Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biofluidics System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

Studying Microbial Adaptation in the Laboratory: Sensor & Control Upgrades for an Experimental Evolution Biofluidics System

Experimental evolution (EE) involves iteratively exposing a microbial community to specific stressors to study its response to changes in environment over time. EE work is commonly done manually in the laboratory, but, when there are many environmental variables to measure and adjust, it is highly labor intensive, prone to human error, and challenging to scale. Single-purpose automated continuous culturing chambers exist, but implement only limited stressor types. A more general-purpose design is desirable. The BeING Lab at Ames Research Center created the prototype Automated Adaptive Directed Evolution Chamber (AADEC) to address these problems, beginning with Escherichia coli tolerance of short-wave ultraviolet (UV-C) radiation and of temperature. In newer versions, AADEC monitors microbial activity and can adjust the UV-C and temperature levels automatically. An optical density measurement is used to determine how many cells are present in the growth medium—over time, this corresponds to how many survive and reproduce. Oxidation-reduction potential provides information on consumed metabolic energy, and pH and electrical conductivity on metabolic products. Dissolved oxygen content is used to determine aerobic vs anaerobic growth. A Raspberry Pi computer processes all this data to set the UV-C stressor level. AADEC’s auxiliary systems include peristaltic pumps to change media and agitation to counteract cell settling. These actuators can also act as additional stressors. With the Raspberry Pi monitoring sensors and adjusting actuators in real time, AADEC takes measurements and controls the environment much more accurately than can be done with a manual EE implementation. The third and latest AADEC iteration is the first to simplify design and usage with circuits on PCBs and the ability to pre-program experimental protocols. Still planned is expansion to a multi-well design for the study of varying cell cultures in parallel, which will enable researchers to retain and re-inoculate cultures exhibiting the desired trait most strongly while flushing out others. AADEC’s special capabilities make it a valuable tool for studying life under multiple stressors, enabling scientists to replicate changes in climate on microbes for study in a lab setting.

Microbial Adaptation↗

The Lunar Explorer Instrument for Space Biology Applications (LEIA) Pre-Flight Tests: Mechanical Considerations​

The BioSensor payload on the upcoming LEIA platform aboard the CLPS (CP-22) lander will carry yeast to the Moon's south pole to study the effects of lunar radiation and gravity. From Earth, BioSensor will transport desiccated yeast within 16 fluidic cards, each containing 16 fluidic wells of 100 microliters volume. At the start of the experiment, these microbes will be autonomously rehydrated on the Moon, and optical absorbance measurements at three wavelengths will be performed across all 256 wells. Absorbance measurements in fluidic wells are susceptible to noise and artifacts due to bubble formation during well rehydration and microbial growth. BioSensor, as a biofluidics system, faces significant data anomalies caused by payload vibrations, particularly from the operation of the co-located PROSPECT’s ProSEED drill, to assess lunar resources by penetrating the subsurface. To evaluate the impact of drill vibrations, fully assembled and filled fluidic cards were subjected to sine sweep signals in the x, y, z planes, ranging from 5 - 2560 Hz at g-loads of 0.25 and 0.5, with on-board accelerometer for localized vibration measurement. Wells with various fill conditions, including partial fills with different bubble sizes and completely filled wells, were tested. Results indicated that small bubbles adhered to well walls at high frequencies but were dislodged at low frequencies, causing data anomalies. Medium and large bubbles exhibited higher interference with optical data due to lower surface tension and variable bubble surface flexion. Overall, it was found that irrespective of the fill type, low-frequency vibrations were most detrimental to optical readings. Understanding the drill schedule and correlating it with BioSensor timestamps will help identify periods when BioSensor data is unreliable, a crucial step for accurately interpreting the microbial response data and ensuring the validity of the BioSensor's scientific measurements on the lunar surface.

Chinmayee Govinda Raj↗

Total Internal Reflection Tomography (TIRT) for Three-Dimensional Sub-Wavelength Imaging

We will present a novel new form of near-field microscopy known as total internal reflection tomography (TIRT), which allows for true three-dimensional sub-wavelength imaging. It is based on recent theoretical advances regarding the fundamental interaction of light with sub-wavelength structures, as well as stable algorithms for the near-field inverse problem. We will discuss its theoretical underpinnings, as well describe current efforts at the NASA Glenn Research Center to implement a TIRT system for biofluid research.

Fischer, David G.↗

The NASA Microgravity Fluid Physics Program: Knowledge for Use on Earth and Future Space Missions

Building on over four decades of research and technology development related to the behavior of fluids in low gravity environments, the current NASA Microgravity Fluid Physics Program continues the quest for knowledge to further understand and design better fluids systems for use on earth and in space. The purpose of the Fluid Physics Program is to support the goals of NASA's Biological and Physical Research Enterprise which seeks to exploit the space environment to conduct research and to develop commercial opportunities, while building the vital knowledge base needed to enable efficient and effective systems for protecting and sustaining humans during extended space flights. There are currently five major research areas in the Microgravity Fluid Physics Program: complex fluids, multiphase flows and phase change, interfacial phenomena, biofluid mechanics, and dynamics and instabilities. Numerous investigations into these areas are being conducted in both ground-based laboratories and facilities and in the flight experiments program. Most of the future NASA-sponsored fluid physics and transport phenomena studies will be carried out on the International Space Station in the Fluids Integrated Rack, in the Microgravity Science Glovebox, in EXPRESS racks, and in other facilities provided by international partners. This paper will present an overview of the near- and long-term visions for NASA's Microgravity Fluid Physics Research Program and brief descriptions of hardware systems planned to achieve this research.

Kohl, Fred J.↗

Tracking Metabolic Changes in Microbial Culture using Redox Measurements

During long-term space missions, microbial cultures accumulate the effects of low-dose radiation, microgravity, and other factors; altered growth and metabolic activity may occur before viability effects. This could affect functionality of bioreactors or other bio-enabled mission systems, as well as shed light on human health. Spaceflight microbiology studies beyond the low Earth orbit exposure afforded by the ISS have been limited. Nanosatellites offer an increasingly popular alternative for deep space missions. However, the communications delay requires biofluidic automation of a pre-defined experimental protocol, and the lack of sample return (reliance on sensors in flight) can significantly limit feasible investigations. Previous biological CubeSats (PharmaSat, O/OREOS, EcAMSat) have used alamarBlue, an off-the-shelf formulation of the redox indicator dye resazurin, to track metabolic activity, as will BioSentinel, the upcoming interplanetary microbiology experiment. A series of ground experiments (see abstracts by Liddell, Santa Maria, and A. Kim) were conducted using a microbial culture system outfitted with an electrochemical sensor array (electrical conductivity, pH, oxidation-reduction potential, and dissolved oxygen) with alamarBlue and the same strain of Saccharomyces cerevisiae as BioSentinel. By improving mapping of measured changes in alamarBlue kinetics to physicochemical changes, and ultimately to biological alterations such as shifted metabolic pathways, this work supplements data analyses from past missions and planning for future missions using alamarBlue to characterize space radiation effects. Initial results indicate that alamarBlue acts like a redox buffer; its presence significantly changes redox kinetics in otherwise identical cultures. The initial color change (blue resazurin reduced to red/pink resorufin) appears as a redox plateau. A second plateau, likely corresponding to the second color transition (resorufin to the colorless hydroresorufin), occurs at a lower redox value. The relationship to carbon source exhaustion, dissolved oxygen depletion, cell death, and measured redox potential is complex and still under study.

Tracking↗

BioSentinel: Mission Development of a Radiation Biosensor to Gauge DNA Damage and Repair Beyond Low Earth Orbit on a 6U Nanosatellite.

We are designing and developing a "6U" (10 x 22 x 34 cm; 14 kg) nanosatellite as a secondary payload to fly aboard NASA's Space Launch System (SLS) Exploration Mission (EM) 1, scheduled for launch in late 2017. For the first time in over forty years, direct experimental data from biological studies beyond low Earth orbit (LEO) will be obtained during BioSentinel's 12- to 18- month mission. BioSentinel will measure the damage and repair of DNA in a biological organism and allow us to compare that to information from onboard physical radiation sensors. In order to understand the relative contributions of the space environment's two dominant biological perturbations, reduced gravity and ionizing radiation, results from deep space will be directly compared to data obtained in LEO (on ISS) and on Earth. These data points will be available for validation of existing biological radiation damage and repair models, and for extrapolation to humans, to assist in mitigating risks during future long-term exploration missions beyond LEO. The BioSentinel Payload occupies 4U of the spacecraft and will utilize the monocellular eukaryotic organism Saccharomyces cerevisiae (yeast) to report DNA double-strand-break (DSB) events that result from ambient space radiation. DSB repair exhibits striking conservation of repair proteins from yeast to humans. Yeast was selected because of 1) its similarity to cells in higher organisms, 2) the well-established history of strains engineered to measure DSB repair, 3) its spaceflight heritage, and 4) the wealth of available ground and flight reference data. The S. cerevisiae flight strain will include engineered genetic defects to prevent growth and division until a radiation-induced DSB activates the yeast's DNA repair mechanisms. The triggered culture growth and metabolic activity directly indicate a DSB and its successful repair. The yeast will be carried in the dry state within the 1-atm P/L container in 18 separate fluidics cards with each card having 16 independent culture microwells, with integral microchannels and filters to supply nutrients and reagents, confine the yeast to the wells, and enable optical measurement. The measurement subsystem will monitor each subgroup of culture wells continuously for several weeks, optically tracking DSBtriggered cell growth and metabolism. BioSentinel will also include physical radiation sensors based on the TimePix sensor, as implemented by JSC's RadWorks group, which record individual radiation events including estimates of their linear-energytransfer (LET) values. Radiation-dose and LET data will be compared directly to the rate of DSB-and-repair events measured by the S. cerevisiae biosentinels. The spacecraft bus will operate in a deep space environment with functions that include command and data handling, communications, power generation (via deployable solar panels) and storage, and attitude determination-and-control system with micropropulsion. Development of the BioSentinel spacecraft will mature and prove multiple nanosatellite advances in order to function well beyond LEO: Communications from distances of ≥ 500,000 km; Autonomous attitude control, momentum management, and safe mode of nanosatellites in deep space; Shielding-, hardening-, design-, and software-derived radiation tolerance for electronics; Reliable functionality for 12 - 18 months of key subsystems for biofluidics, memory, communications, power, etc.; Close integration of living biological radiation event monitors with miniature physical radiation spectrometers; Biological measurement of solar particle events beyond Earth orbit In addition to providing the first biological results from beyond LEO in over 4 decades, BioSentinel will provide an adaptable small-satellite instrument platform to perform a range of human-exploration-relevant measurements that characterize the biological consequences of multiple outer space environments. BioSentinel is being developed under NASA's Advanced Exploration Systems program.

DNA damage↗

The NASA Microgravity Fluid Physics Program: Research Plans for the ISS

Building on over four decades of research and technology development related to the behavior of fluids in low gravity environments, the current NASA Microgravity Fluid Physics Program continues the quest for knowledge to further understand and design better fluids systems for use on earth and in space. NASA's Biological and Physical Research Enterprise seeks to exploit the space environment to conduct research supporting human exploration of space (strategic research), research of intrinsic scientific importance and impact (fundamental research), and commercial research. The strategic research thrust will build the vital knowledge base needed to enable NASA's mission to explore the Universe and search for life. There are currently five major research areas in the Microgravity Fluid Physics Program: complex fluids, niultiphase flows and phase change, interfacial phenomena, biofluid mechanics, and dynamics and instabilities. Numerous investigations into these areas are being conducted in both ground-based laboratories and facilities and in the flight experiments program. Most of the future NASA- sponsored flight experiments in microgravity fluid physics and transport phenomena will be carried out on the International Space Station (ISS) in the Fluids Integrated Rack (FIR), in the Microgravity Science Glovebox (MSG), in EXPRESS racks, and in other facilities provided by international partners. This paper presents an overview of the near- and long-term visions for NASA's Microgravity Fluid Physics Research Program and brief descriptions of hardware systems planned to enable this research.

Kohl, Fred J.↗

TPSAS-NF1676L-35311-DND

Objectives: - Inspect and identify the normal and abnormal cells, tissues, and biofluids (e.g., urine, serum, etc.) using a 532 nm pulsed laser within target distances of several centimeters (6 to 20 cm) and a line shaped laser spot-size 10 µm width by 5 mm height that would be suitable for astronauts’ health monitoring in space. Goals: - The goals of this research study are: - Solve some of the limitations of traditional micro-Raman systems (e.g., requires dark condition, sample collection, and slow) - build an instrument with pulsed-time gated Raman technology, operates in daylight, doesn’t require sample collection, and faster detection - Reduce the size and weight of the instrument - eliminate a high power laser and a large collection optics/telescope with a short working distance of several centimeters.

Nurul Abedin↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗