Chlorine Nuclear Data Evaluation Aided Through New LANSCE Measurements

The collaboration between the Los Alamos National Laboratory Neutron Science Center (LANSCE) and TerraPower LLC enables the enhanced understanding of fast spectrum critical systems consisting of chlorine. Specifically, TerraPower is interested in updating the nuclear data for the stable isotopes of chlorine, 35 Cl and 37 Cl, because these nuclides are the primary constituents of the chloride fuel salt in the Molten Chloride Reactor Experiment (MCRE), for which TerraPower is leading the design. The Cooperative Research and Development Agreement (CRADA) between the parties is funded by DOE’s Office of Nuclear Energy’s Gateway for Accelerated Innovation in Nuclear (GAIN) initiative to provide the nuclear community with access to the technical, regulatory, and financial support necessary to motivate innovative nuclear reactor technologies toward commercialization. New measurements of 35 Cl(n,p total ) and 35 Cl(n,α total ) were completed at LANSCE to constrain the reaction theory models that are used to generate the updated evaluations. The updated evaluations were then tested across the sensitivities of the MCRE by TerraPower to provide direct feedback to the evaluation for application specific sensitivities.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

R -matrix analysis of n + nat Cl reactions up to 1.2 MeV

The R -matrix analysis of neutron-induced reactions for two stable chlorine isotopes ( 35 Cl and 37 Cl) was performed in the energy range of thermal up to 1.2 MeV. Starting from the repository of the ENDF/B-VIII.0 library and following recent measurement series, this work represents a significant improvement, particularly in the evaluation of the ( n , p ) reaction channel. The evaluation methodology used the R -matrix code SAMMY to generate a set of Reich–Moore resonance parameters for both stable chlorine isotopes. Consistent with recently measured 35 Cl( n , p ) data, the presented evaluation features a dramatic increase in the magnitude of the ( n , p ) reaction channel over the ENDF/B-VIII.1 nuclear data library and previous ENDF/B libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

$\mathcal{R}$ -matrix analysis of η + nat Cl reactions relevant to molten-salt reactor designs [Abstract]

Performed with support from the U.S. Nuclear Criticality Safety Program in an effort to provide improved chlorine cross section and corresponding covariance data, the R-matrix analysis of neutron induced reactions for two stable chlorine isotopes, 35,37 Cl, was performed in the energy range of thermal up to 1.2 MeV. Starting from the repository of the ENDF/B-VIII.0 library and following recent measurement campaigns, this work represents a significant improvement in the evaluation of the ( η , p ) reaction channel. The evaluation methodology uses the $\mathcal{R}$ -matrix code SAMMY to generate a set of Reich-Moore resonance parameters. As predicted by recently measured 35 Cl( η , p ) data, the presented evaluation features a dramatic increase in the magnitude of the ( η , p ) reaction channel over the ENDF/B-VIII.0 and previous nuclear data ENDF/B released libraries. Together with details of the evaluation procedure, the impact of the updates in the outgoing proton emissions on reactivity coefficients for different molten-salt reactor designs is presented and discussed.

charged-particle↗

The Galactic Chemical Evolution of Chlorine

We measured {sup 35}Cl abundances in 52 M giants with metallicities in the range −0.5 < [Fe/H] < 0.12. Abundances and atmospheric parameters were derived using infrared spectra from CSHELL on the NASA Infrared Telescope Facility and from optical echelle spectra. We measured Cl abundances by fitting a H{sup 35}Cl molecular feature at 3.6985 μm with synthetic spectra. We also measured the abundances of O, Ca, Ti, and Fe using atomic absorption lines. We find that the [Cl/Fe] ratio for our stars agrees with chemical evolution models of Cl, and the [Cl/Ca] ratio is broadly consistent with the solar ratio over our metallicity range. Both indicate that Cl is primarily made in core-collapse supernovae with some contributions from Type Ia supernovae. We suggest that other potential nucleosynthesis processes, such as the ν-process, are not significant producers of Cl. Finally, we also find our Cl abundances are consistent with H ii and planetary nebular abundances at a given oxygen abundance, although there is scatter in the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chlorine isotope separations using thermal diffusion

In a chloride molten salt fast reactor (Cl-MSFR), the fuel salt might be comprised of a specific eutectic composition of alkali and alkaline chlorides that solubilize major and minor actinide chlorides as the fertile component(s). Each of the chloride species contain the natural abundance ( 35 Cl ~76% and 37 Cl ~24%) of the two stable isotopes of chlorine 35 Cl and 37 Cl. There has been an ongoing controversy for the operation of the Cl-MSFRs concerning the potential of the 35 Cl(n,γ) 36 Cl, 35 Cl(n,p) 35 S, 35 Cl(n,α) 32 S reactions to produce 36 Cl, 32 S, and 32 P at relevant energies [Bulmer 1956]. The undesirable attributes of irradiated 35 Cl are enumerated further below.

07 ISOTOPE AND RADIATION SOURCES↗

Isotopic discrimination of natural and anthropogenic perchlorate sources in groundwater in a semi-arid region of northeastern Oregon (USA)

Perchlorate (ClO 4 - ) has synthetic and natural sources. Synthetic ClO 4 - is released to the environment from its use as an oxidant in military and aerospace applications, and from its presence in a variety of common commercial products, such as safety flares, chlorate herbicides, and fireworks. Natural sources of ClO 4 - in the environment include imported nitrate fertilizers derived from salt deposits in the Atacama Desert of Chile and indigenous natural ClO 4 - that accumulates in unsaturated soils and groundwaters in other arid and semi-arid environments, largely from atmospheric deposition. The stable isotope ratios of chlorine ( 37 Cl/ 35 Cl) and oxygen ( 18 O/ 16 O, 17 O/ 16 O) and the isotopic abundance of radioactive 36 Cl in ClO 4 - can be used to discriminate these different sources. Perchlorate was previously detected at relatively high concentrations (3.8–34.7 μg/L) in groundwater from many wells in the Boardman-Umatilla area near the Columbia River in northeastern Oregon, which is a semi-arid, highly agricultural, heavily irrigated area that includes several past and current military installations. Eight representative groundwater wells were sampled throughout this region and isotopic characteristics of ClO 4 - collected from each well were measured along with other chemical and isotopic parameters including tritium and other groundwater age indicators. We report isotopic data indicate that indigenous natural ClO 4 - was present in groundwater from all sampled wells and was the predominant source in five of the wells. Synthetic ClO 4 - was present in the three remaining wells with natural ClO 4 - , and a minor fraction of Atacama-fertilizer-derived ClO4- was indicated in one of the wells. Data from this study expand the geographic area of the USA in which indigenous natural ClO 4 - has been detected to include the semi-arid northwest. This study also illustrates the role of irrigation recharge as a mechanism for producing relatively high concentrations of indigenous natural ClO 4 - in groundwater by flushing accumulated salts from the unsaturated zone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chlorination of Hydrogenated Silicon Nanosheets Revealed by Solid-State Nuclear Magnetic Resonance Spectroscopy

We report two-dimensional silicon nanosheets (Si-NS) synthesized by topotactic deintercalation of CaSi 2 are hypothesized to consist of buckled layers of sp 3 -hybridized silicon atoms that are bonded to three other framework Si atoms and a terminal atom or functional group such as H, Cl, or OH. Here, we apply 1 H{ 35 Cl} and 29 Si{ 35 Cl} Resonance-Echo Saturation-Pulse DOuble-Resonance (RESPDOR) solid-state NMR experiments to directly confirm the presence of chlorinated Si atoms within Si-NS. Plotting the 1 H{ 35 Cl} RESPDOR dephasing as a function of the 35 Cl saturation pulse offset reveals that the 35 Cl quadrupolar coupling constant (C Q ) is 38 MHz, consistent with Cl atoms that are covalently bonded to silicon. Modeling the 1 H{ 35 Cl} RESPDOR dephasing curve shows that the Si–Si interlayer spacing is approximately 6 Å. Plane-wave density functional theory (DFT) calculations show that the direct band gap transition of the Si-NS decreases with increasing chlorination and hydroxylation, suggesting that the band gap of Si-NS can be tuned by modifying the terminal atoms or functional groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Solid Form of Erlotinib: Synthesis by Heterogeneous Complexation and Characterization by NMR Crystallography

We describe the synthesis of a novel complex of the anticancer "active pharmaceutical ingredient erlotinib (ERL) via heterogeneous nucleation on polished zinc tiles. The resulting product, ERL 2 ·ZnCl 2 , is characterized by single-crystal X-ray diffraction, multinuclear solid-state NMR (ssNMR) spectroscopy, and density functional theory (DFT) calculations. Also characterized are the hydrochloride salt (ERL·HCl) and monohydrate free base (ERL·H 2 O) forms of erlotinib. 13 C ssNMR spectroscopy is useful for site-by-site assignment and rapid fingerprinting, while also providing preliminary structural interpretations, such as the number of molecules in the asymmetric unit. 35 Cl ssNMR can readily differentiate between the chloride ions in ERL·HCl and the covalently bonded chlorine in ERL 2 ·ZnCl 2 . 15 N ssNMR proves to be critical here because of the large isotropic chemical shift differences between ERL·H 2 O, ERL·HCl, and ERL 2 ·ZnCl 2 . The 15 N chemical shift tensors are linked directly to differences in structure and bonding with the aid of DFT calculations. Together, these results demonstrate the utility of multinuclear NMR crystallography for the characterization of solid forms of APIs, especially when other analytical techniques face significant challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IER-499 Final Design of a TEX Variant: Chlorine to Support NNSA Operations [Slides]

This presentation concludes the final design of TEX with chlorine absorbers is complete. 5 configurations were identified, expected to down select to three experimental configurations. Great comparison to Y-12 and good comparison to INL sensitivities. Fastest configuration touches on the 35 Cl(n,p) cross section (continuing to work with Terrapower for faster configurations). Extensive density studies performed to ensure understanding of the salt in the plates. Reactivity studies performed to assist with experiment. Finally, the fabrication of the chlorine absorbers is ongoing (with LANL), and the experiment is scheduled to be completed this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lost and Found Opportunities Around the Chlorine Worth Study

Los Alamos National Laboratory performed a series of critical experiments in 2021 to examine the worth of chlorine in plutonium-fueled systems. This series of experiments has been dubbed the “Chlorine Worth Study,” and the evaluation of the experiments was presented to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Technical Review Group in April, 2023. The primary purpose of these experiments was to enable validation of aqueous solutions crediting neutron absorption in 35 Cl. An external, independent view of the events leading up to the design and execution of these experiments indicates a missed opportunity to leverage sensitivity/uncertainty (S/U) analysis to assert validation without the experiments by taking an additional margin for the lack of direct validation of chlorine. On the other hand, the execution of these experiments also presents a rare opportunity to examine the efficacy of the S/U approach and extract useful information about the evaluated chlorine covariance data. TSUNAMI-1D models of representative application solutions were created and used to generate sensitivity data. Varying plutonium and chlorine concentrations were considered to examine the impact of these differences on the chlorine sensitivities and uncertainties. The data-induced uncertainty in k eff resulting from chlorine was calculated directly from uncertainty information calculated in the TSUNAMI-1D sequence. In all cases, this uncertainty was less than 0.1 %Δk. This result could potentially be used to justify a reactivity margin to account for the validation gap related to chlorine in the validation set. On the other hand, given that the experiments were performed, the community should endeavor to extract as much value from them and their results as possible. The results can be used to examine the actual bias associated with chlorine in these systems once the evaluations have been released. These data can be compared with the data-induced uncertainty margin discussed above to test the sufficiency of the validation gap penalty. This result will provide an indication of the performance of the chlorine covariance data specifically and the S/U validation approach generally. More advanced S/U techniques may also be employed to determine reactivity sensitivities associated with the chlorine in the experiments, potentially generating a more robust test of the chlorine covariance data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design Optimization of a Criticality Experiment for the Molten Chloride Reactor Experiment Facility

Neutronics simulations of Molten Chloride Fast Reactors have quantifiable biases that arise from nuclear data, modeling choices, or numerical methods. The multiphysics nature of molten salt reactors makes it challenging to disentangle neutronics modeling biases from biases originating from other physical phenomena. In comparison to a mock-up reactor, criticality experiments can specifically assess the neutronics modeling bias while limiting multiphysics effects. The criticality experiment must be neutronically representative of the full-scale reactor to be valuable. Here, in this paper, we describe the design of a criticality experiment to validate only the neutronics of TerraPower’s Molten Chloride Reactor Experiment (MCRE) and its criticality safety upset scenarios. The proposed experiment uses different chlorine-containing materials to maximize its similarity to the MCRE. The design process uses a constrained Bayesian optimization algorithm to investigate different objective functions that use covariance information for 35 Cl nuclear data. The experiments could reduce the nuclear data–induced uncertainty in k eff of the MCRE from 2161 to 886 pcm. They would also increase the upper subcritical limit of the MCRE criticality safety upset scenario from 0.94101 to 0.94476 when using the WHISPER analysis framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel Method for Domestic Stable Isotope Production

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species ( 35 Cl- and 37 Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗

Final Design for Additional Thermal/Epithermal eXperiments (TEX) with Sodium Chloride Absorbers to Provide Validation Benchmarks for TerraPower

The first set of Thermal/Epithermal eXperiments (TEX) with chlorine absorbers (TEX-Cl) were executed in Q4FY24 and are in the process of being benchmarked for the ICSBEP. TEX-Cl builds upon the TEX-HEU baseline cases that were published in the 2022 International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. TEX-HEU, like TEX-Pu, was designed to be modular to allow for the incorporation of various absorbers and reflectors to test nuclear data and application case needs. For example, TEX-HEU with hafnium (TEX-Hf) utilizes hafnium plates as both absorbers and reflectors, depending on the tested configuration. A second set of chlorine experiments, dubbed More TEX-Cl, are laid out in this report to meet the needs of TerraPower for chlorine validation for their Molten Chloride Fast Reactor (MCFR) systems. TerraPower’s Molten Chloride Reactor Experiment (MCRE) and MCFR are fast molten salt reactors that utilize sodium chloride (NaCl) salt eutectics as the fuel and coolant. The MCRE eutectic is a mixture of NaCl and uranium trichloride (UCl 3 ). An abundant need for chlorine absorption validation has been expressed by multiple members of the community, including Y-12 (whose needs were addressed with the first set of experiments), LANL (whose needs were addressed with the Chlorine Worth Study (CWS)), TerraPower, institute de radioprotection et de sûreté nucléaire (IRSN), Savannah River Nuclear Solutions (SNRS), and others. Of the members who have expressed interest in this validation, most are interested in the fast neutron energy region, where the 35 Cl(n,p) reaction is most prominent. New 35 Cl(n,p) differential cross section measurements performed by LANL at LANCSE show substantial changes to the cross sections (Figure 1) and may be validated through these experiments as some configurations are optimally sensitive to this cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strong mutual increase in the efficiency of isotope-selective laser IR dissociation of molecules under nonequilibrium thermodynamic conditions of the compression shock under irradiation in a bimolecular mixture

We have revealed a strong (by a factor of 2 to 5) mutual increase in the yield of IR molecular dissociation (by the example of CF{sub 2}HCl and CF{sub 3}Br) and a significant (by a factor of 1.5 to 3) lowering of dissociation thresholds in the nonequilibrium thermodynamic conditions of compression shock in the irradiation of the molecules by resonance IR laser radiation in the bimolecular mixture in comparison with their individual irradiation. This opens up the possibility to perform efficient isotope-selective IR dissociation of molecules at lower excitation energy densities (Φ ⩽ 1.5 – 2.0 J cm{sup −2}) and thereby to improve the dissociation selectivity. This was demonstrated by the example of chlorine- and bromine-isotope selective dissociation of the specified molecules, which are characterised by quite small (less than 0.25 cm{sup −1}) isotope shifts in the IR vibrational absorption spectra excited by laser radiation. The enrichment coefficients K {sub enr}({sup 35}Cl / {sup 37}Cl) = 0.90 ± 0.05 in the residual CF{sub 2}HCl gas and K {sub enr}({sup 79}Br / {sup 81}Br) in the resultant Br{sub 2} product are obtained when the CF{sub 2}HCl : CF{sub 3}Br = 1 : 1 molecular mixture and CF{sub 3}Br molecules, respectively, are irradiated by the 9R(30) CO{sub 2} laser line (frequency, 1084.635 cm{sup −1}) at an energy density Φ ≈ 1.3 J cm{sup −2}. (laser isotope separation)