AGC-2 Graphite Preirradiation Data Analysis Report

This report describes the specimen loading order and documents all preirradiation examination material property measurement data for graphite specimens contained within the Second Advanced Graphite Capsule (AGC 2) irradiation capsule. The AGC 2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens in order to garner quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear grade graphites. This testing will ascertain the in service behavior of the graphite for pebble bed and prismatic very high temperature reactor designs. Similar to the First Advanced Graphite Capsule (AGC 1) preirradiation examination report, material property tests were conducted on specimens from 18 nuclear grade graphite types. However, AGC 2 tested an increased number of specimens (i.e., 512) prior to loading them into the AGC 2 irradiation assembly. All AGC 2 specimen testing was conducted at Idaho National Laboratory from July 2009 to August 2010. This report also details the specimen loading methodology for graphite specimens inside the AGC 2 irradiation capsule. The AGC 2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid plane. This provides similar specimens with and without an applied load. Analysis in this document utilizes the neutron flux profile calculated for the AGC 2 capsule design, the capsule dimensions, and the size (i.e., length) of the selected graphite specimens to create a stacking order that produces “matched pairs” of graphite specimens above and below the AGC 2 capsule elevation mid point, thus providing specimens with similar neutron dose levels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Nuclear Data Management and Analysis System Plan

The United States Department of Energy Advanced Reactor Technologies Program was formed in Fiscal Year 2015 and encompasses the Next Generation Nuclear Plant Project and Very High Temperature Reactor (VHTR) Program as they were known previously. The VHTR Program was created to support design and licensing of the first VHTR nuclear plant. Data created for and used by the program must be qualified for use, stored in a readily accessible electronic form, categorized to assure the correct data are used, and controlled to prevent data corruption or inadvertent changes. The Nuclear Data Management and Analysis System was designed to support the data needs of the VHTR Program, at the time and now the Advanced Reactor Technologies Program. Since its inception, use of the Nuclear Data Management and Analysis System has expanded to support additional projects and programs with similar requirements for control, analysis, and availability of large data sets.

99 GENERAL AND MISCELLANEOUS

HDG-1 Graphite Preirradiation Data Package Report

This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS