Ampoule failure sensor time response testing: Experiment 1

The response time of an ampoule failure sensor exposed to a liquid or vapor gallium-arsenide (GaAs) is investigated. The experimental configuration represents the sample/ampoule cartridge assembly used in NASA's Crystal Growth Furnace (CGF). The sensor is a chemical fuse made from a metal with which the semiconductor material reacts more rapidly than it does with the containing cartridge. For the III-IV compound of GaAs, a platinum metal was chosen based on the reaction of platinum and arsenic at elevated temperatures which forms a low melting eutectic. Ampoule failure is indicated by a step change in resistance of the failure sensor on the order of megohms. The sensors will increase the safety of crystal growth experiments by providing an indication that an ampoule has failed. Experimental results indicate that the response times (after a known ampoule failure) for the 0.003 and 0.010 inch ampoule failure sensors are 2.4 and 3.6 minutes, respectively. This ampoule failure sensor will be utilized in the CGF during the second United States Microgravity Laboratory Mission (USML-2) and is the subject of a NASA patent application.

Johnson, M. L.↗

Ampoule failure sensor time response testing: Experiments 2 and 3

The response time of an ampoule failure sensor exposed to a liquid or vapor gallium-arsenide (GaAs) and the corresponding breach time of the containing cartridge is investigated. The experiments were conducted in niobium-hafnium (WC-103) cartridges with an exterior silicide coating. These cartridges were built to flight specifications that were used in NASA's Crystal Growth Furnace during the first United States Microgravity Laboratory (USML-1) mission. The ampoule failure sensor is a chemical fuse made from a metal with which the semiconductor material reacts more rapidly than it does with the containing cartridge. In these experiments a platinum metal was used for the manufacture of the sensors. This technical report discusses the response time of two different sensor designs. The first design utilizes a helical wrapped wire and the second uses a single bare wire element. Experimental results indicate that both sensors are adequate in sensing the presence of molten or vapor GaAs with the latter having a 2-minute longer response time. In both experiments, the containing cartridge was breached within 185 minutes after ampoule rupture.

Johnson, M. L.↗

Ampoule failure sensor development for semiconductor crystal growth experiments

Currently there are no devices to detect an ampoule failure in semiconductor crystal growth experiments. If an ampoule fails, it will go undetected until the containing cartridge is breached due to chemical degradation. The experiment will then be terminated resulting in a failed experiment and a loss of data. The objective of this research was to develop a reliable failure sensor that would detect a specific liquid or vapor material before the metallic cartridge is degraded and the processing furnace contaminated. The sensor is a chemical fuse made from a metal with which the semiconductor material reacts more rapidly than it does with the containing cartridge. Upon ampoule failure, the sensor is exposed to the vapor or liquid semiconductor and the chemical reaction causes a resistance change in the sensor material. The sensor shows a step change in resistance on the order of megohms when exposed to mercury zinc telluride (HgZnTe), mercury cadmium telluride (HgCdTe), or gallium arsenide (GaAs). This ampoule failure sensor is being tested for possible use on the second United States Microgravity Mission (USML-2) and is the subject of a NASA patent application.

CHEMICAL FUSE↗

Ampoule Failure System

An ampoule failure system for use in material processing furnaces comprising a containment cartridge and an ampoule failure sensor. The containment cartridge contains an ampoule of toxic material therein and is positioned within a furnace for processing. An ampoule failure probe is positioned in the containment cartridge adjacent the ampoule for detecting a potential harmful release of toxic material therefrom during processing. The failure probe is spaced a predetermined distance from the ampoule and is chemically chosen so as to undergo a timely chemical reaction with the toxic material upon the harmful release thereof. The ampoule failure system further comprises a data acquisition system which is positioned externally of the furnace and is electrically connected to the ampoule failure probe so as to form a communicating electrical circuit. The data acquisition system includes an automatic shutdown device for shutting down the furnace upon the harmful release of toxic material. It also includes a resistance measuring device for measuring the resistance of the failure probe during processing. The chemical reaction causes a step increase in resistance of the failure probe whereupon the automatic shutdown device will responsively shut down the furnace.

Watring, Dale A.↗