Search NASA⌕ Search

SEARCH · Search NASA

Results for “Attack localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Temperature Oxidation Behavior of FeCoCrNi+(Cu/Al)-Based High-Entropy Alloys in Humid Air

Previous studies showed some transition metal high-entropy alloy (HEA) compositions can have good oxidation resistance in air up to 800 °C. Four equiatomic HEAs have been developed based on FeCoCrNi with additions of Mn, Cu, Al or Al+Cu. The oxidation behavior of these HEAs was compared in humid (10 vol.% H2O) air at 800 °C for 100–500 h to investigate the influence of water vapor on the oxidation mechanisms. The Cu- and Al-containing alloys exhibited improved oxidation resistance over the Mn composition. For the Cu-containing alloy, a local attack of the Cu-rich phase was observed, which formed an Fe/Ni/Co/Cr spinel that was surrounded by Cr2O3. This oxide was thicker for the humid air atmosphere when compared to dry air, and the transition of the Cu oxide to the spinel was accelerated. The Al-containing HEA formed a thin Al2O3 scale with humidity suppressing AlN formation and forming a smoother oxide layer. The Al+Cu composition had the highest overall oxidation resistance (minimal local attack, no nitridation) and also showed a smooth oxide scale topography under humid air oxidation as opposed to a plate-like, rougher scale under dry air.

Crystallography↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Resilient Signal Reconstruction under Adversarial Attacks

We consider the problem of signal reconstruction for a system under sparse signal corruption by a malicious agent. The reconstruction problem follows the standard error coding problem that has been studied extensively in the literature. We include a new challenge of robust estimation of the attack support. The problem is then cast as a constrained optimization problem merging promising techniques in the area of deep learning and estimation theory. A pruning algorithm is developed to reduce the "false positive" uncertainty of data-driven attack localization results, thereby improving the probability of correct signal reconstruction. Sufficient conditions for the correct reconstruction and the associated reconstruction error bounds are obtained for both exact and inexact attack support estimation. Moreover, a simulation of a water distribution system is presented to validate the proposed techniques.

Robust, Signal reconstruction, Resilient estimator↗

Effect of Oxidizing Impurities on the Corrosion Behavior of Structural Alloys Exposed to MgCl 2 Molten Salt Vapor

The corrosion behavior of structural alloys SS304 and IN617 when exposed to vapors of MgCl 2 molten salt at 764 °C for 100 h in an argon atmosphere was investigated as a function of the level of oxidizing impurities (e.g., NaOH) present in the salt. Increasing the concentration of oxidizing impurities in the salt caused an increase in corrosion in both structural alloys, as measured by Cr depletion layers. A poorly adhered oxide scale layer containing Mg, Al, and Cr was observed on the surface of the metals, and local attack was observed as well. The Ni-based IN617 showed lower Cr depletion and less scale formation than the Fe-based SS304. These results demonstrate that oxidizing impurities in the molten salt will impact the vapor phase corrosion for structural members exposed to the molten salt headspace. This finding is highly relevant for understanding the effects of the vapor phase in molten salt applications, including molten salt thermal energy storage, molten salt nuclear reactors, and molten salt electrochemistry.

25 ENERGY STORAGE↗

Effect of thermal treatments on electrochemical behavior of binder jetted 17-4 PH stainless steel

Binder jetted 17–4 PH stainless steel was post-processed to relate heat treatment, microstructure, and corrosion in 3.5 wt% NaCl. Specimens were sintered at 1380 or 1400 °C, solution-annealed at 1055 °C for 1 h, and aged at 482 °C for 1 h. Here, as-sintered parts showed α′-martensitic matrix with a δ-ferrite network and Cu-rich precipitates in ferrite; inclusions (MnS, NbC) promoted localized attack. solutionizing redistributed elements and reduced ferrite, while aging generated coherent Cu nano-precipitates. Corrosion resistance was highly sensitive to post-processing in which aged specimens exhibited the lowest corrosion current density and formed a thicker, stable Cr 2 O 3 -rich passive film, whereas sintered specimens degraded most. Pitting potential depended on sintering temperature and microstructure, with 1400 °C sintering yielding more positive pitting potentials and the best overall performance after aging. Although the 1400-solutionized condition showed a relatively noble pitting response versus 1380-solutionized, it displayed unstable corrosion kinetics attributed to an imperfect passive film linked to higher NbC density. XPS depth profiles corroborated these trends, showing thicker, more continuous Cr 2 O 3 in aged states and discontinuous/thinning oxides in less resistant conditions. Practically, high-temperature sintering (∼1400 °C) followed by solutionizing and aging is recommended, with further gains expected from reducing NbC/MnS populations and porosity via powder and process control.

36 MATERIALS SCIENCE↗

Corrosion of Zinc Cold Spray Coatings in a Wet Sweet and Sour Gas Environment

Internal corrosion is a problem for steel pipelines transporting natural gas or CO 2 containing water and partial pressures of H 2 S higher than 0.3 kPa (0.05 psi). This work aims to mitigate internal corrosion in steel pipelines transporting natural gas containing H 2 S using cold spray coatings. Two types of the cold spray binary metallic coatings (zinc chromium [ZnCr]. zinc niobium [ZnNb]) were studied using electrochemical techniques: potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy. The corrosion resistance of cold spray coatings (ZnCr, ZnNb) was evaluated in an environment containing 4 bar CO 2 pressure, simulating the partial pressures found in gas transmission lines over a solution of 3.5 wt% NaCl heated to 40°C. A concentration of 0.003 M Na 2 S 2 O 3 ·5H 2 O, corresponding to H 2 S partial pressures around 0.079 bar (1.146 psi), was used to simulate sour conditions. Postcorrosion surface characterization was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive x-ray spectroscope (EDS) and x-ray diffraction analysis. The data showed that the presence of 0.003 M Na 2 S 2 O 3 ·5H 2 O shifted the corrosion potential to more anodic values and decreased the corrosion current density. Both coatings showed similar behavior after 1 h of exposure in the CO 2 /H 2 S environment, indicating that similar electrochemical reactions were occurring on ZnNb and ZnCr. SEM images and EDS surface analyses for specimens showed a significant change in the surface chemical composition of carbon steel coated with ZnNb and ZnCr after 24 h of immersion. In the presence of thiosulfate (under sour conditions), the formation of corrosion product layers (ZnCO 3 and ZnS) on top of ZnNb and ZnCr coatings increased their corrosion resistance, which helped to reduce their corrosion by a factor of 2. Under a sweet environment, the corrosion rates for steel coated with cold spray coatings after 14 d of exposure are lower than that for galvanized steel by a factor of 5 due to the ZnCO 3 layer formed on top of the coatings. The ZnCO 3 layer formed on the steel surface acts as a physical barrier against corrosion by blocking the diffusion of corrosive species to the surface. No localized attack was observed. ZnCr Cold spray coating with defect showed promising corrosion protection against CO 2 corrosion (sweet corrosion) after 14 d of exposure to a CO 2 environment. Here, the scratch on the coating simulated damage created in service, and it was deep enough to expose the substrate material (steel). The formation of zinc oxide (ZnO) and zinc carbonate (ZnCO 3 ) on the scratch confirmed the cathodic protection of the steel by ZnCr and ZnNb coatings.

36 MATERIALS SCIENCE↗

Laser shocking of 2024 and 7075 aluminum alloys

The effect of laser generated stress waves on the microstructure, hardness, strength and stress corrosion resistance of 2024 and 7075 aluminum alloys was investigated. Pulsed CO2 and neodymium-glass lasers were used to determine the effect of wavelength and pulse duration on pressure generation and material property changes. No changes in material properties were observed with CO2 laser. The strength and hardness of 2024-T351 and the strength of 7075-T73 aluminum alloys were substantially improved by the stress wave environments generated with the neodymium-glass laser. The mechanical properties of 2024-T851 and 7075-T651 were unchanged by the laser treatment. The correlation of the laser shock data with published results of flyer plate experiments demonstrated that a threshold pressure needed to be exceeded before strengthening and hardening could occur. Peak pressures generated by the pulsed laser source were less than 7.0 GPa which was below the threshold pressure required to change the mechanical properties of 2024-T851 and 7075-T651. Corrosion studies indicated that laser shocking increased the resistance to local attack in 2024-T351 and 7075-T651.

Clauer, A. H.↗

A low speed two-dimensional study of flow separation on the GA(W)-1 airfoil with 30-percent chord Fowler flap

Measurements of flow fields with low speed turbulent boundary layers were made for the GA(W)-1 airfoil with a 0.30 c Fowler flap deflected 40 deg at angles of attack of 2.7 deg, 7.7 deg, and 12.8 deg, at a Reynolds number of 2.2 million, and a Mach number of 0.13. Details of velocity and pressure fields associated with the airfoil flap combination are presented for cases of narrow, optimum and wide slot gaps. Extensive flow field turbulence surveys were also conducted employing hot-film anemometry. For the optimum gap setting, the boundaries of the regions of flow reversal within the wake were determined by this technique for two angles of attack. Local skin friction distributions for the basic airfoil and the airfoil with flap (optimum gap) were obtained using the razor blade technique.

Seetharam, H. C.↗

Processing of fused silicide coatings for carbon-based materials

The processing and oxidation resistance of fused Al-Si and Ni-Si slurry coatings on ATJ graphite was studied. Ni-Si coatings in the 70 to 90 percent Si range were successfully processed to melt, wet, and bond to the graphite. The molten coatings also infiltrated the porosity in graphite and reacted with it to form SiC in the coating. Cyclic oxidation at 1200 C showed that these coatings were not totally protective because of local attack of the substrate, due to the extreme thinness of the coatings in combination with coating cracks.

Smialek, J. L.↗

Processing of fused silicide coatings for carbon-based materials

The processing and oxidation resistance of fused Al-Si and Ni-Si slurry coatings on ATJ graphite was studied. Ni-Si coatings in the 70 to 90 percent Si range were successfully processed to melt, wet, and bond to the graphite. The molten coatings also infiltrated the porosity in graphite and reacted with it to form SiC in the coating. Cyclic oxidation at 1200 C showed that these coatings were not totally protective because of local attack of the substrate, due to the extreme thinness of the coatings in combination with coating cracks. Previously announced in STAR as N83-27019

Smialek, J. L.↗

A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Attack detection and localization with adaptive thresholding

According to some embodiments, a system, method, and non-transitory computer readable medium are provided comprising a plurality of real-time monitoring nodes to receive streams of monitoring node signal values over time that represent a current operation of the cyber physical system; and a threat detection computer platform, coupled to the plurality of real-time monitoring nodes, to: receive the monitoring node signal values; compute an anomaly score; compare the anomaly score with an adaptive threshold; and detect that one of a particular monitoring node and a system is outside a decision boundary based on the comparison, and classify that particular monitoring node or system as anomalous. Numerous other aspects are provided.

Abbaszadeh, Masoud↗

Theoretical and experimental flow fields for a supersonic cruise fighter forebody

The capability of two numerical methods to predict the flow field about a representative supersonic cruise aircraft was examined. The two codes were a small-disturbance transonic program of Boppe and a conservative form full-potential transonic program of Shankar and Szema. For the former code, comparisons were made with wind-tunnel data at Mach numbers of 0.6, 0.9, and 1.2 and angles of attack of 0 deg, 5 deg, and 10 deg (7.5 deg instead of 10 deg at a Mach number of 1.2). Predictions from the two codes were compared at a Mach number of 1.2 and an angle of attack of 7.5 deg. The comparison criteria were contours of local angle of attack, local angle of sideslip, and local Mach number. The comparisons indicated that both codes may be considered useful for design applications, depending on the degree of accuracy required by the user's solution. Both solutions show an inaccuracy in their predictions, particularly as Mach number and/or angle of attack increases, because of their lack of viscous effects and any mechanisms to predict vortex development.

Yaros, S. F.↗

Local flow measurements at the inlet spike tip of a Mach 3 supersonic cruise airplane

The flow field at the left inlet spike tip of a YF-12A airplane was examined using at 26 deg included angle conical flow sensor to obtain measurements at free-stream Mach numbers from 1.6 to 3.0. Local flow angularity, Mach number, impact pressure, and mass flow were determined and compared with free-stream values. Local flow changes occurred at the same time as free-stream changes. The local flow usually approached the spike centerline from the upper outboard side because of spike cant and toe-in. Free-stream Mach number influenced the local flow angularity; as Mach number increased above 2.2, local angle of attack increased and local sideslip angle decreased. Local Mach number was generally 3 percent less than free-stream Mach number. Impact-pressure ratio and mass flow ratio increased as free-stream Mach number increased above 2.2, indicating a beneficial forebody compression effect. No degradation of the spike tip instrumentation was observed after more than 40 flights in the high-speed thermal environment encountered by the airplane. The sensor is rugged, simple, and sensitive to small flow changes. It can provide accurate imputs necessary to control an inlet.

Johnson, H. J.↗

Interference effects of aircraft components on the local blade angle of attack of a wing-mounted propeller

The aerodynamic interference effects on a propeller operating in the presence of different wing-body-nacelle combinations was studied. The unsteady blade angle of attack variation with azimuth angle by varying the pitch and yaw of the nacelle was minimized. Results indicate for the particular configuration of interest the minimum blade angle of attack variation occurred with the nacelle pitched downward 4.5 deg and yawed inward 3.0 deg.

Mendoza, J. P.↗