Search NASA⌕ Search

SEARCH · Search NASA

Results for “BESS control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impacts of Control Set-Points on Battery Energy Storage Performance for Peak Shaving Application

This article presents the impact of battery energy storage system’s (BESS) control triggers on its performance during peak shaving application. With the increasing deployment of BESS for load leveling and grid capacity relief, the sensitivity of BESS performance to its set-points is yet to be investigated. Most utilities have defined thresholds for activating BESS control during peak demand leveling and baseload BESS charging. However, this study shows that without using optimal setpoints for control applications, the BESS can be under-utilized. Simulations results of the peak shaving algorithm implementation in 30-minute time step over a period of 10 years show the impact of different set-points on distribution transformer loading, line and system losses.

battery energy storage system↗

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

Active Damping With Energy Storage to Improve Power System Frequency Stability

As renewable resources displace traditional generation, there may be times when there is relatively less rotational inertia (H, MW-s) to stabilize power system frequency following a power system disturbance. This article outlines a method for the control of Battery Energy Storage System (BESS) to mitigate power system frequency disturbances. The control scheme discussed in the article leverages latest ‘smart grid’ technologies including PMU’s and advanced grid-supportive inverters. The authors’ screening-level analysis of this novel BESS control concept indicates the potential to increase the speed of recovery of disturbed power systems, i.e. return power system frequency to nominal value (60 Hz in N. America), following a system disturbance. Increasing power system stability by adding inertial-support from appropriately controlled BESS will help power systems accommodate more renewable generation before hitting stability limits.

Energy Storage↗

Regional Power System Black Start with Run-of-river Hydropower Plant and Battery Energy Storage

Battery energy storage systems (BESSs) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various critical services to the power grid. This paper presents the real-world experience of using a megawatt-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to restore a regional power system. To demonstrate this, we carry out power-hardware-in-the-loop experiments integrating an actual GFL- or GFM-controlled BESS and a load bank. Both the simulation and experimental results presented in this paper show the different roles of GFL- or GFM-controlled BESS in power system black starts. The results provide further insight for system operators on how GFL- or GFM-controlled BESS can enhance grid stability and how an ROR hydropower plant can be converted into a black-start-capable unit with the support of a small-capacity BESS. The results show that an ROR hydropower plant combined with a BESS has the potential of becoming one of enabling elements to perform bottom-up black-start schemes as opposed to conventional bottom-down method, thus enhancing the system resiliency and robustness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

Real-Time Inertia Estimation Tool Implementation Based on Probing Signals

As renewable energy penetration increases and the traditional generators retire in power grids, system inertia decreases and exhibits significant daily fluctuations. Furthermore, fast frequency responses (FFRs) provided by the inverter-based resources (IBRs) begin to playa very critical role and bring new challenges to real-time system inertia monitoring due to the difficulties of quantifying its artificial inertia contribution. Thus, necessitating an accurate real-time inertia estimation tool will not only benefit the secure power grid operations, but also provide insights on assessing the artificial inertia contribution from the IBRs. This paper presents a probing-based real-time inertia estimation tool that has been validated through a power-hardware-in-the-Ioop (PHIL) test system using identical hardware battery energy storage system (BESS) and control in an actual power grid. Preliminary results indicate high estimation accuracy of the developed tool and pave the way for the field test and deployment.

inverter-based resources↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-service battery energy storage system optimization and control

Battery energy storage systems (BESS) have become fundamental part of modern power systems due to their capability to provide multiple grid services. As the renewable penetration increases, BESS procurement is also expected to increase where it is envisioned to play a systematic and strategical role in power systems planning and operation. Hence, in this paper we present a multiple grid service procurement and operation for BESS - ranging from energy arbitrage, reserve/regulation services, power factor correction, and demand management. The proposed framework considers an optimal multi-temporal dimension, designed to be operable for both planning and real-time operation. Moreover, non-linearity inherent to BESS services and uncertainty associated to market forecasts variables are addressed using techniques such as polyhedral norms and robust optimization approaches. Here, the developed model is tested using a utility-scaled BESS and the obtained results show the effectiveness of the systematic BESS multi-service planning and operation approach.

25 ENERGY STORAGE↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Microgrid Power Flow Control with Integrated Battery Management Functions

This paper presents a microgrid power flow control for islanded microgrids consisting of photovoltaic (PV) system, battery energy storage system (BESS) and diesel generator. The proposed control ensures automatic coordination among the microgrid units. To achieve the coordination, the local control of PV system and BESS are configured to regulate power flow without relying on communications. The generator is controlled as the back-up source and its connection depends on battery state of charge (SOC). A state machine with hysteresis settings is used to trigger smooth transition among operation modes. Not only does the proposed controller consider battery SOC and power limits, but also integrates three-stage charging control as battery charging mechanism, which is not considered in the existing literature. The proposed control is validated for an islanded hybrid microgrid using an OPAL-RT real-time simulator.

Long, Qian↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Field Insights: Strengthening Digital Assurance Through On-Site Network Monitoring

The accelerating deployment of digital energy infrastructure, ranging from inverter-based resources (IBRs), battery energy storage systems (BESS), to advanced grid control platforms, has brought unprecedented visibility, flexibility, and efficiency to the electric grid. However, this digital transformation also introduces new cybersecurity challenges, particularly in the form of supply chain risks and operational blind spots at the grid edge. Over the past year, the Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through its Rapid Risk Assessment initiative, along with the Grid Deployment Office (GDO), through its Technical Assistance for Digital Assurance (TADA) initiative, have supported a series of on-site network engagements led by Idaho National Laboratory (INL). These engagements, conducted in partnership with asset owners across the country, have focused on identifying real-world vulnerabilities and misconfigurations in operational environments, many of which are not detectable through remote assessments or traditional compliance audits. The goal of this report is to distill key findings and lessons learned during network hunt engagements from INL’s fiscal year (FY) 2024 - 2025. It is intended to help asset owners—regardless of their participation in the program—better understand the evolving threat landscape and adopt practical measures to secure their digital energy infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating Operational Uncertainties into the Dispatch of an Integrated Solar and Storage System

The economic assessment of hybrid energy systems (HES) pairing battery energy storage systems (BESSs) and photovoltaics (PV) is highly important for advancing their deployment in power systems. This paper presents an innovative assessment framework, including an optimal control policy for dispatch under uncertainty and procedures for exploring control parameters that maximize economic benefits. The proposed dispatch policy consists of two steps using system forecast information. The first step is to determine whether a BESS will be used within an operational scheduling time frame based on the probability of events and their thresholds. Once the dispatch of BESS is triggered, a model predictive control (MPC) is carried out in the second step for scheduling using the expected value of system information. By exercising this policy with different thresholds, one can explore the trade-offs between short-term benefits and battery lifetime, and identify an optimal threshold that maximizes the total economic benefits within the battery lifetime. An evaluation study in a real-world HES project is presented to illustrate the proposed framework. Compared with traditional optimal dispatch algorithms, the proposed method can significantly improve the economic benefits of an HES scheduled under forecast uncertainties.

Ma, Xu↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗