Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anion exchange membrane fuel cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spatially resolved performance and degradation in a perfluorinated anion exchange membrane fuel cell

Anion exchange membrane fuel cells may enable future operation with non-precious metal-based catalysts. These systems have a delicate sensitivity to operating conditions such as humidification levels and the presence of CO2 in the air oxidant stream. We present spatially resolved in-situ performance results that shed light on phenomena that are unique to anion exchange membrane fuel cells. For cell construction, a highly conductive perfluorinated anion exchange polymer was used as the membrane and the material in powder form as the ionomer. Experiments were conducted to investigate the effects of humidification, fuel/oxidant concentration, and carbonation effects on the performance and its distribution in the cell. The results indicated that (i) dry conditions at the cathode have a stronger effect than at the anode on overall cell performance, (ii) performance significantly suffered when humidification was below 90%, (iii) fuel and oxidant dilution effects lead mass-transport losses and were stronger than flow rate effects, (iv) CO2 in the cathode feed stream creates an equilibration disparity between the inlet and outlet sections and CO2 purging is affected by flooding conditions, and (v) after >500 h of operation, performance deteriorates predominantly at the inlet.

2+1D fuel cell model↗

Understanding Recoverable vs Unrecoverable Voltage Losses and Long-Term Degradation Mechanisms in Anion Exchange Membrane Fuel Cells

Anion exchange membrane fuel cells (AEMFCs) have recently shown excellent progress in terms of their performance – e.g., achievable power and current density. However, very few AEMFCs have been demonstrated with the ability to operate for a long duration (>1000 h). In addition, it is unknown whether performance losses observed during operation are reversible, irreversible, or a combination of the two. In this study, a high-performance AEMFC operated continuously at 600 mA/cm 2 for 3600 h (150 days) at 80 °C with H 2 /O 2 reacting gases was demonstrated. Throughout testing, the electrochemical properties of the AEMFC were probed to provide information about performance degradation pathways and their degree of reversibility. It was found that a portion of the performance loss that occurs during AEMFC operation was due to suboptimal reaction conditions and can be recovered. At the end of the experiment, the cell was disassembled, and its structure and composition were evaluated at the nanoscale by aberration-corrected scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy. The structure and composition of the electrode were compared to cells at the beginning of their operational life. It was found that the primary mechanism for long-term AEMFC performance loss was catalyst agglomeration. During the operational time, there was no evidence of significant polymer degradation, likely due to the high hydration state of the cell. By documenting the long-term changes in high-performing AEMFCs, this work provides important information for the systematic design of cell components and demonstrates the importance of controlling cell operation, which can aid in the commercialization and widespread deployment of low-cost, long-life AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Editors’ Choice—Examining Performance and Durability of Anion Exchange Membrane Fuel Cells with Novel Spirocyclic Anion Exchange Membranes

A series of spirocyclic copolymer membranes with varying ion exchange capacities (IECs) were investigated to probe the impact of polymer properties on in situ fuel cell performance and stability. In-situ electrochemical tests and post-mortem electron microscopy analysis of cross-sectioned membrane electrode assemblies (MEAs) have been combined with voltage loss breakdown analysis to evaluate the performance and degradation of different MEAs, and to probe the catalyst morphology and electrode structure at different stages of operation. Voltage loss breakdown results show that membrane degradation and kinetic losses played only a minor role in observed performance degradation and that performance losses were primarily related to increasing mass transport losses. From microscopy studies, carbon corrosion and Pt nanoparticle growth were identified at both the cathode and anode although more pronounced on the cathode resulting in significant structural changes. The membrane with the lowest IEC (1.3 mmolg −1 ) demonstrated the lowest peak power density ~ 1.16 W cm −2 , however, it showed the most stable performance (constant 0.6 A cm −2 hold) with ~ 5% degradation over 540 h. Isolation of performance losses and microscopic analysis of electrodes for anion exchange membrane fuel cells has not been reported previously, and these results help identify critical performance degradation concerns.

25 ENERGY STORAGE↗

High-performing commercial Fe–N–C cathode electrocatalyst for anion-exchange membrane fuel cells

Here, to reduce the cost of fuel cell stacks and systems, it is important to create commercial catalysts that are free of platinum group metals (PGMs). To do this, such catalysts must have very high activity, but also have the correct microstructure to facilitate the transport of reactants and products. Here, we show a high-performing commercial oxygen reduction catalyst that was specifically developed for operation in alkaline media and is demonstrated in the cathode of operating anion-exchange membrane fuel cells (AEMFCs). With H 2 /O 2 reacting gases, AEMFCs made with Fe–N–C cathodes achieved a peak power density exceeding 2 W cm –2 (>1 W cm –2 with H 2 /air) and operated with very good voltage durability for more than 150 h. These AEMFCs also realized an iR-corrected current density at 0.9 V of 100 mA cm –2 . Finally, in a second configuration, Fe–N–C cathodes paired with low-loading PtRu/C anodes (0.125 mg PtRu per cm 2 , 0.08 mg Pt per cm 2 ) demonstrated a specific power of 10.4 W per mg PGM (16.25 W per mg Pt).

25 ENERGY STORAGE↗

Achieving High‐Performance and 2000 h Stability in Anion Exchange Membrane Fuel Cells by Manipulating Ionomer Properties and Electrode Optimization

The primary function of the ionomers that are incorporated into fuel cell electrode catalyst layers is to provide pathways for ion transport between the catalyst active sites and the electrolyte. This is influenced by many variables, including the ion-exchange capacity, water uptake, and molecular weight. In anion exchange membrane fuel cells (AEMFCs), controlling ionomer water uptake is particularly important and tailoring this property in each electrode is an important consideration when looking to maximize cell performance. In this study, three poly(norbornene) tetrablock copolymer ionomers with a range of physical properties are synthesized and incorporated into AEMFC anode and cathode electrodes. Systematic electrode engineering with these ionomers allows the peak power density to be increased by 100% (1.6 W cm -2 → 3.2 W cm -2 ) and the current density at 0.2 V to be increased by 59% (5.9 A cm -2 → 9.4 A cm -2 ). Moreover, the top-performing electrode configuration is tested in an operating AEMFC at the US Department of Energy defined current density of 600 mA cm -2 for 2000 h, showing a record-low voltage decay rate of 15.36 µV h -1 – only 3.65% –a over 2000 h. Here, this work sets a new bar for AEMFCs, reporting the best combination of performance and durability of any AEMFC to date.

08 HYDROGEN↗

Effect of reacting gas flowrates and hydration on the carbonation of anion exchange membrane fuel cells in the presence of CO 2

Anion exchange membrane fuel cells (AEMFCs) have been widely touted as a low-cost alternative to existing proton exchange membrane fuel cells. However, one of the limitations of this technology has been the severe performance penalty related to the introduction of CO 2 to the cell – typically in the air cathode feed. Introduction of CO 2 into AEMFCs results in cell carbonation, which imparts thermodynamic, kinetic and Ohmic overpotentials that can add up to hundreds of millivolts. Therefore, it is important to find strategies and operational protocols for AEMFCs that minimize these overpotentials. In this paper, we reserach the impacts of the anode and cathode flowrate, as well as the cell hydration level, on the extent of cell carbonation and cell polarization. Key findings include: (1) decreasing the cathode flowrate generally decreases the total CO 2 -related voltage loss while changing the anode flowrate has a minimal effect; (2) increasing cell hydration helps to mitigate the performance loss in the presence of CO 2 ; and (3) operational combinations are found that significantly reduce the CO 2 penalty compared to the present literature.

25 ENERGY STORAGE↗

Elucidating the degradation mechanisms of Pt-free anode anion-exchange membrane fuel cells after durability testing

The development of anion-exchange membrane fuel cells (AEMFCs) has recently accelerated due to synergistic improvements yielding highly conductive membranes, stable ionomers, and enhanced alkaline electrocatalysts. However, cell durability, especially under realistic conditions, still poses a major challenge. Herein, we employ low-loadings of Pt-free Pd-based catalysts in the anode of AEMFCs and elucidate potential degradation mechanisms impacting long-term performance under conditions analogous to the real-world (high current density, H 2 –air (albeit CO 2 -free), and intermittent operation). Our high-performing AEMFCs achieve impressive performance with power densities approaching 1 W cm —2 and current densities up to 3.5 A cm —2 . Over a 200 h period of continuous operation in H 2 –air at a current density of 600 mA cm —2 , our model Pd/C–CeO 2 anode cell exhibits record stability (~30 μV h —1 degradation) compared to the literature and up to 6× better stability than our Pd/C and commercial Pt/C anode cells. Following an 8 h shutdown, the Pd/C–CeO 2 anode cell was restarted and continued for an additional 300 h with a higher degradation rate of ~600 μV h —1 . Thorough in situ evaluations and post-stability analyses provide insights into potential degradation mechanisms to be expected during extended operation under more realistic conditions and provide mitigation strategies to enable the widespread development of highly durable AEMFCs.

08 HYDROGEN↗

Migration and Precipitation of Platinum in Anion‐Exchange Membrane Fuel Cells

Abstract Despite the recent progress in increasing the power generation of Anion‐exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X‐ray micro‐computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X‐ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt +2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo−N−C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

Raut, Aniket↗

Migration and Precipitation of Platinum in Anion–Exchange Membrane Fuel Cells

Despite the recent progress in increasing the power generation of Anion-exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X-ray micro-computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt+2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Furthermore, diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo–N–C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Anion Exchange Membrane Fuel Cell Cathodes by Varying Electrocatalysts and Electrode Processing

To date, several high-performing anion exchange membrane fuel cells (AEMFCs) have been demonstrated, but most these studies have focused on Pt containing cathodes with high loadings. Here, we explore and compare the performance and perform electrochemical diagnostics on three leading AEMFC cathode electrocatalysts: Pt/C, Ag/C, and Fe–N–C with electrodes that have been processed with either powder or dispersion-based ionomers using perfluorinated anion exchange polymers. Pt/C had the highest performance but also showed a strong dependence on ionomer type, with powder ionomer exhibiting much higher performance. These results were consistent with the observations for Ag/C but did not hold for the Fe–N–C catalyst where almost no change was observed between powder and dispersion-based ionomers. This is the first-time the impact of powder and dispersion ionomer with different classes of cathode electrocatalysts on the fuel cell performance have been compared, and the results have strong implications for the ability to achieve high performance at low loadings and for better understanding catalyst-ionomer interactions within AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Tailoring catalyst layer structures for anion exchange membrane fuel cells by controlling the size of ionomer aggreates in dispersion

The development of anion exchange membranes and ionomers plays a critical role in performance of anion exchange membrane fuel cells. However, the optimal design of catalyst layer structures still remains unexplored despite its significance. Herein, the rational design guide is presented for cathode and anode catalyst layers using m-TPN1 ionomer by controlling the size of ionomer aggregates in dispersion and comparing various catalyst layer structures. The size of m-TPN1 aggregates decreases, creating a more uniform ionomer distribution and a larger triple-phase-boundary. As ionomer distribution of the cathode catalyst layer becomes more uniform, the power density of membrane-electrode-assembly is enhanced. Also, the power density at fully humidified condition strongly correlates with the porosity of anode catalyst layer due to the limitation of hydrogen transport at anode by water flooding.

42 ENGINEERING↗

Analytical-based simulation approach for an anion exchange membrane fuel cell

An analytical and empirical-based 1-D, non-isothermal, steady-state model for anion exchange membrane fuel cell capable of capturing two-phase phenomena is presented in this study. Coupled multi-physics including mass and charge transport, electrochemical reactions, heat transfer, and two-phase water transport are considered in the model and the simulated results are compared to experimental data. To better represent actual material properties and localized conditions, the model applies multilayer discretization in the gas diffusion electrode to enhance prediction accuracy. The model successfully predicts the baseline performance at 70 °C, 131 kPa abs., 92% RH with pure H 2 /O 2 gas as well as the limiting current at 10% H 2 . The robust simulation approach allows for simplistic and accurate estimation of cell performance without the complications of applying two-phase parameters and expensive computational need for numerical models. In addition, the results from the sensitivity studies of material properties and operating conditions provide valuable insights on water management strategies and optimal component design for advancing anion exchange membrane fuel cell technology.

1-D model↗

Water limiting current measurements in anion exchange membrane fuel cells (AEMFCs); part 1: Water limiting current method development

We report water management is critical in optimizing anion exchange membrane fuel cell (AEMFCs) performance and durability. The role of membranes on determining cell water balance in AEMFCs has received limited study. A more thorough understanding of membrane water transport parameters is necessary for thorough cell optimization. In this study, a novel method for probing limiting current based on water flux across an AEMFC is presented for the first time. The water limiting current has been investigated as a function of relative humidity of anode and cathode streams, cathode backpressure and cell operating temperature. From these studies, it is clearly shown that water diffusion through the membrane from the anode is the most critical mechanism for achieving high current density performance and durability. The developed method can act as a novel screening technique that focuses on the impacts of water transport parameters and helps identify promising membrane materials based on their water transport properties. A critical but underappreciated facet of AEMFC performance and durability.

30 DIRECT ENERGY CONVERSION↗

Hydrogenated TiO 2 Carbon Support for PtRu Anode Catalyst in High‐Performance Anion‐Exchange Membrane Fuel Cells

Abstract The availability of durable, high‐performance electrocatalysts for the hydrogen oxidation reaction (HOR) is currently a constraint for anion‐exchange membrane fuel cells (AEMFCs). Herein, a rapid microwave‐assisted synthesis method is used to develop a core–shell catalyst support based on a hydrogenated TiO 2 /carbon for PtRu nanoparticles (NPs). The hydrogenated TiO 2 provides a strong metal‐support interaction with the PtRu NPs, which improves the catalyst's oxophilicity and HOR activity compared to commercial PtRu/C and enables greater size control of the catalyst NPs. The as‐synthesized PtRu/TiO 2 /C‐400 electrocatalyst exhibits respectable performance in an AEMFC operated at 80 °C, yielding the highest current density (up to 3× higher) within the catalytic region (compared at 0.80–0.90 V) and voltage efficiency (68%@ 0.5 A cm −2 ) values in the compared literature. In addition, the cell demonstrates promising short‐term voltage stability with a minor voltage decay of 1.5 mV h −1 . This “first‐of‐its‐kind in alkaline” work may open further research avenues to develop rapid synthesis methods to prepare advanced core–shell metal‐oxide/carbon supports for electrocatalysts for use in the next‐generation of AEMFCs with potential applicability to the broader electrochemical systems research community.

08 HYDROGEN↗

Stable, high-performing bifunctional electrodes for anion exchange membrane-based unitized regenerative fuel cells

Anion exchange membrane unitized regenerative fuel cells (AEM-URFCs) are a promising technology for energy storage and electricity production; however, their efficiency is limited by the kinetics of the bifunctional oxygen electrode (BOE) where the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) occur. A particular concern when designing the BOE is that the OER and ORR have differing catalytic requirements, which make it challenging to develop effective bifunctional electrocatalysts with single active sites. In this study, we focus on advancing the BOE performance using Pt-IrO x and Pt-NiCoO x electrocatalysts. Here, single-layer and dual-layer Pt-IrO x BOEs were made, with the dual-layer electrode leading to improved performance due to efficient catalyst utilization in both modes. Using the dual-layer oxygen electrode paired with a PtRu/C hydrogen electrode, a round trip efficiency (RTE) as high as 50% (62 %iR-free) was achieved at 500 mA/cm 2 and operation for more than 24 h, which included five one-hour-long H 2 generation and consumption cycles followed by one eight-hour-long cycle. To the best of our knowledge, this is the highest performance for AEM-URFCs reported to date. Lastly, the approach is extended to electrodes with a Pt loading of 0.5 mg/cm 2 and the IrO x substituted by NiCoO x .

25 ENERGY STORAGE↗

Operando X-ray absorption spectroscopic investigation of electrocatalysts state in anion exchange membrane fuel cells

Capturing the active state of (electro)catalysts under operating conditions, namely operando, is the ultimate objective of (electro)catalyst characterization, enabling the unraveling of reaction mechanisms and advancing (electro)catalyst development. Operando insights advance our understanding of the correlations between electrochemical tests and device-level performances. However, operando characterization of electrocatalysts is challenging due to the complexity of electrochemical devices and instrumental limitations. As a result, the majority of electrocatalyst characterizations have been limited to half-cell in situ studies. Here, we present an operando X-ray absorption spectroscopic study of Mn spinel oxide electrocatalysts in an operating fuel cell employing a custom-designed cell. Our results reveal that in anion exchange membrane fuel cells, the Mn valence state, within spinel Mn 3 O 4 /C, increases to above 3+, adopting an octahedral coordination devoid of Jahn-Teller distortions. This structural change results in an AEMFC performance equivalent to that of Co 1.5 Mn 1.5 O 4 /C, a composition that outperforms Mn 3 O 4 /C in rotating disk electrode tests. Our results underscore the importance of operando characterizations in elucidating the active state of electrocatalysts and understanding the correlation(s) between electrochemical tests and device performance.

Electrocatalysis↗