Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Digital Astronaut Project Biomechanical Models: Biomechanical Modeling of Squat, Single-Leg Squat and Heel Raise Exercises on the Hybrid Ultimate Lifting Kit (HULK)

The NASA Digital Astronaut Project (DAP) implements well-vetted computational models to predict and assess spaceflight health and performance risks, and to enhance countermeasure development. The DAP Musculoskeletal Modeling effort is developing computational models to inform exercise countermeasure development and to predict physical performance capabilities after a length of time in space. For example, integrated exercise device-biomechanical models can determine localized loading, which will be used as input to muscle and bone adaptation models to estimate the effectiveness of the exercise countermeasure. In addition, simulations of mission tasks can be used to estimate the astronaut's ability to perform the task after exposure to microgravity and after using various exercise countermeasures. The software package OpenSim (Stanford University, Palo Alto, CA) (Ref. 1) is being used to create the DAP biomechanical models and its built-in muscle model is the starting point for the DAP muscle model. During Exploration missions, such as those to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Therefore, the crew must have access to exercise countermeasures that can maintain their musculoskeletal and aerobic health. Exploration vehicles may have very limited volume and power available to accommodate such capabilities, even more so than the International Space Station (ISS). The exercise devices flown on Exploration missions must be designed to provide sufficient load during the performance of various resistance and aerobic/anaerobic exercises while meeting potential additional requirements of limited mass, volume and power. Given that it is not practical to manufacture and test (ground, analog and/or flight) all candidate devices, nor is it always possible to obtain data such as localized muscle and bone loading empirically, computational modeling can estimate the localized loading during various exercise modalities performed on a given device to help formulate exercise prescriptions and other operational considerations. With this in mind, NASA's Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) laboratory and NSBRI-funded researchers by developing and implementing well-validated computational models of exercises with advanced exercise device concepts. This report focuses specifically on lower-body resistance exercises performed with the Hybrid Ultimate Lifting Kit (HULK) device as a deliverable to the AEC Project.

health↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Unified Approach to the Biomechanics of Dental Implantology

The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.

Grenoble, D. E.↗

Biomechanical Analysis of Treadmill Locomotion on the International Space Station

Treadmill locomotion exercise is an important aspect of ISS exercise countermeasures. It is widely believed that an optimized treadmill exercise protocol could offer benefits to cardiovascular and bone health. If training heart rate is high enough, treadmill exercise is expected to lead to improvements in aerobic fitness. If impact or bone loading forces are high enough, treadmill exercise may be expected to contribute to improved bone outcomes. Ground-based research suggests that joint loads increase with increased running speed. However, it is unknown if increases in locomotion speed results in similar increases in joint loads in microgravity. Although data exist regarding the biomechanics of running and walking in microgravity, a majority were collected during parabolic flight or during investigations utilizing a microgravity analog. The Second Generation Treadmill (T2) has been in use on the International Space Station (ISS) and records the ground reaction forces (GRF) produced by crewmembers during exercise. Biomechanical analyses will aid in understanding potential differences in typical gait motion and allow for modeling of the human body to determine joint and muscle forces during exercise. By understanding these mechanisms, more appropriate exercise prescriptions can be developed that address deficiencies. The objective of this evaluation is to collect biomechanical data from crewmembers during treadmill exercise prior to and during flight. The goal is to determine if locomotive biomechanics differ between normal and microgravity environments and to determine how combinations of subject load and speed influence joint loading during in-flight treadmill exercise. Further, the data will be used to characterize any differences in specific bone and muscle loading during locomotion in these two gravitational conditions. This project maps to the HRP Integrated Research Plan risks including Risk of Bone Fracture (Gap B15), Risk of Early Onset Osteoporosis Due to Spaceflight (Gap B15), Risk of Impaired Performance Due to Reduced Muscle Mass, Strength, and Endurance (Gaps M3, M4, M6, Ml, M8, M9) and Risk of reduced Physical Performance Capabilities Due to Reduce Aerobic Capacity (Gaps M7, M8, M9).

De Witt, J. K.↗

Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include the applied device load and the dual cable long bar or single cable T-bar interface between the test subject and the device. Data is also obtained using free weights with the identical loading for a comparison to the resistively loaded exercise device trials. The data drives the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. RESULTS Lower body kinematics, joint moments, joint forces and muscle forces are obtained from the OpenSim biomechanical analysis of the squat exercises under different loading conditions. Preliminary results from the model for the loading conditions will be presented as will hypotheses developed for follow on work.

Human Factors Engineering↗

Microgravity-Driven Optic Nerve/Sheath Biomechanics Simulations

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Current thinking suggests that the ocular changes observed in VIIP syndrome are related to cephalad fluid shifts resulting in altered fluid pressures [1]. In particular, we hypothesize that increased intracranial pressure (ICP) drives connective tissue remodeling of the posterior eye and optic nerve sheath (ONS). We describe here finite element (FE) modeling designed to understand how altered pressures, particularly altered ICP, affect the tissues of the posterior eye and optic nerve sheath (ONS) in VIIP. METHODS: Additional description of the modeling methodology is provided in the companion IWS abstract by Feola et al. In brief, a geometric model of the posterior eye and optic nerve, including the ONS, was created and the effects of fluid pressures on tissue deformations were simulated. We considered three ICP scenarios: an elevated ICP assumed to occur in chronic microgravity, and ICP in the upright and supine positions on earth. Within each scenario we used Latin hypercube sampling (LHS) to consider a range of ICPs, ONH tissue mechanical properties, intraocular pressures (IOPs) and mean arterial pressures (MAPs). The outcome measures were biomechanical strains in the lamina cribrosa, optic nerve and retina; here we focus on peak values of these strains, since elevated strain alters cell phenotype and induce tissue remodeling. In 3D, the strain field can be decomposed into three orthogonal components, denoted as first, second and third principal strains. RESULTS AND CONCLUSIONS: For baseline material properties, increasing ICP from 0 to 20 mmHg significantly changed strains within the posterior eye and ONS (Fig. 1), indicating that elevated ICP affects ocular tissue biomechanics. Notably, strains in the lamina cribrosa and retina became less extreme as ICP increased; however, within the optic nerve, the occurrence of such extreme strains greatly increased as ICP was elevated (Fig. 2). In particular, c. 48 of simulations in the elevated ICP condition showed peak strains in the optic nerve that exceeded the strains expected on earth. Such extreme strains are likely important, since they represent a larger signal for mechano-responsive resident cells [2]. The models predicted little to no anterior motion of the prelaminar neural tissue (optic nerve swelling, or papilledema, secondary to axoplasmic stasis), typically seen with elevated ICP. Specialized FE models to capture axoplasmic stasis would be required to study papilledema. These results suggest that the most notable effect of elevated ICP may occur via direct optic nerve loading, rather than through connective tissue deformation. These FE models can inform the design of future studies designed to bridge the gap between biomechanics and pathophysiological function in VIIP.

biomechanics↗

Biomechanical Modeling of Split-leg Squat and Heel Raise on the Hybrid Ultimate Lifting Kit (HULK)

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and musculoskeletal forces that occur during exercises performed on the prototype devices. Computational models currently use OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from subjects for estimation of muscle and joint loads. Subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the loads on the body. Multiple exercises are performed and evaluated during a test session such as a full squat, single leg squat, heel raise and dead lift. Variables for these exercises include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data from free weights are compared to the resistively loaded exercise device. The focus of this presentation is to summarize the results from the single-leg squat and heel raise exercises performed during three sessions occurring in 2015. Differences in loading configuration, cadence and stance produce differences in kinematics, joint toques and force and muscle forces.

computational modeling↗

The genetic architecture of biomechanical traits in sorghum

Sorghum bicolor (L.) Moench is the fifth most commonly grown cereal crop worldwide with unrivaled drought tolerance compared with other cereal crops. Drought and heat tolerance and high biomass yield potential make sorghum a promising bioenergy crop. However, stem lodging is a significant problem that results in substantial yield losses. Stem biomechanical traits influence the mechanical stability of crops and breeding for desirable biomechanical traits may result in improved lodging resistance. In this study, we report the identification of quantitative trait loci (QTL) for stem mechanical and morphological traits in three recombinant inbred line (RIL; populations from Tx623/Rio, Tx623/Della, and Tx631/Della) crosses between elite grain and sweet sorghum parents. The genetic architecture of stem biomechanical traits in the three RIL populations is multigenic and pleiotropic. Additionally, eight QTL affecting mechanical and morphological traits were detected; two main effects of these QTL were consistently found in all populations and colocated with previously identified dwarfing genes Dw1 and Dw3. These results indicate that dwarfing genes affect the mechanical properties of sorghum stems and their lodging resistance, while also having demonstrable effects on stem morphology. The identification of these QTL provides new opportunities for improving stem lodging resistance via genomics-assisted breeding.

59 BASIC BIOLOGICAL SCIENCES↗

All arthroscopic remnant-preserving reconstruction of the lateral ligaments of the ankle: A biomechanical study and clinical application

Highlights: • Two surgical techniques of ATFL and CFL reconstruction produce similar the strength and stiffness • The strength and stiffness of reconstructed ATFL and CFL are weaker than the intact, uninjured ATFL and CFL. • All arthroscopic remnant-preserving reconstruction of ATFL and CFL has good short-term clinical effect. Lateral ankle sprains are one of the most common injuries in sports. Recently, arthroscopic lateral ligament reconstruction has been recently advocated, however no biomechanical studies and clinical application of this technique are available. In this biomechanical study, eighteen fresh-frozen cadaveric ankles were randomized into three groups: (1) intact anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL), (2) arthroscopic anatomic reconstruction of ATFL and CFL, and (3) all arthroscopic remnant-preserving reconstruction of ATFL and CFL. The specimens were then tested for stiffness and load to ultimate failure using a customized jig. In biomechanical test, the all arthroscopic remnant-preserving reconstruction of ATFL and CFL produced a reconstruction that could withstand loads to failure and stiffness similar to the arthroscopic anatomic reconstruction. However, both two reconstruction groups were much weaker than the intact, uninjured ATFL and CFL. Moreover, we used the technique of all arthroscopic remnant-preserving reconstruction of ATFL and CFL on 20 patients from September 2016 to September 2017. American Orthopaedic Foot and Ankle Society (AOFAS) scores and Anterior Talar Translation (ATT) were applied for statistical collection at preoperative and postoperative 12 months to evaluate clinical efficacy. The differences of the preoperative and postoperative 12 months AOFAS scores and ATT of patients were both statistical significant (P < 0.01). We confirmed that all arthroscopic remnant-preserving reconstruction of ATFL and CFL exhibited positive effect, thus promoting the recovery of ankle function and had good short-term clinical effect.

60 APPLIED LIFE SCIENCES↗

Biomechanical Comparison of Anatomic Restoration of the Ulnar Footprint vs Traditional Ulnar Tunnels in Ulnar Collateral Ligament Reconstruction

Background: Current techniques for ulnar collateral ligament (UCL) reconstruction do not reproduce the anatomic ulnar footprint of the UCL. The purpose of this study was to describe a novel UCL reconstruction technique that utilizes proximal-to-distal ulnar bone tunnels to better re-create the anatomy of the UCL and to compare the biomechanical profile at time zero among this technique, the native UCL, and the traditional docking technique. Hypothesis: The biomechanical profile of the anatomic technique is similar to the native UCL and traditional docking technique. Study Design: Controlled laboratory study. Methods: Ten matched cadaveric elbows were potted with the forearm in neutral rotation. The palmaris longus tendon graft was harvested, and bones were sectioned 14 cm proximal and distal to the elbow joint. Specimen testing included (1) native UCL testing performed at 90° of flexion with 0.5 N·m of valgus moment preload, (2) cyclic loading from 0.5 to 5 N·m of valgus moment for 1000 cycles at 1 Hz, and (3) load to failure at 0.2 mm/s. Elbows then underwent UCL reconstruction with 1 elbow of each pair receiving the classic docking technique using either anatomic (proximal to distal) or traditional (anterior to posterior) tunnel locations. Specimen testing was then repeated as described. Results: There were no differences in maximum load at failure between the anatomic and traditional tunnel location techniques (mean ± SD, 34.90 ± 10.65 vs 37.28 ± 14.26 N·m; P = .644) or when including the native UCL (45.83 ± 17.03 N·m; P = .099). Additionally, there were no differences in valgus angle after 1000 cycles across the anatomic technique (4.58°± 1.47°), traditional technique (4.08°± 1.28°), and native UCL (4.07°± 1.99°). The anatomic group and the native UCL had similar valgus angles at failure (24.13°± 5.86° vs 20.13°± 5.70°; P = .083), while the traditional group had a higher valgus angle at failure when compared with the native UCL (24.88°± 6.18° vs 19.44°± 5.86°; P = .015). Conclusion: In this cadaveric model, UCL reconstruction with the docking technique utilizing proximal-to-distal ulnar tunnels better restored the ulnar footprint while providing valgus stability comparable with reconstruction with the docking technique using traditional anterior-to-posterior ulnar tunnel locations. These results suggest that utilization of the anatomic tunnel location in UCL reconstruction has similar biomechanical properties to the traditional method at the time of initial fixation (ie, not accounting for healing after reconstruction in vivo) while keeping the ulnar tunnels farther from the ulnar nerve. Further studies are warranted to determine if an anatomically based UCL reconstruction results in differing outcomes than traditional reconstruction techniques. Clinical Relevance: Current UCL reconstruction techniques do not accurately re-create the ulnar UCL footprint. The UCL is a dynamic constraint to valgus loads at the elbow, and a more anatomic reconstruction may afford more natural joint kinematics. This more anatomic technique performs similarly to the traditional docking technique at time zero, and the results of this study may offer a starting point for future in vivo studies.

Chang, Edward S.↗

Integrating biomechanics in evolutionary studies, with examples from the amphidromous goby model system

The functional capacities of animals are a primary factor determining survival in nature. In this context, understanding the biomechanical performance of animals can provide insight into diverse aspects of their biology, ranging from ecological distributions across habitat gradients to the evolutionary diversification of lineages. To survive and reproduce in the face of environmental pressures, animals must perform a wide range of tasks, some of which entail tradeoffs between competing demands. Moreover, the demands encountered by animals can change through ontogeny as they grow, sexually mature or migrate across environmental gradients. To understand how mechanisms that underlie functional performance contribute to survival and diversification across challenging and variable habitats, we have pursued diverse studies of the comparative biomechanics of amphidromous goby fishes across functional requirements ranging from prey capture and fast-start swimming to adhesion and waterfall climbing. The pan-tropical distribution of these fishes has provided opportunities for repeated testing of evolutionary hypotheses. By synthesizing data from the lab and field, across approaches spanning high-speed kinematics, selection trials, suction pressure recordings, mechanical property testing, muscle fiber-type measurements and physical modeling of bioinspired designs, we have clarified how multiple axes of variation in biomechanical performance associate with the ecological and evolutionary diversity of these fishes. Here our studies of how these fishes meet both common and extreme functional demands add new, complementary perspectives to frameworks developed from other systems, and illustrate how integrating knowledge of the mechanical underpinnings of diverse aspects of performance can give critical insights into ecological and evolutionary questions.

59 BASIC BIOLOGICAL SCIENCES↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗

Squat Biomechanical Modeling Results from Exercising on the Hybrid Ultimate Lifting Kit

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. The computational models currently under development utilize the OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from test subjects for estimation of muscle and joint loads. The subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. Test variables include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data is also obtained using free weights for a comparison to the resistively loaded exercise device. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. The focus of this presentation is to summarize the results from the full squat exercises across the different test variables.

Bioengineering↗

Biomechanical Modeling of the Deadlift Exercise to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures

During long-duration spaceflight missions, astronauts exposure to microgravity without adequate countermeasures can result in losses of muscular strength and endurance, as well as loss of bone mass. As a countermeasure to this challenge, astronauts engage in resistive exercise during spaceflight to maintain their musculoskeletal function. The Hybrid Ultimate Lifting Kit (HULK) has been designed as a prototype exercise device for an exploration-class vehicle; the HULK features a much smaller footprint than previous devices such as the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS), which makes the HULK suitable for extended spaceflight missions in vehicles with limited volume. As current ISS exercise countermeasure equipment represents an improvement over previous generations of such devices, the ARED is being employed as a benchmark of functional performance. This project involves the development of a biomechanical model of the deadlift exercise, and is novel in that it is the first exercise analyzed in this context to include the upper limbs in the loading path, in contrast to the squat, single-leg squat, and heel raise exercises also being modeled by our team. OpenSim software is employed to develop these biomechanical models of humans performing resistive exercises to assess and improve the new exercise device designs. Analyses include determining differences in joint and muscle forces when using different loading strategies with the device, comparing and contrasting with the ARED benchmark, and determining whether the loading is sufficient to maintain musculoskeletal health. During data collection, the number of repetitions, load, cadence, stance, and grip width are controlled in order to facilitate comparisons between loading configurations. To date, data have been collected for two human subjects performing the deadlift exercise on the HULK device using two different loading conditions. Recorded data include motion capture, electromyography (EMG), ground reaction forces, device load cell data, photos and videos, and anthropometric data. Work is ongoing to perform biomechanical analyses including inverse kinematics and inverse dynamics to compare different versions of the deadlift model in order to determine which provides an appropriate level of detail to study this exercise. This work is supported by the National Space Biomedical Research Institute through NCC 9-58.

physical exercise↗

Biomechanical and Cortical Control of Tongue Movements During Chewing and Swallowing

Tongue function is vital for chewing and swallowing and lingual dysfunction is often associated with dysphagia. Better treatment of dysphagia depends on a better understanding of hyolingual morphology, biomechanics, and neural control in humans and animal models. Recent research has revealed significant variation among animal models in morphology of the hyoid chain and suprahyoid muscles which may be associated with variation in swallowing mechanisms. The recent deployment of XROMM (X-ray Reconstruction of Moving Morphology) to quantify 3D hyolingual kinematics has revealed new details on flexion and roll of the tongue during chewing in animal models, movements similar to those used by humans. XROMM-based studies of swallowing in macaques have falsified traditional hypotheses of mechanisms of tongue base retraction during swallowing, and literature review suggests that other animal models may employ a diversity of mechanisms of tongue base retraction. There is variation among animal models in distribution of hyolingual proprioceptors but how that might be related to lingual mechanics is unknown. In macaque monkeys, tongue kinematics—shape and movement—are strongly encoded in neural activity in orofacial primary motor cortex, giving optimism for development of brain–machine interfaces for assisting recovery of lingual function after stroke. However, more research on hyolingual biomechanics and control is needed for technologies interfacing the nervous system with the hyolingual apparatus to become a reality.

59 BASIC BIOLOGICAL SCIENCES↗

Biomechanical drivers of the evolution of butterflies and moths with a coilable proboscis

Current biomechanical models suggest that butterflies and moths use their proboscis as a drinking straw pulling nectar as a continuous liquid column. Our analyses revealed an alternative mode for fluid uptake: drinking bubble trains that help defeat drag. We combined X-ray phase-contrast imaging, optical video microscopy, micro-computed tomography, phylogenetic models of evolution and fluid mechanics models of bubble-train formation to understand the biomechanics of butterfly and moth feeding. Our models suggest that the bubble-train mechanism appeared in the early evolution of butterflies and moths with a proboscis long enough to coil. We propose that, in addition to the ability to drink a continuous column of fluid from pools, the ability to exploit fluid films by capitalizing on bubble trains would have expanded the range of available food sources, facilitating diversification of Lepidoptera.

Palaoro, Alexandre V.↗