Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSCs Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses on its surface area to create a high vacuum environment of 5*10-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to validate thermal models. High temperature tests could benefit from reduced heater demand with an insulated shroud while still sustaining the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform thermal analyses to assess the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Methods for Cryopumping Xenon

Design Characteristics of a cryopump optimized for xenon are presented. The cost and complexity of installing and operating these cryopumps is a fraction of the cost and complexity to install and operate diffusions pumps or cryopumps that deliver similar pump speeds on xenon.

electric↗

From diffusion pumps to cryopumps: The conversion of GSFC's space environment simulator

The SES (Space Environmental Simulator), largest of the Thermal Vacuum Facilities at The Goddard Space Flight Center, recently was converted from an oil diffusion pumped chamber to a Cryopumped chamber. This modification was driven by requirements of flight projects. The basic requirement was to retain or enhance the operational parameters of the chamber such as pumping speed, ultimate vacuum, pump down time, and thermal system performance. To accomplish this task, seventeen diffusion pumps were removed and replaced with eight 1.2 meter (48 inch) diameter cryopumps and one 0.5 meter (20 inch) turbomolecular pump. The conversion was accomplished with a combination of subcontracting and in-house efforts to maximize the efficiency of implementation.

Cary, Ron↗

Cryopumping in Cryogenic Insulations for a Reusable Launch Vehicle

Testing at cryogenic temperatures was performed to verify the material characteristics and manufacturing processes of reusable propellant tank cryogenic insulations for a Reusable Launch Vehicle (RLV). The unique test apparatus and test methods developed for the investigation of cryopumping in cryogenic insulations are described. Panel level test specimens with various types of cryogenic insulations were subjected to a specific thermal profile where the temperature varied from -262 C to 21 C. Cryopumping occurred if the interior temperature of the specimen exhibited abnormal temperature fluctuations, such as a sudden decrease in temperature during the heating phase.

Johnson, Theodore F.↗

A cryopump for cooling objects at a distance

Design and construction of cryopump is reported that feeds from primary source to cool component up to 30 ft from source. Liquid oxygen or nitrogen is gravity fed through loop system to copper fibers enclosing component at room temperature where fluid boils, cools object, vaporizes and recycles through tubing loop.

Batson, P. J.↗

Use of cryopumps on large space simulation systems

The need for clean, oil free space simulation systems has demanded the development of large, clean pumping systems. The assurance of optically dense liquid nitrogen baffles over diffusion pumps prevents backstreaming to a large extent, but does not preclude contamination from accidents or a control failure. Turbomolecular pumps or ion pumps achieve oil free systems but are only practical for relatively small chambers. Large cryopumps were developed and checked out which do achieve clean pumping of very large chambers. These pumps can be used as the original pumping system or can be retrofitted as a replacement for existing diffusion pumps.

Mccrary, L. E.↗

Cryopumping Field Joint Can Testing

For long installations, vacuum jacketed piping often comes in 40 foot sections that are butt welded together in the field. A short can is then welded over the bare pipe connection to allow for insulation to be protected from the environment. Traditionally, the field joint is insulated with multilayer insulation and a vacuum is pulled on the can to minimize heat leak through the bare section and prevent frost from forming on the pipe section. The vacuum jacketed lines for the Ares I mobile launch platform were to be a combined 2000 feet long, with 60+ pipe sections and field joint cans. Historically, Kennedy Space Center has drilled a hole in the long sections to create a common vacuum with the field joint can to minimize maintenance on the vacuum jacketed piping. However, this effort looked at ways to use a passive system that didn't require a vacuum, but may cryopump to create its own vacuum. Various forms of aerogel, multilayer insulations, and combinations thereof were tested to determine the best method of insulating the field joint while minimizing maintenance and thermal losses.

Johnson, Wesley L.↗

Advantages of cryopumping with liquid hydrogen instead of helium refrigerators

Open loop hydrogen vaporizers and helium refrigerators are compared for operational complexity, installation and operating cost, and safety requirements. Data from two vacuum chambers using helium refrigerators are used to provide comparative data. In general, the use of hydrogen is attractive in the larger systems, even when extra safety precautions are taken. Emotional resistance to the use of hydrogen because of safety requirements is considered great. However, the experience gained in the handling of large quantities of cryogenics, particularly hydrogen and liquefied natural gases, should be considered in the design of open loop hydrogen cooling systems.

J.W. Anderson↗

Cryopump for large pulses of hydrogen

A test involving a flow of hot hydrazine decomposition products at a rate of 13.6 g/s (0.03 lb/s) established the requirement to maintain pressure in an 11.9-m-(39 ft) diameter space chamber below 200 microns. The flow, 2/3 hydrogen and 1/3 nitrogen by volume, continued for several periods ranging from 3 to 15 min. The pressure requirement was necessary to minimize thermal effects of the gas on the test vehicle but was well beyond the capability of the existing facility pumps. Various methods of obtaining additional temporary jump capacity were considered. From these, the slugged-charcoal approach was selected as the quickest and least expensive method to implement.

Moore, B. C.↗

Recovering Residual Xenon Propellant for an Ion Propulsion System

Future nuclear-powered Ion-Propulsion- System-propelled spacecraft such as Jupiter Icy Moon Orbiter (JIMO) will carry more than 10,000 kg of xenon propellant. Typically, a small percentage of this propellant cannot be used towards the end of the mission because of the pressure drop requirements for maintaining flow. For large missions such as JIMO, this could easily translate to over 250 kg of unusable xenon. A proposed system, the Xenon Recovery System (XRS), for recovering almost all of the xenon remaining in the tank, would include a cryopump in the form of a condenser/evaporator that would be alternatively cooled by a radiator, then heated electrically. When the pressure of the xenon in the tank falls below 0.7 MPa (100 psia), the previously isolated XRS will be brought online and the gas from the tank would enter the cryopump that is initially cooled to a temperature below saturation temperature of xenon. This causes xenon liquefaction and further cryopumping from the tank till the cryopump is full of liquid xenon. At this point, the cryopump is heated electrically by small heaters (70 to 80 W) to evaporate the liquid that is collected as high-pressure gas (<7 MPa; 1,000 psia) in an intermediate accumulator. Check valves between the tank and the XRS prevent the reverse flow of xenon during the heating cycle. The accumulator serves as the high-pressure source of xenon gas to the Xenon Feed System (XFS) downstream of the XRS. This cycle is repeated till almost all the xenon is recovered. Currently, this system is being baselined for JIMO.

Ganapathi, Gani↗