Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance of Compressor of XJ-41-V Turbojet Engine VI - Analysis of Compressor Flow Choking: Analysis of Compressor Flow Choking - 6

An extended analysis was made of the previously reported performance investigation of the original compressor from the XJ-41-v turbojet engine and a similar compressor revised a to obtain a 33-percent increase in the geometric passage area at the vaned-collector entrance. This analysis was based on the concept of the vaned-collector entrance as the throat section of a nozzle. Because of nonuniform air distribution at the vaned-collector entrance, approximately 90 percent of the available flow area was utilized in the original compressor and 94percent in the revised com$ressor. The increase in maximum weight flow obtained with the revised compressor was disproportionate to the increased effective critical throat area because. the air density at the revised vaned-collector entrance for maximum flow was lower than that obtained in the original compressor. This reduction in density resulted from the large pressure losses near the impeller inlet of the revised compressor, which is indicative of impending flow choking in the impeller, The.calculated maximum corrected weight-flow capacity of a compressor consisting of the revised vaneless diffuser and vaned collector with a theoretical impeller that combined peak impeller pressure ratio and peak impeller efficiency at the . maximum flow point would be 112 pounds per second for an equivalent impeller speed of 11,500 rpm;

Creagh, John W. R.↗

Performance of Compressor of XJ-41-V Turbojet Engine: Compressor Static-Pressure Rise at Equivalent Compressor Speeds of 5000, 7000, 8000, and 9000 rpm - 3

At the request of the Air Materiel Command, Army Air Forces, an investigation is being conducted at the NACA Cleveland laboratory to determine the performance characteristics of the XJ-41-V turbojet-engine compressor. The static-pressure variation in the direction of flow through the compressor was presented in reference 1 for an equivalent speed of 8000 rpm. An analysis of these pressure indicated that the maximum-flow limitation of the compressor was caused by separation, which reduced the effective flow area at the vaned-collector entrance. As a result of this analysis, the flow area at the vaned-collector entrance was increased to obtain larger mass flows. The area increase was obtained by cutting back the entrance edges of the collector vanes, which resulted in an increased vaneless-diffuser radius. Comparative performance of the original and revised compressors at an equivalent speed of 8000 rpm is presented. The static-pressure rise through the compressor, determined from static pressures at the impeller entrance and the vaned-collector exit, is also presented together with the compressor adiabatic efficiency and the mass flow over an equivalent speed range from 5000 to 9000 rpm. These static-pressure data are presented for the purpose of correlating the compressor performance with the turbojet-engine performance.

Creagh, John W. R.↗

Performance of Compressor of XJ-41-V Turbojet Engine V-Performance Analysis of Compressor with Revised Vaned Collector over Range of Compressor Speeds from 3600 to 11,500 RPM

An investigation of the XJ-41-V turbojet-engine compressor with a revised vaned collector was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal compressors of this type. The original vaned collector was revised by increasing the flow area at the vaned collector entrance. A maximum adiabatic efficiency of 0.81 was obtained et a corrected weight flow of 36.5 pounds per second and a pressure ratio of 1.90. The peak pressure ratio was 3.93 and occurred at an impeller speed of 11,500 rpm at a corrected weight flow of 65.5 pounds per second. Revision of the vaned collector resulted in an increased airflow capacity over the speed range. The design air-flow capacity of 78 pounds per second was very nearly reached at the engine design speed of 11,500 rpm. The compressor air-flow choking point occurred in the vaned collector passage; however, at speeds above 8300 rpm, the air-flow capacity of the impeller was being approached as indicated by large pressure losses in the impeller at maximum air-flow conditions. An increase in compressor air-flow capacity at the higher speeds can possibly be obtained 5y removal of the flow restriction in the impeller, which would result in an increased air density at the vaned collector entrance.

Ginsburg, Ambrose↗

Performance of Axial-Flow Supersonic Compressor on XJ-55-FF-1 Turbojet Engine. I - Preliminary Performance of Compressor: Preliminary Performance of Compressor - 1

An investigation was conducted to determine the performance characteristics of the axial-flow supersonic compressor of the XJ-55-FF-1 turbo Jet engine. The test unit consisted of a row of inlet guide vanes and a supersonic rotor; the stator vanes after the rotor were omitted. The maximum pressure ratio produced in the single stage was 2.28 at an equivalent tip speed or 1814 feet per second with an adiabatic efficiency of approximately 0.61, equivalent weight flow of 13.4 pounds per second. The maximum efficiency of 0.79 was obtained at an equivalent tip speed of 801 feet per second.

Hartmann, Melvin J.↗

Performance of Compressor XJ-41-V Turbojet Engine I - Preliminary Investigation at Equivalent Compressor Speed of 8000 RPM

At the request of the Air Material Command, Arm Air Forces, an investigation was conducted at the NACA Cleveland laboratory to determine the performance characteristics of the XJ-41-V turbojet-engine compressor. The complete compressor was mounted on a collecting chamber having an annular air-flow passage simulating the burner annulus of the engine and was driven by an electric motor. The compressor was extensively instrumented to determine the overall performance of the compressor, the characteristic performance of each of the compressor components, the state of the air stream in the simulated burner annulus, and the operation of the compressor bearings. An initial investigation at an equivalent compressor speed of 8000 rpm was made to determine the performance of the compressor and the collecting chamber and to determine the similarity of the air stream at the entrance to the simulated burner annulus. The mechanical performance of the compressor over a range of actual compressors speeds from 3300 to 8000 rpm is reported.

Ginsburg, Ambrose↗

Performance of Compressor of XJ-41-V Turbojet Engine: Performance Analysis Over Range of Compressor Speeds from 5000 to 10,000 RPM - 4

An investigation of the XJ-41-V turbojet-engine compressor was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal-type compressors. The results of the research conducted on the original compressor indicated the compressor would not meet the desired engine-design air-flow requirements because of an air-flow restriction in the vaned collector. The compressor air-flow choking point occurred near the entrance to the vaned-collector passage and was instigated by a poor mass-flow distribution at the vane entrance and from relatively large negative angles of attack of the air stream along the entrance edges of the vanes at the outer passage wall and large positive angles of attack at the inner passage wall. As a result of the analysis, a design change of the vaned collector entrance is recommended for improving the maximum flow capacity of the compressor.

John W R Creagh↗

Preliminary Results of Altitude-Wind-Tunnel Investigation of X24C-4B Turbojet Engine. IV - Performance of Modified Compressor: Performance of Modified Compressor - Part 4

The performance of the 11-stage axial-flow compressor, modified to improve the compressor-outlet velocity, in a revised X24C-4B turbojet engine is presented and compared with the performance of the compressor in the original engine. Performance data were obtained from an investigation of the revised engine in the MACA Cleveland altitude wind tunnel. Compressor performance data were obtained for engine operation with four exhaust nozzles of different outlet area at simulated altitudes from 15,OOO to 45,000 feet, simulated flight Mach numbers from 0.24 to 1.07, and engine speeds from 4000 to 12,500 rpm. The data cover a range of corrected engine speeds from 4100 to 13,500 rpm, which correspond to compressor Mach numbers from 0.30 to 1.00.

Thorman, H. Carl↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/heccdata/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

Prediction of compressor stall for distorted and undistorted flow by use of a multistage compressor simulation on the digital computer

A simulation technique is presented for the prediction of compressor stall for axial-flow compressors for clean and distorted inlet flow. The simulation is implemented on the digital computer and uses stage stacking and lumped-volume gas dynamics. The resulting nonlinear differential equations are linearized about a steady-state operating point, and a Routh-Hurwitz stability test is performed on the linear system matrix. Parallel compressor theory is utilized to extend the technique to the distorted inlet flow problem. The method is applied to the eight-stage J85-13 compressor.

Daniele, C. J.↗

Prediction of compressor stall for distorted and undistorted flow by use of a multistage compressor simulation on the digital computer

A simulation technique is presented for the prediction of compressor stall for axial-flow compressors for clean and distorted inlet flow. The simulation is implemented on the digital computer and uses stage stacking and lumped-volume gas dynamics. The resulting nonlinear differential equations are linearized about a steady-state operating point, and a Routh-Hurwitz stability test is performed on the linear system matrix. Parallel compressor theory is utilized to extend the technique to the distorted inlet flow problem. The method is applied to the eight-stage J85-13 compressor. Analytical stall prediction for the undistorted stall line shows good agreement with experimental results. The predicted stall line for distorted inlet flow is in agreement with experimental results only for large distortion extents and/or low distortion levels. Results for low distortion extents and high distortion level do not agree with experimental results.

Daniele, C. J.↗

Performance of Allison Model 400-C6 Turbojet-Engine Compressor: Over-All Performance Characteristics of Compressor at Equivalent Impeller Speeds of 6000, 7000, and 8500 RPM - I

The Allison model 400-C6 compressor was operated at an inlet pressure of 12 inches of mercury absolute ana ambient inlet temperature at equivalent impeller speeds of 6000, 7000, and 8500 rpm. Additional runs at an equivalent speed of 7000 rpm and ambient inlet temperature were made at inlet pressures from 7 to 22 inches of mercury absolute. The results of this investigation are compared with those of the 533-A-23 compressors. For the speeds investigated, the Allison model 400-C6 compressor had a maximum adiabatic temperature-rise efficiency of 0.768 at an equivalent speed of 7000 rpm; the corresponding equivalent weight flow was 45.0 pounds per second and the pressure ratio was 1.83. At an equivalent impeller speed of 8500 rpm, the maximum equivalent weight flow was 61.6 pounds per second and the peak pressure ratio of 2.38 occurred at an equivalent weight flow of 52.2 pounds per 1 second and an adiabatic temperature-rise efficiency of 0.714. At an equivalent speed of 7000 rpm, increasing the compressor- inlet pressure increased the maximum equivalent weight flow and the pressure ratio.

Kovach, Karl↗

Investigation of turbines suitable for use in a turbojet engine with high compressor pressure ratio and low compressor-tip speed I : turbine-design requirements for several engine operating conditions

In order to insure satisfactory turbine performance under five turbojet-engine operating conditions, turbine design requirements were determined for the following operating conditions: take-off, maximum thrust at altitude, altitude cruising at rated rotative speed, altitude cruising with maximum-thrust exhaust nozzle area, and engine acceleration at 80 percent equivalent design rotative speed. If cruising is to be at rated engine speed, both cruising and take-off should be considered in turbine design. Design requirements for the other conditions are nearly identical. Without compressor-exit bleed, a turbine cannot accelerate this compressor at 80 percent of rated speed; with 28.6-percent bleed, the design requirements are within those for take-off.

TURBINES--AXIAL FLOW↗

Performance of J33-A-27 Turbojet-Engine Compressor: Over - All Performance Characteristics of Modified Compressor at Equivalent Impeller Speeds from 6100 to 13,250 RPM - II

A modified J33-A-27 compressor was operated over a range of equivalent impeller speeds from 6100 to 13,250 rpm in order to obtain the over-all compressor performance. At the equivalent design speed of 11,800 rpm, the maximum efficiency of 0.764 and peak pressure ratio of 4.56 occurred at an equivalent weight flow of 104.07 pounds per second. At the highest equivalent speed (13,250 rpm) a maximum efficiency of 0.711, a maximum equivalent weight flow of 123.00 pounds per second, and a peak pressure ratio of 5.76 were obtained.

Beede, William L.↗

Preliminary Results of Altitude-Wind-Tunnel Investigation of X34C-4B Turbojet Engine. III - Compressor Performance: Compressor Performance - 3

The performance of the 11-stage axial-flow compressor in the X24C-4B turbojet engine was analyzed on the basis of results obtained from an investigation of the complete engine in the NACA Cleveland altitude wind tunnel. The engine was operated with four, exhaust nozzles of different outlet area over a range of engine speeds from 6000 to 12,500 rpm, corrected engine speeds from approximately 6100 to 13,600 rpm, and compressor Mach numbers from 0.45 to 1.00. Data are presented for engine operation over a range of simulated altitudes from 15,000 to 45,000 feet and simulated flight Mach numbers from 0.24 to 1.08.

Dupree, David T.↗

Performance of J33-A-27 Turbojet-Engine Compressor: Over-All Performance Characteristics of Modified Compressor with Water Injection at Design Equivalent Speed of 11,800 RPM - III

An investigation was conducted to determine the effects of water injection on the over-all performance of a modified J33-A-27 turbojet-engine compressor at the design equivalent speed of 11,800 rpm. The water-air ratio by weight was 0.05. With water injection the peak pressure ratio increased 9.0 per- cent, the maximum efficiency decreased 15 percent (actual numerical difference 0.12), and. the maximum total weight flow increased 9.3 percent.

Withee, Joseph R., Jr.↗

Compressor Flow Control Concepts: UEET Compressor Flow Control Modeling - 2

Several passive flow control devices have been modeled computationally in the Swift CFD code. The models were applied to the first stage rotor and stator of the baseline UEET compressor in an attempt to improve efficiency and/or stall margin. The devices included suction surface bleed, tip injection, self-aspirated rotors, area-ruled casing, and vortex generators. The models and computed results will be described in the presentation. None of the results have shown significant gains in efficiency; however, casing vortex generators have shown potential improvements in stall margin.

Chima, Rodrick V.↗