Status of Cable Aging Knowledge Gaps Identified in the Expanded Materials Degradation Assessment (EMDA)

This report summarizes research relevant to cable aging knowledge gaps identified in NUREG/CR-7153, “Expanded Materials Degradation Assessment (EMDA) Volume 5: Aging of Cables and Cable Systems” (EMDA Vol. 5), performed since the EMDA Vol. 5 was published in 2014. It begins with a discussion of the status of cables in long-term operation of U.S. nuclear power plants (NPPs) and the most common cables found in NPP containment. Next, the major polymer cable insulations, and the mechanisms of concern for degradation of those polymers in service are reviewed. A description of the environmental qualification (EQ) process historically used for safety-related cables is provided as is a review of the potential concerns with that process highlighted in the EMDA Vol. 5. Research addressing each of these is then reviewed. Finally, three potential strategies to support continued safe operation of aging cables are proposed: advanced condition-based verification, targeted material aging studies, and predictive simulation.

42 ENGINEERING↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

Extension of Cable Electrical Assessment Techniques to Detect and Discriminate Radiation Aging on Cable Insulation Systems (Abstract)

The purpose of this study of the electrical responses of gamma radiation aged low voltage nuclear cables is to advance tools to determine cable condition (extent of damage) and identify degradation location along the cable length. The developed technology will provide nuclear plant operators with the options to focus cable repair, mitigation, or replacement efforts locally and avoid wholesale cable replacement.

42 ENGINEERING↗

Radiation Aging of Cable Insulation Systems to Support Extension of Cable Electrical Assessment Techniques - CRADA 562 (Final Report)

Radiation aging (primarily gamma radiation) affects a small subset of the LV cable population based on a 40-year operation. Increasing plant operating life to 60 or 80 years will result in additional cables experiencing degradation, either from radiation or from combined thermal and radiation effects. Previous research work done by EPRI and other researchers focuses on electrical diagnostics of thermal effects. However, the electrical diagnostic response of the cable system to radiation aging is minimally understood. In order to study the electrical responses from XLPE and EPR cabling and correlate these responses with radiation dose and level of thermal exposure, gamma radiation testing was performed at Pacific Northwest National Laboratory (PNNL). This report covers the radiation testing performed at PNNL, which involved irradiation of 30-foot long cables and short witness samples. The cabling was irradiated, at room temperature, using cobalt-60 gamma-rays to intervals of 10 million rads (10 Mrads), for a maximum of 70 Mrads. The results can be used to determine cable conditions (extent of damage) more accurately and localize where the degradation exists along the length of the cable (axial location). These insights can provide operators with the options to focus repair, mitigation, or replacement efforts locally.

36 MATERIALS SCIENCE↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Correlation of Diffusion Limited Oxidation to Color Difference in Accelerated Aging of Electrical Cable Insulation

Diffusion limited oxidation (DLO) as a phenomenon has complicated material lifetime predictions from accelerated aging studies. Many methods to analyze DLO have been developed in recent years. However, an analytical tool for high throughput and low-cost analysis of DLO affected samples remains absent from the literature. Color differences in polymers exposed to oxidative conditions have recently been observed and correlated to increased concentrations of oxidation products. Herein, total color difference was utilized to rapidly quantify DLO in ethylene propylene rubber (EPR) polymeric cable insulation specimens. Insulation specimens were aged at 121 °C, 136 °C, 150 °C, and 165 °C and a 10% ?E*ab difference between the specimen edge and specimen center was used as the threshold for DLO. Based on these specifications DLO was observed in EPR insulation specimen at temperatures of 136 °C and above, with an increasing degree of DLO observed as the time of exposure increased. The method presented in this work represents a quantitative and high-throughput method for the investigation of DLO with a low cost barrier for entry.

diffusion limited oxidation, DLO, nuclear, electri↗