Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLD CATHODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of energetic electrons on near-wall sheath voltage in the cathode region of a cold cathode direct current discharge

It is experimentally demonstrated that energetic electrons originating from the cathode or produced in volumetric processes in the cathode region of a cold cathode direct current discharge can create a large potential drop in the near-wall sheath. This voltage drop may be much greater than kT{sub e}/e (where k is the Boltzmann constant, T{sub e} is the electron temperature, and e is the electron charge). Due to the large near-wall sheath voltage, slow and moderately energetic electrons cannot reach the wall and move toward the anode. Application of additional potentials to the wall can change the amount of energetic electrons reaching the wall. This effect can be used for regulation of the near-cathode plasma and near-wall sheath properties and thus may be useful in technical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved magnetron cold-cathode ion source

Cold cathode ionization source generates smaller amounts of spurious gases and has a higher sensitivity than commonly used hot-filament ion sources. Photon and X-ray background noise are reduced below detectable levels.

Roehrig, J.↗

Nanostructure TEM analysis of diamond cold cathode field emitters

Diamond cold cathode devices have demonstrated significant potential as electron field emitters. Ultra-sharp diamond pyramidal tips (~5nm tip radius) have been fabricated and show improvement in emission when compared to conventional field emitters. However, the emission mechanisms in these complex diamond nanostructures are not well understood. Transmission electron microscopy performed in this study provides new insight into tip structure and composition with implications for field emission and diamond growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cold cathode gauge experiment (ALSEP)

Cold cathode ionization gages were left on the lunar surface as part of ALSEP (Apollo Lunar Surface Experiment Package) on Apollo missions 12, 14, and 15. An instrument prepared for Apollo 13 did not reach the surface because of the abort of that mission. The gages that reached the lunar surface measured the amounts of gas present in the vicinity of the ALSEP sites. The observed daytime gas concentrations were initially about two orders of magnitude greater than the nighttime observations; this was due to contamination of the landing area by the Apollo operations and equipment, and the daytime measurements showed a decrease with time characterized by a time constant of a few months.

Johnson, F. S.↗

Cold cathode switching device and converter

A cold-cathode switching device is presented. The cold-cathode switching device includes a housing defining a chamber; an ionizable gas disposed in the chamber; and a plurality of electrodes disposed in the chamber. The plurality of electrodes includes a cathode and an anode defining a discharge gap, and wherein at least one of the cathode and anode comprises a material that is liquid at an operating temperature of the cathode or the anode.

42 ENGINEERING↗

CO2 laser cold cathode study

The procedure for evaluating reliable sputter-free cold cathodes for carbon dioxide lasers is discussed. The purpose of the development is to obtain cold cathodes with service life in excess of 10,000 hours. Discharge tubes are used to eliminate the materials which would be unsatisfactory for use as a cold cathode. A description of the facility for producing the discharge tubes is described. The gas monitoring technique for determining discharge tube performance is examined. Discharge characteristics of tubes with various metals for cathode material are presented in chart form.

Hochuli, U.↗

Verification of high efficient broad beam cold cathode ion source

An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold cathodes for sealed off CO2 lasers

Experimental results of a group of theoretically selected cold cathode materials are presented. These tests indicate Ag-CuO, Cu and Pt-Cu as three new cold cathode materials for sealed off CO2 lasers. The power output of a test with an Ag-CuO cathode and a gas volume of only 50 cubic centimeters varied from 0.72 W to 1.1 W at 3000 hours and yields still 0.88 W after 8000 hours. Gas discharge tubes with Cu cathodes and a volume of 25 cubic centimeters yield life times in excess of 10,000 hours. Gas analysis results, obtained from a similar tube over a period of 3000 hours, look most promising. A Pt-Cu alloy cathode shows an extremely promising V-I characteristic over a period of 2800 hours.

Hochuli, U.↗

Cold cathodes for sealed off CO2 lasers

Experimental results of a group of theoretically selected cold cathode materials are presented. These tests indicate Ag-CuO, Cu, and Pt-Cu as three new cold cathode materials for sealed-off CO2 lasers. The power output of a test laser with an Ag-CuO cathode and a gas volume of only 50 cu cm varied from 0.72 W to 1.1 W at 3000 hours and still yields 0.88 W after 8000 hours. Gas discharge tubes with Cu cathodes and a volume of 25 cu cm yield lifetimes in excess of 10,000 hours. Gas analysis results, obtained from a similar tube over a period of 3000 hours, look most promising. A Pt-Cu alloy cathode shows an extremely promising V-I characteristic over a period of 2800 hours.

Hochuli, U. E.↗

Operating modes of a magnetized cold cathode plasma in helium 50–6400 mTorr

We characterize the operating modes of a magnetized cold cathode plasma in helium at pressures 50–6400 mTorr (6.7–850 Pa). We find at least three distinct modes: (i) a diffuse magnetron plasma with representative plasma voltage 250 V; (ii) a constricted mode with a bright spot at the cathode surface that moves slowly, with representative plasma voltage 50 V; and, (iii) a constricted mode (CO) with a bright spot at the cathode surface that orbits rapidly around the racetrack region defined by the magnetic field, with representative plasma voltage 80 V. This latter mode is of interest because it appears to be a cold-cathode plasma operating at unusually low voltage, and it is associated with a low rate of cathode mass-loss. We find that the CO mode appears only if the initial rate of current-rise is high, and if the cathode surface is smooth and featureless. It also appears to be correlated with cathode materials that form strong oxide films that can dramatically increase the field emission of electrons from the cathode surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold cathode ionization gage has rigid metal housing

Cold cathode ionization gage in a stainless steel housing accurately measures high pressures. The penning effect is used with a high voltage discharge in the presence of a magnetic field for an ion current proportional to the gas pressure in the gage.

Herzog, R.↗