Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison between the magnetic and transport critical current densities in high critical current density melt-textured yttrium barium copper-oxide

Using a recently developed pulsed critical current density (Jc) measuring system, the Jc of the high-Jc melt-textured YBa2Cu3O(7-delta) (Y123) bulk samples has been determined. I-V curves with a voltage resolution of 0.5 microV were obtained, and transport Jc's along the a-b plane as high as 7.2 x 10 to the 4th A/sq cm were extracted. These results are comparable to the values obtained magnetically. On the other hand, transport Jc along the c axis were found to be two orders of magnitude smaller, even though the magnetic Jc along the c axis is only about five times smaller than Jc along the a-b plane. It is suggested that for the high-temperature superconducting materials which are highly anisotropic, caution should be taken when using the nontransport magnetic methods to determine Jc.

Gao, L.↗

Correlations between critical current density, j(sub c), critical temperature, T(sub c),and structural quality of Y1B2Cu3O(7-x) thin superconducting films

Correlations between critical current density (j(sub c)) critical temperature (T(sub c)) and the density of edge dislocations and nonuniform strain have been observed in YBCO thin films deposited by pulsed laser ablation on (001) LaAlO3 single crystals. Distinct maxima in j(sub c) as a function of the linewidths of the (00 l) Bragg reflections and as a function of the mosaic spread have been found in the epitaxial films. These maxima in j(sub c) indicate that the magnetic flux lines, in films of structural quality approachingthat of single crystals, are insufficiently pinned which results in a decreased critical current density. T(sub c) increased monotonically with improving crystalline quality and approached a value characteristic of a pure single crystal. A strong correlation between j(sub c) and the density of edge dislocations ND was found. At the maximum of the critical current density the density of edge dislocations was estimated to be N(sub D) approximately 1-2 x 10(exp 9)/sq cm.

Chrzanowski, J.↗

Critical currents in sputtered PbMo6S8

Critical currents in sputtered Chevrel-phase lead molybdenum sulfide have been measured at several temperatures as a function of applied magnetic field up to 19 T. A critical current density of approximately 50 million A/sq m was obtained at 15 T and 1.8 K, and the effective upper critical field was estimated to be 30 T. The pinning force at low fields was found to be dependent on the amount of free lead.

Alterovitz, S. A.↗

Noncontact Measurement Of Critical Current In Superconductor

Critical current measured indirectly via flux-compression technique. Magnetic flux compressed into gap between superconductive hollow cylinder and superconductive rod when rod inserted in hole in cylinder. Hall-effect probe measures flux density before and after compression. Method does not involve any electrical contact with superconductor. Therefore, does not cause resistive heating and consequent premature loss of superconductivity.

Israelsson, Ulf E.↗

Comparison of projected critical currents in PbMo6S8 and Nb3Ge

Critical current densities, Jc, of sputtered Chevrel phase PbMo6S8 films have been measured as a function of field to 19 T at several temperatures. The pinning forces were found to obey a scaling law. Assuming an effective upper critical field Bc2 = 45 T, an effective critical temperature Tc = 13 K, together with empirical estimates of numerical factors in the scaling law, the upper limits for critical current density Jc in PbMo6S8 are estimated. Comparisons are made with estimates of Jc for Nb3Ge at 4.2 K. A crossover of Jc vs. B is found for B of the order of 25 to 30 T. Below this point, Nb3Ge is projected to have a higher critical current density. Thus practical use of Chevrel materials in high field magnets only appears to be competitive with Nb3Ge for fields above 25 to 30 T.

Alterovitz, S. A.↗

Critical currents in sputtered copper molybdenum sulphide

Critical currents in a sputtered Chevrel-phase copper molybdenum sulfide have been measured at 4.2 K as a function of applied magnetic field. Self-field critical-current values up to 10 to the 9th A/sq m were found, decreasing to 10 to the 8th A/sq m at 3 T. Graphs of pinning forces versus field were found to be independent of field direction, and the pinning mechanism is sample independent. Critical-current densities for sputtered lead molybdenum sulphide are estimated to be about 10 to the 8th A/sq m at 26 T based on a scaling law for pinning.

Alterovitz, S. A.↗

A study of enhancing critical current densities (J(sub c)) and critical temperature (T(sub c)) of high-temperature superconductors

The development of pure phase 123 and Bi-based 2223 superconductors has been optimized. The pre-heat processing appears to be a very important parameter in achieving optimal physical properties. The synthesis of pure phases in the Bi-based system involves effects due to oxygen partial pressure, time, and temperature. Orientation/melt-sintering effects include the extreme c-axis orientation of Yttrium 123 and Bismuth 2223, 2212, and 2201 phases. This orientation is conductive to increasing critical currents. A procedure was established to substitute Sr for Ba in Y-123 single crystals.

Vlasse, Marcus↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Critical currents and high-temperature superconductors

Experimental information on critical currents and epitaxial thin films of high temperature superconductors is summarized. Experiments performed to measure critical currents across single grain boundaries are described. A variety of mechanisms responsible for limiting currents in films as well as across grain boundaries are presented and their predictions compared with experimental data.

Chaudhari, P.↗

Critical currents and high temperature superconductors

The experimental information on critical currents and epitaxial thin films of high temperature superconductors is summarized. Experiments carried out to measure critical currents across single grain boundaries are described. A variety of mechanisms responsible for limiting currents in films as well as across grain boundaries are presented and their predictions compared with experimental data.

Chaudhari, P.↗

Critical currents in A-15 structure Nb3Al converted from cold-worked bcc structure

The paper considers critical currents in A-15 structure Nb3Al converted from a cold-worked bcc structure. Nb3Al prepared in the ductile phase by quenching and mechanical working followed by conversion to the A-15 structure could carry currents above 10 to the 9th power A/sq m in fields near 20 T. These critical currents are comparable to those of Nb3Ge and V3Ga which are closest competing materials for use in high fields; further enhancement of the critical current is possible if thermal treatments are optimized.

Woollam, J. A.↗

Effects of grain size and grain boundary on critical current density of high T(sub c) superconducting oxides

By means of adding impurity elements in high T sub c oxides, the effects were studied of grain size and grain boundary on the critical current density of the following systems: YBa2Cu3O(7-y) and Bi-Pr-Sr-Ca-Cu-O. In order to only change the microstructure instead of the superconductivity of the grains in the samples, the impurity elements were added into the systems in terms of the methods like this: (1) substituting Y with the lanthanide except Pr, Ce, and Tb in YBa2Cu3O(7-y) system to finning down grains in the samples, therefore, the effect can be investigated of the grain size on the critical current density of 1:2:3 compounds; (2) mixing the high T sub c oxides with the metal elements, such as Ag, according to the composition of (high T sub c oxide)1-xAgx to metallize the grain boundaries in the samples, studying the effect of the electric conductivity of the grain boundaries on the critical current density; (3) adding SiO2, PbO2, and SnO2 into the high T sub c oxide to form impurity phases in the grain boundaries, trying to find out the effects of the impurity phases or metalloid grain boundaries on the critical current density of the high T sub c superconductors. The experimental results indicate that in the case of of the presence of the metalloid grain boundaries finning down grains fails to enhance the j sub c, but restrains it strongly, the granular high T sub c superconductors with the small size grains coupled weakly is always the low j sub c system.

Zhao, Y.↗

Correlations Between In-Line X-ray Diffraction Data and In-Field Critical Current of Long, 4-μm Thick Film REBCO Tapes Made by Advanced MOCVD

REBa 2 Cu 3 O 7-δ (REBCO, RE = rare earth) tapes with high critical current can be very impactful in high magnetic field applications at low temperatures and power applications at high temperatures. A pilot-scale Advanced Metal Organic Chemical Vapor Deposition (MOCVD) method was used to fabricate 50-m-long, 4+μm-thick REBCO tape in a single pass. Critical currents 3.3x that of commercial HTS tapes were achieved at 20 K, 12 T in these 50-m-long tapes. An in-line 2D X-ray Diffraction (XRD) system has been used to assess the quality of the long tapes in real-time, during manufacturing. The key peaks of REBCO, REO, and BZO phases were identified and utilized for tape quality analysis. Furthermore, a 20-m tape made by Advanced MOCVD was tested over its entire length by reel-to-reel (R2R) scanning Hall-probe microscopy (SHPM) at 65 K, 0.25 T, 2 T, and 4 T. 4-mm-wide strands of Advanced MOCVD tapes showed mean critical currents at 65 K of 530 A, 200 A, and 104 A at 0.25 T, 2 T, and 4 T respectively. The combined use of in-line and offline characterization techniques provides a reliable approach for assessing long REBCO tapes during manufacturing, serving as an effective feedback source for quality control in scaled-up REBCO tape deposition processes. This advancement contributes to the production of longer and more uniform high-performance REBCO tapes for large-scale, high-field superconducting applications

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transport critical current and magnetization measurements of melt-processed YBa2Cu3O(7-x)

This paper reports on the magnetic field dependence of the transport critical current and dc magnetic susceptibility measurements on YBa2Cu3O(7-x) superconductors formed by melt-solid reactions at 950 C between Ba-Cu-O (or Tb-Ba-cu-O) and solid nonstoichiometric Y-Ba-Cu oxide. Four-probe dc critical current measurements at 77, 64, and 4.2 K show strong depression of the critical current density with increasing magnetic field, in agreement with a model of weakly linked superconducting regions. Diamagnetic shielding and Meissner flux expulsion measurements in the temperature range 10-300 K show about one-third volume fraction of perfect superconductivity. Both shielding and flux expulsion were observed to be approximately temperature independent below 60 K, indicating strong coupling between the grains throughout the entire volume below this temperature.

Hermann, A. H.↗

Magnetic Field Dependence of the Critical Current in S-N Bilayer Thin Films

Here we investigate the effects a non-uniform applied magnetic field has on superconducting transition-edge sensors (TESs) critical current. This has implications on TES optimization. It has been shown that TESs resistive transition can be altered by magnetic fields. We have observed critical current rectification effects and explained these effects in terms of a magnetic self-field arising from asymmetric current injection into the sensor. Our TES physical model shows that this magnetic self-field can result in significantly degraded or improved TES performance. In order for this magnetically tuned TES strategy to reach its full potential we are investigating the effect a non-uniform applied magnetic field has on the critical current.

Field Dependence↗

Diamagnetic mechanism of critical current non-reciprocity in multilayered superconductors

The suggestion that non-reciprocal critical current (NRC) may be an intrinsic property of non-centrosymmetric superconductors has generated renewed theoretical and experimental interest motivated by an analogy with the non-reciprocal resistivity due to the magnetochiral effect in uniform materials with broken spatial and time-reversal symmetry. Theoretically it has been understood that terms linear in the Cooper pair momentum do not contribute to NRC, although the role of higher-order terms remains unclear. In this work we show that critical current non-reciprocity is a generic property of multilayered superconductor structures in the presence of magnetic field-generated diamagnetic currents. In the regime of an intermediate coupling between the layers, the Josephson vortices are predicted to form at high fields and currents. Experimentally, we report the observation of NRC in nanowires fabricated from InAs/Al heterostructures. The effect is independent of the crystallographic orientation of the wire, ruling out an intrinsic origin of NRC. Non-monotonic NRC evolution with magnetic field is consistent with the generation of diamagnetic currents and formation of the Josephson vortices. This extrinsic NRC mechanism can be used to design novel devices for superconducting circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

40-meter-long REBCO tapes with critical current over 4,000 A/12 mm at 4.2 K and 13 T by advanced MOCVD

REBa 2 Cu 3 O 7–δ (REBCO, RE = rare earth) tapes doped with 5% and 15% Zr have been scaled up to lengths more than 40 m in a pilot-scale advanced metal organic chemical vapor deposition (A-MOCVD) tool. The precursor compositions used for the long tapes were guided by a study of the influence of (Ba + dopant)/Cu content on the critical current density (J c ) of 5 and 15 mol.% Hf- and Zr-added tapes at 4.2 K and 13 T. The 40-m-long tapes exhibited a critical current (I c ) over 4,000 A/12 mm at 4.2 K and 13 T as well as over 1,400 A/12 mm at 20 K and 20 T. The critical current densities of a 40-m-long tape doped with 5% Zr at 4.2 K measured at the National High Magnetic Field Laboratory (NHMFL) were > 10 MAcm –2 and >5 MAcm –2 at 14 T and 30 T, respectively, which are over three times those of commercial REBCO tapes. The infield J c of 5% Zr-added 40-m-long tapes was similar to those of previously-reported high-performance short samples made with 15% Zr or Hf. These results demonstrate the excellent potential of A-MOCVD for manufacturing high I c REBCO tapes for use in ultrahigh-field magnet applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗