Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTINUOUS WAVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION↗

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Investigation of Oxides of Tantalum Produced by Pulsed Laser Ablation and Continuous Wave Laser Heating

Recent progress has seen multiple Ta 2 O 5 polymorphs generated by different synthesis techniques. However, discrepancies arise when these polymorphs are produced in widely varying thermodynamic conditions and characterized using different techniques. This work aimed to characterize and compare Ta 2 O 5 particles formed at high and low temperatures using nanosecond pulsed laser ablation (PLA) and continuous wave (CW) laser heating of a local area of tantalum in either air or an 18 O 2 atmosphere. Scanning electron microscopy (SEM) and Raman spectroscopy of the micrometer-sized particles generated by PLA were consistent with either a localized amorphous Ta 2 O 5 phase or a similar, but not identical, crystalline β-Ta 2 O 5 phase. The Raman spectrum of the material formed at the point of CW laser impingement was in good agreement with the previously established ceramic “H-Ta 2 O 5 ” phase. TEM and electron diffraction analysis of these particles indicated the phase structure matched an oxygen-vacated superstructure of monoclinic H-Ta 2 O 5 . Further from the point of laser impingement, CW heating produced particles with a Raman spectrum that matched β-Ta 2 O 5 . We confirmed that the high-temperature ceramic phase characterized in previous work by Raman spectroscopy was the same monoclinic phase characterized in different work by TEM and could be produced by direct laser heating of metal in air.

36 MATERIALS SCIENCE↗

Characterization of Gramicidin A in Triblock and Diblock Polymersomes and Hybrid Vesicles via Continuous Wave Electron Paramagnetic Resonance Spectroscopy

Studying membrane proteins in a native environment is crucial to understanding their structural and/or functional studies. Often, widely accepted mimetic systems have limitations that prevent the study of some membrane proteins. Micelles, bicelles, and liposomes are common biomimetic systems but have problems with membrane compatibility, limited lipid composition, and heterogeneity. To overcome these limitations, polymersomes and hybrid vesicles have become popular alternatives. Polymersomes form from amphiphilic triblock or diblock copolymers and are considered more robust than liposomes. Hybrid vesicles are a combination of lipids and block copolymers that form vesicles composed of a mixture of the two. These hybrid vesicles are appealing because they have the native lipid environment of bilayers but also the stability and customizability of polymersomes. Gramicidin A was incorporated into these polymersomes and characterized using continuous wave electron paramagnetic resonance (CW-EPR) and transmission electron microscopy (TEM). EPR spectroscopy is a powerful biophysical technique used to study the structure and dynamic properties of membrane proteins in their native environment. Spectroscopic studies of gramicidin A have been limited to liposomes; in this study, the membrane peptide is studied in both polymersomes and hybrid vesicles using CW-EPR spectroscopy. Lineshape analysis of spin-labeled gramicidin A revealed linewidth broadening, suggesting that the thicker polymersome membranes restrict the motion of the spin label more when compared to liposome membranes. Statement of Significance: Understanding membrane proteins’ structures and functions is critical in the study of many diseases. In order to study them in a native environment, membrane mimetics must be developed that can be suitable for obtaining superior biophysical data quality to characterize structural dynamics while maintaining their native functions and structures. Many currently widely accepted methods have limitations, such as a loss of native structure and function, heterogeneous vesicle formation, restricted lipid types for the vesicle formation for many proteins, and experimental artifacts, which leaves rooms for the development of new biomembrane mimetics. The triblock and diblock polymersomes and hybrid versicles utilized in this study may overcome these limitations and provide the stability and customizability of polymersomes, keeping the biocompatibility and functionality of liposomes for EPR studies of membrane proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring the Moisture Content of Wood Sheathing with Continuous Wave Radars

Radars were studied for measuring the moisture content of wood-based materials because of their non-destructive nature and their ability to measure the moisture content of several layers at once. These convenient characteristics enable a quick and non-invasive method to find areas of high moisture content in building envelopes so that problems can be fixed before the structure degrades. The need to operate the radar at millimeter ranges required the development of new techniques and methods for analyzing and calculating the moisture content of individual layers of building material. The techniques are providing accurate results for oriented strand board, and efforts are continuing for investigating other construction materials, meeting FCC requirements, and building a system that will be easy to deploy.

Killough, Stephen M↗

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗

Search for continuous gravitational wave signals from luminous dark photon superradiance clouds with LVK O3 observations

Superradiance clouds of kinetically mixed dark photons around spinning black holes can produce observable multimessenger electromagnetic and gravitational wave signals. The cloud generates electric fields of up to a teravolt-per-meter, which leads to a cascade production of charged particles, yielding a turbulent quasiequilibrium plasma around the black hole, and resulting in electromagnetic fluxes ranging from supernova to pulsar-like luminosities. For stellar mass black holes, such systems resemble millisecond pulsars and are expected to emit pulsating radio waves and continuous gravitational waves (CWs) within the LIGO-Virgo-KAGRA (LVK) sensitivity band. We select 44 sources with approximately coincident frequencies or positive frequency drifts from existing pulsar catalogs as potential candidates of long-lasting superradiance clouds around old Galactic black holes. For a subset of 34 sources that are well measured and have not been previously targeted, we perform the first search for CW emission in LVK data from the third observing run. We find no evidence of a CW signal and place 95% confidence level upper limits on the emitted strain amplitude. We interpret these results, together with limits from previous searches, in terms of the underlying dark photon theory by performing an analysis of the expected signals from superradiance clouds from Galactic black holes. Finally, we find that, even for moderately spinning black holes, the absence of an observed CW signal disfavors a discrete set of dark photon masses between about 10 −13 and 10 −12 eV/c 2 and kinetic mixing couplings in the range of 10 −9 –10 −7 , subject to assumptions about the properties of the black hole population and the cloud’s electromagnetic emission.

astronomical black holes↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport of 12 GeV positron beams at Ce+BAF

Jefferson Lab (JLab) is developing a concept to upgrade the Continuous Electron Beam Accelerator Facility (CEBAF) to additionally deliver spin-polarized continuous-wave positron beams for its nuclear physics program users (Ce+BAF 12 GeV). The concept involves repurposing the Low Energy Recirculator Facility (LERF) at JLab as a dual injector, first producing 100-300 MeV spin-polarized electron beams which are subsequently used for the generation and formation of 123 MeV continuous-wave positron beams. The positron beams are transported to CEBAF and injected for acceleration up to 12 GeV, tailored to the requirements of its four experimental halls. Given the higher emittance of the secondary positron beams, the CEBAF optics are optimized for low dispersion and low beta functions to enhance transmission within the Ce+BAF acceptance limits and with an R56 to manage the positron beams bunch length and energy spread. Potential bottlenecks are being investigated through both optical modeling and measurements using an electron beam, as well as degraded electron beams, to map the 6d acceptance of CEBAF as it is today. This presentation shares preliminary results from multi-particle tracking simulations of the positron beam up to 12 GeV, including spatial, momentum, and spin characteristics, and explores the feasibility of delivering beams simultaneously to multiple experimental halls via extraction optics.

Accelerator Physics↗

BEAM ACCELERATION WITH A Nb3Sn CRYOMODULE AT JLAB

We report on the electron beam acceleration experiment with a Nb3Sn cryomodule at Thomas Jefferson National Laboratory (JLAB). Two CEBAF-style 5-cell 1.5 GHz Nb3Sn cavities operated at 4 K, accelerating a 100 nA continuous-wave (CW) electron beam from 200 keV to 4 MeV at JLAB’s Upgraded Injector Test Facility (UITF). The acceleration gradients in each cavity reached 11 MV/m and 7 MV/m, respectively. No field emission was observed. The unloaded quality factors reached 2¿109 at low fields at 4 K.

Geng, R. [Thomas Jefferson National Accelerator Fa↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Phase-resolving spin-wave microscopy using infrared strobe light

The need for sensitively and reliably probing magnetization dynamics has been increasing in various contexts such as studying novel hybrid magnonic systems, in which the spin dynamics strongly and coherently couple to other excitations, including microwave photons, light photons, or phonons. Recent advances in quantum magnonics also highlight the need for employing the magnon phase as quantum state variable, which is to be detected and mapped out with high precision in on-chip micro- and nanoscale magnonic devices. Here, in this study, we demonstrate a facile optical technique that can directly perform concurrent spectroscopic and imaging functionalities with spatial and phase resolutions, using infrared strobe light operating at 1550-nm wavelength. To showcase the methodology, we spectroscopically studied the phaseresolved spin dynamics in a bilayer of Permalloy and yttrium iron garnet Y 3 Fe 5 O 12 (YIG), and spatially imaged the backward-volume spin-wave modes of YIG in the dipolar spin-wave regime. Using the strobe light probe, the detected precessional phase contrast can be directly used to construct the map of the spin wave's wave front, in the continuous-wave regime of spin-wave propagation and in the stationary state, without needing any optical reference path. By selecting the applied field, frequency, and detection phase, the spin-wave images can be made sensitive to the precession amplitude and phase. Our results demonstrate that infrared optical strobe light can serve as a versatile platform for magneto-optical probing of magnetization dynamics, with potential implications in investigating hybrid magnonic systems.

Xiong, Yuzan [University of North Carolina, Chapel↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Wang, S.↗

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel↗

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗