drought tolerance in maize and wheat. OpenSimRoot/Deep, software to simulate root interaction with hard subsoils. Using this platform we discovered novel concepts regarding how to increase crop rooting depth by modulating how individual root axes respond to hard soil. DeepGenes, a toolkit of genes, parent lines, and genomic selection strategies to enable breeding hybrids with deeper roots. We discovered 3 novel root genes that increase rooting depth in maize and wheat. DEEPER discovered novel root phenotypes for deeper rooting, and delivered validated ideotypes for deeper-rooted maize; novel technologies to rapidly assess root depth, root architecture and anatomy in field-grown plants; novel software tools for root modeling and 3D image analysis of root architecture and anatomy; and validated genes and genomic selection models to deploy traits for deeper rooting in maize breeding. Each DEEPER technology is transformative in its own right, and exceeds existing technologies. They are mutually synergistic, deployable for field-grown plants, and are ready for application. The phenotyping and modeling technologies are readily applicable to many crops, and genetic leads in maize may have utility in other grasses. Taken as a whole they represent a transformative platform to develop deeper-rooted crops, with greater drought tolerance, reduced fertilizer requirement, and greater carbon sequestration.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of autogenous shrinkage-induced microcracks in concrete from 3D images

A new image analysis procedure for quantifying microcracks from three-dimensional (3D) X-ray microCT images of concrete is presented. The method separates microcracks from air voids and aggregates by combining filtering and morphological operations. It was applied to study the effects of supplementary cementitious materials (SCMs) and curing age on autogenous shrinkage-induced microcracks in low w/b ratio concretes, and to determine the representative elementary volume (REV) for various properties of microcracks and air voids. Results showed that slag and silica fume significantly increased autogenous shrinkage and related microcracking. These SCMs increased volume fraction, width, length, dendritic density, anisotropy, and connectivity of microcracks, but decreased specific surface and tortuosity. Similar trends were observed with age. Comparison between 3D and 2D measurements was made. REV analysis showed that a sampling volume of ~20 × 20 × 25 mm{sup 3} is sufficient for characterising most parameters of autogenous shrinkage microcracks and air voids in concrete.

36 MATERIALS SCIENCE↗

Extrusion parameter control optimization for DIW 3D printing using image analysis techniques

Material extrusion is a well-recognized facet of additive manufacturing that involves the fabrication of parts through the deposition of structural material from an extrusion head from a bulk supply. In the subdivision of Direct Ink Writing (DIW) additive manufacturing, challenges arise when the structural material is flowable, synchronous extrusion control and tool movement becomes critical for achieving high-quality parts with low defect populations. DIW techniques are most used in laboratory settings using expensive custom instruments and may require specialized 3D slicing software. Here, in this study, the fabrication of an inexpensive, consumer-friendly progressive cavity pump dispensing system is detailed, in which can create high-quality parts by executing G-code commands produced from a commercial slicing software. The precision and repeatability of the movement-synchronized material extrusion is demonstrated through a series of optimization schemes, entailing the alteration of various control parameters, which directly affect the extrusion properties demonstrated during a print. In situ diagnostics were implemented to evaluate the results of the established optimization experiment. Using a machine vision technique, images of the optimization prints are processed. Following this, a supervised machine learning model was trained to autonomously judge whether or not the extrusion parameters produced a passing or failing result. The machine learning scheme serves as a preliminary benchmark for future layer-by-layer evaluation of more complex DIW parts. The construction of the printer and development of in situ characterization capabilities demonstrates the ability for this printer to create high-fidelity DIW parts for a fraction of the price of other systems.

42 ENGINEERING↗

Secondary porosity prediction in complex carbonate reefs using 3D CT scan image analysis and machine learning

Development and preservation of carbonate porosity and permeability are critical to characterizing reservoirs. However, secondary porosity, such as vugs and fractures, are difficult to identify and require collection of expensive wireline tools or core sampling. Wireline logs and cores have traditionally been used to identify the presence of secondary porosity but fail to quantify the contribution to total reservoir porosity. Additionally, advanced wireline logs and core are not readily available for most wells. Dual energy CT scans were collected on whole core from the A-1 Carbonate and Brown Niagaran formations drawn from six wells in northern Michigan. 3D analysis techniques were applied to identify and isolate secondary porosity features. A series of machine learning and data analytics techniques were applied to the dataset to predict secondary porosity features on basic wireline logs. The predictive model successfully predicted secondary porosity with high confidence.

02 PETROLEUM↗

Segmentation of tomography datasets using 3D convolutional neural networks

Dendritic microstructures are ubiquitous in nature and are the primary solidification morphologies in metallic materials. Techniques such as X-ray computed tomography (XCT) have provided new insights into dendritic phase transformation phenomena. However, manual identification of dendritic morphologies in microscopy data can be both labor intensive and potentially ambiguous. The analysis of 3D datasets is particularly challenging due to their large sizes (terabytes) and the presence of artifacts scattered within the imaged volumes. Here, in this study, we trained 3D convolutional neural networks (CNNs) to segment 3D datasets. Three CNN architectures were investigated, including a new version of FCDenseNet which we extended to 3D. We show that using hyperparameter optimization (HPO) and fine-tuning techniques, both 2D and 3D CNN architectures outperform the previous state of the art. The 3D U-Net architecture trained in this study produced the best segmentations according to quantitative metrics (intersection-over-union of 95.56% and a boundary displacement error of 0.58 pixels), while 3D FCDense produced the smoothest boundaries and best segmentations according to visual inspection. The trained 3D CNNs are able to segment entire 852 × 852 × 250 voxel 3D volumes in only ~60 s, thus hastening the progress towards a deeper understanding of phase transformation phenomena such as dendritic solidification.

36 MATERIALS SCIENCE↗

Nanopore networks in colloidal silica assemblies characterized by XCT for confined fluid flow modeling

Fluid flow through nanopore structures has exhibited different behavior than that described by Darcy's law, derived from pore networks of micrometer scale. Here, pressure assemblies of colloidal silica spheres of specified diameters from 94 to 620 nanometers were prepared as model nano-porous media. The smaller silica spheres tended to form random packing, but some substantial ordering was found in the packing of the larger silica spheres. X-ray computed tomography (XCT), with a voxel resolution of 16 nm, was used to characterize the nanopore networks. The porosity of the Nano-XCT pore network (34%) was less than the total porosity of the assemblies as determined by X-ray attenuation (52%), possibly due to the limits of voxel resolution during segmentation. Fluid flow in the nanopore networks was simulated using the single-phase Lattice Boltzmann Method, and the simulated permeability was compared with the empirical and experimental values. Based on our characterization, although a well-ordered packing of silica spheres was not achieved, it was found that the nanopore networks in the colloidal silica assemblies had pore size distributions corresponding to the particle sizes. The simulated permeability was less than the experimental measurement for water flow, but the complex packing of silica spheres and surface chemistry issues need to be considered in future research.

02 PETROLEUM↗

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Seeking regularity from irregularity: unveiling the synthesis–nanomorphology relationships of heterogeneous nanomaterials using unsupervised machine learning

Nanoscale morphology of functional materials determines their chemical and physical properties. However, despite increasing use of transmission electron microscopy (TEM) to directly image nanomorphology, it remains challenging to quantify the information embedded in TEM data sets, and to use nanomorphology to link synthesis and processing conditions to properties. We develop an automated, descriptor-free analysis workflow for TEM data that utilizes convolutional neural networks and unsupervised learning to quantify and classify nanomorphology, and thereby reveal synthesis–nanomorphology relationships in three different systems. While TEM records nanomorphology readily in two-dimensional (2D) images or three-dimensional (3D) tomograms, we advance the analysis of these images by identifying and applying a universal shape fingerprint function to characterize nanomorphology. After dimensionality reduction through principal component analysis, this function then serves as the input for morphology grouping through unsupervised learning. We demonstrate the wide applicability of our workflow to both 2D and 3D TEM data sets, and to both inorganic and organic nanomaterials, including tetrahedral gold nanoparticles mixed with irregularly shaped impurities, hybrid polymer-patched gold nanoprisms, and polyamide membranes with irregular and heterogeneous 3D crumple structures. In each of these systems, unsupervised nanomorphology grouping identifies both the diversity and the similarity of the nanomaterial across different synthesis conditions, revealing how synthetic parameters guide nanomorphology development. Our work opens possibilities for enhancing synthesis of nanomaterials through artificial intelligence and for understanding and controlling complex nanomorphology, both for 2D systems and in the far less explored case of 3D structures, such as those with embedded voids or hidden interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemically Induced Strain Evolution in Pt–Ni Alloy Nanoparticles Observed by Bragg Coherent Diffraction Imaging

Strain is known to enhance the activity of the oxygen reduction reaction in catalytic platinum alloy nanoparticles, whose inactivity is the primary impediment to efficient fuel cells and metal–air batteries. Here, Bragg coherent diffraction imaging (BCDI) was employed to reveal the strain evolution during the voltammetric cycling in Pt–Ni alloy nanoparticles composed of Pt 2 Ni 3 , Pt 1 Ni 1 , and Pt 3 Ni 2 . Analysis of the 3D strain images using a core–shell model shows that the strain as large as 5% is induced on Pt-rich shells due to Ni dissolution. The composition dependency of the strain on the shells is in excellent agreement with that of the catalytic activity. The present study demonstrates that BCDI enables quantitative determination of the strain on alloy nanoparticles during electrochemical reactions, which provides a means to exploit surface strain to design a wide range of electrocatalysts.

36 MATERIALS SCIENCE↗

Probing atom dynamics of excited Co-Mo-S nanocrystals in 3D

Advances in electron microscopy have enabled visualizations of the three-dimensional (3D) atom arrangements in nano-scale objects. The observations are, however, prone to electron-beam-induced object alterations, so tracking of single atoms in space and time becomes key to unravel inherent structures and properties. Here, we introduce an analytical approach to quantitatively account for atom dynamics in 3D atomic-resolution imaging. The approach is showcased for a Co-Mo-S nanocrystal by analysis of time-resolved in-line holograms achieving ~1.5 Å resolution in 3D. The analysis reveals a decay of phase image contrast towards the nanocrystal edges and meta-stable edge motifs with crystallographic dependence. These findings are explained by beam-stimulated vibrations that exceed Debye-Waller factors and cause chemical transformations at catalytically relevant edges. This ability to simultaneously probe atom vibrations and displacements enables a recovery of the pristine Co-Mo-S structure and establishes, in turn, a foundation to understand heterogeneous chemical functionality of nanostructures, surfaces and molecules.

36 MATERIALS SCIENCE↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Stereo-DIC Challenge 1.0 – Rigid Body Motion of a Complex Shape

Background Stereo-DIC is a widely used optical measurement technique that provides a dense full-field 3D measurement of the shape, displacement, and strain of a solid sample. When compared with 2D-DIC, Stereo-DIC provides greater flexibility and expands its use beyond flat, planar specimens. Furthermore, the widespread availability of commercial systems has led to the adoption of the technique throughout industry, academia, and government research labs. Objective Even though some research has been done to understand the effects of different experimental and stereo-DIC parameters, no reference is available to benchmark and compare the performance of current stereo-DIC algorithms to each other. Methods This paper provides the description and analysis of a carefully controlled 3D experiment and associated images used to compare the results from five subset based DIC software packages. Both the images and analysis codes used in this paper to compare the results are described here and are available for download and use for continued research. Results We show that over a very large range of motion, the 3D errors are very small, less than 80μm over a travel of ±20 mm out-of-plane and ±20 mm in-plane. While all codes performed similarly, there are important differences noted in the paper. Conclusion The image sets and results comparison software are hosted by the International DIC Society (www.iDICs.org) and are freely available for download and analysis for comparison with results in this paper. Furthermore, it is hoped that this set of images can be used for future research in improving stereo-DIC by future authors.

Algorithms comparison↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗