Search NASA⌕ Search

SEARCH · Search NASA

Results for “AC-LGAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 $n_{eq}/cm^2$ fluence over the lifetime of the experiment.

AC-LGAD strips↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a second generation of the Fermilab Constant Fraction Discriminator ASIC for time-stamping long-strip AC-LGAD sensors.

We present the design and performance characterization results of the second generation of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout AC-coupled low gain avalanche detector (AC-LGAD) sensors. This study presents the performance of the ASIC which was optimized specifically for reading out strip AC-LGAD sensors designed for ePIC experiment at EiC. Performance was measured using charge injection and particle beams with prototype AC-LGAD sensors wirebonded to the FCFD ASIC.

Apresyan, A.↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimization to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

AC-LGADs Fermilab front-end electronics characterization

Here, we characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the time resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than 2 p s at the 1 σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AC-LGADs for 4D Tracking

Explore the source record for details and available documents.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗