Search NASA⌕ Search

SEARCH · Search NASA

Results for “Combustion diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combustion diagnostics by nonintrusive methods; Thermophysics Conference, 18th, Montreal, Canada, June 1-3, 1983, Selected Papers

The state of the art in coherent anti-Stokes Raman scattering (CARS) and laser-induced fluorescence (LIF) is outlined, and current diagnostic capabilities in particle and combustion diagnostics are demonstrated. The development and application of CARS to combustion systems is discussed, and the use of LIF for flow diagnostics is addressed. Nonintrusive particle diagnostics is treated, and a variety of nonintrusive techniques applied to combustion environments is considered.

Mccay, T. D.↗

Pulsed holography for combustion diagnostics

Image reconstruction and data extraction techniques were considered with respect to their application to combustion diagnostics. A system was designed and constructed that possesses sufficient stability and resolution to make quantitative data extraction possible. Example data were manually processed using the system to demonstrate its feasibility for the purpose intended. The system was interfaced with the PDP-11-04 computer for maximum design capability. It was concluded that the use of specialized digital hardware controlled by a relatively small computer provides the best combination of accuracy, speed, and versatility for this particular problem area.

Klein, N.↗

Microgravity Combustion Diagnostics Workshop

Through the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications (OSSA) at NASA Headquarters, a program entitled, Advanced Technology Development (ATD) was promulgated with the objective of providing advanced technologies that will enable the development of future microgravity science and applications experimental flight hardware. Among the ATD projects one, Microgravity Combustion Diagnostics (MCD), has the objective of developing advanced diagnostic techniques and technologies to provide nonperturbing measurements of combustion characteristics and parameters that will enhance the scientific integrity and quality of microgravity combustion experiments. As part of the approach to this project, a workshop was held on July 28 and 29, 1987, at the NASA Lewis Research Center. A small group of laser combustion diagnosticians met with a group of microgravity combustion experimenters to discuss the science requirements, the state-of-the-art of laser diagnostic technology, and plan the direction for near-, intermediate-, and long-term programs. This publication describes the proceedings of that workshop.

Santoro, Gilbert J.↗

The Filtered Abel Transform and Its Application in Combustion Diagnostics

Many non-intrusive combustion diagnosis methods generate line-of-sight projections of a flame field. To reconstruct the spatial field of the measured properties, these projections need to be deconvoluted. When the spatial field is axisymmetric, commonly used deconvolution method include the Abel transforms, the onion peeling method and the two-dimensional Fourier transform method and its derivatives such as the filtered back projection methods. This paper proposes a new approach for performing the Abel transform method is developed, which possesses the exactness of the Abel transform and the flexibility of incorporating various filters in the reconstruction process. The Abel transform is an exact method and the simplest among these commonly used methods. It is evinced in this paper that all the exact reconstruction methods for axisymmetric distributions must be equivalent to the Abel transform because of its uniqueness and exactness. Detailed proof is presented to show that the two dimensional Fourier methods when applied to axisymmetric cases is identical to the Abel transform. Discrepancies among various reconstruction method stem from the different approximations made to perform numerical calculations. An equation relating the spectrum of a set of projection date to that of the corresponding spatial distribution is obtained, which shows that the spectrum of the projection is equal to the Abel transform of the spectrum of the corresponding spatial distribution. From the equation, if either the projection or the distribution is bandwidth limited, the other is also bandwidth limited, and both have the same bandwidth. If the two are not bandwidth limited, the Abel transform has a bias against low wave number components in most practical cases. This explains why the Abel transform and all exact deconvolution methods are sensitive to high wave number noises. The filtered Abel transform is based on the fact that the Abel transform of filtered projection data is equal to an integral transform of the original projection data with the kernel function being the Abel transform of the filtering function. The kernel function is independent of the projection data and can be obtained separately when the filtering function is selected. Users can select the best filtering function for a particular set of experimental data. When the kernal function is obtained, it can be used repeatedly to a number of projection data sets (rovs) from the same experiment. When an entire flame image that contains a large number of projection lines needs to be processed, the new approach significantly reduces computational effort in comparison with the conventional approach in which each projection data set is deconvoluted separately. Computer codes have been developed to perform the filter Abel transform for an entire flame field. Measured soot volume fraction data of a jet diffusion flame are processed as an example.

Simons, Stephen N.↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Selected microgravity combustion diagnostic techniques

During FY 1989-1992, several diagnostic techniques for studying microgravity combustion have moved from the laboratory to use in reduced-gravity facilities. This paper discusses current instrumentation for rainbow schlieren deflectometry and thermophoretic sampling of soot from gas jet diffusion flames.

Griffin, Devon W.↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Capabilities and constraints of combustion diagnostics in microgravity

A significant scientific return from both existing and proposed microgravity combustion science experiments is substantially dependent on the availability of diagnostic systems for the collection of the required scientific data. To date, the available diagnostic instrumentation has consisted primarily of conventional photographic media and intrusive temperature and velocity probes, such as thermocouples and hot wire anemometers. This situation has arisen primarily due to the unique and severe operational constraints inherent in reduced gravity experimentation. Each of the various reduced gravity facilities is accompanied by its own peculiar envelope of capabilities and constraints. Drop towers, for example, pose strict limitations on available working volume and power, as well as autonomy of operation. In contrast, hardware developed for space flight applications can be somewhat less constrained in regards to the aforementioned quantities, but is additionally concerned with numerous issues involving safety and reliability.

Greenberg, Paul S.↗

Laser-induced fluorescence spectroscopy for combustion diagnostics

The types of spectroscopic and collisional measurements that are needed to develop laser-induced fluorescence as a diagnostic technique are discussed, with emphasis placed on combustion measurements. The spectroscopic measurements under collision-free conditions include production of radicals, excitation scan studies, lifetime measurements, and fluorescence scans. The collisional studies discussed here are quenching, energy transfer, and polarization phenomena. The results of recent laboratory experiments are presented.

Crosley, D. R.↗

Coherent anti-Stokes Raman spectroscopic modeling for combustion diagnostics

The status of modelling the coherent anti-Stokes Raman spectroscopy (CARS) spectra of molecules important in combustion, such as N2, H2O, and CO2, is reviewed. It is shown that accurate modelling generally requires highly precise knowledge of line positions and reasonable estimates of Raman linewidths, and the sources of these data are discussed. CARS technique and theory is reviewed, and the status of modelling the phenomenon of collisional narrowing at pressures well above atmospheric for N2, H2O, and CO2 is described. It is shown that good agreement with experiment can be achieved using either the Gordon rotational diffusion model or phenomenological models for inelastic energy transfer rates.

Hall, R. J.↗

Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

Quagliaroli, T. M.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for practical combustion diagnostics

Coherent anti-Stokes Raman spectroscopy (CARS) is a coherent wave-mixing process in which the signal emerges as a laser-like beam in a precise direction. The spectroscopic technique is appropriate to spatially and temporally resolved measurements of temperature and major species concentrations in combustion. It has been generated from all of the dominant constituents in air-fed, hydrogen, and hydrocarbon fueled combustion, and found applicable to practical combustion systems. High pressure effects on CARS spectra have also been examined.

Eckbreth, A. C.↗

The temperature dependence of inelastic light scattering from small particles for use in combustion diagnostic instrumentation

A computer calculation of the expected angular distribution of coherent anti-Stokes Raman scattering (CARS) from micrometer size polystyrene spheres based on a Mie-type model, and a pilot experiment to test the feasibility of measuring CARS angular distributions from micrometer size polystyrene spheres by simply suspending them in water are discussed. The computer calculations predict a very interesting structure in the angular distributions that depends strongly on the size and relative refractive index of the spheres.

Cloud, Stanley D.↗

Spectroscopic study of combustion diagnostics on hydroxyl radicals

Experimental observations of propane/air flames have been carried out. Measurements of hydroxyl (OH) radical concentration have been made using resonance line absorption techniques. A microwave-pumped low pressure discharge in argon and water vapor is employed to produce strong OH radical band radiation in the 308 nm region. This radiation is transmitted through the plume and absorption data is taken at various radial positions using an optical multichannel analyzer. This absorption data is used to compute OH number density using a model for the absorption band characteristics as a function of temperature based on an atlas of line strengths. A numerical computation of flow fields, temperature profile, OH number density and water vapor mass fraction profiles was carried out by using a technique of computational fluid dynamics (CFD). The results of CFD computation are compared with experimental observation with a good agreement.

Eskridge, Richard↗

Spectroscopic study of combustion diagnostics on hydroxyl radicals

Experimental observations of propane-air flames were performed. Measurements of hydroxyl (OH) radical concentration were made using resonance line absorption techniques. A microwave-pumped low pressure discharge in argon and water vapor is employed to produce strong OH radical band radiation in the 308 nm region. This radiation is transmitted through the plume and absorption data are taken at various radical positions using an optical multichannel analyzer. This absorption data is used to compute OH number density using a model for the absorption band characteristics as a function of temperature based on an atlas of line strengths. A numerical computation of flow fields, temperature profile and OH number density is carried out by using a technique of computational fluid dynamics (CFD). The results of CFD computation are good compared with experimental observation with a good agreement.

Hung, R. J.↗

Nonintrusive spectroscopic techniques for supersonic/hypersonic aerodynamics and combustion diagnostics

This paper presents an overview of the primary nonintrusive diagnostic techniques being developed by the NASA Langley Research Center to address the validation needs of Computational Fluid Dynamic (CFD) codes. The techniques include absorption in the UV and IR, Laser Induced Fluorescence, electron beam fluorescence, and a number of scattering techniques including Rayleigh, spontaneous Raman, and several coherent Raman spectroscopies. Most of the techniques are highly specialized, require complex data interpretation, and can satisfy only a few of the CFD needs. For these reasons, the evolving trend in flowfield diagnostics appears to favor a mode in which the diagnostic researcher, the experimental aerodynamicist, and the CFD community jointly define experiments based on the aeronautical requirements and on available diagnostic techniques.

Exton, R. J.↗

Flame Chemiluminescence Rate Constants for Quantitative Microgravity Combustion Diagnostics

Absolute excited state concentrations of OH(A), CH(A), and C2(d) were determined in three low pressure premixed methane-air flames. Two dimensional images of chemiluminescence from these states were recorded by a filtered CCD camera, processed by Abel inversion, and calibrated against Rayleigh scattering, Using a previously validated 1-D flame model with known chemistry and excited state quenching rate constants, rate constants are extracted for the reactions CH + O2 (goes to) OH(A) + CO and C2H + O (goes to) CH(A) + CO at flame temperatures. Variations of flame emission intensities with stoichiometry agree well with model predictions.

Luque, Jorge↗