An alternative method of changing the pulse duration in a stretcher-compressor pair by changing the gas pressure in the compressor

The relatively narrow bandwidth of neodymium glass requires a much larger stretch ratio of chirped-pulse amplification (CPA) systems. This factor, together with a large incident angle on the gratings, makes glass CPA systems extremely sensitive to the refractive index of the medium in the stretcher-compressor. High sensitivity of the stretcher-compressor pair for hybrid optical parametric chirped-pulse amplification and an Nd:glass laser to the refractive index was demonstrated in air, vacuum, and carbon dioxide, and a pulse duration close to the transform limit was reached. An alternative way to change the pulse duration was proposed. The pulse duration from the best compression of 500 fs to 30 ps was smoothly varied by changing the air pressure from 10 -6 Torr to 1 atm in the compressor and up to 52 ps in carbon dioxide, while the stretcher and compressor remained untouched. Finally, excellent agreement of the measured pulse duration with theoretical calculations was demonstrated.

47 OTHER INSTRUMENTATION

Enabling Robust Compressor Operation Under Various sCO 2 Conditions at Compressor Inlet

The supercritical carbon dioxide (sCO 2 ) power cycle is one of the most investigated power conversion systems in last decade. The reason for this is its wide range of potential applications from fossil fuels (Natural gas), nuclear (Fusion, Fission), through concentrated solar power, energy storage system and waste heat recovery systems to power-to-x systems. The main advantage of the sCO 2 power cycle is very similar operation conditions, especially for the compressor, for all potential applications. Because of this the potential cost of the system can be reduced. However, the sCO 2 power cycle has still several issue that needs to address before commercial application. The current key issue is design of the primary compressor. The primary compressor is one of the key components in the sCO 2 power cycle; it operates with inlet conditions just above the critical point of CO 2 to maintain high fluid density and reduce power requirements.

14 SOLAR ENERGY

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Gorazd Medic

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control

Aerodynamic Design of Axial Flow Compressors

An overview of 'Aerodynamic systems design of axial flow compressors' is presented. Numerous chapters cover topics such as compressor design, potential and viscous flow in two dimensional cascades, compressor stall and blade vibration, and compressor flow theory. Theoretical aspects of flow are also covered. This work is based substantially on a three-volume Confidential Research Memorandum f h t issued by the National Advisory Committee for Aeronautics in 1956 and declassified in .1958 for release to the general public. The material, which was of a fundamental character, has been updated for the present edition in the light of subsequent developments in the field and has been carefully reexamined for current validity by members of the staff of the NASA Lewis Research Center, Cleveland, Ohio. It is now published for the first time in a single volume to meet continuing demand for the information and to make it readily available in convenient form to the engineering community both within and outside the National Aeronautics and Space Administration.

Axial flow compressor

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control

A Review of the Research and Development of Brayton Cycle Technology in Nuclear Power Applications with a Focus on Compressor Technology

This study reviews the integration of Brayton Cycle (BC) systems in nuclear power generation, emphasizing their potential to enhance thermal efficiency and operational flexibility over traditional Rankine Cycle (RC) systems. Key working fluids, such as helium (He), supercritical carbon dioxide (sCO 2 ), nitrogen (N 2 ), and air, are evaluated for their performance, efficiency, and compatibility with nuclear systems. He is recognized for its high thermal conductivity and inertness at elevated temperatures, while sCO 2 demonstrates advantages in compactness and efficiency in midrange temperatures. This article also highlights the importance of compressor designs in optimizing BC performance and reviews, available compressor technologies. Axial and centrifugal compressor designs enable efficient gas compression while managing the thermal and mechanical stresses associated with high-pressure operations in nuclear systems. Combined with variable geometry components and advanced materials, these technologies address the challenges posed by varying load conditions. Despite the promising features of BC systems, several challenges persist, including high leakage rates and material degradation under extreme conditions, which necessitate robust sealing technologies and thorough testing. The insights gained from operational experiences at facilities, such as the Oberhausen II plant and the High-Temperature He Test Facility (HHV), underscore the complexities involved in designing high-temperature gas turbines for nuclear applications. This review concludes that as the nuclear industry evolves, BC systems hold significant promise for contributing to a sustainable energy future, particularly in the context of small modular reactors (SMRs) and microreactors. Further exploration of combined cycle configurations that combine BCs with RCs may enhance overall efficiency and flexibility in power generation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Commissioning Results of the ESR2 Compressors at JLab

Abstract The future operation of the 4 kW 15 Kelvin MOLLER experiment at Jefferson lab necessitates an increase of cryogenic capacity at the End Station Refrigerator. The current plant is the former 1.5 kW (4.5 K) ESCAR plant that has been operating at Jefferson Lab since 1995. The existing 1.5 kW plant is not able to support the load for MOLLER and will be replaced with a refurbished plant comprised of the cold box and compressors of the 4 kW ASST-A plant from the Superconducting Super Collider in Texas. This paper reports the commissioning results of the warm compressor system. We compare the compressors’ current and past performance, specifically examining their Isothermal and Volumetric efficiency. The results indicate that the refurbished equipment’s efficiency is comparable to its original performance, proving that the reuse and refurbishment of old systems is a worthwhile endeavor.

Perry, C. [Thomas Jefferson National Accelerator F

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

vaned diffuser

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

centrifugal compressor

Hybrid Thermally Efficient Core (HyTEC) Phase 1 3-Stage Compressor Rig Final Report - Unlimited Rights

The HyTEC Phase 1 3-Stage Compressor Rig project was conducted to mature and validate front-stage aerodynamic technologies in support of HyTEC Phase 2 and GEA’s Compact Core compressor. Building on the prior ERA Phase 2 Baseline Rig, GEA and NASA collaborated on the design and testing of the HyTEC rig, incorporating advanced technologies such as increased radius ratio, higher aerodynamic loading, and advanced casing treatment. The HyTEC test campaign leveraged similar design and instrumentation philosophy, test execution approach, and the same facility (NASA W-7) to enable clear comparison with the legacy ERA rig results. The HyTEC rig was designed to deliver benefits in efficiency, tip loading, operability, and aeromechanics, with success measured against defined TPMs that were anchored to the ERA baseline rig data.

Axial Compressors

Dynamic modeling of near isothermal compressor for Transcritical carbon dioxide cycle to support efficiency improvement

Compressors are the primary components of energy consumption in vapor compression systems, drawing considerable research effort to reduce carbon emissions and improve energy efficiency. This work presents an isothermal compressor that integrates the compression chamber with the gas cooler to achieve near-isothermal compression, resulting in up to 30% energy reduction compared to traditional isentropic compression, according to the experiment results. A detailed dynamic model for the isothermal compression cycle of carbon dioxide (CO 2 ) is first presented, coupled with a liquid-piston model for chamber design. The model is experimentally validated on a 3.5 kW prototype, yielding a 6.2% relative error in chamber pressure and a 0.5 K deviation in chamber temperature. The liquid piston exhibits reduced frictional heating and geometric adaptability relative to the mechanical piston. Leveraging these attributes, the study further evaluates approaches that enhance the heat transfer to achieve isothermal compression by increasing the effective heat transfer area during compression. As a result, simulations demonstrated up to a 5% improvement in the coefficient of performance over the baseline case through chamber design, providing guidelines for design of isothermal compression cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)

Plasma-based prism compressor design for high-intensity laser pulses

A concept for a femtosecond pulse compressor based on underdense plasma prisms is presented. An analytical model is developed to calculate the spectral phase incurred and the expected pulse compression. A 2D particle-in-cell simulation verifies the analytical model. Simulated intensities ( ∼10 16 W/cm 2 ) were orders of magnitude higher than the damage threshold for conventional gratings used in chirped pulse amplification. Theoretical geometries for compact (tens of cm scale) compressors for 1, 10 and 100 PW power levels are proposed.

47 OTHER INSTRUMENTATION

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.