Search NASA⌕ Search

SEARCH · Search NASA

Results for “AC-LGAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 $n_{eq}/cm^2$ fluence over the lifetime of the experiment.

AC-LGAD strips↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a second generation of the Fermilab Constant Fraction Discriminator ASIC for time-stamping long-strip AC-LGAD sensors.

We present the design and performance characterization results of the second generation of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout AC-coupled low gain avalanche detector (AC-LGAD) sensors. This study presents the performance of the ASIC which was optimized specifically for reading out strip AC-LGAD sensors designed for ePIC experiment at EiC. Performance was measured using charge injection and particle beams with prototype AC-LGAD sensors wirebonded to the FCFD ASIC.

Apresyan, A.↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We will present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility, and a study of the performance of AC-LGAD sensors as a function of their thickness. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. Long strip sensors with sparse readout offer better cost and performance for applications where channel count or electrical power density is a constraint. Thanks to the excellent signal to noise ratio in AC-LGADs, sparse readout can be exploited without significant degradation of spatial or time resolution, which is demonstrated in our studies. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. We will present our studies of the sensor geometry optimization to maintain the desirable sensor performance characteristics with increasingly larger electrodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

AC-LGADs Fermilab front-end electronics characterization

Here, we characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the time resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than 2 p s at the 1 σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AC-LGADs for 4D Tracking

Explore the source record for details and available documents.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗